[The Grauballe man. Medical examinations of a conserved moss man's corpse].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M Dalstra.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Recently, it has been shown that statins increased cancellous bone formation and volume in 3-month-old rats and induced a minor decrease in osteoclast number. In the present study, one-year-old female rats were given simvastatin (10 mg/kg) or placebo daily for 3 months by a gastric tube. Specimens, 2.0 mm high, were cut transversely from the 5th lumbar vertebral body. The cancellous bone core diameters within the cortical shell of each specimen were delineated by a micro-CT scanner and then the cancellous bone was compressed in a materials testing machine between an upper and a lower platen with a diameter corresponding to the diameter of the cancellous bone core of each specimen. The cancellous bone volume was determined histomorphometrically on transverse sections. The cancellous bone volume in the simvastatin group (52.7 +/- 1.6%, mean value +/- SEM) was increased by 23% compared with the placebo group (42.8 +/- 1.7%). The compressive stress of the cancellous bone from the simvastatin group (31.8 +/- 2.7 MPa) was increased by 24% compared with the placebo group (24.1 +/- 1.9 MPa). No changes were found in cortical bone mass and strength after the statin treatment. In conclusion, statin given perorally to adult rats increased cancellous bone mass and increased cancellous bone compressive strength. The cancellous bone was found to possess normal biomechanical competence after the statin treatment.
The objective of the present study was (1) to test the hypothesis that the elastic and failure properties of the cancellous bone of the mandibular condyle depend on the loading direction, and (2) to relate these properties to bone density parameters. Uniaxial compression tests were performed on cylindrical specimens (n=47) obtained from the condyles of 24 embalmed cadavers. Two loading directions were examined, i.e., a direction coinciding with the predominant orientation of the plate-like trabeculae (axial loading) and a direction perpendicular to the plate-like trabeculae (transverse loading). Archimedes' principle was applied to determine bone density parameters. The cancellous bone was in axial loading 3.4 times stiffer and 2.8 times stronger upon failure than in transverse loading. High coefficients of correlation were found among the various mechanical properties and between them and the apparent density and volume fraction. The anisotropic mechanical properties can possibly be considered as a mechanical adaptation to the loading of the condyle in vivo.
This study evaluated the biomechanical strength and bone formation in calvarial critical size bone defects covered with expanded polytetrafluoroethylene (e-PTFE) membranes in rats treated systemically with recombinant human growth hormone (rhGH). A full-thickness bone defect, 5 mm in diameter, was trephined in the central part of each parietal bone in 40 one-year-old female Wistar rats, which were randomly assigned to two groups of 20 animals each. The bone defects were covered with an exocranial and an endocranial e-PTFE membrane. From the day of operation, the rhGH-treated animals were given 2.7 mg rhGH/kg/day and the placebo-injected rats were given isotonic sodium chloride. The animals were killed 28 days after operation. The biomechanical test was performed by a punch out test procedure placing a 3.5-mm diameter steel punch in the centre of the right healed defect. After mechanical testing, the newly formed tissue inside the defect was removed and the dry and ash weights were measured. The left healed defects were used for three-dimensional (3D) reconstruction by means of micro-computer tomography (micro-CT). Ultimate load, ultimate stiffness, and energy absorption at ultimate load were significantly increased in the rhGH-treated group (P < 0.003). Also, tissue dry and ash weights were significantly augmented in the rhGH-treated group (P < 0.001). The 3D reconstruction of newly formed bone showed that there was almost twice as much bone volume present in the rhGH-treated defects compared with the placebo group. The experiment demonstrated that rhGH administration enhances bone deposition and mechanical strength of healing rat calvarial defects, covered with e-PTFE membranes.
Three-dimensional finite element analysis is one of the best ways to assess stress and strain distributions in complex bone structures. However, accuracy in the results may be achieved only when accurate input information is given. A semi-automated method to generate a finite element (FE) model using data retrieved from computed tomography (CT) was developed. Due to its complex and irregular shape, the glenoid part of a left embalmed scapula bone was chosen as working material. CT data were retrieved using a standard clinical CT scanner (Siemens Somatom Plus 2, Siemens AG, Germany). This was done to produce a method that could later be utilized to generate a patient-specific FE model. Different methods of converting Hounsfield unit (HU) values to apparent densities and subsequently to Young's moduli were tested. All the models obtained were loaded using three-dimensional loading conditions taken from literature, corresponding to an arm abduction of 90 degrees. Additional models with different amounts of elements were generated to verify convergence. Direct comparison between the models showed that the best method to convert HU values directly to apparent densities was to use different equations for cancellous and cortical bone. In this study, a reliable method of determining both geometrical data and bone properties from patient CT scans for the semi-automated generation of an FE model is presented.
Several types of pedicle screw systems have been utilized to augment lumbar spine fusion. The majority of these systems are made of stainless steel (Ss), but titanium-alloy (Ti-alloy) devices have recently been available on the market. Ti-alloy implants have several potential advantages over Ss ones. High bioactivity and more flexibility may improve bone ingrowth and mechanical fixation, and the material also offers superior magnetic resonance imaging (MRI) and computed tomography (CT) resolution and significantly less signal interference. However, no data are available from loaded spinal constructs regarding bony ingrowth and mechanical fixation. The aim of this study was to analyse the effect of Ti-alloy versus Ss pedicle screws on mechanical fixation and bone ingrowth in a loaded mini-pig model. Eighteen adult mini-pigs underwent total laminectomy and posterolateral spinal fusion at L3-L4, and were randomly selected to receive either Ss (n = 9) or Ti (n = 9) pedicle screw devices. In both groups, the device used was compact Cotrel-Dubousset instrumentation (Sofamore Danek) of an identical size and shape. The postoperative observation time was 3 months. Screws from L3 were used for histomorphometric studies. Mechanical testing (torsional tests and pull-out tests) was performed on the screws from L4. The Ti screws had a higher maximum torque (P < 0.05) and angular stiffness (P < 0.07), measured by torsional testing. In the pull-out tests, no differences were found between the two groups with respect to the maximum load, stiffness and energy to failure. No correlation between removal torque and the pull-out strength was found (r = 0.1). Bone ongrowth on Ti was increased by 33% compared with Ss (P < 0.04), whereas no differences in bone volume around the screws were shown. Mechanical binding at the bone-screw interface was significantly greater for Ti pedicle screws than for Ss, which was explained by the fact that Ti screws had a superior bone ongrowth. There was no correlation between the screw removal torque and the pull-out strength, which indicates that the peripheral bone structure around the screw was unaffected by the choice of metal.
The mechanical properties of the newly introduced titanium-niobium finishing wires were investigated. Both in bending and torsional loading mode, the stiffness, yield point, post-yield behavior, and springback of titanium-niobium wires were experimentally determined and compared to those of equally sized stainless steel wires. The experimentally obtained values were also validated with theoretical values from engineering formulas of cantilever deformations. The ratios for these parameters for the two materials proved to be different in bending and torsion. The stiffness of titanium-niobium in bending is roughly half of that of stainless steel, whereas in torsion it is roughly one-third. These characteristics enable the clinician to use titanium-niobium for creative bends without the excessive force levels of steel wires. The springback of titanium-niobium in bending is 14% lower than that of steel, whereas in torsion it is about the same or even slightly higher than that of steel, thus making it possible to utilize the wire for even major third-order corrections. Finally, the weldability of titanium-niobium wires was found to be good, so it is possible to weld wires of different dimensions together for the generation of differentiated force systems.
The influence of bone metabolism on both the rate and the type of orthodontic tooth movement was investigated. A rat model in which high (n = 16) and low (n = 17) bone turnover was pharmacologically induced was used. A non-pharmacologically treated group (n = 19) served as the control. A mesially directed constant single force of 25 cN was applied to the upper left first molar for a period of 3 weeks. The study was performed as a split-mouth design, the contralateral side of each animal serving as its control. The displacement of the molar crown was measured with an electronic calliper, while changes in inclination of the teeth were measured from micro-CT scans of the excised maxillae. The bone turnover significantly affected the rate of tooth movement. In the case of high turnover, the rate of tooth movement was increased while it was reduced in the case of low turnover. A controlled mesial tipping in all three groups was observed, but the actual location of the centre of rotation seemed to be influenced by the metabolic state of the bone. Based on the results it can be concluded that deviations in bone turnover influence the response to orthodontic forces, and should be taken into consideration when planning orthodontic treatment in patients with metabolic bone disease or those on chronic medication influencing bone metabolism.
Conceptually, the elastic characteristics of cancellous bone could be predicted directly from the trabecular morphology--or architecture--and by the elastic properties of the tissue itself. Although hardly any experimental evidence exists, it is often implicitly assumed that tissue anisotropy has a negligible effect on the apparent elastic properties of cancellous bone. The question addressed in this paper is whether this is actually true. If it is, then micromechanical finite element analysis (micro-FEA) models, representing trabecular architecture, using an 'effective isotropic tissue modulus' should be able to predict apparent elastic properties of cancellous bone. To test this, accurate multi-axial compressive mechanical tests of 29 whale bone specimens were simulated with specimen-specific micro-FEA computer models built from true three-dimensional reconstructions. By scaling the micro-FEA predictions by a constant tissue modulus, 92% of the variation of Young's moduli determined experimentally could be explained. The correlation even increased to 95% when the micro-FEA moduli were scaled to the isotropic tissue moduli of individual specimens. Excellent agreement was also found in the elastic symmetry axes and anisotropy ratios. The prediction of Poisson's ratios was somewhat less precise at 85% correlation. The results support the hypothesis; for practical purposes, the concept of an 'effective isotropic tissue modulus' concept is a viable one. They also suggest that the value of such a modulus for individual cases might be inferred from the average tissue density, hence the degree of mineralization. Future studies must clarify how specific the tissue modulus should be for different types of bone if adequate predictions of elastic behavior are to be made in this way.
OBJECTIVES: To describe the force systems developed by cantilevers with different configurations during incisor intrusion. DESIGN: A two-dimensional Finite Element model. SETTING AND SAMPLE STUDIED: Laboratories of the Department of Orthodontics, Royal Dental College, Aarhus University, Denmark. The materials studied comprised cantilevers made of 0.017" x 0.025" TMA wire. EXPERIMENTAL VARIABLE: Vertical activation of the six different modelled cantilever configurations. OUTCOME MEASURE: Force level and direction during activation and deactivation analysed at the point of force application. RESULTS: The force direction was dependent on the configuration of the cantilever. Only the cantilevers with a curvature produced combined retraction and intrusion forces. All other configurations resulted in combined protrusion and intrusion, which reversed into retraction and intrusion, according to the variations in deactivation. CONCLUSION: The choice of correct cantilever configuration is important when selecting the mechanics of intrusion for a particular patient.
OBJECTIVE: To investigate the differences in bone interface between titanium and stainless steel pedicle screws in the lumbar spine. METHODS: Eighteen adult mini-pigs that underwent total laminectomy, posterolateral spinal fusion (L4-L5) were randomly selected to receive stainless steel (9) or titanium pedicle screw devices (9). In both groups, the devices were CCD (Sofamore Danek) type with the same size and shape. The postoperative observation time was 3 months. Screws from L4 were harvested along their long axis of pedicle for histomorphometric study. Bone-screw interface and bone volume from thread were examined using linear intercept techniques. Mechanical testing (torsional test and pull-out test) was performed on the screws from L5. RESULTS: The titanium screw group had a significantly higher maximum torque (P < 0.05) and angle related stiffness (P < 0.05) measured by torsional test. In the pull-out tests, no differences were found between the two groups in relation to the maximum load, stiffness and energy to failure. Direct bone contact with the screw in percentage was 29.4% for stainless steel and 43.8% for titanium (P < 0.05). No differences in the bone purchase between the vertebral body part and pedicle part were found. CONCLUSION: Pedicle screws made of titanium have a better bone-screw interface binding than screws made of stainless steel. Torsional tests are more informative for bone-screw interface study. Pull-out tests seem less valuable when comparing bone purchase of screws made from different materials.
OBJECTIVE: This study investigates the age-related variations in the mechanical properties of the normal human tibial cartilage-bone complex and the relationships between cartilage and bone. DESIGN: A novel technique was applied to assess the mechanical properties of the cartilage and bone by means of testing the cartilage-bone complex. BACKGROUND: Up to now, mechanical testing of cartilage and bone has been reported separately, and little is known about the mechanical behaviour of both tissues when examined as a unit. METHODS: Cylindrical human proximal tibial cartilage-bone complex specimens from 31 normal donors aged 16-83 years were tested in compression. The deformation was measured simultaneously in bone and cartilage to obtain the mechanical properties of both tissues. RESULTS: The stiffnesses and elastic energies of both cartilage and bone showed an initial increase, with maxima at 40 years, followed by a steady decline. The viscoelastic energy was maximal at younger ages (16-29 years), followed by a steady decline. The energy absorption capacity did not vary with age. Stiffnesses and elastic energies were correlated significantly between cartilage and bone. CONCLUSIONS: The present study demonstrates that similar age-related trends were seen in cartilage and bone, as if they behaved as a single mechanical unit. RELEVANCE: The basic information presented here on the mechanical properties of cartilage and bone and the correlations between them reveals the unit function of both tissues that are of importance for the understanding of the etiology and pathogenesis of degenerative joint diseases, such as arthrosis.
Cylindrical human tibial cartilage-bone unit specimens were removed from 9 early-stage medial osteoarthrotic (OA) tibiae (mean age 74 years) and 10 normal age-matched tibiae (mean age 73 years). These specimens were divided into 4 groups: OA, lateral comparison, medial age-matched, and lateral age-matched and were tested to 0.5% bone strain with a novel technique to obtain the stiffnesses of both cartilage and bone simultaneously. We found a pronounced reduction in the stiffnesses of OA cartilage and subchondral bone when compared with the medial age-matched group. OA cartilage was significantly thinner than that of the lateral comparison and the medial age-matched control groups. However, this reduction in thickness was not correlated with the reduction in stiffness for OA cartilage. The stiffnesses did not correlate between OA cartilage and bone, whereas the stiffness relationships between cartilage and bone remained significant in the three control groups. Our findings suggest that both cartilage and bone in early-stage OA are mechanically inferior to normal, and that OA cartilage and bone have lost their unit function to mechanical loading.
Cancellous bone architecture and mechanics are intimately related. The trabecular architecture of cancellous bone is considered determined by its mechanical environment (Wolff's law), and the mechanical properties of cancellous bone are inversely determined by the trabecular architecture and material properties. Much effort has been spent in expressing these relations, but the techniques and variables necessary for this have not been fully identified. It is obvious, however, that some measure of architectural anisotropy (fabric) is needed. Within the last few years, volume-based measures of fabric have been introduced as alternatives to the mean intercept length method, which has some theoretical problems. This paper seeks to answer which of four different fabric measures best predicts finite element calculated mechanical anisotropy directions. Twenty-nine cancellous bone specimens were three-dimensionally reconstructed using the automated serial sectioning technique. A series of large-scale finite-element analyses were performed on each of the three-dimensional reconstructions to calculate the compliance matrix for each specimen, from which the mechanical principal directions were derived. The architectural anisotropy was determined in three-dimensional space for each specimen using mean intercept length (MIL), volume orientation (VO), star volume distribution (SVD) and star length distribution (SLD). Each of the architectural anisotropy results were expressed by a fabric tensor. Architectural main directions were determined from the fabric tensors and compared with the FE-calculated mechanical anisotropy directions. All architectural measures predicted the mechanical main directions rather well, which supports the assumption that mechanical anisotropy directions are aligned with fabric directions. MIL showed a significant, though very small (1.4 degrees), deviation from the primary mechanical direction. VO had difficulty in determining secondary and tertiary mechanical directions; its mean deviation was 8.9 degrees. SVD and SLD provided marginally better predictors of mechanical anisotropy directions than MIL and VO.
We tested in compression specimens of human proximal tibial trabecular bone from 31 normal donors aged from 16 to 83 years and determined the mechanical properties, density and mineral and collagen content. Young's modulus and ultimate stress were highest between 40 and 50 years, whereas ultimate strain and failure energy showed maxima at younger ages. These age-related variations (except for failure energy) were non-linear. Tissue density and mineral concentration were constant throughout life, whereas apparent density (the amount of bone) varied with ultimate stress. Collagen density (the amount of collagen) varied with failure energy. Collagen concentration was maximal at younger ages but varied little with age. Our results suggest that the decrease in mechanical properties of trabecular bone such as Young's modulus and ultimate stress is mainly a consequence of the loss of trabecular bone substance, rather than a decrease in the quality of the substance itself. Linear regression analysis showed that collagen density was consistently the single best predictor of failure energy, and collagen concentration was the only predictor of ultimate strain.
Earlier experimental and finite element studies notwithstanding, the load transfer and stress distribution in the pelvic bone and the acetabulum in normal conditions are not well understood. This hampers the development of orthopaedic reconstruction methods. The present study deals with more precise finite element analyses of the pelvic bone, which are used to investigate its basic load transfer and stress distributions under physiological loading conditions. The analyses show that the major part of the load is transferred through the cortical shell. Although the magnitude of the hip joint force varies considerably, its direction during normal walking remains pointed into the anterior/superior quadrant of the acetabulum. Combined with the fact that the principal areas of support for the pelvic bone are the sacro-iliac joint and the pubic symphysis, this caused the primary areas of load transfer to be found in the superior acetabular rim, the incisura ischiadaca region and, to a lesser extent, the pubic bone. Due to the 'sandwich' behavior of the pelvic bone, stresses in the cortical shell are about 50 times higher than in the underlying trabecular bone (15 to 20 MPa vs 0.3-0.4 MPa at one-legged stance). Highest intraarticular pressures are found to occur during one-legged stance and measured about 9 MPa. During the swing phase, these pressures decrease less than linearly with the magnitude of the hip joint force. Muscle forces have a stabilizing effect on the pelvic load transfer. Analysis without muscle forces show that at some locations stresses are actually higher than when muscle forces are included.
Due to both its shape and its structural architecture, the mechanics of the pelvic bone are complex. In Finite Element (FE) models, these aspects have often been (over)simplified, sometimes leading to conclusions which did not bear out in reality. The purpose of this study was to develop a more realistic FE model of the pelvic bone. This not only implies that the model has to be three-dimensional, but also that the thickness of the cortical shell and the density distribution of the trabecular bone throughout the pelvic bone have to be incorporated in the model in a realistic way. For this purpose, quantitative measurements were performed on computer tomography scans of several pelvic bones, after which the measured quantities were allocated to each element of the mesh individually. To validate this FE model, two fresh pelvic bones were fitted with strain gages and loaded in a testing machine. Stresses calculated from the strain data of this experiment were compared to the results of a simulation with the developed pelvic FE model.