Search PubMed⌕ Search

Biomedical subjects

M Dahlbom

Publications and source records attributed to M Dahlbom.

At least 19 recordsLinked to original sources

Pregnancy rates in lactating Holstein-Friesian cows after artificial insemination with sexed sperm.

The effects of artificial insemination (AI) using sexed sperm on pregnancy rates have seldom been studied in lactating dairy cows on commercial dairy farms. We evaluated pregnancy results after AI of 306 lactating dairy cows, of which 157 were inseminated with 2x10(6) frozen/thawed sexed sperm and 149 with 15x10(6) frozen/thawed unsexed sperm. The average pregnancy and calving rates were 21.0% and 20% for the sexed-sperm AIs and 46% and 45% for the unseparated control-sperm AIs respectively (p<0.001). The proportion of female calves derived from sexed-sperm AI was 82% compared with 49% for control AI (p<0.01). The proportion of live and healthy calves in single births was 100% for sexed-sperm AI and 97% for control AI (p>0.05). Our results indicate that AI with low-dose sexed sperm under field conditions in commercial dairy herds without oestrus synchronization results in significantly reduced pregnancy rates compared with normal-dose AI. Improved insemination strategies combined with increased sperm doses are needed before the use of sexed sperm can be of any significant benefit for the dairy and beef industry.

Animals↗

An improved analytical detector response function model for multilayer small-diameter PET scanners.

The optimization of spatial resolution is a critical consideration in the design of small-diameter positron emission tomography (PET) scanners for animal imaging, and is often addressed with Monte Carlo simulations. As a faster and simpler solution, we have developed a new analytical model of the PET detector response function, and implemented the model for a small single-slice, multilayer PET scanner. The accuracy of the model has been assessed by comparison with both Monte Carlo simulations and experimental measurements published in the literature. Results from the analytical model agreed well with the Monte Carlo method, being noise free and two to three orders of magnitude faster. The only major discrepancy was a slight underestimation of the width of the point spread function by the analytical method as inter-crystal scatter is neglected. We observed good agreement between the predictions of the model and experimental measurements. For two large-diameter scanners additional discrepancies were seen due to photon acollinearity, which is not considered in the model. We have shown that the simple and fast analytical detector response function model can provide accurate estimates of spatial resolution for small-diameter PET scanners, and could be a useful tool for several applications, complementing or cross-validating other simulation methods.

Algorithms↗

Impaired semen quality of AI bulls fed with moldy hay: a case report.

The daily quality control of semen at a Finnish artificial insemination (AI) bull station is based on subjective motility and sperm morphology of young bulls entering the semen collection program. Semen quality dropped suddenly in autumn 1998. During 5 consecutive months, the number of rejected ejaculates and discarded frozen semen batches due to poor motility increased, and the number of all forms of abnormal spermatozoa increased. However, for the accepted ejaculates, a 60 day nonretum rate was normal. The summer of 1998 in Finland was rainy, and the hay used in the AI station was visibly moldy. Immunoassay and gas chromatography-mass spectrometry (GC-MS) detected Fusarium mycotoxins HT-2 and T-2, but no zearalenone in the hay. Occurrence of mycotoxins such as T-2 and HT-2 in the moldy hay coincided with, and may have been responsible for the impaired semen quality in AI bulls. This case report will draw the attention to the possible hazards when feeding moldy hay.

Animal Feed↗

A novel automated fluorometric assay to evaluate sperm viability and fertility in dairy bulls.

The artificial insemination (AI) industry is in need of an objective and rapid, but inexpensive method to evaluate frozen thawed bull semen ejaculates. This study presents a new fluorescence method that uses an automatized fluorometer and fluorophore stain propidium iodide that stains only those cells with damaged membranes. The fluorescence of the semen sample and the totally killed subsample were measured simultaneously, and viability was calculated. Every semen batch was analyzed before use in AI. For fertility evaluation, the nonreturn rates (NR%) obtained from 92,120 inseminations with the analyzed batches were recorded from 166 bulls (436 batches). This study confirms a 3.9% better NR% for the Finnish Holstein-Friesian breed than for Finnish Ayrshire. There was a clear seasonality in NR%: it differed (5.3%) significantly, being best in summer to autumn (June to October) and lowest in winter (January to March). The fluorometer method was fast and easy. The correlation between the total number of viable spermatozoa in an insemination dose and field fertility was low but significant (r = 0.051, P = 0.016), suggesting that the plasma membrane integrity evaluation can serve as a cost-beneficial quality control method of frozen-thawed semen at bull stations.

Animals↗

Human pharmacokinetic and dosimetry studies of [(18)F]FHBG: a reporter probe for imaging herpes simplex virus type-1 thymidine kinase reporter gene expression.

UNLABELLED: 9-[4-[(18)F]fluoro-3-(hydroxymethyl)butyl]guanine ([(18)F]FHBG) has been used as a reporter probe to image expression of herpes simplex virus type-1 thymidine kinase (HSV1-tk) reporter gene in living animals. Our aim was to study the kinetics, biodistribution, stability, dosimetry, and safety of [(18)F]FHBG in healthy human volunteers, preparatory to imaging patients undergoing HSV1-tk gene therapy. METHODS: [(18)F]FHBG was synthesized with a specific activity of 37,000--444,000 GBq/mmol and a radiochemical purity > 99%. Ten healthy volunteers consented to participate in the study. A transmission scan was obtained before bolus injection of 70.3--229.4 MBq [(18)F]FHBG into a hand vein, followed by dynamic PET imaging with 4 consecutive emission scans. Warmed hand-vein blood was withdrawn at various times after injection for blood time--activity measurements. Electrocardiography, blood pressure, and blood and urine pharmacologic parameters were measured before and after injection of the [(18)F]FHBG tracer (n = 5). The stability of [(18)F]FHBG in the urine was analyzed. Attenuation-corrected images were reconstructed using the ordered-subsets expectation maximization algorithm. Image region-of-interest time-activity data were used with the MIRD program to estimate absorbed radiation dosages. RESULTS: [(18)F]FHBG had rapid blood clearance; only 8.42% +/- 4.76% (mean +/- SD) of the peak blood activity remained at approximately 30 min. The average ratio of plasma activity to whole-blood activity during the study was 0.91 +/- 0.04. Penetration of [(18)F]FHBG across the blood-brain barrier was not observed. The primary routes of clearance were renal and hepatobiliary. High activities were observed in the bladder, gut, liver, and kidneys, but <0.0002% of the injected dose per gram was observed in other tissues. In the urine, 83% of activity 180 min after injection was stable [(18)F]FHBG. Blood and urine pharmacologic parameters did not change significantly after injection of the [(18)F]FHBG tracer. The bladder absorbed the highest radiation dose. CONCLUSION: [(18)F]FHBG has the desirable in vivo characteristics of stability, rapid blood clearance, low background signal, biosafety, and acceptable radiation dosimetry in humans. This study forms the foundation for using [(18)F]FHBG in applications to monitor HSV1-tk reporter gene expression.

Adult↗

Phase I/II 90Y-Zevalin (yttrium-90 ibritumomab tiuxetan, IDEC-Y2B8) radioimmunotherapy dosimetry results in relapsed or refractory non-Hodgkin's lymphoma.

Dosimetry studies in patients with non-Hodgkin's lymphoma were performed to estimate the radiation absorbed dose to normal organs and bone marrow from 90Y-Zevalin (yttrium-90 ibritumomab tiuxetan, IDEC-Y2B8) treatment in this phase I/II, multicenter trial. The trial was designed to determine the dose of Rituximab (chimeric anti-CD20, Rituxan, IDEC-C2B8, MabThera), the unlabeled antibody given prior to the radioconjugate to clear peripheral blood B cells and optimize distribution, and to determine the maximum tolerated dose of 90Y-Zevalin [7.4, 11, or 15 MBq/kg (0.2, 0.3, or 0.4 mCi/kg)]. Patients received (111)In-Zevalin (indium-111 ibritumomab tiuxetan, IDEC-In2B8 ) on day 0 followed by a therapeutic dose of 90Y-Zevalin on day 7. Both doses were preceded by an infusion of the chimeric, unlabeled antibody Rituximab. Following administration of (111)In-Zevalin, serial anterior/posterior whole-body scans were acquired. Major-organ radioactivity versus time estimates were calculated using regions of interest. Residence times were computed and entered into the MIRDOSE3 computer software program to calculate estimated radiation absorbed dose to each organ. Initial analyses of estimated radiation absorbed dose were completed at the clinical site. An additional, centralized dosimetry analysis was performed subsequently to provide a consistent analysis of data collected from the seven clinical sites. In all patients with dosimetry data (n=56), normal organ and red marrow radiation absorbed doses were estimated to be well under the protocol-defined upper limit of 20 Gy and 3 Gy, respectively. Median estimated radiation absorbed dose was 3.4 Gy to liver (range 1.2-7.8 Gy), 2.6 Gy to lungs (range 0.72-4.4 Gy), and 0.38 Gy to kidneys (range 0.07-0.61 Gy). Median estimated tumor radiation absorbed dose was 17 Gy (range 5.8-67 Gy). No correlation was noted between hematologic toxicity and the following variables: red marrow radiation absorbed dose, blood T(1/2), blood AUC, plasma T(1/2), and plasma AUC. It is concluded that 90Y-Zevalin administered at nonmyeloablative maximum tolerated doses results in acceptable radiation absorbed doses to normal organs. The only toxicity of note is hematologic and is not correlated to red marrow radiation absorbed dose estimates or T(1/2), reflecting that hematologic toxicity is dependent on bone marrow reserve in this heavily pretreated population.

Antibodies, Monoclonal↗

A comparison of normalization effects on three whole-body cylindrical 3D PET systems.

Normalization coefficients in three-dimensional positron emission tomography (3D PET) are affected by parameters such as camera geometry and the design and arrangement of the block detectors. In this work, normalization components for three whole-body 3D-capable tomographs (the GE Advance, the Siemens/CTI962/HR+ and the Siemens/CTI951R) are compared by means of a series of scans using uniform cylindrical and rotating line sources. Where applicable, the manufacturers' normalization methods are validated, and it is shown that these methods can be improved upon by using previously published normalization protocols. Those architectural differences between the three tomographs that affect normalization are discussed with a view to drawing more general conclusions about the effect of machine architecture on normalization. The data presented suggest that uniformity of system response becomes easier to achieve as the uniformity of crystal response within the detector block is improved.

Humans↗

Web-based video for real-time monitoring of radiological procedures.

A web-based video transmission of images from CT and MRI consoles was implemented in an Intranet environment for real-time monitoring of ongoing procedures. Images captured from the consoles are compressed to video resolution and broadcast through a web server. When called upon, the attending radiologists can view these live images on any computer within the secured Intranet network. With adequate compression, these images can be displayed simultaneously in different locations at a rate of 2 to 5 images/s through a standard local-area network. While the quality of the images was insufficient for diagnostic purposes, our users survey showed that they were suitable for supervising a procedure, positioning the imaging slices, and for routine quality checking before completion of a study. The system was implemented at UCLA to monitor nine CT's and six MRI's distributed in four different buildings. This system significantly improved the radiologists productivity by saving valuable time spent in trips between reading rooms and examination rooms. It also improved patient care and throughput by reducing the time spent waiting for the radiologists to check a study before removing the patient from the scanner.

Internet↗

Morphometry of normal and teratozoospermic canine sperm heads using an image analyzer: work in progress.

Combining the traditional morphologic evaluation of spermatozoa with computer assisted image analysis adds randomness, objectivity, repeatability and accuracy to morphometric measurements. We collected semen from 10 fertile, normospermic dogs aged 1 to 7 yr and from 3 teratozoospermic breed-matched dogs. Sperm head morphology was examined in Giemsa-stained smears by light microscopy, using a computer-assisted image analyzer and by transmission electron microscopy. We found significant variation in sperm head area, length, width and degree of roundness among normospermic individual dogs, indicating that it would be necessary to examine many more dogs before the size and shape of normal dog spermatozoa could be determined. The normospermic dogs were used as controls for the teratozoospermic cases. Case 1: A 2-yr-old subfertile Cavalier King Charles Spaniel had semen with small and narrow-based sperm heads and a proximal cytoplasmic droplet in most of the spermatozoa. With the image analysis system, sperm heads were shown to be smaller and more oval than in normospermic dogs. The variatons in size and shape were similar in magnitude to those of control dogs. An examined infertile half-brother had similar semen quality. Case 2: A 3-yr-old Petit Basset Griffon Vendeen with 2 unsuccesfull matings exhibited spermatozoa with severe abnormalities. Measured by image analyzer, sperm heads were irregular in shape and very small in area. One of the two littermates examined had semen of the same quality as the case dog. Case 3: A 3-yr-old fertile Golden Retriever had semen with giant sperm heads in about 50% of spermatozoa. Image analyzing results revealed 2 populations of different sized sperm heads. Giant heads consisted of 52.2% of all spermatozoa. The results of the study reported here suggest that the image analysis technique may be useful in evaluating structural changes in sperm morphology, supplementing visual assessment that is used in conventional methods.

Journal Article↗

Testicular fine needle aspiration cytology as a diagnostic tool in dog infertility.

The results of testicular aspirate cytology taken from clinical patients with a history of infertility were compared with the clinical and histological findings. Azoospermia was the most common and the most rewarding indication for the examination. Samples were also taken from cases with suspected testicular tumours, orchitis, epididymitis, severe oligo- and teratozoospermia, lack of libido and unilateral testicular atrophy. Histological and cytological findings were found to correlate well. Identification of cell types from normal germinal epithelium was relatively easy. No immediate adverse effects of aspiration were noted. Five normospermic dogs were monitored for two to six months after aspiration, and there were no marked deleterious effects on testicular consistency, testicular histology or semen characteristics. Testicular cytology obtained by fine needle aspiration may, at least to some extent, be used to assist clinical diagnosis, especially in azoospermic dogs and dogs with palpable changes of testicular tissue.

Animals↗

Fertility parameters in male Irish wolfhounds: a two-year follow-up study.

The reproductive performance of 25 male Irish wolfhounds was examined in a two-year follow-up study. Results of a previous study showed that 37 Irish wolfhounds had lower libidos, smaller testicles and poorer semen quality than 67 control dogs examined. This study was undertaken to determine whether fertility parameters had changed after a further two years. Forty-four dogs of 21 breeds were used as controls. No change in libido was observed in either group after two years; the Irish wolfhounds still exhibited lower libidos than the control dogs. In both studies, the Irish wolfhounds showed a softening of testicular tissue with a significantly higher incidence than control dogs. This difference became more marked after two years. Semen quality had declined in Irish wolfhounds and the differences between the two groups became more accentuated. Inbreeding coefficients for the Irish wolfhounds were low, suggesting that this was a factor contributing to the poor reproductive function. However, several Irish wolfhounds had been ill during the follow-up period which, together with the decline in reproductive efficiency, may reflect a change due to ageing.

Aging↗

Whole-body FDG-PET imaging for staging of Hodgkin's disease and lymphoma.

UNLABELLED: Accurate staging of Hodgkin's disease (HD) and non-Hodgkin's lymphoma (NHL) is important for treatment management. In this study, the utility of 2-[18F]fluoro-2-deoxy-D-glucose (FDG) whole-body PET was evaluated as an imaging modality for initial staging or restaging of 7 HD and 11 NHL patients. METHODS: Whole-body PET-based staging results were compared to the patient's clinical stage based on conventional staging studies, which included combinations of CT of the chest, abdomen and pelvis, MRI scans, gallium scans, lymphangiograms, staging laparatomies and bone scans. RESULTS: Accurate staging was performed in 17 of 18 patients using a whole-body PET-based staging algorithm compared to the conventional staging algorithm in 15 of 18 patients. In 5 of 18 patients, whole-body PET-based staging showed additional lesions not detected by conventional staging modalities, whereas conventional staging demonstrated additional lesions in 4 of 18 patients not detected by whole-body PET. The total cost of conventional staging was $66,292 for 16 CT chest scans, 16 CT abdominal/pelvis scans, three limited MRI scans, four bone scans, five gallium scans, two laparotomies and one lymphangiogram. In contrast, scans cost $36,250 for 18 whole-body PET studies and additional selected correlative studies: one plain film radiograph, one limited CT, one bone marrow scan, one upper GI and one endoscopy. CONCLUSION: A whole-body FDG-PET-based staging algorithm may be an accurate and cost-effective method for staging or restaging HD and NHL.

Adolescent↗

Simultaneous dual-isotope technetium-99m/thallium-201 cardiac SPET imaging using a projection-dependent spilldown correction factor.

A spilldown correction method is proposed for the thallium-201 window image in simultaneous dual-isotope technetium-99m/thallium-201 single-photon emission tomographic (SPET) imaging based on a single acquisition into three energy windows. In this method, images are simultaneously acquired in two standard energy windows over the 99mTc and 201Tl photopeak regions and a third spilldown window adjacent to the 201Tl window. Using a Monte Carlo simulation of SPET, the fractional amount of 99mTc and 201Tl spilldown in the 201Tl window with respect to the total counts from the spilldown window, k12, was calculated for simulated images of point sources at varying depths within a water-filled elliptical tub phantom. When applied to experimental acquisitions, k12, multiplied by the total counts from the spilldown window, is then subtracted from the 201Tl window image to produce the corrected image. However, for successful applications in SPET, k12 must be determined on a projection-by-projection basis since k12 is depth dependent. Thus, a regression relation was obtained between k12 and the total count ratio of the spilldown to 99mTc windows, k23. The spilldown correction method was applied to 201Tl photopeak images of an extended source distribution in uniform and nonuniform attenuating media with dual-isotope 99mTc/201Tl and single-isotope 201Tl. A marked improvement in image contrast was observed between the corrected and uncorrected 201Tl window images. The average count ratio of uncorrected dual-isotope 201Tl/single-isotope 201Tl was 3.08 for uniform and 2.99 for non-uniform attenuating media.(ABSTRACT TRUNCATED AT 250 WORDS)

Heart↗

Poor semen quality in Irish wolfhounds: a clinical, hormonal and spermatological study.

On the basis of clinical observations, Irish wolfhounds were suspected as being subject to a relatively high incidence of soft testicular consistency and low semen quality. Thirty-seven Irish wolfhounds and 67 dogs of other breeds (control group) were therefore examined. Conventional andrological studies were performed in both groups, these included libido testing, palpation and measurement of testes and semen evaluation. Semen evaluation was performed both manually and by videomicrographic analysis. Testosterone concentrations were measured both before and after human chorionic gonadotropin challenge in the Irish wolfhounds. The Irish wolfhounds had lower libidos than the control group. More Irish wolfhounds (21.2 per cent) exhibited low semen quality than the control group (6.1 per cent). Soft testicular consistency occurred more frequently in Irish wolfhounds (25.7 per cent) than in the control group (10.5 per cent). In the control group, bodyweight correlated significantly with total sperm count. Serum testosterone concentration did not correlate with semen quality parameters.

Animals↗

Methodological aspects of brain activation studies: cerebral blood flow determined with [15O]butanol and positron emission tomography.

In this methodological study, a procedure for measuring regional CBF (rCBF) with positron emission tomography and 15O-labelled tracers is optimized. Four healthy volunteers were subjected to eight studies with use of [15O]butanol as a tracer: four times while reading aloud and four times while reading silently from a phonologically balanced list of single words. The gain from these repeated intra-individual studies of the same activation state (fractionation) was demonstrated in terms of noise-equivalent counts in a phantom study. A computerized brain atlas was used to reformat the images to a common anatomical representation, thereby minimizing the effects of inter- and intra-individual anatomical and positional variations. This allowed the formation of inter- and intra-individual average subtraction images with error estimates. Differences between the two activation states were detected with use of an exploratory significance map based on a paired Student's t test. The results compared well with Friston's method of determining levels of statistical significance. No difference was obtained when comparing results from rCBF images and images generated from measurement of uptake of the tracer. The paradigm chosen for activation was shown to yield a constant activation level during the repeated measurements (i.e., no habituation).

Brain↗

Basic principles of positron emission tomography in oncology: quantitation and whole body techniques.

Positron emission tomography (PET) of the brain and heart has made important contributions in clinical and research applications in the fields of neurology and cardiology. The more recent applications of PET in tumor imaging has marked oncology as the next frontier in PET; however, the dilemma of rising health care cost will challenge the application of new technologies. This challenge can be approached by innovative and appropriate use of sophisticated technology in both the research and clinical realms. The current developments of PET imaging technology to accurately stage the extent of tumor, as well as monitor the effectiveness or ineffectiveness of new or current therapies will be an extremely valuable tool in research and in the cost effective management of cancer patients. In the future, the oncologist may be able to adjust the chemotherapy to the tumor response based on PET imaging. In other situations, PET may be able to predict that no existing therapy will elicit a durable response, resolving the patients' and families' uncertainty of whether extreme therapeutic measures would have made a significant difference. This paper reviews some of the recent developments and areas of research in tumor PET imaging, and describes some of the practical and technical aspects involved with FDG tumor quantitation and whole body PET imaging.

Blood Glucose↗

Imaging of pulmonary mass lesions with whole-body positron emission tomography and fluorodeoxyglucose.

BACKGROUND: The clinical staging and management of both primary and metastatic lung lesions depends on accurate imaging techniques. Biochemical imaging with positron emission tomography, (PET), and the glucose analog 2-[18F]-fluoro-2-deoxy-D-glucose, (FDG), complements anatomic imaging with conventional radiologic methods. METHODS: A new "whole-body" PET FDG technique that produces two-dimensional, nontomographic and tomographic longitudinal images of the entire body has been developed at UCLA. Sixteen patients with known pulmonary nodules who had undergone thoracic computed tomography (CT) were studied with whole-body PET FDG imaging at the UCLA Medical Center. RESULTS: This PET FDG imaging method identified metabolically active tumor foci in all eight patients with bronchogenic carcinomas, four patients with metastatic lesions to the thorax, and two patients with Hodgkin disease. All diagnoses were confirmed histologically. Additionally, the PET FDG technique detected extrathoracic metastases in 4 of 16 patients. Thoracic CT was not diagnostic of neoplasm in two of the eight patients with bronchogenic carcinomas. In one patient with an ACTH-producing bronchial carcinoid, the lesion ultimately was detected on high-resolution CT but was not metabolically active on PET FDG imaging. CONCLUSIONS: This is the first report of whole-body PET FDG imaging in patients with thoracic lesions. PET FDG imaging accurately detected metabolically active tumor (both intrathoracic and extrathoracic) in patients with bronchogenic carcinoma, pulmonary metastatic disease, and Hodgkin lymphoma. Because lung cancer is characteristically a multisystem disease, this whole-body PET FDG technique has significant implications for treatment planning.

Adenocarcinoma↗

Automated iterative three-dimensional registration of positron emission tomography images.

Two types of image similarity measures, the sum of absolute differences (SAD) and the stochastic sign change (SSC), were compared for three-dimensional registration of images from PET. To test the accuracy of both registration methods, 30 FDG brain studies, 40 13N-ammonia cardiac studies and 20 FDG liver tumor studies (where each image set contained 15 image planes, 128 x 128 pixels per plane) were made into worse case conditions by creating image sets of low counts and extreme defects. These images were then registered to the reference images that had been moved in three dimensions into a random set of known translations, rotations and normalization factors (x, y, z, theta, rho, sigma, nf). Neither method required any external fiduciary markers or operator interventions to register a set of images. The optimization of the image similarity (using the SAD or SSC) was performed with the simplex method and registration was completed within 10 min of computation time on a low-end workstation. Overall, the SAD method had an average inplane (x, y) registration error of 0.5 +/- 0.5 mm, a z-axis registration error of 1.1 +/- 1.1 mm, an inplane rotational error of 0.5 +/- 0.4 degrees, an out-of-plane rotational error of 1.1 +/- 1.2 degrees and a normalization factor error of 0.015 +/- 0.016. The SSC method had an average inplane (x, y) registration error of 0.6 +/- 0.5 mm, a z-axis registration error of 1.1 +/- 1.1 mm, an inplane rotational error of 0.7 +/- 0.5 degrees, an out-of-plane rotational error of 1.0 +/- 1.2 degrees and a normalization factor error of 0.014 +/- 0.014. This study demonstrates that either the SAD or SSC method for measuring image similarity, combined with the simplex method for function optimization, are accurate methods for registration of a wide variety of PET images including low count studies and those with marked interval changes in the pattern of count distribution.

Brain↗