Third party office management.
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to M D White.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
The interaction of ApU, Aps4U, Aps4Up, ApAps4Up and Gps4U with RNase A was studied by CD difference spectroscopy. The use of 4-thiouridine (s4U) containing oligonucleotides enables to distinguish between the interaction of the different components of the ligand with the enzyme. The mode of binding of the oligonucleotides to the enzyme is described. From this mode of binding it is explained why Aps4U, for example, inhibits RNase A, while s4UpA serves as a substrate.
Forty different oligonucleotides were investigated as possible inhibitors of the depolymerizing activity of RNase A. The strongest inhibitors among the diribonucleoside 2'-5' mono- phosphates were: G2'-5'G, C2'-5'G and U2'-5'G, and among the diribonucleoside 3'-5' monophosphates: ApU, ApC and GpU. Of the eight trinucleotides investigated, ApApUp, ApApCp and ApGpUp were the strongest inhibitors. All four dinucleotides studied (ApUp, ApCp, GpUp and GpCp) were very strong inhibitors, ApUp being the strongest one. The results show that the nature of the various bases in the oligonucleotide has an effect on the degree of inhibition, and that the 3' phosphomonoester group increases the binding of the oligonucleotide to RNase A. These inhibitors can be used in physicochemical and biochemical studies of ribonuclease.
A ouabain-insensitive ATPase activity associated with the water-soluble proteins of the human and bovine erythrocyte membrane is demonstrated by means of activity-staining in polyacrylamide gels. The ATPase activity from both sources had an absolute requirement for Mg2+, activity becoming easily detectable at 0.2 mM Mg2+. At low Mg2+ concentrations added Ca2+ appeared to decrease the intensity of the ATPase stain. The activity is unaffected by monovalent cations, does not hydrolyse p-nitrophenyl phosphate and is not inhibited by 2 : 4 dinitrophenol. The ATPase has an apparent molecular weight of approximately 100 000 as determined by electrophoresis in acrylamide gels containing dodecyl sulphate.
An efficient method to grow Escherichia coli W to high cell concentrations on the pilot scale is described and discussed. The method involves growth linked introduction of glucose and ammonia to the culture, sparging with oxygen, and maintenance of aerobic conditions by gradually decreasing the temperature in the culture in order to keep the oxygen demand within the limits of the capacity of supply. Under these conditions the linear rate of cell mass production is actually the result of exponential growth with a gradually decreasing growth-rate constant. About 10 kg packed cells were produced in a 50 liter working-volume fermentor in one run of 13 hr. The concentration of the cells at the end of the growth was about 47 g dry cells/liter. The expenditure for nutrients was minimal and the controls were of simple automatic nature. From the determined yield constants for glucose, nitrogen, phosphorus, and oxygen it may be inferred that the cells grown by this method are similar to those grown exponentially at constant temperature.
A novel procedure for the separation of oligonucleotides from pancreatic RNase-digest of RNA is described. The method involves a group-separation of uracil-containing and of cytosine-containing nucleotides on Dowex 50W. The obtained groups are further separated on DEAE-Sephadex A-25 by a linear gradient of NH4HCO3.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Flow of nonvolatile nonaqueous phase liquid (NAPL) and aqueous phases that account for mobile, entrapped, and residual NAPL in variably saturated water-wet porous media is modeled and compared against results from detailed laboratory experiments. Residual saturation formation in the vadose zone is a process that is often ignored in multifluid flow simulators, which might cause an overestimation of the volume of NAPL that reaches the ground water. Mobile NAPL is defined as being continuous in the pore space and flows under a pressure gradient or gravitational body force. Entrapped NAPL is defined as being occluded by the aqueous phase, occurring as immobile ganglia surrounded by aqueous phase in the pore space and formed when NAPL is replaced by the aqueous phase. Residual NAPL is defined as immobile, nonwater entrapped NAPL that does not drain from the pore spaces and is conceptualized as being either continuous or discontinuous. Free NAPL comprises mobile and residual NAPL. The numerical model is formulated on mass conservation equations for oil and water, transported via NAPL and aqueous phases through variably saturated porous media. To account for phase transitions, a primary variable switching scheme is implemented for the oil-mass conservation equation over three phase conditions: (1) aqueous or aqueous-gas with dissolved oil, (2) aqueous or aqueous-gas with entrapped NAPL, and (3) aqueous or aqueous gas with free NAPL. Two laboratory-scale column experiments are modeled to verify the numerical model. Comparisons between the numerical simulations and experiments demonstrate the necessity to include the residual NAPL formation process in multifluid flow simulators.
Clinical laboratories and clinicians transmit certain laboratory test results to public health agencies as required by state or local law. Most of these surveillance data are currently received by conventional mail or facsimile transmission. The Centers for Disease Control and Prevention (CDC), Council of State and Territorial Epidemiologists, and Association of Public Health Laboratories are preparing to implement surveillance systems that will use existing laboratory information systems to transmit electronic laboratory results to appropriate public health agencies. The authors anticipate that this will improve the reporting efficiency for these laboratories, reduce manual data entry, and greatly increase the timeliness and utility of the data. The vocabulary and messaging standards used should encourage participation in these new electronic reporting systems by minimizing the cost and inconvenience to laboratories while providing for accurate and complete communication of needed data. This article describes public health data requirements and the influence of vocabulary and messaging standards on implementation.