Search PubMed⌕ Search

Biomedical subjects

M D Short

Publications and source records attributed to M D Short.

At least 19 recordsLinked to original sources

Selenazolidines as novel organoselenium delivery agents.

Two new classes of selenazolidine-4(R)-carboxylic acids (2-oxo and 2-methyl-SCAs) were synthesized and characterized. Both were designed as latent forms of selenocysteine, intended to provide a chemically superior delivery form for selenium. The prodrugs may be clinically useful when selenium supplementation at supranutritional levels is indicated, such as in cancer chemoprevention.

Organoselenium Compounds↗

The effect of polyethylene glycol 400 on gastrointestinal transit: implications for the formulation of poorly-water soluble drugs.

PURPOSE: To assess the effect of polyethylene glycol 400 (PEG 400), a pharmaceutical excipient frequently employed to enhance the solubility and bioavailability of poorly water-soluble drugs, on the gastrointestinal transit of liquid and pellet preparations in human subjects using gamma scintigraphy. METHODS: Ten, healthy male volunteers each received, on separate occasions, a liquid preparation consisting of 150 ml orange juice (control) or 150 ml orange juice containing 10 g PEG 400 (test). Non-disintegrating pellets of size 1.4-1.7 mm. encapsulated within a hard gelatin capsule, were simultaneously administered on both occasions to act as a marker for solid dosage form transit. The liquid and pellet preparations were radiolabelled with 111In and 99mTc respectively thus enabling their positions within the gastrointestinal tract to be followed using a gamma camera. RESULTS: Rapid liquid emptying from the stomach was observed, with no significant difference noted in the gastric residence times of the two preparations. Caecum arrival times for the liquid preparations were significantly different by virtue of their differential rates of transit through the small intestine. The mean small intestinal liquid transit time for the control preparation was 236 min whereas the corresponding value for the PEG 400-containing test preparation was 153 min. This 35% reduction in transit time was attributed to the presence of PEG 400. Pellet transit was largely unaffected by the presence of PEG 400. CONCLUSIONS: These findings clearly demonstrate that PEG 400 has a marked accelerating effect on small intestinal liquid transit, which in turn has implications for the formulation of poorly water-soluble drugs with PEG 400.

Adult↗

Radiation safety of the sentinel lymph node technique in breast cancer.

Many publications attest to the potential of the sentinel lymph node technique in advancing the clinical management of melanoma and, more recently, breast cancer. Whilst not yet universally regarded as the standard of care, the technique is gaining wide acceptance. Use of a radiolabelled colloidal tracer is central to optimising sensitivity, and this brings with it the need to address radiation safety issues relating to the use of radioactive materials in the operating theatre and pathology laboratory, and the generation of radioactive waste. The radiation dose to the patient should also be determined if the professional is to reassure the patient by placing this in its proper context. For the purpose of this investigation, biodistribution data were obtained from patient studies to quantify the migration of tracer beyond the injection site, thereby permitting a detailed assessment of the internal dosimetry of the tracer and the resulting radiation dose to the patient. Uptake of tracer in the sentinel nodes, reticulo-endothelial system and circulating blood was investigated. The radiation dose to surgical staff was recorded using whole-body monitors and extremity dosimeters worn at the fingers. Clinical waste in the operating theatre was monitored and the radioactive content of significantly contaminated items determined. The radiation dose to pathology staff was estimated from knowledge of the radioactive content of the specimens obtained and a study of work practices. Migration of tracer was found to be minimal, with greater than 95% retention at the injection site. The effective dose resulting to the patient was 2.1x10(-2) mSv/MBq, with a mean breast dose of 7.2x10(-1) mGy/MBq. A mean whole-body dose of 0.34 microSv was received by surgical staff per procedure, with a mean finger dose of 0.09 mSv (90 microSv). Radiation doses received by pathology staff will be predominantly below measurable levels and are likely to be negligible unless primary specimens from a large number of studies are analysed promptly upon their excision. At operation, surgical swabs can become significantly contaminated and have been found to contain up to 22% of the administered activity, dependent upon the surgical procedure performed. It is concluded that moderate activities of technetium-99m labelled tracer are administered to the patient, and the radiation risk to the patient is consequently low relative to that from many other medical exposures. The radiation doses to staff groups involved in all aspects of the technique are low, and under normal circumstances and levels of workload, routine radiation monitoring will not be required. Standard biohazard precautions prevent direct intake of radioactive contamination. Radioactive waste is created in the operating theatre, and may be generated in the pathology laboratory if specimens are not routinely stored until fully decayed. This will require special handling if the disposal of radioactive material is not permitted.

Breast Neoplasms↗

A reappraisal of current methods for the assessment of planar gamma camera performance.

This study reappraises the acquisition parameters defined by three current protocols for the specification of planar gamma camera performance. These are the manufacturer Standards of the National Electrical Manufacturers' Association [1] and the International Electrotechnical Commission [2], and the user-orientated protocol of the UK Department of Health (DoH, formerly DHSS) Gamma Camera Performance Assessment Group [3]. The study looks specifically at three major planar performance characteristics: intrinsic non-uniformity, intrinsic spatial resolution and intrinsic non-linearity (spatial distortion). Acquisition parameters specified for these characteristics are investigated by testing a range of values for each parameter around those figures currently advocated by the three protocols. Those acquisition parameters which may be relaxed without loss of data integrity are identified and the adoption of revised parameters for some measurements within the DoH assessment protocol is suggested. Reviewing the data obtained, observations are made regarding the accuracy of some tests performed regularly for quality control purposes. The feasibility and advantages of incorporating some suitably modified DoH performance assessment tests within a routine quality assurance protocol for the gamma camera are also discussed.

Gamma Cameras↗

Lung deposition patterns of directly labelled salbutamol in normal subjects and in patients with reversible airflow obstruction.

BACKGROUND--Earlier studies of aerosol deposition in the lungs have relied on indirect labelling of Teflon spheres of a similar size distribution to the drug in question and have assumed similar aerodynamic properties. Using a modification of a new technique for directly labelling salbutamol, the deposition of salbutamol within the lungs of normal subjects and patients with asthma has been studied with the use of a metered dose inhaler (MDI) alone, an MDI with a spacer device, and a dry powder inhaler (DPI). METHOD--Salbutamol was directly labelled with technetium-99m and placed in an MDI or DPI. Ten normal subjects and 19 patients with asthma inhaled 200 micrograms of salbutamol by means of the MDI alone, the MDI with a spacer device attached, and by DPI on separate days. Deposition was assessed by a dual headed gamma camera after inhalation of the drug. RESULTS--The total mean (SD) percentage deposition of the drug in the normal subjects was 21.6% (8.9%) with the MDI alone, 20.9% (7.8%) with the MDI with spacer, and 12.4% (3.5%) with the DPI. For the patients, the mean percentage deposition was 18.2% (7.8%) with the MDI alone, 19.0% (8.9%) with the MDI and spacer, and 11.4% (5.0%) with the DPI. Bronchodilatation achieved by the patients was similar with all three techniques. Mean peripheral lung deposition was significantly greater with a spacer device than when the MDI was used alone in both normal subjects (49.4% (6.1%) v 44.1% (9.9%)) and patients (38.6% (11.1%) v 30.4% (9.4%)). CONCLUSIONS--The deposition of directly labelled salbutamol from an MDI is greater than previously estimated by indirect labelling techniques. The deposition of labelled salbutamol from a DPI, however, is little different from that measured by indirect techniques.

Adult↗

Preoperative imaging of colorectal cancers. Targeting the epithelial membrane antigen with a radiation-labeled monoclonal antibody.

The epithelial membrane antigen (EMA) is expressed by the majority of colorectal cancers but has not previously been investigated as a target for radiation-labeled monoclonal antibodies (MoAb) in the imaging of patients with colorectal cancer. A rat IgG2a MoAb that recognizes EMA, ICR2, was labeled with Indium-111 (100 megabecquerel per milligram [MBq/mg]MoAb) using the bicyclic anhydride of the chelating agent diethylene triamine pentacetic acid (ccDTPA) and was administered intravenously to 22 patients known to have or thought to have colorectal cancer. Daily gamma camera imaging was performed for 3 days during the time between the administration of the radiation-labeled antibody and surgical procedure. At operation, the biopsies were done of the tumors and the normal colon, and the uptake of radiation-labeled MoAb was measured in a gamma well-counter. Immunocytochemistry for EMA expression also was done on resected tumors. Independent unblinded and blinded reporting was done on all scans. The sensitivity of 111In-ICR2 for detecting cancers preoperatively was 80% and 60%, respectively, on unblinded and blinded reporting, and the corresponding specificity 20% and 60%. The low unblinded specificity was attributable to a false-positive localization in severely dysplastic benign tumors (n = 2) and inflammatory tissue (n = 2). Liver metastases present in three patients were cold relative to normal liver. Lymph node metastases were localized in 1 of 6 patients preoperatively. The mean absolute uptake of 111In-ICR2 in tumor tissue was 7.75 +/- 3.77 x 10(-3) percent of injected dose per gram, and the ratio to normal colon was 2.10 +/- 0.92:1. On immunohistochemistry, EMA was expressed by 16 of the 17 primary cancers, both dysplastic adenomas, and all nodal metastatic deposits. EMA-negative tumors (1 cancer + 1 colonic lipoma) had negative antibody scans, and patients whose tumor was negative or only focally positive for EMA expression had lower tumor/normal colon ratios of radioactivity (1.30 +/- 0.26 versus 2.45 +/- 0.65, P = 0.005) on gamma well-counting of excised specimens. These results suggest a possible role for 111In-ICR2 in the detection of colorectal cancer and metastases but not its liver deposits.

Aged↗

Stomach outline visualization in gastrointestinal transit studies using scintigraphy.

A major disadvantage of gamma scintigraphy in gastrointestinal transit studies is the inability to provide adequate delineation of anatomical details. As an aid to the important requirement of outlining the stomach to ensure accurate quantification of the time at which material empties from this organ, a new technique is described, using short half-life 81mKr gas to provide clearer identification of the stomach outline and position.

Gastrointestinal Transit↗

Intraoperative localization of colorectal cancers using radiolabelled monoclonal antibodies.

Radiation detectors may allow the intraoperative localization of small cancer deposits following administration of radiolabelled tumour-associated antibodies. This technique was evaluated in 16 patients with colorectal tumours (14 cancers, one adenoma, one lipoma) with the 111In-labelled monoclonal antibody (MAb) ICR2 which recognizes the tumour-associated epithelial membrane antigen (EMA). At operation counting was carried out (3 x 20 s per site) using a hand-held radiation probe over the primary lesions and any palpable lymph nodes in the mesocolon. The tumour to normal colon (T/NC) ratio of counts recorded at operation was more than 1.5:1 in eight of the 14 patients with cancer (mean(s.d.), 1.54(0.41):1) and 0.91:1 and 1.06:1 respectively in the two patients with benign tumours. Node to normal colon ratios were higher in lymph nodes containing metastases. The uptake of radiolabelled antibody (T/NC ratio) was higher in EMA-expressing cancers than in those not expressing the target antigen (mean(s.d.), 2.45(0.65):1 versus 1.40(0.20):1, P = 0.019). An abdominal tumour model was also developed. Radioactively filled containers of 0.5-10 ml representing tumour deposits were suspended in a tank of 111In solution representing the background activity found in normal tissues. The ratio of radioactivity in the 'tumour' to that of background varied from 2:1 to 8:1. The 'tumour' was considered to be detectable if the mean counts recorded over the 'tumour' exceeded the mean of counts recorded over background by three standard deviations. At a ratio of 2:1 only 'tumours' greater than 5 ml could be detected with a sodium iodide probe and those over 10 ml could be detected with a cadmium telluride (CdTe) probe. At a ratio of 8:1, 'tumours' of 0.5 ml could be detected with either probe. At all ratios and counting periods the NaI probe was more sensitive than the CdTe.

Aged↗

Evaluation of a technique for the intraoperative detection of a radiolabelled monoclonal antibody against colorectal cancer.

Occult tumour deposits may be localised at operation with a radiation detecting probe following the administration of a radiolabelled monoclonal antibody (MoAb) recognising a tumour-associated antigen. We have recently evaluated the clinical usefulness of this technique in detecting primary colorectal tumours targetted with an indium-111 MoAb. In the present study the physical characteristics of the two detector systems used were investigated; a sodium iodide [NaI(Tl)] scintillation detector and a cadmium telluride (CdTe) semiconductor probe. Limitations of the technique in use have been examined by testing the statistical significance of tumour detection using an abdominal phantom based on the currently available clinical biodistribution data for tumour uptake of radiolabelled MoAbs. The effect of tumour volume, antibody uptake, collimation and counting conditions was examined. Results indicate that tumours of 10 ml volume may be detected with the NaI(Tl) probe at the lowest levels of radiolabelled antibody uptake currently reported in the literature but that at higher published levels, lesions as small as 1 ml may be identified with both detector systems. Detector sensitivity and limited antibody specificity restrict the usefulness of the technique, although moderate improvements in tumour uptake may allow the detection of tumour deposits not clinically apparent. The statistical significance criterion used for this study could be an accurate and reliable indicator for tumour detection in vivo.

Colorectal Neoplasms↗

The short-term effects of reducing elevated blood pressure in elderly patients with propranolol and dyazide.

Propranolol and Dyazide (25 mg hydrochlorothiazide and 50 mg triamterene) were used singly to reduce the elevated blood pressure (systolic ranging from 170 to 271 mmHg and diastolic ranging from 100 to 141 mmHg) of 38 elderly hypertensive patients whose ages ranged from 69 to 91 years. Each compound was administered for a period of four weeks with a wash-out period of four weeks in between. The following parameters were assessed before and after each treatment period: cerebral blood flow (CBF), mental functions, cardiac output (CO), electrocardiogram, glomerular filtration rate (GFR) and serum biochemistry. Both systolic and diastolic blood pressure were significantly reduced following the administration of either compound. No significant change in CBF and CO could be observed after reducing the blood pressure whether Propranolol or Dyazide was used. The GFR was, however, significantly reduced and the plasma creatinine significantly increased following Dyazide but not Propranolol administration. As expected the administration of the latter compound was associated with a significant bradycardia. No significant change could be observed in the other parameters studied.

Aged↗

Which gamma camera?

Performance data on seven currently available gamma cameras have been presented. Where appropriate, results from both the DHSS and NEMA are included. It should be emphasized that no 'best buy' exists for all types of nuclear medicine application and that the performance figures presented in this paper must be interpreted in the light of clinical priorities. No mention has been made of optional extras for a camera system, long-term system reliability, availability of efficient servicing and last but not least, cost. Such details will no doubt be considered as important as the basic performance of the camera. Finally, continued improvements in gamma camera design and performance are likely to necessitate a further communication in the not too distant future.

Equipment Design↗

Direct labelling of ipratropium bromide aerosol and its deposition pattern in normal subjects and patients with chronic bronchitis.

A technique for the direct labelling of ipratropium bromide with bromine-77, with reconstitution of the drug in a metered dose inhaler so as to be identical to the commercial product, was used to study drug deposition patterns in seven normal subjects and seven patients with chronic bronchitis (mean FEV1 32% (SD 12.2%) predicted normal). The gamma camera image of the thorax was divided into a middle zone--the mediastinal zone--and the lung itself into a central zone comprising its medial third and a peripheal zone, the lateral two thirds. Measurements after 10 inhalations of labelled ipratropium bromide showed similar results for the two groups of subjects. The total lung dose inhaled was 11.2% of 203 micrograms and 11.7% of 186 micrograms in the normal subjects and the patients respectively. In contrast to the deposition patterns seen in aerosol studies using steady state inhalation methods, there was no difference in deposition pattern--that is, the distribution between the central and the peripheral lung zones--between the normal subjects and the patients with airways obstruction.

Adult↗

Long-term clearance of [57Co]cyanocobalamin in vegans and pernicious anaemia.

1. Whole-body counting has been used to monitor the clearance of [57Co]cyanocobalamin in normal subjects, vegans and patients with pernicious anaemia. After oral administration of 57Co-labelled cyanocobalamin (1 microgram/1 muCi), subjects were counted for radioactivity monthly for a maximum period of 1 year. 2. The results obtained were consistent with a monoexponential clearance model and a least squares fit showed that there was no significant difference between the mean clearance rates for the vegans and normal subjects. 3. The patients with pernicious anaemia cleared the vitamin significantly more quickly than the normal control subjects. 4. This may be due to failure to reabsorb biliary vitamin B12 in pernicious anaemia because of the absence of intrinsic factor.

Adolescent↗

Contribution of individual differences in gastric emptying to variability in plasma propranolol concentrations.

1 No correlation was found between the rate of gastric emptying and peak plasma propranolol concentrations in six hypertensive patients after single oral doses of 80 mg. 2 In four normal subjects given oral propranolol the peak plasma concentration was highest when a simultaneous injection of metoclopramide and lowest when propantheline was given. The mean time to peak was 1.5 h after metoclopramide, 2.8 h after normal saline and 4.5 h after propantheline. 3 Gastric emptying has some influence on the time of peak plasma propranolol concentrations but individual variation in its bioavailability is determined mainly by first-pass metabolism in the liver.

Administration, Oral↗

Femoral head activity in Perthes' disease: clinical evaluation of a quantitative technique for estimating tracer uptake.

A method for quantifying the uptake of Tc-99m-labeled phosphate complexes in the femoral head has been clinically evaluated, being used specifically for studying the uptake of these bone-seeking agents in Perthes' disease. The analysis depends on the selection, by computer program, of a reliable reference area in the femoral shaft, which is then compared with the mean uptake from each femoral head. The femoral-head activity is then represented as an uptake ratio. These ratios, together with a fixed contour representing the uptake in the femoral-head regions, provide more clinical information than the radiograph or scintiphoto, particularly in the early stages of unilateral or bilateral femoral-head disease and during followup. No correlation has been found between these ratios and qualitative techniques for assessing Perthes' disease by radiograph. From the quantitative data so far obtained it is clear that osteotomy reduces the vascularity of the femoral head, and in certain cases this reduction persists for some years. Tc-99m-labeled diphosphonate compounds were used in more recent studies, and a significant increase in sensitivity was obtained, compared with earlier polyphosphate data.

Child↗

A quantitative assessment of femoral head activity using 99Tcm -polyphosphate and a computer data collection system.

Abnormal femoral head activity in Legg-Calve-Perthes' disease has been measured using 99Tcm -polyphosphate and a gamma camera/computer data collection system. A reference point on the data matrix, which is unaffected by the diease, is used for deriving comparative uptake ratios in each femoral head. The reference point remains unaltered after surgical procedures or short intervals between follow-up studies. Early abnormality can be measured in both unilateral and bilateral femoral head pathology.

Child↗