Technical variables influencing the detection of acute deep vein thrombosis by magnetic resonance imaging.

To establish which technical variables influence the detection of deep vein thrombosis by magnetic resonance imaging, 2 dogs, 5 normal volunteers and 17 patients were studied using a 1.5 T whole-body system. A sequential slice gradient echo acquisition (TR 25, TE 13, 0 = 30 degrees, 2 NEX, flow compensation rephasing gradients) in the axial plane was found to be optimal for detecting venous thrombosis. Thus, when using appropriate technique, MRI may identify deep venous thrombosis accurately. It may also allow the diagnosis of conditions which may simulate venous thrombosis clinically since the most common of these, ruptured Baker's cyst, cellulitis, muscle tear, hematoma and external venous compression are all readily identified by MRI.

Acute Disease↗

Effect of lovastatin on intimal hyperplasia after balloon angioplasty: a study in an atherosclerotic hypercholesterolemic rabbit.

Restenosis, the major limitation of balloon angioplasty, is the result of intimal hyperplasia after the procedure. Lovastatin, a 3-hydroxy-3-methylglutaryl-coenzyme A (HMG-CoA) inhibitor, may influence intimal hyperplasia by lowering serum cholesterol and by blocking deoxyribonucleic acid (DNA) synthesis. To determine whether lovastatin reduces intimal hyperplasia, a prospective, randomized blinded study was performed in 60 atherosclerotic New Zealand White male rabbits. Atherosclerosis was produced by air desiccation injury followed by a 28 day diet of 2% cholesterol and 6% peanut oil that was terminated before balloon angioplasty was performed. Angioplasty could not be performed in 14 rabbits with bilateral femoral artery occlusion, and in one rabbit the procedure was a technical failure. Forty-five rabbits underwent balloon angioplasty performed with use of a 2.5-mm balloon inflated to 10 atm for three 1 min dilations at 1 min intervals. Seven rabbits died during the procedure. Thirty-eight rabbits were randomized to either a lovastatin group (6 mg/kg body weight per day) or a control group. Angioplasty was performed on all patent vessels (n = 54); the procedure was bilateral in 16 rabbits and unilateral in 22. Fifteen lovastatin-treated and 15 control rabbits survived 39 days after angioplasty and were then killed. Angiograms, obtained before and 10 min and 39 days after balloon angioplasty, were read with use of electronic calipers by two observers who had no knowledge of treatment data. After the rabbits were killed, vessels were pressure perfused using a standardized protocol to maintain in vivo dimensions for blinded quantitative histologic analysis.(ABSTRACT TRUNCATED AT 250 WORDS)

Angioplasty, Balloon↗

Onset of altered interventricular septal motion during cardiac surgery. Assessment by continuous intraoperative transesophageal echocardiography.

Abnormal motion of the interventricular septum is frequently observed after uncomplicated cardiac surgery. We sought to elucidate the mechanism underlying this phenomenon by using continuous echocardiographic imaging of the heart from a constant transesophageal location in 21 patients undergoing their first cardiac operation. Quantitative global and regional functional analyses were performed in each patient at baseline (stage 1), after median sternotomy (stage 2), after sternal retraction (stage 3), after pericardiotomy (stage 4), after completion of cardiopulmonary bypass (stage 5), and after chest closure (stage 6). During the first four surgical stages, mean left ventricular fractional shortening varied little among regions with a fixed reference system (maximum range, 31.6-39.2%; p = NS) but changed dramatically after the discontinuation of cardiopulmonary bypass (stage 5). The apparent medial hypokinesis that was observed (4.9 +/- 4.7% [SD]) was accompanied by lateral hyperkinesis (65.2 +/- 4.1%, p less than 0.0001). These regional differences were completely eliminated with a floating reference system (33.6 +/- 2.7% for medial, and 34.8 +/- 1.7% for lateral; p = NS), suggesting cardiac translation. Quantitative curvature analysis supported this conclusion, with preservation of baseline regional curvature seen throughout the procedure. The mean length of individual translational vectors (reflecting systolic movement of the endocardial centroid) remained minimal (less than or equal to 1.0 mm) through stage 4 but increased more than fourfold at stage 5, continuing in a medial direction after chest closure (5.2 +/- 3.0 mm and 271 +/- 6 degrees from anterior). Thus, abnormal postoperative septal motion is not caused by removal of restraining forces of the pericardium or anterior mediastinum but rather appears to be directly related to events occurring during cardiopulmonary bypass.

Cardiac Surgical Procedures↗

Vascular reactivity after balloon angioplasty in an atherosclerotic rabbit.

Alterations in vessel wall reactivity (VR) at or adjacent to the dilation site after balloon angioplasty (BA) may vary according to the inflation protocol and the time after angioplasty and may influence outcome. In 64 atherosclerotic rabbit femoral arteries, we evaluated VR after BA with intravenous ergonovine (ERGO) (40 micrograms/min for 5 minutes) and intra-arterial nitroglycerin (NTG) (2,500 micrograms single bolus) 24-72 hours and 28 days after BA. Comparisons were made with atherosclerotic, nonangioplastied, age-matched controls. BA was standardized to three 1-minute inflations, each 1 minute apart. For each balloon size, 2.5- (appropriate size) or 3.0-mm (oversized) vessels were allocated to either 5 or 10 atm inflation pressure. For the analysis, four groups were compared: Group 1, 3.0/5; group 2, 3.0/10; group 3, 2.5/5, and group 4, 2.5 mm/10 atm. Angiographic diameters were measured at, proximal, and distal to the lesion at baseline, 10 minutes after ERGO, and 5 minutes after NTG. Angiograms were measured with electronic calipers by two blinded observers. All segments of control vessels vasoconstricted to ERGO and vasodilated to NTG (p less than 0.05 versus baseline), indicating a normal response. At 24-72 hours after dilatation, the angioplasty sites for all inflation pressure/balloon size combinations were not responsive to either ERGO or NTG. All segments distal to the dilatation sites vasoconstricted to ERGO and dilated to NTG (p less than 0.05 versus baseline), indicating a normal response. Proximal segments of vessels dilated with a 2.5-mm balloon (appropriate size) responded positively to both stimuli (p less than 0.05). Those vessels dilated with a large balloon (3.0 mm) were nonreactive in the segment proximal to the angioplasty site. Twenty-eight days later angioplasty sites dilated with a 2.5-mm balloon (appropriately sized) regained reactivity; however, segments dilated with a large balloon (3.0 mm) remained unresponsive. All proximal segments, including those from vessels dilated with a large balloon, reacted positively. All distal segments reacted appropriately. Restenosis rates were not different between the over- and appropriately sized balloon groups. These data demonstrate that immediately after angioplasty, vessels lose reactivity at the dilatation site. Those vessels dilated with the smaller-size balloon (2.5 mm) regained reactivity. For large balloons, reactivity is not regained at 28 days. For segments proximal to the site of dilatation, transient loss of reactivity is seen only when a large balloon is used. Thus, acute closure originating at the site of dilatation is not a result of spasm.(ABSTRACT TRUNCATED AT 400 WORDS)

Angioplasty, Balloon↗

Comparison of platelet scintigraphy, impedance plethysmography gray scale and color flow duplex ultrasound and venography for the diagnosis of venous thrombosis.

The several techniques available for the diagnosis of venous thrombosis have not been directly compared in the same patient population. Thus color and gray scale duplex ultrasound (U), impedance plethysmography (IPG), 3-4 hr platelet imaging (PS) were compared to venography (V), in 104 consecutive patients (in hospital and out). PS and V were read by two, and IPG and U by one, blinded reader. Comparisons were made for the calf (CA), popliteal (Pop) and femoral (Fem) vessels. Reproducibility of V and PS was 84 and 87%. (table; see text) We conclude that PS, while having a very high specificity, has an unacceptably low sensitivity. However, while both impedance plethysmography and color flow ultrasound have excellent and similar diagnostic accuracy in the femoral, these techniques have either a low sensitivity or low technical success rate in the calf or popliteal veins.

Blood Platelets↗

Identifying left ventricular thrombi.

A number of imaging techniques are available for the identification of left ventricular thrombi. Echocardiography is the technique of choice because of its wide availability, noninvasiveness, and relative low cost. The accuracy of information from echocardiography depends on the skill of the technician and quality of equipment. Platelet scintigraphy, which reflects activity on the thrombus surface, plays a complementary role to echocardiography in detecting thrombi. Magnetic resonance imaging and computed tomography are potentially useful. Contrast ventriculography lacks sensitivity and specificity, and radio nuclide angiography lacks sensitivity in the diagnosis of left ventricular thrombi.

Blood Platelets↗

Early image acquisition after administration of indium-111 platelets in clinically suspected deep venous thrombosis.

Indium-111 platelet scintigraphy accurately detects acute deep venous thrombosis in asymptomatic high-risk patients and may be used as a surveillance test. However, its value in symptomatic patients and its accuracy early after platelet injection are not satisfactorily established. The latter is important for timely institution of therapy. Accordingly, 65 patients (67 limbs) with suspected deep venous thrombosis (symptom duration 8 +/- 10 days, mean +/- standard deviation) were prospectively studied with platelet scintigraphy and contrast venography. Platelets were labeled with 405 +/- 101 mCi indium-111 oxine. The labeling efficiency was 80 +/- 10%. All images were acquired within 120 minutes after intravenous administration of the platelet suspension. Both platelet scintigraphy and venography were interpreted independently by 2 blinded observers (for each technique). Five separate analyses were performed. Each scintigraphic reader was compared to each venographic reader. A fifth analysis--consisting of readings with blinded agreement of both readings of the platelet scans and both readings of the venograms--was performed. Interobserver agreement was 92% for venography and 79% for scintigraphy. Excluding anticoagulated patients, the sensitivity of platelet scintigraphy was between 38 and 46% and the specificity was between 92 and 100%. Thus, early imaging of labeled platelets for the diagnosis of symptomatic deep venous thrombosis carries a high specificity but a much lower sensitivity. It is speculated that the low sensitivity is related to the inactivity of the thrombus. This may suggest that early imaging will only be useful in patients whose symptoms are of recent onset.

Blood Platelets↗

Influence of inflation pressure and balloon size on the development of intimal hyperplasia after balloon angioplasty. A study in the atherosclerotic rabbit.

To evaluate the effect of balloon size and inflation pressure on acute and subsequent outcome following balloon angioplasty (BA), 70 New Zealand White rabbits with bilateral femoral atherosclerosis were assigned to four groups: group 1, oversized balloon, low inflation pressure (n = 35 vessels; balloon size, 3.0 mm/inflation pressure, 5 atm); group 2, oversized balloon, high inflation pressure (n = 36; 3.0 mm/10 atm); group 3, appropriate size, low inflation pressure (n = 17; 2.5 mm/5 atm); and group 4, appropriate size balloon, high inflation pressure (n = 19; 2.5 mm/10 atm). Angiograms were obtained before, 10 minutes after, and 28 days after BA and read by two blinded observers using electronic calipers. The in vivo balloon-to-vessel ratio was measured for each group. There were eight non-BA controls. Rabbits were sacrificed either immediately (n = 34) or at 28 days after BA (n = 36), with the femoral vessels pressure perfused for histologic and morphometric analysis. The latter was performed at 28 days only. Absolute angiographic diameters increased in all groups immediately after BA (p less than 0.01). Acute angiographic success, defined as greater than 20% increase in luminal diameter, was higher using high inflation pressure (group 2, 32/36 [89%] and group 4, 16/19 [84%] vs. group 1, 23/35 [66%] and group 3, 9/17 [53%]; p less than 0.05). A 3.0-mm balloon resulted in significant oversizing irrespective of inflation pressure (balloon-to-vessel ratio, 1.5 +/- 0.1 vs. 1.1 +/- 0.1 to 1, for the 2.5-mm balloon). Vessels exposed to high inflation pressure had a significantly higher incidence of mural thrombus, dissection (p less than 0.01), and medial necrosis versus low pressure (p less than 0.05). At 28 days, the rates of restenosis (defined as greater than 50% loss of initial gain) were 14/20 (70%), 11/16 (69%), 5/10 (50%), and 5/10 (50%) for groups 1 through 4 (p = NS; a trend in favor of the groups using an oversized balloon). There was an increase in the degree of intimal hyperplasia by morphometric analysis in all groups, being most marked in group 2 (oversized balloon and high inflation pressure, 1.7 +/- 0.9 vs. 0.5 +/- 0.2 mm for controls, p less than 0.001). We reached two conclusions. First, all protocols resulted in a significant increase in luminal diameter immediately after angioplasty with the highest success rate in vessels subjected to high pressure dilatation.(ABSTRACT TRUNCATED AT 400 WORDS)

Angiography↗

Demonstration of superior sagittal sinus thrombosis by indium-111 platelet scintigraphy.

Superior sagittal sinus thrombosis, documented by cerebral angiography, was demonstrated by indium-111 platelet scintigraphy in a 40-year-old man presenting with seizures and intracerebral hematoma. Early scintigraphy demonstrated focal increased indium-111 activity at the two ends of the thrombus, while later scintigraphy showed diffuse increased activity in the area of the sinus. This initial experience suggests that platelet scintigraphy may provide unique information regarding the natural history of intracranial venous thrombosis.

Adult↗

Potential application of labeled antibodies for thrombus detection.

Labeling platelets with monoclonal antibodies in whole blood for imaging thrombi is less cumbersome than the established 111In-oxine method.. 7E3, a murine monoclonal antibody directed against glycoprotein IIb and/or IIIa on both human and dog platelets was used to label canine platelets. Thrombi were induced by transcatheter placement of a copper coil followed by electrocoagulation. 7E3 was iodinated with 131I and labelled with 111In using 7E3-DTPA conjugate. Whole blood was incubated with 0.5-1.0 micrograms labeled 7E3/mL blood. In 4/4 dogs, experimental deep vein thrombi were identified using both 131I- and In 1/3 dogs, experimental coronary thrombus could be identified ex vivo at 4 h. Clot to blood ratios ranged between 7 to 13:1. Using the 111In-oxine method, 0/3 coronary thrombi were seen. Thus, 131I- and 111In-labeled 7E3 may be used to readily identify peripheral venous thrombi. For reliable and prompt identification of coronary thrombi, more rapid clearance of the labeled platelets is required.

Antibodies, Monoclonal↗

Indium-111 platelet scintigraphy for the diagnosis of acute venous thrombosis.

Platelets labeled with indium-111 have been used successfully as a marker of active thrombosis in man. To establish the diagnostic accuracy of platelet scintigraphy in comparison to contrast venography in the diagnosis of acute lower limb venous thrombosis, we evaluated 103 consecutive patients divided into two groups. Platelets were labeled by the indium-111 oxine method. Patients from group I (n = 73, 56 had venograms) were asymptomatic and underwent platelet scintigraphy 1.1 +/- 0.6 days (mean +/- 1 SD) after a major orthopedic procedure. Patients from group II (n = 30, all had venograms) were symptomatic and underwent platelet scintigraphy 1.2 +/- 1.7 days after venography. In group II, 15 patients with positive findings on contrast venography were treated with intravenous heparin; five others with positive venograms did not receive heparin until platelet scintigraphy was completed. Both platelet scintigraphy and contrast venography were evaluated by two blinded observers. Only studies with blinded agreement of both platelet scintigraphy and contrast venography were included in the analysis. Sensitivity and specificity of platelet scintigraphy for the whole limb were 93% and 97% in group I and 42% and 67% in group II. The lower sensitivity in group II was most likely attributable to therapy with heparin. These results demonstrate that platelet scintigraphy, a test that permits imaging for up to five days after a single injection, correlates favorably with contrast venography in patients who have not received heparin and may be used as a surveillance test in high-risk patients. The role of platelet scintigraphy in acutely symptomatic patients requires further evaluation.

Aged↗

Detection of platelet deposition at the site of peripheral balloon angioplasty using indium-111 platelet scintigraphy.

Restenosis after balloon angioplasty may be mediated through platelet deposition at the site of arterial dilatation. The purpose of this study was to determine whether platelet deposition at the site of dilatation could be detected using indium-111 platelet scintigraphy. Fifteen patients, aged 60 +/- 9 years, with iliac or femoral (n = 12), renal artery (n = 2) or distal aortic (n = 1) stenoses were studied. All patients received intravenous heparin at the time of dilatation. Labeled platelets containing 471 +/- 65 muCi indium-111 were injected 0.25 to 4 hours after dilatation and 1 to 24 hours after imaging. In 11 of 12 patients with iliac and femoral dilatations, focal uptake was demonstrated at the angioplasty site. In 4 patients (2 patients with renal, 1 patient with iliofemoral, and 1 with distal aortic stenoses), uptake at the dilatation sites was not detected. This preliminary study indicates that despite intravenous heparin, platelets accumulate at sites of balloon dilatation. Platelet scintigraphy may be useful in predicting sites of future narrowing after angioplasty and may be used to test the efficacy of antiplatelet therapy in retarding restenosis.

Adult↗

Effect of short-duration constant exercise on permeability of cockerel aorta to 125I-albumin.

To determine quantitatively the effect of short duration constant exercise on the rate of uptake (U) of intravenously injected 125I-labeled cockerel albumin (A) by the aorta of the adult cockerel, 24 birds divided into age-matched pairs, each pair consisting of an exercised and nonexercised control bird, were studied. The time period of heparinization, anesthesia, and time from injection of A (each member of each pair received about 50 microCi from the same batch) to the death of the animal (T) was identical for each member of each pair. The exercised animal was exercised at a constant speed of 3.2 kph at 0 degrees elevation for between 2 and 5 min on a treadmill. U was defined as accumulated wall radioactivity (dpm)/plasma radioactivity (dpm/ml) X endothelial surface area (cm2) X T (s). Free 125I in the injectate amounted to 1.29 +/- 0.31% (mean +/- SD). Free 125I in the plasma and the wall in the exercise and control animals was not significantly different: plasma 0.84 +/- 0.34% (mean +/- SD) and 0.55 +/- 0.18 (P less than 0.20); wall 3.38 +/- 5.64% and 6.42 +/- 4.72 (P less than 0.04). Injected A remaining in the blood at between 8 and 16 min after intravenous injection was 83 +/- 8.7% (n = 10) in the exercised and 82 +/- 10% (n = 7) in the control (P less than 0.2). U was greater in the exercise group in 9 out of 12 matched pairs (P less than 0.05). We conclude that U increases for short periods of constant exercise.

Animals↗

Vasoactive intestinal polypeptide in cardiac myxoma.

A case of left atrial myxoma is reported in which tumor tissue was found to contain high levels of vasoactive intestinal polypeptide. This finding further supports the concept that myxomas are true neoplasms and may explain some of the poorly understood clinical manifestations of this tumor.

Female↗