Diagnosis of cerebral ventriculomegaly in normal adult beagles using quantitative MRI.

The brain of 17 asymptomatic normal adult beagles was evaluated with magnetic resonance imaging. Lateral ventricular size was quantified using computer algorithms. In beagles with large ventricles, contrast medium was introduced into the cerebellomedullary cistern to determine whether obstructive hydrocephalus was present. Total lateral ventricular volume ranged from 77 mm3 to 11,726 mm3. Based on Gd-DTPA diffusion, the CSF flow pattern was considered normal and normal neural morphology was seen using electron microscopy. Results suggest a high incidence of clinically asymptomatic ventriculomegaly in normal adult beagles.

Animals↗

The effects of CT drift on xenon/CT measurement of regional cerebral blood flow.

A systematic increase in computed tomography (CT) number of approximately 0.13 Hounsfield unit per scan (HU/scan) was observed when serial DeltaScan 2020 CT scans of a uniform water phantom were equally spaced at 0.5, 1.0, or 2.0 min and a shaped aluminum beam-hardening filter was employed. Much smaller drifts (less than 0.06 HU/scan) were observed with flat aluminum or shaped beryllium oxide filters. This machine drift, which was not associated with a rise in water phantom temperature and did not consistently correlate with estimated x-ray tube heat, could result in a significant overestimation of regional cerebral blood flow (rCBF) for a xenon/CT rCBF protocol involving 5-7 sequential scans obtained at 1-min interscan intervals.

Brain↗

A survey of postsecondary programs for students with learning disabilities.

Four-year colleges and universities identified as offering special programs for post-secondary students with learning disabilities were surveyed to determine the types of services provided. Results related to students served, assessment and referral procedures used, academic and nonacademic services offered, and procedures employed for staff training are discussed in this article.

Achievement↗

Failure of CT scan to detect ischemic lesions in patients with dementia.

Although clinical series have described relatively high accuracy in the ability of computed tomographic (CT) scan to detect significant cerebrovascular damage in patients with dementia, a recent neuropathologically controlled study failed to document that relationship. We now present clinical, neuroradiologic (CT), and neuropathologic information on four patients in whom CT scans did not contribute to the diagnosis of multi-infarct dementia or mixed dementia, despite clinical and neuropathologic evidence of infarcts. In one patient, the failure of CT scan to detect ischemic lesions may be attributable to less sensitive neuroradiologic criteria in use at the time of the examination. In the other three, even neuroradiologic review after the pathology was known failed to reveal the infarcts. These observations suggest the advisability of caution in using CT scan as a criterion for the presence or absence of cerebrovascular damage in patients with dementia.

Aged↗

Maternal cocaine abuse: the spectrum of radiologic abnormalities in the neonatal CNS.

The purpose of this study was to determine the pattern and frequency of CNS abnormalities in the offspring of cocaine-abusing mothers. The study group consisted of a retrospective review of all neonates born or admitted to our neonatal intensive care unit over a 1-year period who met criteria for maternal cocaine abuse (43 patients). A control group (62 patients) was obtained from patients seen during the same interval and the cases were matched for gestational age and race. The radiologic studies were analyzed by two independent reviewers, and CNS abnormalities were assessed by means of sonography, CT, or MR. By matching the study and control groups for gestational age, we eliminated the higher frequency of prematurity. This allowed us to determine if maternal cocaine use was associated with any intracranial abnormalities other than those seen with prematurity. The frequency of intracranial hemorrhage, ventricular enlargement, and periventricular leukomalacia was not significantly different between the study and control groups. The frequency of cortical infarction was 17% in the study group and 2% in the control group. The frequency of major congenital malformation was 12% in the study group and 0% in the control group. All five of the congenital malformations seen were midline CNS abnormalities, particularly neural tube defects. It is postulated that the higher statistically significant frequency of stroke and congenital malformations in the babies of maternal cocaine abusers is related to vasospasm caused by cocaine when used in the third and first trimesters, respectively.

Brain↗

MR imaging of acute intracranial hemorrhage: findings on sequential spin-echo and gradient-echo images in a dog model.

Seven intraparenchymal hematomas (four venous and three arterial) were placed in the brains of six dogs in order to study the MR appearance of acute hemorrhage and to evaluate the effects of several variables on the signal intensity of the hematoma. MR imaging at 0.6 and 1.5 T was performed by using standard short and long TR spin-echo and low-flip-angle gradient-echo sequences. Sequential examinations were performed during the first week following hematoma creation. MR findings were compared with CT and postmortem examinations. Three patterns of signal intensity were observed, which varied according to the size (small vs large) and location (parenchymal vs intraventricular) of the hematomas. The small parenchymal hematomas did not undergo evolutionary changes. On short TR scans they were isointense at both field strengths, and therefore not detectable; on long TR scans these hematomas were of variable intensity at 1.5 T and were hyperintense at 0.6 T. On gradient-echo scans, they were hypointense at all times at both field strengths. The large parenchymal hematomas underwent evolutionary changes typical of those seen in clinical imaging. On short TR scans they were initially isointense and became hyperintense 1-3 days later. Long TR scans demonstrated initial hyperintensity, followed by the development of hypointensity within 12 hr in the venous hematomas and within 60 hr in the arterial hematoma. The intensity changes on long TR scans were seen at both 0.6 and 1.5 T, but occurred sooner and to a greater degree at 1.5 T. Gradient-echo imaging of these large lesions demonstrated hypointensity at all times at both field strengths. The intraventricular hemorrhages demonstrated more rapid development of hyperintensity on short TR scans and slower and less pronounced development of hypointensity on long TR scans compared with the parenchymal clots in the same animal. Gradient-echo imaging of the intraventricular hemorrhages demonstrated hypointensity at all times at both field strengths. A multifactorial hypothesis is proposed to explain the differences in intensity between venous, arterial, and intraventricular blood. Gradient-echo sequences should prove to be highly useful in detecting and delineating hemorrhages and are recommended for the MR protocol of patients with acute neurologic ictus and suspected hemorrhage.

Acute Disease↗

Detection of acute intracerebral hemorrhage on MR imaging: ineffectiveness of prolonged interecho interval pulse sequences.

MR imaging at 0.6 T was performed in 22 patients with acute (less than 7 days) intracranial hemorrhage to determine the efficacy of prolongation of the interecho interval, which has been demonstrated to enhance T2 shortening in vitro, as a method to improve the detection of hemorrhage in clinical imaging. The protocol included 750/33 (TR/TE), 2150/60,120 (short interecho interval of 60 msec), and 2150/120 (long interecho interval of 120 msec) sequences. Visual comparisons of the 2150/120 images obtained with the short and long interecho intervals demonstrated no difference in the degree of hypointensity in 21 of 22 cases. Quantitative comparisons demonstrated no statistically significant difference in the degree of maximal hypointensity, in the ease of detectability of hypointensity, or in the overall image contrast in 16 of 22 cases. We conclude that prolongation of the interecho interval is not a clinically useful technique to improve the detection of acute hemorrhage.

Acute Disease↗

Differentiation between meningeal fibrosis and chronic subdural hematoma after ventricular shunting: value of enhanced CT and MR scans.

Unenhanced CT in four patients with long-standing ventricular shunts demonstrated bilateral low-density extraaxial collections that were indistinguishable from chronic subdural hematomas. After administration of contrast material, however, there was marked enhancement of the collections as well as prominent paratentorial and parafalcial enhancement. MR imaging, performed in three patients, demonstrated the extent and paradural location of the collections better than CT did, but, as with unenhanced CT, the collections could not be distinguished from chronic subdural hematomas. On follow-up CT and MR, there was no change in the size, enhancement, or intensity of the collections. Histologic examination of biopsies from two patients demonstrated fibrosis of the meninges characterized by granulation tissue and collagen deposition. Meningeal fibrosis is a rare postshunt phenomenon that may mimic chronic subdural hematoma on unenhanced CT and MR. Recognition of this entity is important, particularly if therapeutic intervention is being considered. Therefore, an enhanced CT or enhanced MR scan should be obtained in chronically shunted patients to differentiate between a drainable chronic subdural hematoma and meningeal fibrosis.

Adult↗

Large Virchow-Robin spaces: MR-clinical correlation.

High-field MR scans frequently show Virchow-Robin spaces, which conform to the path of the penetrating arteries as they enter either the basal ganglia or the cortical gray matter over the high convexities. A retrospective review of 816 MR scans was undertaken to determine the clinical significance and associations (if any) of this finding. The Virchow-Robin spaces were graded, as were the nonspecific white-matter lesions. The presence of atrophy, infarction, hydrocephalus, and miscellaneous disease was noted. Large Virchow-Robin spaces were identified in 314 cases. A study sample was created consisting of a positive group containing all the larger grade 2 and 3 Virchow-Robin spaces (67 patients) and a negative or control group of 109 randomly selected patients from the original 502 who did not have large Virchow-Robin spaces. The charts of this study sample were reviewed and the following patient variables were noted: age, gender, incidental white-matter lesions, infarction, dementia, hypertension, and atrophy. For each variable, the proportion of patients who were positive for that variable was calculated for each of the two groups and compared across groups by using a Fisher exact test. Multiple logistic regression analysis was used to determine whether any of these variables were jointly associated with being "positive" or "negative" for large Virchow-Robin spaces. Some variables were strongly associated with being positive for large Virchow-Robin spaces: age, hypertension, dementia, and incidental white-matter lesions. Logistic regression analysis revealed that when all of these variables are considered jointly, only age remains significant.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

MR recognition of supratentorial tumors.

Eighty patients with intrinsic tumors of the cerebral hemispheres and thalami were studied with a 0.5 T superconducting system and third- or fourth-generation computed tomographic (CT) scanners. Twenty-eight patients had histologically verified gliomas, 34 were presumed to have primary brain tumors on clinical grounds, 13 had metastases, and five were postoperative. Lesions shown on CT were equally well demonstrated on magnetic resonance (MR) imaging; more metastases were seen on MR than on CT images. MR revealed abnormal signals in 10 cases in which CT findings were equivocal. It was not possible to differentiate edema from tumor in many cases using the MR imaging sequences currently available. The histologic types of the tumors could not be determined from the MR appearances.

Brain Neoplasms↗

MRI of optic chiasm and optic pathways.

Eight verified lesions of the optic chiasm were examined on 0.5 T magnetic resonance (MR) and GE 9800, 8800 computed tomographic (CT) scanners. Enlargement of the optic chiasm was demonstrated in all cases. There was some change of MR signal compared with brain in all but one case, which had no resemblance to contrast enhancement on CT scans. The signal was specific for hematoma in one case. Abnormal signal, probably signifying tumor spread into the optic radiation, was detected on T2-weighted images in one case. The resolution of MR scans is similar or superior to CT, and sagittal views are most useful in evaluating lesions in this location.

Adolescent↗

Dural sinus thrombosis: verification with spin-echo techniques.

Although MR imaging is being used increasingly to detect dural sinus thrombosis, accurate evaluation of images has often been hindered by the presence of artifacts, especially flow-related enhancement, that may simulate intraluminal clot. We tried an approach with spin-echo techniques to eliminate flow-induced artifacts and, thus, facilitate the diagnosis of dural sinus thrombosis. In this investigation, a nonselective single-section spin-echo verification method was used as a prototype of this approach. Both patients and an experimental flow phantom were used to test the validity of this concept. Clinically, thrombosis was seen to persist as isointense or highly intense signal in the vascular lumina with the specialized sequence, while flow-related artifacts were replaced by hypointense signal, but not by signal void. These same changes were examined both quantitatively and qualitatively in the flow phantom by using varying velocities of flow. Although our clinical investigation concerns suspected dural sinus thrombosis, the principles of these specialized spin-echo techniques can be applied successfully throughout the head to eliminate certain flow-related artifacts.

Adolescent↗

Head trauma: comparison of MR and CT--experience in 100 patients.

The results of CT and MR imaging were reviewed retrospectively and compared in 100 patients who experienced clinically significant head trauma. The findings were analyzed on the basis of several parameters in an attempt to establish objective clinical guidelines for the use of each diagnostic technique. CT remains the screening method of choice in evaluating acute severe head trauma; however, MR revealed additional clinically relevant findings in all four cases in which the patient's clinical symptoms were disproportionate to the CT findings. MR was equal or superior to CT in the evaluation of all patients with acute minor head trauma and in 94 of 95 patients examined in the subacute, chronic, or remote phase of injury, irrespective of the severity or pathologic nature of their injuries. All subacute contusions (21 lesions) and white-matter shearing lesions (18 cases) were demonstrated to particular advantage on MR compared with CT, as were all subdural hematomas (of 52 small subdural collections, 58% were detected only by MR). Although surgical management was not altered by the additional information provided by MR, the implications regarding the medical management and disposition of the patients with head trauma were significant.

Brain Concussion↗

Magnetic resonance imaging of meningiomas.

Twenty-eight patients with 32 meningiomas were studied on a 0.5-T superconductive magnetic resonance (MR) imager. This common, benign treatable tumor was more clearly seen on computed tomography (CT) than MRI in 53% of cases. This is a result of poor contrast between the tumor and the adjacent brain on all spin-echo and inversion-recovery pulse sequences. Those sequences that provide the greatest anatomic detail were best for identifying this low-contrast lesion. Inversion-recovery scans in particular demonstrated the tumor as a discrete hypointense mass (relative to nearby white matter) with excellent visualization of the dural base and white matter buckling indicative of extracerebral mass effect. Other characteristic features include: a hypointense rim because of the venous capsule (66%); mottling due to hypervascularity; a well defined edema collar that demarcates the tumor from adjacent brain; and hyperostosis with thickening of the calvaria and obliteration of its normal landmarks. MRI did not demonstrate tumor calcification but did demonstrate vascular encasement, displacement, and occlusion better than CT and as well as digital venous angiography.

Adult↗

MR imaging of brainstem tumors.

Eighteen patients aged 4-72 years old with brainstem tumors were studied using a 0.5 T magnetic resonance (MR) imager and a third- or fourth-generation computed tomographic (CT) scanner. MR imaging showed the brainstem to be enlarged on sagittal views in all cases; exophytic growth was seen in eight. Alterations of signal intensities were shown in most cases on spin-echo sequences using 30 and 90 msec echo times and inversion recovery techniques. It was not possible to distinguish primary from metastatic tumors. The configurations and margins of the areas with abnormal signal did not appear to correlate with the clinical behavior of the tumors. CT was able to recognize brainstem tumor in only 13 of 16 cases. In the two cases of metastases, plain CT scans were normal, but enhancement was seen after administration of contrast material in one. It appears that MR imaging is sensitive in detecting tumor enlargement and abnormal signals and is superior to CT in evaluating brainstem tumors.

Adolescent↗

MR imaging of the craniocervical junction.

Craniocervical junctions in 35 abnormal and 10 normal subjects were studied with a 0.5 T superconducting magnetic resonance imaging system. Sagittal spin echo with 30 msec echo times and 500 msec repetition times constituted the most informative imaging plane and sequence. The anterior aspect of the foramen magnum was well delineated; the posterior margin was less constant in appearance. Compression and distortion of the medulla and upper cervical cord by bony and extramedullary lesions were seen easily. Intramedullary cysts were differentiated from solid tumors, but ventricular communication was evaluated less successfully because of partial-volume effect of the sections. Cerebellar ectopias were detected in some asymptomatic patients.

Arachnoid↗

MR imaging of cerebral vascular malformations.

Fifteen vascular malformations, including six supratentorial arteriovenous malformations (AVMs), three venous malformations, and six brainstem vascular malformations, were examined on 0.5 T magnetic resonance (MR) and GE 9800 and 8800 computed tomographic (CT) scanners. All the malformations were shown by MR, and the arterial and venous drainage of AVMs was precisely delineated. Hematoma was always differentiated from calcification by MR signal characteristics. Increased signal in the brain parenchyma was often seen adjacent to AVMs. The signal of blood within venous malformations altered with spin-echo techniques using various repetition times and was distinguished from rapidly flowing blood in AVMs that lacked signal in all imaging sequences. Brainstem malformations were seldom demonstrated by angiography. Hemorrhage was common and was invariably associated with multiple areas of absent signal that may have represented abnormal vessels. These appearances are distinct from those of intrinsic tumors and are probably pathognomonic of brainstem vascular malformations.

Brain↗

Optimization of xenon-enhanced CT studies: beam energy, enhancement, root mean square deviation, and repeatability.

The effects of varying beam energy on the computed tomographic (CT) enhancement-to-noise (S:N) ratio were studied experimentally with the DeltaScan 2020 and GE 8800 CT scanners and a 20-cm-diameter cyclindrical Plexiglas phantom containing 11 50 ml syringes filled with varying amounts of xenon and iodine. Enhancements of 54.2, 36.7, and 31.7 Hounsfield units (H)/mg l/ml were measured with the DeltaScan 2020 at 70, 100, and 120 kVp, respectively, with corresponding root mean square deviations (RMSDs) of 12, 7, and 5 H for 400 mAs scans. For the GE 8800, enhancements of 48.3, 37.6, and 32.7 H/mg l/ml were measured at 80, 100, and 120 kVp with RMSDs of 13, 8, and 7 H for 9.6 sec 320 mA scans (3.3 msec pulse). RMSD was independent of enhancement over the range of iodine concentrations studied (0-1.5 mg l/ml) and was only a weak function of region-of-interest (ROI) size. For repeated scans with the DeltaScan 2020, measurements in 17 X 17 pixel regions were reproducible to within 0.8 H for all techniques and a drift in calibration of less than 6% was observed after 8 months of clinical use. For both the DeltaScan 2020 and the GE 8800, at the milliamperage studied, lower-energy techniques offered no advantage over 120 kVp technique for xenon CT measurements of regional cerebral blood flow, which are feasible using either of these scanners.

Radiographic Image Enhancement↗