Evaluation of chemiluminescence immunoassays for detecting thyroglobulin (Tg) and thyroid peroxidase (TPO) autoantibodies using the IMMULITE 2000 system.

The chemiluminescence assays for detection of autoantibodies to thyroid peroxidase (TPO) and thyroglobulin (Tg) implemented on the IMMULITE 2000 system (Diagnostic Products Corporation) were evaluated. These were immunometric assays with antigen-coated beads and monoclonal murine anti-IgG antibodies conjugated with alkaline phosphatase. Precision was satisfactory with an intraassay precision of 5.3-5.5% for anti-Tg and 4.8-5.3% for anti-TPO and an interassay precision of 5.7-7.3% for anti-TPO and 5.2-7.5% for anti-Tg. The lower detection limit was determined as 5 IU/ml for anti-TPO and 2.2 IU/ml for anti-Tg. The average dilution linearities of 102% for anti-TPO and 100% for anti-Tg and the average recovery of 80-127% for anti-TPO and 93-112% for anti-Tg were acceptable. The findings of the tests were compared with the systems from Pharmacia & Upjohn, ORGenTec, Roche Diagnostics, Byk Sangtec Diagnostica and BRAHMS Diagnostica. Taking the respective cutoff value into account, concordance was 87-96% for anti-Tg and 87-97% for anti-TPO. Summarizing all results from the different methods revealed a clinical agreement of 95% for anti-TPO and 93% for anti-Tg. A good agreement was found with the IMMULITE anti-TPO and anti-Tg assays, which are closely related as regards method and biochemistry. Regression analysis gave the following results: anti-TPO IMMULITE 2000 vs anti-TPO IMMULITE: anti-TPO IMMULITE 2000 = 0.99 x IMMULITE anti-TPO - 1.43 IU/ml (r = 0.99, n = 144). anti-Tg IMMULITE 2000 vs anti-Tg IMMULITE: anti-Tg IMMULITE 2000 = 0.98 x IMMULITE anti-Tg + 1.63 IU/ml (r = 0.99, n = 86). Further age-dependent normal ranges were evaluated. A higher prevalence of elevated autoantibody titers was found for patients older than 50 years. The rate of elevated antibody titer can be reduced by using an age-dependent reference range: < or = 50 years anti-TPO < 35 IU/ml, anti-Tg < 40 IU/ml and > 50 years anti-TPO < 100 IU/ml, anti-Tg < 80 IU/ml. Further samples from clinically diagnosed Hashimoto's thyroiditis and Graves' disease were investigated. The levels of positive anti-Tg values and anti-TPO values accorded with those stated in the literature and were comparable to those measured with a reference assay. In the tested INSTAND e. V. interlaboratory samples there was high-level accordance with the expected clinical results.

Antibodies, Monoclonal↗

FDG PET detection of unknown primary tumors.

UNLABELLED: The management of patients presenting with metastases of unknown primary origin remains a clinical challenge despite a large variety of imaging modalities. The aim of this study was to evaluate FDG PET in detecting the sites of primary cancer in these patients. METHODS: Fifty-three patients with metastatic cervical adenopathy (n = 44) or extracervical metastases (n = 9) of unknown primary origin were included after extensive but inconclusive conventional diagnostic work-up. Patients received 370 MBq FDG (10 mCi) intravenously, and whole-body images were acquired at 60 min after injection. Clinical, surgical, and histopathologic findings and complete correlative imaging were used to assess the results. RESULTS: In 27 of 53 patients FDG PET showed focal tracer accumulations corresponding to potential primary tumor sites located in the lungs (n = 12), the palatine tonsil (n = 5), the salivary glands (n = 2), the nasopharynx (n = 1), the oropharynx (n = 3), the maxillary sinus (n = 1), and the larynx (n = 1). Moreover, in 2 patients FDG PET revealed lesions suspected to be tumors in the breast and the ileocolonic area. In 20 (37.8%) of these 53 patients FDG PET was true-positive, identifying the primary tumor in the lungs (n = 10), the head and neck region (n = 8), the breast (n = 1), and the ileocolonic area (n = 1). In 6 of 27 patients FDG PET was false-positive, predominantly identifying suspicious areas in the palatine tonsil (n = 3). One patient denied further diagnostic work-up after PET; thus, positive PET could not be evaluated. In 26 of 53 patients PET did not reveal lesions suspected to be the primary. However, primary tumors were not found in these patients at clinical follow-up. CONCLUSION: FDG PET is a valuable diagnostic tool in patients with cancer of unknown primary because it imaged unknown primary tumors in about one third of all patients investigated. In addition, FDG PET assists in both guiding biopsies for histologic evaluation and selecting the appropriate treatment protocols for these patients.

Adult↗

Standardized annotation of nuclear medicine images.

There are no generally accepted standards for annotating nuclear medicine images. This is a potential problem whenever hardcopies from other centers are being evaluated, reinterpreted or compared to actual images of the same patient. Proposals for image annotation are elaborated to support image evaluation by a third party. In this paper, examples are given of lung scintigraphy, thyroid scintigraphy, bone scintigraphy both in planar and SPECT techniques, renal function scintigraphy, myocardial perfusion scintigraphy, and PET. They are presented to stimulate discussion in the nuclear medicine community.

Forms and Records Control↗

Age- and sex-related bone uptake of Tc-99m-HDP measured by whole-body bone scanning.

UNLABELLED: AIM of this study was to validate a recently introduced new and easy-to-perform method for quantifying bone uptake of Tc-99m-labelled diphosphonate in a routine clinical setting and to establish a normal data base for bone uptake depending on age and gender. METHODS: In 49 women (14-79 years) and 47 men (6-89 years) with normal bone scans as well as in 49 women (33-81 years) and 37 men (27-88 years) with metastatic bone disease whole-body bone scans were acquired at 3 min and 3-4 hours p.i. to calculate bone uptake after correction for both urinary excretion and soft tissue retention. RESULTS: Bone uptake values of various age-related subgroups showed no significant differences between men and women (p > 0.05). Furthermore, no differences could be proven between age-matched subgroups of normals and patients with less than 10 metastatic bone lesions, while patients with wide-spread bone metastases revealed significantly increased uptake values. In both men and women highest bone uptake was obtained (p < 0.05) in subjects younger than 20 years with active epiphyseal growth plates. In men, bone uptake slowly decreased with age up to 60 years and then showed a tendency towards increasing uptake values. In women, the mean uptake reached a minimum in the decade 20-29 years and then slowly increased with a positive linear correlation of age and uptake in subjects older than 55 years (r = 0.57). CONCLUSION: Since the results proposed in this study are in good agreement with data from literature, the new method used for quantification could be validated in a large number of patients. Furthermore, age- and sex-related normal bone uptake values of Tc-99m-HDP covering a wide range of age could be presented for this method as a basis for further studies on bone uptake.

Adolescent↗

Low-cost, small-animal shelf for simultaneously assessing several small animals with a whole-body PET scanner.

OBJECTIVE: The purpose of this work was to establish a low-cost device for simple positioning of several small animals within a whole-body PET scanner. METHODS: The device was designed as a stackable shelf for 3 x 3 animals, similar to a stackable shelf for wine bottles. It was constructed from ordinary PVC drain pipe and acrylic panes. RESULTS: The shelf simplified accurate and reproducible positioning of the animals and, therefore, supported automatic data processing. Deterioration of image quality by attenuation of photons within the shelf itself was rather small. CONCLUSION: The small-animal shelf is a useful, low-cost device for simultaneously assessing up to 9 small animals with a whole-body PET scanner.

Acrylic Resins↗

A survey of guidelines in 27 EANM associated societies by the EANM Task Group on Quality Assurance and Standardisation. European Association of Nuclear Medicine.

The main aim of the EANM Task Group on Quality Assurance and Standardisation is to develop harmonised clinical procedures that are accepted within Europe. In order to achieve an evidence-based analysis of guidelines in the 27 EANM member societies, a survey was conducted. A questionnaire in mid 1999 investigated three major questions: (1) current status of national guidelines in EANM member societies, (2) specification of the cover and level of these national guidelines, and (3) future desires for national, EANM and SNM guidelines. The complete response rate was 96% (26/27). Guidelines are required by 19 of 27 member societies and have been initiated by 16 member societies. Guidelines are provided by 13 member societies, generally in the national language. In ten societies, specialists other than nuclear medicine physicians, mostly physicists and radiopharmacists, take the lead on some guidelines. Moreover, in some national societies there is active collaboration with other medical societies when writing guidelines, particularly cardiology societies. Currently, only 18% of the necessary procedure guidelines are covered. Compared with a survey conducted in 1993 by the EANM Committee on Quality Assurance and Standardisation, slow progress has been made in this regard, but compared with a survey conducted by the same committee in 1996 in 23 EANM member societies, the number of member societies providing guidelines has approximately doubled. Moreover, 26 of 27 member societies share a commitment for future development of guidelines and 21 of 27 prefer EANM guidelines to national guidelines. The results of this questionnaire justify the need for close co-operation between EANM, EANM member societies, the EANM Task Group on "Quality Assurance and Standardisation" and the Guideline Committee of the SNM. The clinical priorities are considered to be cardiac, renal and brain procedures.

Data Collection↗

Radioprotection of salivary glands by S-2-(3-aminopropylamino)-ethylphosphorothioic (amifostine) obtained in a rabbit animal model.

BACKGROUND: Impairment of salivary gland function following high-dose radioiodine treatment (HDRIT) is a well-recognized side effect of the treatment. Because differentiated thyroid cancer has an excellent prognosis, reduction of long-term side-effects is mandatory. Therefore, the aim of this study was to investigate the radioprotective effect of amifostine in a rabbit animal model. METHODS: Salivary gland scintigraphy was performed in a total of 16 New Zealand White rabbits. Uptake of 99-Tc-pertechnetate was calculated in percentage of injected activity as a quantitative measure of both salivary gland and thyroid function. Reproducibility of salivary gland scintigraphy was evaluated in one rabbit without any intervention. Fifteen rabbits were studied prior to and up to 6 months after high-dose radioiodine treatment applying 2 GBq 131I. Ten animals received 200 mg/kg amifostine prior to high-dose radioiodine therapy, and 5 served as controls. Salivary glands were examined histopathologically. RESULTS: Variation coefficient of parenchymal function was less than 3.8% in salivary glands. Prior to HDRIT, thyroid uptake was 0.417+/-0.373% and 0.421+/-0.241% in control and amifostine-treated rabbits, respectively. Four weeks after HDRIT, complete ablation of the thyroid was achieved in both groups. Prior to HDRIT, uptake of 99mTc-pertechnetate in salivary glands of five control rabbits was not significantly different from ten amifostine-treated rabbits. In control rabbits 6 months after HDRIT, parenchymal function was reduced significantly (p < 0.0001) by 75.3+/-5.3% and 53.6+/-17.4% in parotid and submandibular glands, respectively. In contrast, in amifostine-treated rabbits, parenchymal function was reduced by 10.6+/-3.4% and 6.5+/-4.3% (p > 0.05) in parotid and submandibular glands, respectively. Histopathologically, marked lipomatosis was observed in control animals but was negligible in amifostine-treated animals. CONCLUSION: Parenchymal damage in salivary glands induced by high-dose radioiodine treatment can be significantly reduced by amifostine in this rabbit animal model. This corresponds to data obtained in patients with differentiated thyroid cancer.

Amifostine↗

Salivary gland protection by amifostine in high-dose radioiodine therapy of differentiated thyroid cancer.

BACKGROUND: Salivary gland impairment following high-dose radioiodine treatment is a well-recognized side effect, in general caused by free radicals. Therefore, it seemed promising to evaluate the radioprotective effect of the radical scavenger amifostine in patients receiving high-dose radioiodine therapy. PATIENTS AND METHOD: Quantitative salivary gland scintigraphy using 100 to 120 MBq Tc-99m-pertechnetate was performed in 17 patients with differentiated thyroid cancer prior to and 3 months after radioiodine treatment with 6 GBq I-131. Eight patients were treated with 500 mg/m2 amifostine prior to high-dose radioiodine treatment and compared retrospectively with 9 control patients. Xerostomia was graded according to WHO criteria. RESULTS: In 9 control patients high-dose radioiodine treatment significantly (p < 0.01) reduced Tc-99m-pertechnetate uptake by 35.4 +/- 22.0% and 31.7 +/- 21.1% in parotid and submandibular glands, respectively. Of these 9 patients, 3 exhibited xerostomia Grade I (WHO). In contrast, in 8 amifostine-treated patients, there was no significant (p = 0.878) decrease in parenchymal function following high-dose radioiodine treatment, and xerostomia did not occur in any of them. CONCLUSION: Parenchymal damage in salivary glands induced by high-dose radioiodine treatment can be reduced significantly by amifostine. This may help to increase patients' quality of life in differentiated thyroid cancer.

Adult↗

[F-18 FDG PET for detection of occult primary tumor in patients with lymphatic metastases of the neck region].

BACKGROUND: The occult primary tumor remains an important diagnostic problem in patients with lymph node metastases despite a large variety of imaging modalities. Therefore, the aim of our study was to evaluate the impact of F-18-FDG-positron-emission-tomography (PET) in these patients. METHODS: The study group included a total of 28 patients aged 39 to 84 years with cervical lymph node metastases of a histologically confirmed squamous cell carcinoma (n = 24) or an undifferentiated carcinoma (n = 4). All patients received 370 MBq F-18-FDG intravenously, and whole-body images were acquired at 60 min p.i. with an ECAT EXACT 47 (921) (Siemens, CTI). All lesions were evaluated either by histology or by CT/MRI. RESULTS: In 12 patients PET did not reveal suspected tumorous lesions. In contrast in 16/28 patients PET showed focal tracer accumulations corresponding to potential primary tumor sites located in the lungs (n = 7), in the region of the tonsilla palatina (n = 5), in the submandibular gland (n = 1), in the nasopharynx (n = 1), in the larynx (n = 1), or at the base of the tongue (n = 1). In nine out of these 16 patients, the primary was confirmed in the lungs in 5 patients, in the larynx, at the base of the tongue, in the nasopharynx, and the tonsilla palatina in one patient each, respectively. Moreover, in 6 out of 16 patients, PET was false-positive. One patient refused further evaluation of PET findings. CONCLUSIONS: In approximately one third of all patients, PET detected the primary tumor site, which significantly influenced further therapeutic procedures. Thus, F-18-FDG-PET may be a valuable diagnostic tool in the detection of the primary tumor in patients with cervical lymph node metastases.

Adult↗

Salivary gland protection by S-2-(3-aminopropylamino)-ethylphosphorothioic acid (amifostine) in high-dose radioiodine treatment: results obtained in a rabbit animal model and in a double-blind multi-arm trial.

Since differentiated thyroid cancer has an excellent prognosis, reduction of long-term side effects of high-dose radioiodine treatment (HD-RIT), i.e. salivary gland impairment is important. Thus, radioprotective effects of amifostine were studied. Salivary gland function was quantified by scintigraphy both in rabbits and patients. Fifteen rabbits were studied prior to and up to 6 months after HD-RIT applying 2 GBq 131I. Ten animals received 200 mg/kg amifostine prior to HD-RIT, and five served as controls. Animals were examined histopathologically. Fifty patients with differentiated thyroid cancer were evaluated prospectively prior to and 3 months after HD-RIT with either 3 or 6 GBq 131I in a double-blind, placebo-controlled study. Twenty-five patients were treated with 500 mg/m2 amifostine intravenously prior to HD-RIT, and 25 patients receiving physiological saline solution served as controls. Complete ablation of the thyroid was achieved in all rabbits four weeks after HD-RIT. In control rabbits 6 months after HD-RIT parenchymal function was reduced significantly (p < 0.0001) by 75.3 +/- 5.3% and 53.6 +/- 17.4% in parotid and submandibular glands, respectively. In contrast, in amifostine-treated rabbits parenchymal function was not significantly reduced. Histopathologically, marked lipomatosis was observed in control animals but was negligible in amifostine-treated animals. In control patients, salivary gland function was significantly (p < 0.001) reduced by 40.2 +/- 14.1% and 39.9 +/- 15.3% in parotid and submandibular glands, respectively, three months after HD-RIT, and 11 patients developed xerostomia. In 25 amifostine-treated patients, salivary gland function was not significantly reduced (p = 0.691), and xerostomia did not occur. Thus, parenchymal damage in salivary glands induced by high-dose radioiodine therapy can be reduced significantly by amifostine. This may improve quality of life of patients with differentiated thyroid cancer.

Adult↗

[Onco-PET: lesion detection by monitor versus standardized film documentation].

AIM: Lesion detection and localization of 2-[18F]fluoro-2-deoxy-D-glucose (F-18-FDG) Onco-PET-Investigations are usually performed on-line at the computer display. The aim of the present study was to evaluate the clinical efficacy of a standardized film documentation as an alternative approach. METHODS: 100 Onco-PET-investigations without attenuation correction were analyzed with regard to number and localization of lesions suspicious of malignancy. A standardized documentation on film was developed including 1. transversal slices of the brain, 2. coronal slices and maximum-intensity-projections (MIPs) of the head/neck region and 3. of the trunk and 4. MIPs of the legs. These transparencies were analyzed at the light box. An additional analysis on the computer display was performed slice by slice in coronal, transversal and sagittal directions for the whole body. RESULTS: A total of 315 lesions were detected in 100 patients. In 96/100 patients the two modalities agreed both in number and localization of tumor-suspicious lesions. 7 lesions in the legs of 3 patients didn't show when interpreting the films (MIPs only). In 2/100 patients additional analysis on the computer display caused a change in the localization of 9/315 lesions. 8 of these were located in the legs. When adding coronal slices for the documentation of the lower extremities all the lesions were shown. Moreover, all lesions were localized correctly except one clinically non-relevant change of localization out of a total of 322 lesions. CONCLUSION: The newly developed standardized documentation supports the concept of film reading and reporting of onco-PET investigations, restricting an additional on-line analysis to rare cases only. Furthermore, the intention of the "Arbeitsgemeinschaft Standardisierung" (work group standardisation) are met, i.e. to ease analysis of follow-up studies acquired at different places.

Documentation↗

Lymphoscintigraphy in tumors of the head and neck using double tracer technique.

UNLABELLED: Knowledge of possible lymphatic drainage may facilitate planning of surgery for patients with head and neck tumors. Therefore, the aim of this study was to present a method of lymphoscintigraphy with special attention to an accurate correlation of lymphatic drainage to anatomic regions. METHODS: Lymphoscintigraphy was performed using a double tracer technique before surgery in a total of 75 patients with squamous cell carcinoma of the head and neck. All patients received 100 MBq 99mTc-colloid at three to four peritumoral sites. A perchlorate solution (2 mL) was given orally to block salivary glands and the thyroid gland. Patients received 50 MBq 99mTc-pertechnetate intravenously for body contouring 20 min postinjection. Planar images were obtained over 5 min each, at 30 min and 4 h postinjection from anterior, right lateral and left lateral views with a large-field-of-view gamma camera. Lymphatic drainage was assessed by visual inspection and assigned to six cervical compartments. RESULTS: Neither the salivary glands nor the thyroid gland were seen in any of the patients. In 22 of 75 patients (29.3%), the injection site was the only focal tracer uptake seen. In contrast, lymphatic drainage was identified in the remaining 53 patients (70.7%), and lymph nodes could be assigned easily to the six cervical compartments. Of 75 patients, 36 (48%) exhibited ipsilateral lymphatic drainage. In addition, 17 patients (22.7%) with unilateral tumor showed bilateral (n = 12), contralateral (n = 2) or retropharyngeal (n = 3) lymphatic drainage. In 3 of these 17 patients, bilateral lymph node metastases were proven. A subgroup of 12 patients (16%) exhibited N2c nodal status, despite a unilateral localized primary tumor. In 3 of these 12 patients, surgery was extended as a result of scintigraphic findings from unilateral toward bilateral neck dissection, and histology confirmed nodal involvement in these patients. CONCLUSION: Lymphoscintigraphy using the double tracer technique allows an accurate correlation of lymphatic drainage to the six cervical compartments. This may provide the basis for a re-evaluation of its impact in treatment planning of patients with head and neck tumors.

Adult↗

Quantitative salivary gland scintigraphy.

OBJECTIVE: Uptake of 99mTc-pertechnetate in salivary glands reflects intact salivary gland parenchyma. However, no standardized protocol for an accurate quantification of parenchymal function has been established so far. METHODS: In this paper we report on a validated acquisition protocol supplying a normal database for standardized quantitative salivary gland scintigraphy. RESULTS: The major advantage of salivary gland scintigraphy, as compared to other imaging modalities, is that both parenchymal function and excretion fraction of all four major salivary glands (i.e., parotid and submandibular glands) can be simultaneously quantified with a single intravenous injection. CONCLUSION: Quantitative salivary gland scintigraphy is demonstrated to be a suitable imaging modality for research applications in evaluating the effects of radioprotective drugs on salivary glands. Salivary gland scintigraphy is easy to perform, reproducible and well-tolerated by the patient.

Adolescent↗

Clinical value of 24-hour delayed imaging in somatostatin receptor scintigraphy for meningioma.

UNLABELLED: Somatostatin receptor scintigraphy (SRS) using 111In-octreotide has proven useful in patients suspected of having meningiomas. Delayed imaging is regularly performed up to 24 h postinjection. However, this procedure is time consuming and expensive. Therefore, we investigated whether 24-h imaging may be omitted in these patients. METHODS: After clinical examination and standard MRI, 71 patients were suspected of having 92 meningioma lesions. Before surgery, all patients underwent SRS after intravenous injection of 200 MBq (5.4 mCi) 111In-octreotide. Planar whole-body images were obtained at 10 min and 1, 4 and 24 h, and SPECT was performed at 4 and 24 h. Results of SRS in all lesions were evaluated with respect to histology and time of image acquisition. RESULTS: SRS yielded 58 true-positive, 20 true-negative and 14 false-negative results, with the false-negatives all less than 5 mL (2.3+/-2.1 mL) in volume. In 52 of 58 true-positive lesions (89.7%), diagnosis could be established by 4-h imaging without further information by 24-h imaging. In 10 of the 52 lesions, SPECT was necessary to confirm planar findings. Imaging at 24 h was necessary in only 6 of 58 true-positive lesions (10.3%): 3 patients who had intracranial relapse of meningioma (volume < 5 mL) and 3 who had spinal meningioma. Thus, a diagnosis of intracranial meningioma could be established in 52 of 55 lesions (95%) using a 4-h imaging protocol. CONCLUSION: With a 4-h acquisition protocol that includes SPECT imaging, SRS yields sufficient information in patients suspected of having intracranial meningiomas. Delayed imaging at 24 h is recommended only for patients who have small meningiomas (volume < 5 mL), spinal localizations or negative SRS at 4 h.

Adolescent↗

Pregnancy testing before high-dose radioiodine treatment: a case report.

This case emphasizes that negative urine pregnancy testing and a written declaration of the patient are not sufficient to safely exclude an early pregnancy. Serum pregnancy testing inherently has a diagnostic gap of about 1 wk following conception. We recommend sufficient contraception at least 1 mo before radioiodine treatment in women of childbearing age.

Adult↗

Quality assurance in PET: evaluation of the clinical relevance of detector defects.

UNLABELLED: Defective detector blocks in PET may cause serious image artifacts. To estimate the influence of malfunctioning detectors on image quality, a method is described for transferring the actual detector defect onto previously acquired scans. METHODS: Consequences of detector defects of varying types and extensions were simulated in phantom studies as well as in clinical 18F-fluorodeoxyglucose investigations. First, a condition frame was obtained by dividing the sinogram of a blank measurement, obtained with rod sources on the defective PET camera, by the sinogram of a reference blank acquired before the appearance of the defect. Second, the sinogram of a previously acquired typical patient study was multiplied by the condition frame and reconstructed. Thereafter, images from corrupted sinograms were compared visually with their originals. For repairing defective sinograms, linear interpolation and the constrained Fourier space method were tested. RESULTS: The effects of detector defects can be simulated accurately in patient studies. The correction methods applied are especially helpful in cases of (a) several neighboring defective detectors and small study objects, (b) small hot artifacts and (c) several nonadjacent defective detectors. Linear interpolation is faster than the constrained Fourier space method; it is more widely applicable and provides similar results. CONCLUSION: The proposed approach allows specific evaluation of clinical consequences of detector defects. This technique simplifies the decision as to whether a planned patient study can be performed or must be postponed. Even in cases of serious detector problems, sinogram repair may help eliminate image artifacts and minimize the loss of image quality.

Artifacts↗

Radioprotection of salivary glands by amifostine in high-dose radioiodine treatment. Results of a double-blinded, placebo-controlled study in patients with differentiated thyroid cancer.

BACKGROUND AND PURPOSE: Parenchymal impairment of salivary glands following high-dose radioiodine treatment is a well-known side effect in general caused by free radicals. Therefore, the radioprotective effect of the radical scavenger amifostine was evaluated prospectively in patients receiving high-dose radioiodine treatment. PATIENTS AND METHODS: Parenchymal function was assessed by quantitative salivary gland scintigraphy performed in 50 patients with differentiated thyroid cancer prior to and 3 months after high-dose radioiodine treatment with either 3 GBq 131I (n = 21) or 6 GBq 131I (n = 29) in a double-blinded, placebo-controlled study. Twenty-five patients treated with 500 mg/m2 amifostine intravenously prior to high-dose radioiodine treatment were compared to 25 control patients receiving physiological saline solution. Xerostomia was graded according to WHO-criteria. RESULTS: In 25 control patients high-dose radioiodine treatment significantly (p < 0.001) reduced parenchymal function of parotid and submandibular glands by 40.2 +/- 14.1% and 39.9 +/- 15.3%, respectively. Nine out of these 25 patients developed Grade I and 2 Grade II xerostomia. In contrast, in 25 amifostine-treated patients there was no significant (p = 0.691) decrease in parenchymal function following high-dose radioiodine treatment, and xerostomia did not occur in any of them. CONCLUSION: Parenchymal damage of salivary glands induced by high-dose radioiodine treatment can be significantly reduced by amifostine which may improve quality of life of patients with differentiated thyroid cancer.

Adenocarcinoma, Follicular↗

[Efficacy of radiation synovectomy in degenerative inflammatory and chronic inflammatory joint diseases].

AIM: Effect of radiosynovectomy (RS) should be evaluated both by subjective and objective parameters in patients with osteoarthritis and in patients with inflammatory joint disorders not caused by rheumatoid arthritis. METHODS: A total of 98 joints in 61 patients were investigated. Patients were divided into two groups. The first group included 35 patients with therapy-resistant effusions caused by severe osteoarthritis (46 joints). The second group consisted of 26 patients (52 joints) with ankylosing spondylitis, reactive arthritis, undifferentiated spondylarthropathy, psoriatic arthritis, pigmented villo-nodular synovitis, and recurrent synovitis following surgery. Effect of RS was evaluated by a standardized questionnaire and quantified by T/B-ratios derived from blood pool images prior to and after RS. RESULTS: Within the first patient group suffering from osteoarthritis, 40% showed a good or excellent improvement of clinical symptoms, 51% were unchanged, and in 9% symptoms worsened. Similar results were found in the second patient group. The majority of unchanged results were small finger joints. In contrast, wrist and knee joints showed a better improvement. Good correlation between results of bone scan and patients subjective impression was found in 38% and 67% in the first and the second patient group, respectively. CONCLUSION: Radiosynovectomy might be an effective treatment in osteoarthritis and inflammatory joint disorders not caused by rheumatoid arthritis.

Adult↗