Search PubMedSearch

Biomedical subjects

M C Stuart

Publications and source records attributed to M C Stuart.

At least 37 records · Page 2Linked to original sources

Intermediary structures during membrane fusion as observed by cryo-electron microscopy.

Lipidic phases, containing 'lipidic particles' (dioleoylphosphatidylethanolamine/cholesterol/dioleoylphosphatidylcho lin e and cardiolipin/dimyristoylphosphatidylcholine in the presence of Ca2+) have been investigated by preparing thin films from a suspension of sonicated vesicles. These thin films were vitrified and observed 'directly' by cryo-electron microscopy in their hydrated form. The thin films show various fusion products and fusion intermediates such as lipidic particles.

Calcium

Specificity of two-site immunoassays.

When cross-reaction in two-site immunoassays was investigated both theoretically and experimentally it was found that such systems do not always result in enhanced specificity. Computer simulation studies indicated that substances which display negligible cross-reaction in a radioimmunoassay could produce an assay response identical to that of the analyte in a two-site immunoassay using excess antibody. Cross-reactivity in two differing two-site immunoassays was compared to that obtained in radioimmunoassays using the same monoclonal antibodies for human chorionic gonadotrophin. In addition to the effects of excess antibody, cross-reactivity was observed in one of the two-site immunoassays which could not have been predicted from the specificity of the antibodies or cross-reactivity in the radioimmunoassays. The unexpected cross-reaction of the beta subunit of human chorionic gonadotrophin in the assay resulted from an apparent alteration in the specificity of one of the antibodies following binding of the beta subunit to the second antibody. These studies emphasise the complexity of binding reactions in two-site immunoassays.

Antibodies, Monoclonal

Quantification of urinary growth hormone (GH) excretion by centrifugal ultrafiltration and radioimmunoassay: appraisal of the relationship between 24 h urinary GH and mean 24 h serum GH levels in normal and abnormal states of GH secretion.

We have applied a simple method for the quantification of 24 h urinary GH excretion (24 h UGH), combining centrifugal ultrafiltration and radio-immunoassay (RIA), to an appraisal of the relationship between 24 h UGH and mean 24 h serum GH levels in normal and abnormal states of GH secretion. Forty-four subjects, comprising 13 normal adults, 12 short-statured subjects and 19 subjects with active acromegaly, underwent blood sampling at 20-min intervals and concurrent urine collection for 24 h. Mean 24 h serum GH and 24 h UGH were also determined in four post-menopausal women before and during cyclical oestrogen replacement therapy, and 24 h UGH was measured in six normal men prior to and following the subcutaneous administration of biosynthetic GH (0.2 IU/kg). Each subject's mean 24 h serum GH level was determined by assaying a 'pooled' sample, derived from equal aliquots of the 73 serum samples obtained during the 24 h study. The method for quantification of 24 h UGH employs centrifugal microconcentrators, and involves a 50-fold concentration of urine, followed by dialysis and RIA. Surface adsorptive hormone loss during sample collection and ultrafiltration is minimized by the prior addition of bovine serum albumin to the urine collection container. Immunoreactive GH in ultrafiltered urine dilutes in parallel with the RIA standard curve. GH is stable in urine stored at - 20 degrees C for at least 12 months. There was a highly significant correlation between 24 h UGH and mean 24 h serum GH values obtained from the combined population of normal adults (including the post-menopausal women during oestrogen therapy) and short-statured subjects (r = 0.69, P less than 0.0001). A significant correlation was also found in short-statured subjects alone (r = 0.63, P less than 0.05). In contrast, there was no significant correlation between 24 h UGH and mean 24 h serum GH in subjects with active acromegaly, and their 24 h UGH values were not distinguishable from those of the 'non-acromegalic' subjects. A significant increase in 24 h UGH occurred in the post-menopausal women given cyclical oestrogen replacement therapy (9.7 +/- 2.6 (mean +/- SE) to 24.6 +/- 1.0 muIU/mmol creatinine, P less than 0.02), reflecting the increase in their mean 24 h serum GH levels (0.8 +/- 0.3 to 5.3 +/- 0.7 mIU/l, P less than 0.01). Twenty-four hour UGH increased from 4.6 +/- 0.6 to 17.1 +/- 2.1 muIU/mmol creatinine (P less than 0.002) in the men given biosynthetic GH. Twenty-four hour UGH measurements reflect mean 24 h serum GH levels in normal adults and short-statured subjects. While the measurement of 24 h UGH shows promise as an investigative tool, our results cast doubt on its use in the diagnosis of acromegaly.

Acromegaly

The pharmacokinetics, safety and endocrine effects of authentic biosynthetic human growth hormone in normal subjects.

The pharmacokinetics, safety and endocrine effects of an authentic human growth hormone (bio-hGH), produced by the expression of genomic hGH in a mammalian cell line, were studied in six healthy young men who were administered 0.2 U/kg/day subcutaneously for five consecutive days. Changes in sodium balance and in thyroid function were studied during the week of bio-hGH administration and safety parameters were monitored over a 3-week period. Growth hormone levels reached a mean (+/- SD) peak of 106 +/- 10 mIU/l at 3.3 +/- 0.5 h following the first dose and resulted in a significant rise of somatomedin C. free fatty acids, fasting blood glucose and insulin concentrations. Bio-hGH administration resulted in a significant increase in body weight (80.0 +/- 4.5 to 81.1 +/- 4.3 kg; P less than 0.01) which was associated with a marked reduction in urinary sodium excretion (196 +/- 38 to 45 +/- 20 mmol/day; P less than 0.025). Serum T3 increased during bio-hGH administration and was associated with reciprocal changes in free thyroxine and TSH concentrations. Cardiac, hepatic, renal, biochemical, haematological, endocrinological and immunological functions remained normal throughout the study. No antibodies to hGH or to host cell protein developed during the study. The results show that bio-hGH is safe in the short term, well tolerated, possesses pharmacokinetic and biological properties similar to pituitary hGH, and has distinct effects on sodium balance and on thyroid function. This study stresses the need to monitor patients for effects on sodium retention, carbohydrate metabolism and thyroid function when using hGH doses of 1.0 U/kg/week (40 U/m2/week) or more in patients with GH responsive short stature.

Adult

Phospholipid, nature's own slide and cover slip for cryo-electron microscopy.

Thin films of surface-active compounds, with or without particulate material, can be obtained by immersing and withdrawing a bare specimen grid from a solution/suspension of the compound. Immediately after withdrawing the grid, thinning of the film starts. Thinning is initially powered by gravity and capillary forces and will proceed in thin films (less than 100 nm) driven by intermolecular forces until the London-van der Waals attractive forces come to an equilibrium with electrostatic repulsion of similarly charged surfaces of the film. With small unilamellar vesicles prepared from the phospholipid dimyristoyl phosphatidyl choline (DMPC) the draining behaviour of these films was studied by cryo-electron microscopy. Small unilamellar vesicles were observed within the film as well as the coalescence of these vesicles into sheets ('leaky' membrane fusion). Sheets dominate the images when films are allowed to drain for longer periods (greater than 3 min). Thin films were formed on grids from catalase crystals suspended in a DMPC suspension and vitrified by cooling. High-resolution information was obtained by electron diffraction at low temperature and under low-dose conditions from catalase crystals surrounded by small vesicles as well as from catalase crystals surrounded by sheets of DMPC. In the latter case the water content drops from 99% (DMPC in small vesicles) to less than 30% (DMPC in sheets) during draining. Ferritin was added to a DMPC suspension and thin films were prepared and vitrified. After prolonged draining ferritin molecules were deposited in layers with a stepwise increase in thickness. Draining of thin films has thus a dehydrating effect as well as a sorting and ordering effect. These effects must be considered when using surface-active compounds at air-water interfaces as a slide and cover slip for electron microscopy.

Catalase

Formation of multilamellar vesicles by addition of tannic acid to phosphatidylcholine-containing small unilamellar vesicles.

Tannic acid induces aggregation and formation of multilamellar vesicles when added to preparations of small unilamellar vesicles, specifically those containing phosphatidylcholine. Aggregation and clustering of vesicles was demonstrated by cryo-electron microscopy of thin films and by freeze-fracture technique. Turbidity measurements revealed an approximately one-to-one molar ratio between tannic acid and phosphatidylcholine necessary for a fast and massive aggregation of the small unilamellar vesicles. When tannic acid-induced aggregates were dehydrated and embedded for conventional thin-section electron microscopy, multilamellar vesicles were retrieved in thin sections. It is concluded from morphological studies, as well as previous tracer studies, that tannic acid, at least to a great extent, prevents the extraction of phosphatidylcholine. Multilamellar vesicles were also observed in tannic acid-treated vesicles prepared from total lipid extracts from either rabbit or rat hearts. Substantially more multilamellar vesicles were retrieved in the rabbit vesicle preparation. This difference can probably be explained by the difference in the proportion of the plasmalogen phosphatidylcholine, and possibly the content of sphingomyelin, in lipid extracts of rabbit and rat hearts. It is concluded that the dual effect (reduced extraction and aggregation) of tannic acid on phosphatidylcholines should be taken into consideration when tannic acid is used in tissue preparation.

Animals

Heterophilic antibodies: a problem for all immunoassays.

We verified that antibody-binding substances in serum that interfere in two-site immunoassays involving murine antibodies are heterophilic antibodies. Incubation of serum containing heterophilic antibodies and a murine monoclonal antibody to human choriogonadotropin (hCG) leads to formation of a series of soluble immune complexes. We investigated the recognition of hCG by reagent antibody in the presence of heterophilic antibodies and found this recognition to be diminished. Consequently, about 30% of serum samples containing heterophilic antibodies falsely appear to contain increased concentrations of hCG. The effect on analyte recognition probably results from steric inhibition of hCG binding to complexed antibody. Heterophilic antibodies detected with a murine antibody also bound immunoglobulin from several other species but did not bind all of those tested.

Animals

Circulating insulin-like growth factor I levels in newborn premature and full-term infants followed longitudinally.

Longitudinal circulating levels of insulin-like growth factor I (IGF-I) were measured by radioimmunoassay after acid/ethanol extraction of serum or plasma in 44 appropriate-for-gestational age (AGA) premature infants, 7 small-for-gestational age (SGA) premature infants and 9 AGA full-term infants. The subjects were divided into cohorts with gestational age at birth 26-29 weeks, 30-33 weeks, 34-37 weeks and 38-42 weeks (full-term). The premature infants in this study exhibited diminished growth as compared with normal intrauterine growth. In all but the earliest premature infant cohort there was an immediate fall from the mean fetal IGF-I level, as reflected by the cord value, to a basal postnatal circulating level of IGF-I. The basal level of circulating IGF-I in premature infants was related only to gestational age. It increased slowly from 25 weeks gestation until four weeks after full-term equivalent and was independent of time of birth. Full-term infants were distinguished from early premature infants by the occurrence of a prominent postnatal surge in circulating IGF-I levels that was characterised by a significant (P less than 0.02) increase between day 1 and days 10-15. The SGA and AGA infants in the 34-37 week cohort showed similar profiles of circulating IGF-I with no significant difference in cord values between the two groups.

Gestational Age

Localization of human pituitary hormones by multiple immunoenzyme staining procedures using monoclonal and polyclonal antibodies.

Mouse monoclonal and rabbit polyclonal antibodies to human pituitary hormones were applied together to sections of normal and neoplastic human pituitary tissue. Binding sites were revealed with species-specific immune reagents combined with various enzymes (peroxidase, alkaline phosphatase, and beta-D-galactosidase). The enzymes were developed separately to give differently colored end-products. Where two hormones were present in the same cell, a mixed color was produced. Up to four hormones could be immunostained in a single section. Multiple immunoenzymatic staining has great potential for the analysis of plural antigen production by single cells and relationships between cells producing different antigens.

Animals

Error in laboratory reference limits as shown in a collaborative quality-assurance program.

Laboratories participate in collaborative quality-assurance programs to maintain and improve the quality of their diagnostic assays, but little attention has been paid to diagnostic quality in these programs. We used a national quality-assurance program to assess the quality of laboratory reference intervals as exemplified by triiodothyronine, thyroxin, and thyrotropin immunoassays. The limits of the reference intervals used by laboratories bear virtually no relationship to laboratory bias, i.e., whether assays read "high" or "low." Further, correcting assay results from different laboratories for the reference limits used increases rather than decreases interlaboratory scatter. We conclude that the analytical quality of immunoassays now exceeds the quality of the reference limits supplied to clinicians to assist diagnosis, and that nationally or internationally defined reference limits would therefore provide more information at less cost than do individual laboratory reference limits.

Humans

Incidence and specificity of interference in two-site immunoassays.

Using a modified "two-site" immunoradiometric assay, termed an "interference assay," we have demonstrated the occurrence of non-analyte antibody-binding substances in approximately 40% of serum samples. These substances multivalently bind antibodies from any of several species at a site other than the antigen-binding site. Using a two-site immunoradiometric assay for human choriogonadotropin, we have investigated their effect on analyte quantification. In this system these antibody-binding substances mimic the presence of analyte; when analyte is actually present, they can also cause over- or underestimates. Addition of excess nonspecific immunoglobulin from an appropriate species eliminates this interference. However, the amount of nonspecific immunoglobulin added to an assay system may not always be enough to block interference in all samples.

Adult

Covert cross reactants in a two-site immunoassay studied with monoclonal antibodies.

A one-step two-site immunoradiometric assay for the measurement of free beta subunit of human chorionic gonadotrophin (beta-hCG) was developed using monoclonal antibodies. The immobilized antibody was specific for free beta subunit and the radiolabeled antibody recognized both intact human chorionic gonadotrophin (hCG) and free beta subunit. Although the level of hCG "cross-reaction" was low when studied using conventional techniques, the apparent beta-hCG content of samples was found to be inversely proportional to the hCG level. From both experimental evidence and computer simulation studies this was found to be due to the binding of hCG to the limited amount of 125I-labeled antibody present. The term covert cross reactants has been introduced to describe substances which bind to only one of the antibodies in a two-site immunoassay. When establishing such an assay the effect of covert cross reactants on the response of an analyte should be investigated.

Antibodies, Monoclonal

The production of high affinity monoclonal antibodies to human growth hormone.

The primary aim of this work was to produce specific monoclonal antibodies to human growth hormone (hGH) for use in a diagnostic RIA of hGH levels in serum. Three different schedules were used for immunization of BALB/c mice and the splenocytes from each mouse were fused with myeloma cells Sp 2/0 Ag 14. Each fusion resulted in the production of hundreds of hybridomas secreting hGH-directed antibodies. Six antibodies have been fully characterized and have been grouped into pairs which recognize 3 different epitopes on the hGH molecule. One pair exhibits no cross reaction with the structurally related placental hormone, human placental lactogen (hPL), a second pair has low cross reaction with hPL (1.6-3%) and a third pair reacts equally well with hGH and hPL indicating binding to a common epitope in the 2 molecules. The highest affinity antibody, 74/6, which has an affinity constant of 4.4 X 10(10) l/mol and 3% cross-reactivity with hPL, has been used to establish a RIA for serum hGH measurements. Evidence is provided that hGH levels measured in this assay correlate well with those obtained in a conventional rabbit antiserum assay.

Animals

The production of monoclonal antibodies to human chorionic gonadotrophin and its subunits.

The difficulties encountered in producing highly specific antisera to human chorionic gonadotrophin (hCG) were overcome by the use of hybridoma technology. A panel of monoclonal antibodies directed toward hCG and its subunits was produced. Of the four antibodies which were fully characterized, one recognized the intact hCG molecule only, a second recognized only the free beta-subunit, a third recognized only the free alpha-subunit and the fourth bound to the beta-subunit of hCG both when it was in the free form and when it was associated with the alpha-subunit forming the intact hCG molecule. There was no significant cross-reaction of any of these antibodies with the pituitary glycoprotein hormones. The four antibodies had high binding affinities which should permit their use in immunoassays for measurement of circulating levels of hCG and its subunits.

Animals

Use of immunoaffinity chromatography for purification of 125I-labeled human prolactin.

We assessed a simple method for purifying 125I-labeled human prolactin, taking advantage of the abundant supplies of monoclonal antibodies available. 125I-Labeled human prolactin purified by immunoaffinity chromatography is compared with that purified by gel filtration on Sephadex G-100. We used monoclonal antibodies to prolactin to prepare the affinity chromatography columns. Prolactin was radiolabeled by the Chloramine T method, purified by each of the above procedures, and the binding and displacement characteristics were studied in radioimmunoassays in which either monoclonal antibodies or a rabbit anti-prolactin serum was the first antibody. A nonimmune fraction of 125I-labeled prolactin that co-eluted with the immunoreactive hormone from Sephadex G-100 was removed by affinity chromatography, which increased the antibody binding of 125I-labeled prolactin in the radioimmunoassay in the absence of unlabeled antigen (B/T0, in percent) twofold or more, increased the assay sensitivity, and increased the slope of antigen displacement measured by the 50% intercept. Several advantages make this the purification method of choice.

Antibodies, Monoclonal

A monoclonal antibody suitable for the radioimmunoassay of prolactin in human serum.

Monoclonal antibodies directed toward human PRL (hPRL) have been produced by fusion of mouse myeloma cells (Sp2/0-Ag 14) with spleen cells from mice immunized with hPRL. Total immunizing doses of 20 microgram and 64 microgram hPRL resulted in the production of three highly specific hPRL antibodies. The high affinity antibody, with a Ka value of 0.23 X 10(10) M-1, was used to establish a RIA highly suitable for the measurement of hPRL levels in human serum. The correlation of serum hPRL levels measured using the antibody and those in a conventional rabbit anti-hPRL assay was 0.99 (y = 1.16 - 7.2). These results demonstrate that using the mouse hybridoma technique, it is possible to produce high affinity monospecific monoclonal antibody suitable for the measurement of hPRL in human serum.

Antibodies, Monoclonal

Lectins used to prepare serum free of glycoprotein hormones for use as a matrix in radioimmunoassay.

Hormone-free serum is required for use as a matrix for standards in the radioimmunoassay of hormones. The glycoprotein hormones are difficult to remove from serum by conventional techniques. We exploited the specific binding of carbohydrates by lectins to extract glycoprotein hormones from human serum. Passing serum over Concanavalin A Sepharose efficiently removed lutropin and the beta subunit of choriogonadotropin. Wheat-Germ Lectin Sepharose completely removed these, and also follitropin and thyrotropin. The latter treatment is shown to provide a suitable matrix for standards in radioimmunoassays of the four hormones.

Blood Chemical Analysis