Expression of VEGFR-2 and AC133 by circulating human CD34(+) cells identifies a population of functional endothelial precursors.

Emerging data suggest that a subset of circulating human CD34(+) cells have phenotypic features of endothelial cells. Whether these cells are sloughed mature endothelial cells or functional circulating endothelial precursors (CEPs) is not known. Using monoclonal antibodies (MoAbs) to the extracellular domain of the human vascular endothelial receptor-2 (VEGFR-2), we have shown that 1.2 +/- 0.3% of CD34(+) cells isolated from fetal liver (FL), 2 +/- 0.5% from mobilized peripheral blood, and 1.4 +/- 0.5% from cord blood were VEGFR-2(+). In addition, most CD34(+)VEGFR-2(+) cells express hematopoietic stem cell marker AC133. Because mature endothelial cells do not express AC133, coexpression of VEGFR-2 and AC133 on CD34(+) cells phenotypically identifies a unique population of CEPs. CD34(+)VEGFR-2(+) cells express endothelial-specific markers, including VE-cadherin and E-selectin. Also, virtually all CD34(+)VEGFR-2(+) cells express the chemokine receptor CXCR4 and migrate in response to stromal-derived factor (SDF)-1 or VEGF. To quantitate the plating efficiency of CD34(+) cells that give rise to endothelial colonies, CD34(+) cells derived from FL were incubated with VEGF and fibroblast growth factor (FGF)-2. Subsequent isolation and plating of nonadherent FL-derived VEGFR-2(+) cells with VEGF and FGF-2 resulted in differentiation of AC133(+ )VEGFR-2(+) cells into adherent AC133(-)VEGFR-2(+)Ac-LDL(+ )(acetylated low-density lipoprotein) colonies (plating efficiency of 3%). In an in vivo human model, we have found that the neo-intima formed on the surface of left ventricular assist devices is colonized with AC133(+)VEGFR-2(+) cells. These data suggest that circulating CD34(+) cells expressing VEGFR-2 and AC133 constitute a phenotypically and functionally distinct population of circulating endothelial cells that may play a role in neo-angiogenesis.

AC133 Antigen↗

Surgical alternatives to transplantation and assist devices in the treatment of heart failure.

It is estimated that in the United States 30,000 patients with end-stage heart disease are eligible for heart transplantation, although less than 2500 are actually performed each year. As the population ages, several thousand other patients who are ineligible for cardiac transplantation will be left with limited options. Surgical strategies aimed at halting the progression of heart failure have therefore been devised. High-risk coronary artery bypass grafting can improve ejection fraction and alleviate heart failure symptoms in appropriately selected patients. Mitral valve repair and ventricular aneurysm resection/plication procedures may improve heart failure by decreasing the volume load on the left ventricle. Myoreduction operations (Batista operation) aim to improve the volume and wall stress relationship of the dilated left ventricle, but their clinical application has remained experimental.

Coronary Artery Bypass↗

Controlled clinical trial of a novel hemostatic agent in cardiac surgery. The Fusion Matrix Study Group.

BACKGROUND: We performed a prospective randomized trial to compare FloSeal Matrix (Fusion Medical Technologies, Inc, Mountain View, CA), a gelatin-based hemostatic sealant, with Gelfoam-Thrombin (Gelfoam, Pharmacia and Upjohn, Kalamazoo, MI; Thrombin, Gentrac Inc, Middeton, WI) (control group) to control perioperative bleeding. METHODS: A total of 93 patients undergoing cardiac operations were randomized into the FloSeal or control group after standard surgical means to control bleeding had failed. The bleeding site was evaluated at 1, 2, 3, 6, and 10 minutes after applying the hemostatic agent. If bleeding stopped within 10 minutes, the application was considered to be successful. In the case of a failure, the surgeon could use any means preferred (except FloSeal) to achieve hemostasis. All bleeding sites in a patient were treated with the hemostatic agent to which the patient was randomized. Follow-up evaluation was performed at 12 to 36 hours and 6 to 8 weeks after operation. RESULTS: FloSeal stopped bleeding in 94% of the patients (first bleeding site only) within 10 minutes, compared to 60% in the control group (p = 0.001). At 3 minutes, successful hemostasis was achieved in 72% of the FloSeal group compared with 23% in the control group (p = 0.0001). There was no difference in the adverse event profile between the two groups. CONCLUSIONS: FloSeal Matrix demonstrated efficacy superior to that of Gelfoam-Thrombin and had a safety profile similar to that of Gelfoam-Thrombin when used as a topical hemostatic agent during cardiac surgery procedures.

Blood Loss, Surgical↗

A randomized trial of antithrombin concentrate for treatment of heparin resistance.

BACKGROUND: Heparin resistance is an important clinical problem traditionally treated with additional heparin or fresh frozen plasma. We undertook a randomized clinical trial to determine if treatment with antithrombin (AT) concentrate is effective for treating this condition. METHODS: Patients requiring cardiopulmonary bypass who were considered to be heparin resistant (activated clotting time < 480 seconds after > 450 IU/kg heparin) were randomized to receive either 1000 U AT or additional heparin. RESULTS: AT concentrate was effective in 42 of 44 patients (96%) for immediately obtaining a therapeutic activated clotting time. This compared favorably to 28 of 41 patients (68%) treated with additional heparin (p = 0.001). All patients who failed heparin therapy were successfully treated with AT. The patients receiving AT required less time to obtain an adequate ACT but there was no difference in clinical outcomes among the groups. Study patients had deficient AT activity at baseline (56%+/-25%), which improved in those given AT concentrate (75%+/-31% versus 50%+/-23%, p < 0.0005). CONCLUSIONS: Heparin resistance is frequently associated with AT deficiency. Treating this deficiency with AT concentrate is more effective and faster for obtaining adequate anticoagulation than using additional heparin.

Antithrombins↗

Recurrent remodeling after ventricular assistance: is long-term myocardial recovery attainable?

BACKGROUND: Long-term left ventricular assist devices (LVAD) have been used both as a bridge to heart transplantation and to recovery of native myocardial function. Despite much evidence for reversal of some of the structural and functional changes present in the failing heart during LVAD support, clinical evidence for sustained myocardial recovery is scant. We describe 2 patients in whom myocardial recovery during LVAD support led to device explanation only to have heart failure recur. This necessitated a second LVAD implantation, a process that we have termed recurrent remodeling. METHODS: The medical records of 2 patients with cardiomyopathy supported with HeartMate LVADs (Thermo Cardiosystems, Inc, Woburn, MA) were retrospectively reviewed. RESULTS: One patient was supported with an LVAD for 2 months, at which time the LVAD was explanted. Progressive deterioration of cardiac function followed, requiring a second LVAD 19 months after LVAD explanation. After 2 months of further LVAD support, a second episode of apparent myocardial recovery was observed during a period of device malfunction. The other patient was supported with an LVAD for 12 months, at which time the LVAD was explanted. The patient experienced progressive hemodynamic deterioration and required a second LVAD 6 months after LVAD explantation. Heart transplantations of both patients were successful. CONCLUSIONS: Our understanding of myocardial recovery in the setting of hemodynamic unloading with LVAD support has not yet progressed to the point where we are able to accurately predict successful long-term LVAD explantation. The evolution of reliable predictors of sustainable myocardial recovery will help to avoid further cases of recurrent remodeling requiring repeat LVAD implantation.

Adult↗

Effects of mast cell membrane stabilizing agents in a rat lung ischemia-reperfusion model.

BACKGROUND: The aim of this study was to test the hypothesis that agents which stabilize the mast cell membrane may modulate the phenotype of the vascular wall in a lung ischemia-reperfusion model, including altering expression of endothelial and leukocyte adhesion receptors and the inducible nitric oxide synthase (NOS-2). METHODS: Three sets of rats were given either intravenous saline (group A), ketotifen (group B), or cromolyn (group C), respectively. The left pulmonary artery was ligated temporarily and reopened after 2 hours of ischemia. Then, after a 2-hour period of reperfusion, the left lung was excised. ICAM-1 and NOS-2 were measured at the protein level by Western blotting, and cGMP levels were measured by enzyme-linked immunosorbent assay in the lung tissue specimens for each drug group. RESULTS: ICAM-1 expressions, determined as the intensity of a given band on the Western blot, were 197+/-59 in group B and 195+/-83 in group C versus 369+/-114 in group A (p = 0.002 for analysis of variance). In contrast with ICAM-1, NOS-2 expression was increased by ketotifen or cromolyn treatment (464+/-82 in group B and 507+/-93 in group C, compared with 377+/-44 for group A, p = 0.007). The finding of increased NOS-2 expression in groups B and C is consistent with the observed increase in tissue cGMP levels in the same groups (1.92+/-0.9 pmol/mL for group A versus 7.8+/-3.5 pmol/mL for group B, and 12.4+/-5.8 pmol/mL for group C, p = 0.0004). CONCLUSIONS: These data establish that mast cell stabilizing agents modulate the vascular phenotype in the setting of pulmonary ischemia and reperfusion by decreasing ICAM-1 expression, augmenting expression of NOS-2, and increasing tissue cGMP levels. As decreasing ICAM-1 expression and increasing cGMP levels have proven useful to limit proinflammatory mechanisms of tissue injury, mast cell stabilizing agents may provide a new therapeutic option to improve organ function in the setting of reperfusion.

Analysis of Variance↗

Arginine vasopressin in the treatment of 50 patients with postcardiotomy vasodilatory shock.

BACKGROUND: The barroreflex-mediated secretion of arginine vasopressin has been found to be defective in a variety of vasodilatory shock states, such as postcardiotomy shock, and administration of the hormone markedly improves vasomotor tone and blood pressure. The high incidence of vasodilatory shock in patients undergoing left ventricular assist device (LVAD) implantation makes this population an ideal model in which to assess the risks and benefits of vasopressin. METHODS: The medical records of the 102 patients receiving LVADs at Columbia-Presbyterian Medical Center from January 1995 to August 1998 were reviewed. Fifty patients were eligible for study based on a history of arginine vasopressin administration in the operating room or intensive care unit within 24 hours of implantation. RESULTS: Despite LVAD implantation and the administration of vasopressors, patients were hypotensive with a mean arterial pressure less than 60 mm Hg. The administration of vasopressin (0.09+/-0.05 U/min) increased mean arterial pressure (58+/-13 to 75+/-14 mm Hg; p<0.001) while reducing norepinephrine administration (11.7+/-13 to 7.9+/-6.0 mcg/min; p = 0.023). There was no significant change in LVAD flow. The incidence of compromised regional perfusion was not different between LVAD patients who received vasopressin as compared to hemodynamically stable LVAD patients who did not receive vasopressin. CONCLUSIONS: We have demonstrated vasopressin at low doses to be a safe and an effective vasopressor in 50 patients with postcardiotomy vasodilatory shock.

Arginine Vasopressin↗

Multicenter review of preoperative risk factors for stroke after coronary artery bypass grafting.

BACKGROUND: Stroke complicates the postoperative course in 1% to 6% of patients undergoing coronary revascularization. There has been no large scale mandatory database reporting on the incidence of stroke after coronary revascularization. METHODS: A multicenter regional database from the Bureau of Health Care Research Information Services, New York State Department of Health, on 19,224 patients who underwent coronary revascularization in 31 hospitals within New York State during 1995 was analyzed to determine the risk factors for postoperative stroke. RESULTS: The incidence of postoperative stroke was 1.4% (n = 270). Hospital mortality for patients who had a stroke was 24.8%, compared with 2.0% for the rest of the patient population. Postoperative stroke increased the hospital length of stay threefold (27.9+/-1.9 versus 9.1+/-0.9 days, p<0.0001). Multivariable logistic regression identified the following variables to be significantly associated with a postoperative stroke: calcified aorta (p<0.0001; odds ratio [OR], 3.013), prior stroke (p = 0.0003; OR, 1.909), age (p<0.0001; OR, 1.522 per 10 years), carotid arterial disease (p = 0.002; OR, 1.590), duration of cardiopulmonary bypass (p = 0.0004; OR, 1.27 per 60 minutes), renal failure (p = 0.0062; OR, 2.032), peripheral vascular disease (p = 0.0157; OR, 1.62), cigarette smoking (p = 0.0197; OR, 1.621), and diabetes mellitus (p = 0.0158; OR, 1.373). CONCLUSIONS: Postoperative stroke increases mortality and length of stay after coronary revascularization. Several risk factors can be identified, and some of these factors are potentially amenable to intervention, either before or during coronary revascularization, and should also influence patient selection.

Adult↗

Six-year experience of caring for forty-four patients with a left ventricular assist device at home: safe, economical, necessary.

OBJECTIVE: With increasing numbers of implantations, left ventricular assist device programs can put a financial strain on a hospital unless an efficient and safe outpatient program is developed. However, the left ventricular assist device is not widely recognized in the medical community as being reliable enough to support a patient at home. We reviewed our experience with these patients at home to assess the safety and the benefits of such a program. METHODS: Our institutional 6-year experience with 90 consecutive recipients of a wearable left ventricular assist device was analyzed. RESULTS: Forty-four (49%) of the 90 patients who received TCI vented-electric left ventricular assist devices (Thermo Cardiosystems, Inc, Woburn, Mass) were discharged, spending a total of 4546 days (12.5 years) at home with an average of 103 +/- 16 days of outpatient support (range 9-436 days). Of these 44 patients, all were successfully bridged to transplantation (42 patients, 96%) or planned explantation (2 patients, 4%). None of the outpatients died. The cumulative events per outpatient month were 0.020 for bleeding, 0.053 for device infection, 0.0068 for thromboembolus, and 0.020 for major malfunctions. Our estimated average cost to bridge a patient to transplantation or explantation once discharged is $13,200 and as an inpatient over the same length of time, including only room and board, is $165,200. Thirty percent of outpatients were able to return to work or school, 33% to sexual activity, and 44% to driving. All outpatients performed activities of daily living. CONCLUSION: Current left ventricular assist device technology provides effective and economical outpatient support and is associated with limited morbidity and a satisfactory quality of life.

Ambulatory Care↗

Endothelial adhesivity, pulmonary hemodynamics and nitric oxide synthesis in ischemia-reperfusion.

OBJECTIVE: Alterations in nitric oxide synthesis, endothelial adhesivity and pulmonary hemodynamics are investigated in an animal model of lung ischemia-reperfusion. METHODS: Two sets of rats, each containing seven animals, were either subjected to unilateral pulmonary ischemia and reperfusion (Study Group) or underwent the same surgical procedure without ischemia (Control Group). Pulmonary artery pressure (PAP), pulmonary blood flow (PBF) trend, NOS-2, intercellular adhesion molecule-1 (ICAM-1), myeloperoxidase (MPO) and cGMP expression of the reperfused lung tissue and, final paO(2) were compared between the two groups. RESULTS: ICAM-1 expression was increased (369+/-114 vs. 115+/-65; P=0.02), NOS-2 expression and tissue cGMP levels were decreased (377+/-44 vs. 452+/-54; P=0.03 and 7.8+/-3.5 vs. 9.4+/-2.3 pmol/ml; P=0.03, respectively) and MPO activity was increased (2.7+/-0.9-3.5+/-0.8; P=0.03) in the reperfused lungs. Pulmonary artery pressure was 15+/-7 mmHg in the Control Group vs. 22+/-16 mmHg in the Study Group (P=0.04) at the 30th min of reperfusion. Pulmonary blood flow was greater in the Study Group at the beginning of reperfusion (9.5+/-4.1 vs. 7.1+/-3.1 ml/min at the 30th min) but considerably reduced thereafter (3.2+/-1. 4 vs. 6.2+/-2.1 at the 60th minute and 2.9+/-1.6 vs. 5.8+/-1.9 at the 120th min). At the end of the experiment, paO(2) was 95+/-30 in the Control Group vs. 71+/-32 in the Study Group (P=0.03). CONCLUSIONS: These data establish that nitric oxide synthesis was suppressed after reperfusion. Pulmonary blood flow was first increased and then reduced. A parallel increase in MPO and ICAM-1 indicated proinflammatory reaction. Decreased tissue cGMP level was consistent with the suppressed NOS-2 production. Organ function was negatively influenced as represented by the decreased oxygenation, probably due to no-reflow phenomenon.

Animals↗

Implantable left ventricular assist devices can successfully bridge adolescent patients to transplant.

BACKGROUND: Left ventricular assist devices (LVAD) have been used successfully as a life-sustaining bridge to transplantation in adults with end-stage heart failure. Long-term implantable cardiac assist devices for smaller adolescent patients are not yet available in the United States. METHODS: This study reviews the experience with patients less than 21 years old that received HeartMate LVADs (TCI) at our institution. Twelve patients were implanted with 13 LVADs. The patients ranged in age from 11 to 20 years (mean 16 years). Body surface area ranged from 1.4 to 2.2 m2 (mean 1.8 m2). Patients were selected for LVAD placement based on eligibility for heart transplant and evidence of end-organ dysfunction. Device placement in small patients was facilitated with prosthetic graft abdominal wall closure. No patient received systemic anticoagulation. RESULTS: The duration of LVAD support ranged from 0 to 397 days (mean 123 days). Seven of the 8 patients eligible for discharge from the hospital with a vented-electric LVAD were supported at home while awaiting transplantation. Outcomes of LVAD support were: LVAD explantation in 2 cases (15%), expiration with LVAD in place in 3 cases (23%), and successful transplantation in 8 cases (62%). Complications included 4 patients with systemic infection, 3 re-operations for hemorrhage, 1 embolic event, and 1 intraoperative air embolus that proved fatal. One explanted patient required a subsequent LVAD and the other expired 4 months after explantation. Six of the 8 transplanted patients are alive and well with follow-up ranging from 8 to 43 months. CONCLUSIONS: Adolescent patients with heart failure can be successfully supported on a long-term basis to heart transplantation with the HeartMate LVAD. The wearable device allows for discharge home while awaiting transplantation. Device explantation without subsequent transplantation can be unpredictable. The incidence of thromboembolism remains low despite the absence of systemic anticoagulation. The technique of prosthetic graft closure of the abdominal wall facilitates the use of this device in smaller patients.

Adolescent↗

Mechanical support for postcardiotomy cardiogenic shock.

Postcardiotomy cardiogenic shock (PCCS) results in substantial morbidity and mortality. Despite intraaortic balloon pump and inotropic support, some patients with PCCS continue to have a refractory low cardiac output. For these patients, more effective ventricular assistance is imperative to prevent death. Multiple systems are available for the short-term support of patients with PCCS. Regardless of the device employed, only 25% of these patients survive and are discharged home. Two strategies, however, may improve the outcome of PCCS. One is long-term support by an implantable assist device, which can allow optimal ventricular unloading. Unfortunately, not all cardiac surgery centers offer this type of support. Therefore, the other strategy is the creation of postcardiotomy referral centers that offer long-term support or heart transplantation. Such centers would conserve scarce donor organs, maximize the chance of myocardial recovery, and yield expertise applicable not only to device recipients but also to critically ill heart-failure patients who do not need an implantable pump.

Cardiac Surgical Procedures↗

Use of alternative medicine by patients undergoing cardiac surgery.

OBJECTIVE: Complementary and alternative medicine may influence cardiac surgical care by inducing coagulopathies and interacting with perioperative medications. We evaluated the significance of complementary and alternative medicine use in an acutely ill cardiac surgical population and assessed the willingness of patients to reveal these activities to their physicians and surgeons. METHODS: A total of 376 consecutive patients undergoing preoperative or postoperative cardiothoracic surgical evaluations at an urban academic medical center were approached to complete a survey regarding use and attitudes toward complementary and alternative medicine. All surveys were administered and collected between March and May 1998. RESULTS: Completion rate was 70% (n = 263). Respondents were predominantly male (72%), white (76%), and well educated (59%). The overall rate of complementary and alternative medicine use was 75%, but excluding prayer and vitamins, which are often not considered complementary and alternative medicine therapies, the rate was 44%. There was no correlation between the use of complementary and alternative medicine and the parameters of gender, age, race, or education level. Only 17% responded that they had discussed complementary and alternative medicine with their physicians, and 48% responded that they did not want to discuss the topic at all. CONCLUSIONS: Complementary and alternative medicine is used as frequently in patients undergoing cardiac surgery, as in the general population. Physicians and surgeons should be aware that patients have no inherent predisposition toward or against using complementary and alternative medicine, but that they are unlikely to volunteer their experience with it. The unwillingness of patients to discuss complementary and alternative medicine with physicians has serious implications for their safety, especially in acute care situations.

Adult↗

Impact of current management practices on early and late death in more than 500 consecutive cardiac transplant recipients.

OBJECTIVE: To study risk factors for early and late death after heart transplantation in the current era. SUMMARY BACKGROUND DATA: The current cardiac transplant population differs from earlier periods in that an increasing number of sicker patients, such as those with ventricular assist device (LVAD) support, prior cardiac allotransplantation, and pulmonary hypertension, are undergoing transplantation. In addition, sensitized patients constitute a greater proportion of the transplanted population. Emphasis has been placed on therapies to prevent early graft loss, such as the use of nitric oxide and improved immunosuppression, in addition to newer therapies. METHODS: Five hundred thirty-six patients undergoing heart transplantation between 1993 and 1999 at a single center were evaluated (464 adults and 72 children; 109 had received prior LVAD support and 24 underwent retransplantation). The mean patient age at transplantation was 44.9 years. Logistic regression and Cox proportional hazard models were used to evaluate the following risk factors on survival: donor and recipient demographics, ischemic time, LVAD, retransplantation, pretransplant pulmonary vascular resistance, and immunologic variables (ABO, HLA matching, and pretransplant anti-HLA antibodies). RESULTS: The rate of early death (less than 30 days) was 8.5% in adults and 8.8% in children. The actuarial survival rate of the 536 patients was 83%, 77%, and 71% at 1, 3, and 5 years, respectively, by Kaplan Meier analysis. Risk factors adversely affecting survival included the year of transplant, donor age, and donor-recipient gender mismatching. Neither early nor late death was influenced by elevated pulmonary vascular resistance, sensitization, prior LVAD support, or prior cardiac allotransplantation. CONCLUSIONS: Previously identified risk factors did not adversely affect short- or long-term survival of heart transplant recipients in the current era. The steady improvement in survival during this period argues that advances in transplantation have offset the increasing acuity of transplant recipients.

Adolescent↗

Vasopressin as an alternative to norepinephrine in the treatment of milrinone-induced hypotension.

OBJECTIVE: To determine whether vasopressin could be effective in treating the hypotension associated with phosphodiesterase III inhibition. Phosphodiesterase III inhibitors are cardiotonic agents that increase myocardial contractility and decrease vascular smooth muscle tone. The vasodilatory effect can be profound, and the resulting hypotension frequently requires the administration of catecholamine pressors. DESIGN: Retrospective analysis of existing data. SETTING: The medical or surgical intensive care unit of Columbia-Presbyterian Medical Center. PATIENTS: Three consecutive patients receiving milrinone and requiring catecholamine pressors to maintain systolic arterial pressure of > or =90 mm Hg. INTERVENTIONS: Vasopressin was administered to the three patients. MEASUREMENTS AND MAIN RESULTS: Vasopressin (0.03-0.07 units/min) increased systolic arterial pressure from 90+/-4.7 to 130+/-2.3 mm Hg while reducing the administration of catecholamine pressors. CONCLUSIONS: Vasopressin at very low doses appears to be an effective vasopressor for milrinone-induced hypotension.

Aged↗

Incidence of atrial fibrillation after mild or moderate hypothermic cardiopulmonary bypass.

OBJECTIVES: Atrial fibrillation remains a significant source of morbidity after coronary artery bypass grafting (CABG). Whether cardiopulmonary bypass (CPB) temperature influences the occurrence of postoperative atrial fibrillation in CABG patients has not been specifically examined. In the present study, we reviewed postoperative data from patients who were prospectively randomized to mild or moderate hypothermic CPB for elective CABG to determine the incidence of postoperative atrial fibrillation. DESIGN: Randomized, single center, observational study. SETTING: Tertiary university medical center. PATIENTS: Adults undergoing elective CABG surgery. INTERVENTIONS: Enrolled patients were prospectively randomized to mild (34 degrees C [93.2 degrees F]) or moderate (28 degrees C [82.4 degrees F]) hypothermic CPB. MEASUREMENTS AND MAIN RESULTS: The incidence of postoperative atrial fibrillation was determined by review of ICU and hospital records. There was a significantly higher incidence of atrial fibrillation in the moderate compared with the mild hypothermic CPB group. Patients who had postoperative atrial fibrillation were significantly older than those without atrial fibrillation. Furthermore, a significant increase in the relative risk of developing postoperative atrial fibrillation was found for both age and CPB temperature. CONCLUSIONS: Our results indicate that the temperature of systemic cooling during CPB is an important factor in the development of atrial fibrillation after CABG surgery. In addition, this study confirms that increasing age is a significant determinant of postoperative atrial fibrillation.

Adult↗

Transaortic repair of mitral regurgitation.

BACKGROUND: In the operative management of mitral regurgitation (MR) associated with aortic valve disease, a transaortic approach combining the bowtie mitral valve repair with replacement of the aortic valve appears to offer a less invasive and technically simple, expeditious alternative to conventional left atriotomy and Carpentier style repair. METHODS: Between February 1997 and December 1999, four patients underwent a bowtie repair of the mitral valve via the aortic root with concomitant aortic valve replacement. The diagnosis of MR was established and followed postoperatively by echocardiogram. The operative technique involved a transaortic annular approach to the mitral valve with a single edge-to-edge suture approximating the prolapsing posterior mitral leaflet to a normal segment of the anterior leaflet. RESULTS: There were no operative mortalities. Mean cross-clamp time for both valve procedures was 104 +/- 24 min and cardiopulmonary bypass was 155 +/- 31. Mean postoperative cardiac output was 5 +/- 1 L/min. Semiquantitative estimation of mitral regurgitation by doppler improved from a mean of 3.2 +/- 0.5 preoperatively to a mean of 0.25 +/- 0.5 (p = 0.0052) postoperatively, while ejection fraction (EF) remained stable (48 +/- 9% preoperatively and 49 +/- 9% prior to discharge). One patient with rheumatic mitral pathology had a mild increased mitral gradient which did not resolve with takedown of the bowtie repair. Mitral stenosis was not evident in any of the other patients. CONCLUSIONS: Our initial experience with the combined transaortic bowtie repair and aortic valve replacement has demonstrated that this approach is very quick, feasible, effective, and technically simple with gratifying midterm results.

Aged↗

Management strategies for high-risk cardiac surgery: improving outcomes in patients with heart failure.

BACKGROUND: Surgical heart failure management is the fastest growing aspect of cardio-vascular surgery. Advances in cardiac surgical techniques have changed the number and types of operations permitted physicians and thus broadened the complexity of patients recommended for operation. METHODS: Surgeons, anesthesiologists and cardiologists face hemodynamic and patho-physiological challenges that can be optimally overcome only by modifying treatment strategies. Because many treatment standards are still evolving in this rapidly advancing field, a team of cardiovascular surgeons and anesthesiologists convened to share clinical experience and impressions and discuss practical issues related to high-risk patients undergoing heart surgery. RESULTS: Heart failure pathophysiology, surgical heart failure management, including mitral reconstruction and left ventricular remodeling, cardiopulmonary bypass weaning, inotropic support, transesophageal echocardiography and acute cardiovascular collapse after cardiac surgery are discussed. CONCLUSION: This article is intended to guide clinicians to improve patient care and outcomes in this special population by providing specific guidance on the appropriate use of inotropic and mechanical support in patients undergoing high-risk procedures using innovative techniques.

Cardiac Surgical Procedures↗