Search PubMed⌕ Search

Biomedical subjects

M C Huysmans

Publications and source records attributed to M C Huysmans.

28 records · Page 2Linked to original sources

[Diagnosis of primary caries. Current techniques and their consequences for treatment].

The decline in caries prevalence in The Netherlands has incited dentists to focus their attention to the detection of small carious lesions rather than large cavities. The diagnosis of primary caries is, however, still predominantly being accomplished by the traditional diagnostic methods, used in the high caries prevalence era. Today's appearance and behaviour of caries lesions have led to the situation that incipient enamel lesions, dentinal caries and cavities are frequently missed during routine recall examinations. There is increasing concern with the occurrence of large caries lesions underneath visually intact enamel. These problems have induced diagnostic research aimed at developing and evaluating new caries diagnostic methods and some of them are already used in general practice. Visual inspection and bitewing radiography, however, still constitute the most important methods in the diagnosis of primary caries. The results from these examinations are used to classify an individual's caries risk, to monitor the progression of existing caries lesions, and to aid preventive or restorative treatment decision making.

Dental Caries↗

Finite element analysis of quasistatic and fatigue failure of post and cores.

Finite element (FE) analysis of the mechanical behaviour of materials and structures facilitates the investigation of their internal stress distributions. However, the validity of the model is not always ascertained. In this study a three-dimensional (3D) FE model was developed, representing a laboratory set-up of direct post and core restored upper premolars. These restorations, using either composite or amalgam for core material, have been the subject of study in previous quasistatic and fatigue strength tests. The aim of this study was to validate the FE model for prefailure and failure modelling, by comparing the computational results with the laboratory observations and failure results. Two failure criteria were selected for investigation: Modified Von Mises and Drücker-Prager equivalent stress. Four model variations were carried out, representing different conditions at the core-tooth interface. Prefailure modelling was found to be adequate. The calculated failure results could only partly be fitted to the quasistatic tests. The best fit was effected with a model using partial bonding of the core, for the composite core. Fatigue failure was reproduced somewhat better by a model using no bonding at all, again to a higher degree for the composite core. Calculations of post stress using a model simulating increased core mobility supported an observation made previously (M. C. D. N. J. M. Huysmans et al., in press; Int. Endodont. J. XX, XXX-XXX), implying that a composite core raises the demands made on the post. The conclusion is made that validation of FE calculations is essential. A 3D model as presented here shows a satisfactory fit to fatigue data but not to quasistatic results.(ABSTRACT TRUNCATED AT 250 WORDS)

Alloys↗

Failure behaviour of fatigue-tested post and cores.

Evaluation of the long-term behaviour of restorations in clinical trials can be time-consuming. A partial alternative to the clinical trial can be found in mechanical fatigue testing. The aim of this study was to evaluate the failure behaviour of post and core restored teeth when subjected to cyclic mechanical loading and to compare it with quasistatic failure. Eighty seven premolar teeth were restored with a titanium alloy post and an amalgam or composite core. Five to 21 days after restoration, the specimens were subjected to cyclic loading (frequency 5 Hz), at an angle of 45 degrees to the long axis of the tooth. The load levels were 50, 60, 65 and 70% of mean quasistatic failure loads. The specimens were divided into three groups according to their survival time: short (S) (< 10(4) cycles), intermediate (I) (10(4) < or = life < 10(5) cycles) and long (L) (> or = 10(5) cycles). For both core materials failure behaviour changed after approximately 10(5) cycles, and the change was most marked for the composite group. Catastrophic fatigue failure consisted of core fracture in the amalgam group (three times) and of post fracture in the composite L group (four times). Three post fractures occurred at a site theoretically predisposed to fatigue failure. It was concluded that fatigue failure characteristics of post and core restorations may be very different from those of quasistatic failure. Therefore, in addition to quasistatic tests, fatigue tests are necessary, covering at least 10(5) load cycles.

Bicuspid↗

[The restoration of endodontically treated teeth. A literature study of the mechanical behavior of post-core restorations].

Rapid developments in dental health and science have resulted in an increasing number of teeth receiving post and core restoration. The dentist can choose from a wide range of restoration-modalities. Success or failure of these restorations largely depends on their ability to meet functional demands. This article presents a review of the literature on the mechanical behaviour of post-core restorations, as it is determined by functional forces, shape of the tooth and restoration and properties of the materials the construction encorporates. Some attention is drawn to the importance of failure characteristics in view of re-restoration possibilities. As a conclusion some guide-lines for the use of post and core restorations in the general dental practice are formulated.

Dental Restoration, Permanent↗

The Weibull distribution applied to post and core failure.

In this study, data on initial failure loads of direct post and core-restored premolar teeth were analyzed using the Weibull distribution. Restorations consisted of a prefabricated titanium alloy post, and an amalgam, composite or glass cermet core buildup in human upper premolar teeth. The specimens were subjected to compressive forces until failure at angles of 10, 45 and 90 degrees to their long axis. The two- and three-parameter Weibull distributions were compared for applicability to the failure load data. For estimation of the parameters of the two-parameter distribution: sigma 0 (reference stress) and m (Weibull modulus), linear regression was used. In this distribution, it is assumed that the third parameter, sigma u (cut-off stress), equals 0. The Maximum Likelihood (MLH) method was used to estimate all three parameters. It was found that the choice of distribution has a strong influence on the estimated values and that the three-parameter distribution is best fitted for the failure loads in this study. Comparisons were made between the failure probability curves as found by MLH estimation for the different core materials and loading angles. The results indicated that the influence of loading angle on the failure mechanism was stronger than that of core material.

Bicuspid↗

Failure characteristics of endodontically treated premolars restored with a post and direct restorative material.

Ninety-one extracted maxillary premolar teeth were restored with a prefabricated post and amalgam, composite resin or glass-cermet core. Each group was again divided into three groups of 9-13 teeth to be subjected to an increasing load in one of three standardized directions (10, 45 and 90 degrees to the long axis of the tooth). Failure load and characteristics of failure were recorded. The glass-cermet-restored teeth had a lower strength than the other groups for every load direction (Student's t-test: P less than 0.01). Amalgam and composite resin groups showed a significant difference only for the 10 degrees loading condition (Student's t-test: P less than 0.02). Teeth restored with amalgam cores displayed a higher mean failure load, in combination with a 46% occurrence of root fracture.

Analysis of Variance↗

Fatigue behavior of direct post-and-core-restored premolars.

Evaluation of long-term mechanical behavior of new types of restorations in clinical trials is time-consuming. A partial alternative can be found in experimental fatigue-testing, which simulates accelerated mechanical deterioration. The aim of this study was to determine the feasibility of using fatigue-testing of a complex dental restoration and to evaluate the mechanical fatigue behavior of premolar teeth restored with a titanium alloy post and an amalgam or composite core. Eighty-seven human upper premolar teeth were decoronated, embedded, and restored with a prefabricated post of 1 mm diameter. The teeth were randomly assigned to one of two groups corresponding with a core build-up of amalgam or chemically-cured core composite, respectively. Five to 21 days after restoration, the specimens were subjected to cyclic loading (frequency, 5 Hz), at an angle of 45 degrees to the long axis of the tooth. The boundary technique was used for determination of the mean fatigue strengths of the restorations at 10(4), 10(5), and 10(6) cycles, simulating up to 1-3 years of clinical functioning. Mean fatigue strength was expressed in percentage of initial strength: For 10(4), 10(5), and 10(6) cycles, the results were 66%, 58%, and 52%, respectively, for the amalgam and 62%, 62%, and 53% for the composite group. It is concluded that fatigue-testing of more complex systems is possible, if a suitable testing method is selected. The restorations showed a comparable strength reduction after 10(6) cycles of about 50% of their initial strength. The composite core build-up showed a behavior less predictable than that of the amalgam, which might be attributed to handling parameters.

Alloys↗

[Restoration of endodontically treated elements. A literature review on the mechanical behavior of post and core structures].

Rapid developments in dental health and science have resulted in an increasing number of teeth receiving post and core restoration. The dentist can choose from a wide range of restoration-modalities. Success or failure of these restorations largely depends on their ability to meet functional demands. This article presents a review of the literature on the mechanical behaviour of post-core restorations, as it is determined by functional forces, shape of the tooth and restoration and properties of the materials the construction incorporates. Some attention is drawn to the importance of failure characteristics in view of re-restoration possibilities. As a conclusion some guidelines for the use of post and core restorations in the general dental practice are formulated.

Bicuspid↗

Relationship between mineral distributions in dentine lesions and subsequent remineralization in vitro.

Though the mineral distribution of the dentine carious lesion varies largely from tooth to tooth and from patient to patient, there are two main distribution profiles that characterize natural carious lesions in dentine. These profiles include softened and subsurface lesion types. The mineral distribution relationship between the starting profile and the profile after remineralization is not known. In order to study the relational aspects, we have produced demineralized dentine samples in vitro with mineral profiles similar to those of typical natural carious lesions, and subsequently remineralized the samples in a remineralizing solution with various fluoride concentrations (0, 2 and 10 ppm F). The mineral distributions were obtained by using an improved microradiographic technique. In addition, the nature of deposited mineral was analyzed by diamond-coupled total internal reflectance spectroscopy. Definite relationship was observed between the original lesion mineral distribution and the mineral distributions following remineralization. The amount of mineral present in approximately the first 50 microm of the lesion influenced the overall mineral profile after remineralization, possibly through influencing ion transport. If the amount was high (> approximately 10 vol%), the deposited mineral was confined to the surface (0-50 microm). The original mineral at those depths acted like a nucleus of mineral regrowth when the amount of residual mineral was intermediate, and like a transport barrier when the surface layer was well mineralized. If a surface barrier was not present, mineral was deposited at deeper depths in the lesion. Fluoride effect on dentine remineralization was dependent on the original mineral content and its distribution in the lesion. Although a high concentration of fluoride was very effective in low-mineral lesions, it produced hyperremineralization on well-mineralized subsurface lesions so that it prevented effective remineralization especially in deeper lesions.

Acetic Acid↗

Caries detection methods: can they aid decision making for invasive sealant treatment?

The decision to place sealants is a difficult one, and it has been suggested that in a low risk population it may be efficient to wait until caries is detected in the fissure. An invasive sealant technique with fissure preparation may then be indicated. The diagnostic method used in the indication of such a procedure should accurately detect both dentine caries and sound fissures: high sensitivity for dentine caries (at D3 threshold) with high specificity for enamel caries (at D1 threshold). The aims of this study were to assess the diagnostic performance of selected diagnostic methods at normal cut-offs for traditional dentine caries detection and at reduced cut-offs in relation to the desired performance mentioned above, and to assess whether fissure opening allows for accurate visual detection of dentinal caries. Data were obtained from 230 occlusal sites of 101 extracted human molar teeth. Diagnostic methods used on the entire sample were: visual inspection, electrical conductance measurements and laser fluorescence measurements. The sample was then divided into two groups. Group 1 was subjected to visual inspection after application of a dye. Group 2 was subjected to visual inspection after fissure opening only, and after subsequent dye application. Validation was performed by histological investigation. The results with cut-offs normally used in dentine caries detection were roughly in accordance with the literature, except for laser fluorescence. The sensitivity of visual inspection for dentinal caries (D3) was 17% before and 70% after fissure opening. Using reduced cut-offs, a 100% sensitivity (D3) was achieved with 2 methods, but this also resulted in 63 or 87% false positive diagnoses of sound surfaces. Visual inspection and electrical methods both showed a moderate to high sensitivity (D3) with a higher than 50% specificity (D1). It was concluded that visual inspection and electrical methods at reduced cut-offs may aid the indication of invasive sealant treatment. The visual detection of dentinal caries is substantially increased, but not perfect after fissure opening.

Area Under Curve↗