Matching a computerized brain atlas to multimodal medical images.

A method for matching a digital brain anatomical atlas to multimodal medical images (MRI, PET, and SPET) was implemented. The digital atlas was derived from anatomical templates of the brain, cut according to the orbitomeatal orientation. The atlas consists of a set of contiguous slices schematically describing the brain as anatomical contours and of a set of regions of interest (ROIs) classifying the brain into functionally homogeneous areas. The matching procedure includes (a) an edge detection method for the extraction of anatomical contours and (b) a warping algorithm based on contour matching to fit the atlas to the individual brain anatomy, as described by MRI. Once the atlas is matched to MRI, the associated templates of ROI can be overlapped with functional PET/SPET studies, individually registered to MRI. The method was tested on MRI studies. The efficacy of the warping algorithm in overlapping atlas and MRI contours was assessed by calculating for each slice an index representing the extent of overlapping (I). Values of I in the range 0.8-0.9 were found (I = 1 complete overlapping). Local accuracy was also verified by comparing the position of correspondent anatomical ROI in the atlas and MRI images before and after warping. The atlas-matching procedure was applied to representative MRI/PET clinical images for an objective regional analysis of functional data.

Algorithms↗

Evaluation of pre- and post-reconstruction count-dependent Metz filters for brain PET studies.

In this study we evaluated pre- (PR-R) and post-reconstruction (PO-R) count-dependent Metz filters for PET brain studies in order to increase signal-to-noise ratio. A set of studies using a 3D Hoffman brain phantom was performed at various count levels, and a reference image set was created from extremely high count images. Several combinations of PR-R and PO-R filtering were considered to find the optimal means of processing, including: Hann filter alone; PR-R Metz filter without or with a PO-R low pass filter; and PO-R Metz filter without or with a PR-R low pass filter. A formula was established to correlate the optimal PO-R Metz filter order with the net counts. Resolution [full width at half-maximum (FWHM) and fill width at tenth maximum (FWTM)], normalized residual mean square differences (NRMSD) between the ideal and the processed images, noise reduction and contrast were used as parameters for the evaluation of the different filter combinations. Resolution is decreased by all filter combinations that can effectively control noise; however, FWTM increases less than FWHM. NRMSD indicates that the use of Hann and (optimal) PO-R Metz filter is the most powerful combination from among those tested. A close correlation (r = 0.969) was found between the net counts and the optimal order of the PO-R Metz filter. At the count levels of clinical studies the PO-R Metz filter was found to control noise much more effectively and enhance the contrast when compared to the routinely used Hann filter alone, and produced images of better quality.

Biophysical Phenomena↗

Single-photon emission tomographic quantification in spherical objects: effects of object size and background.

A method was set up for single-photon emission tomographic (SPET) quantification of radioactivity concentration in small anatomical structures. The method is based on the theoretical model proposed by Kessler et al. (J. Comput Assist Tomogr 1984; 8: 514-522) describing the effects of spatial resolution (partial volume effect and spillover) on the quantification of radioactivity concentration in small spherical objects. The model was validated here in SPET, by phantom experimental measurements, in relation to object size and source/background contrast. Good agreement was found between model-predicted and SPET-measured radioactivity concentration ratios in hot spots in hot background experiments. Accuracy of the method was assessed for comparison of model-corrected and true radioactivity concentration ratios and was found to be within 8.5% over the full range of object size (9.4-36.5 mm). The good agreement found indicates that the model can be used to correct for partial volume effect and spillover in specific clinical situations, when the anatomical structure under study can be approximated by a sphere of known size (e.g. neuroreceptor and tumour studies). The method was applied to a representative SPET monoclonal antibody patient study for the quantification of radioactivity concentration in ocular melanoma.

Eye Neoplasms↗

A procedure for wall detection in [18F]FDG positron emission tomography heart studies.

Quantitative positron emission tomography (PET) heart studies require the accurate localization of regions of interest (ROIs) on the myocardial wall (MW) and left ventricle (LV). The procedure is often inaccurate, especially when there is low tracer uptake. We implemented a data processing technique to improve the accuracy of the localization of ROIs on the MW and LV in fluorine-18 labelled deoxyglucose ([18F]FDG) PET heart studies. This technique combines transmission data, acquired before tracer administration and used for attenuation correction, and dynamic emission data (DY), acquired to obtain myocardial time-activity curves and used to calculate regional myocardial glucose utilization, to generate a new set of "transmission" images (TRDY) with enhanced contrast between MW and LV. These new transmission images identify the extravascular myocardial tissue and can be used for ROI placement. Validation of the method was performed in 25 patients, studied after an oral glucose load, by drawing irregular ROIs on three transaxial slices outlining the septum and anterior-apical and lateral wall on the last frame of the DY images (steady state) and then on the TRDY images. Two kinds of analysis were performed on a total of 225 myocardial segments: (1) mean counts per pixel in the DY images from ROIs independently drawn on DY and TRDY images were compared; (2) TRDY ROIs were copied onto DY images and repositioned in the event of mismatch between ROIs and myocardial tissue edge. Mean counts per pixel in the DY images from the original and the repositioned TRDY ROIs were compared. An excellent correlation was found in both cases (using TRDY and DY ROIs: y=0.908 x+0.068, r=0.97; using TRDY ROIs alone: y=0.975 x+0.006, r=0.99). This technique can be used for clinical applications in physiological and pathological conditions in which the myocardial [18F]FDG uptake is reduced or minimal, including diabetes and myocardial infarction.

Calibration↗

Registration of multi-modal biomedical images of the heart.

Integration of multi-modal biomedical images of the heart (PET, SPET, MRI, Echocardiography) is a diagnostic procedure of increasing interest. Different registration techniques can be used to spatially correlate two independent tomographic scans of the same patient, each technique presenting relative merits and limitations. Integration of cardiac with respect to neurological images is difficult, because the heart is a non-rigid and moving organ. The experiences of this approach of integrated diagnosis are thus limited to date. However, registration of PET, SPET, MRI, Echocardiographic images has been described with accuracy considered acceptable for clinical applications. Registration techniques for the integration of multi-modal biomedical images of the heart, the clinical applications of cardiac image fusion and the experiences reported in the literature are presented in this paper.

Diagnostic Imaging↗

An elastic computerized brain atlas for the analysis of clinical PET/SPET data.

An elastic computerized brain atlas was developed for the analysis of positron emission tomography/single-photon emission tomography (PET/SPET) data. It consists of a set of digital anatomical contours and a template of regions of interest, schematically describing the brain, derived from a currently used anatomical/functional brain atlas. A warping algorithm, matching equivalent contours, was implemented to elastically fit the atlas to individual brain images. The elastic computerized brain atlas was applied to representative magnetic resonance imaging (MRI)-PET/SPET studies, MRI providing the anatomical information used by the matching procedure. The atlas is suited for clinical use in a nuclear medicine environment.

Brain↗

Spatial registration of echocardiographic and positron emission tomographic heart studies.

A method has been developed to match corresponding heart regions from functional echocardiographic (Echo) and metabolic fluorine-18-fluoro-2-deoxy-D-glucose ([18F]FDG) positron emission tomography (PET) studies in individual patients. Echo and PET images are spatially correlated by determining homologous anatomical landmarks (the two papillary muscles and the inferior junction of the right ventricle), identifiable in images obtained by both acquisition modalities. Echo-PET image registration is first performed in the plane identified by the three landmarks, using a rigid rotate-translate scale model. The registration parameters are then used to transform the whole PET volume. This allows a consistent Echo-PET regional analysis, according to a segmental subdivision of the heart. The technique was tested on patients. The overlay of Echo and PET registered images proved the reliability of realignment of the three markers and a good spatial correlation of myocardial walls. This approach to image registration could be applied to other acquisition modalities (such as magnetic resonance imaging and single-photon emission tomography), provided that the three anatomical landmarks are visualized.

Deoxyglucose↗

Application of a surface matching image registration technique to the correlation of cardiac studies in positron emission tomography (PET) by transmission images.

The aim of this work is to assess the accuracy of a surface matching registration (SMR) technique for the correlation of cardiac studies in positron emission tomography (PET). Registration parameters were estimated by matching corresponding body surfaces, extracted from transmission studies, aligned to the PET emission images to be correlated. The accuracy of the SMR technique in this specific application was assessed by computer simulations, phantom experiments and on clinical PET data. Registration accuracy was evaluated in relation to the body surfaces (external, internal and the combination of the two) used by the SMR method. Better results were found when matching shaped and irregular surfaces such as internal lung contours. The robustness of the method was verified for different counting statistics recorded in transmission images. A clinical validation of the SMR method was performed on fluorine-18-deoxyglucose PET cardiac studies.

Computer Simulation↗

Performance comparison of a state-of-the-art neuro-SPET scanner and a dedicated neuro-PET scanner.

The physical performances of two current state-of-the-art scanners dedicated to functional imaging of the brain, one a single-photon emission tomography (SPET) scanner and the other a positron emission tomography (PET) scanner, have been compared under identical conditions. The aim of the study was to compare the capabilities of the devices under conditions resembling the routine clinical environment, as well as to consider other issues such as radiation burden for some common investigations. Both systems have slightly less than 11-cm axial fields of view. The PET system can be operated in a septa-less (3D) mode as well as conventionally with septa (2D). The spatial resolution of both devices was less than 8 mm in all dimensions in scattering media. On average, the PET scanner's resolution was approximately 10%-15% better than the SPET system. Energy resolution on the SPET system was superior due the scintillator used [NaI(Tl)]. Sensitivity in air with a line source on the PET system was found to be approximately 150 times greater in 3D and approximately 25 times greater in 2D than with the SPET system. A normal subject was studied on each system in an attempt to obtain the highest quality data possible for a subjective comparison. It is clear that, while PET retains the advantages of more desirable radiopharmaceuticals and higher sensitivity, the quality obtainable from SPET devices has improved markedly. SPET may prove as useful for many clinical investigations.

Brain↗

A hybrid method of attenuation correction for positron emission tomography brain studies.

A hybrid method for attenuation correction (HAC) in positron emission tomography (PET) brain studies is proposed. The technique requires the acquisition of two short (1 min) transmission scans immediately before or after the emission study, with the patient and the head fixation system in place and after removing the patient from the scanner with the head fixation system alone. The method combines a uniform map of attenuation coefficients for the patient's head with measured attenuation coefficients for the head fixation system to generate a hybrid attenuation map. The HAC method was calibrated on 30 PET cerebral studies for comparison with the conventional measured attenuation correction method by ROI analysis. Average differences of less than 3% were found for cortical and subcortical regions. The HAC technique is particularly suitable in a PET clinical environment, allowing a reduction of the total study time, greater comfort for patients and an increase in patient throughput.

Brain↗

A bioimaging integration system implemented for neurological applications.

A system aimed at the management and fusion of multimodal biomedical images, including X-ray computed tomography, magnetic resonance imaging, positron emission tomography, and single photon emission computed tomography, has been implemented for neurological applications. This bioimaging integration system (BIS) consists of a network for image transmission from acquisition machines to dedicated image processing workstations, a software library for image standardization, and an image registration technique to project multimodal volumetric images into a common reference space. The registration procedure was evaluated in MRI/PET correlation studies, in which misalignment errors of 2.6 mm in the xy transaxial plane and 3.4 mm along the z axis were found. BIS has been validated for the anatomical-functional correlation analysis of MRI and PET images in neurological research protocols and clinical studies.

Brain Diseases↗

High-resolution technetium-99m-HMPAO SPECT in patients with probable Alzheimer's disease: comparison with fluorine-18-FDG PET.

UNLABELLED: SPECT studies of regional cerebral perfusion with a high-resolution system were compared to PET studies of regional cerebral glucose utilization (rCMRglc) in 21 patients with probable Alzheimer's disease (AD). Ten normal subjects were also evaluated with SPECT and 10 with PET. METHODS: rCMRglc (for PET) and counts (for SPECT) in the associative cortices were normalized to the average rCMRglc, and counts in the calcarine cortex and basal ganglia were considered as a "reference area" to obtain a ratio. The ratio differences between patients and controls were tested with ANOVA performed separately for PET and SPECT. RESULTS: The difference between probable AD patients and controls was significant for both PET (p < 0.00001) and SPECT (p < 0.005); this difference was significant for the frontal, temporal and parietal cortices (p < 0.0001) for PET, and for the temporal (p < 0.005) and parietal (p < 0.001) cortices for SPECT. Temporo-parietal defects were detected in all subjects with PET and in 90% with SPECT. CONCLUSION: PET and SPECT are able to detect characteristic temporo-parietal abnormalities in probable AD. However, the presence of abnormalities in other associative areas is better evaluated with PET.

Adult↗

Time dependence of residual tissue viability after myocardial infarction assessed by [18F]fluorodeoxyglucose and positron emission tomography.

Areas of myocardial infarction may retain glycolytic activity and this finding is indicative of tissue viability and predictive of functional recovery after revascularization. In order to assess the relation between the time elapsed from the occurrence of acute myocardial infarction and persistence of myocardial metabolic activity in the infarcted tissue, we prospectively studied 65 patients with previous myocardial infarction diagnosed clinically and by electrocardiographic (Q wave) and enzymatic criteria. All patients underwent coronary angiography and contrast left ventriculography, evaluation of regional myocardial glucose metabolism (in the fasting state) by positron emission tomography (PET) with 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG), and assessment of myocardial perfusion by single photon emission computed tomography (SPECT) with technetium-99m methoxyisobutyl isonitrile (99mTc-MIBI). Based on the regional metabolic and perfusion findings, patients were divided into 2 groups, depending on the absence (group 1, 26 patients) or presence (group 2, 39 patients) of [18F]FDG uptake in the underperfused regions. Areas of underperfusion at rest, consistent with the clinically identified myocardial infarction site, were observed in all patients. Severity of coronary artery disease, presence of collaterals, number of hypocontractile segments, and wall motion score did not differ significantly in the 2 groups. The time elapsed from the infarction was significantly greater (1,860 +/- 1,333 days) in group 1 than in group 2 (92 +/- 115 days; p < 0.0001). Exercise caused an increase in severity and/or extent of resting perfusion abnormalities in a greater proportion of patients of group 1 (53% vs 23%).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Activation of precentral and mesial motor areas during the execution of elementary proximal and distal arm movements: a PET study.

Regional cerebral blood flow was measured using positron emission tomography (PET) in normal subjects while performing simple aimless proximal and distal arm movements. The aim of the experiment was to compare the somatotopic organization of precentral and mesial (the so called supplementary motor area, SMA) motor cortices and to evaluate whether in man, as in the monkey, the rostral and caudal sectors of SMA are functionally different. The results showed that proximal and distal arm movements are to a large extent segregated in the precentral motor cortex, but not in the SMA. They also showed that the SMA is made of at least two functional sectors. Only the caudal one is activated during simple aimless movements.

Adult↗

A procedure for patient repositioning and compensation for misalignment between transmission and emission data in PET heart studies.

A procedure for patient repositioning and compensation for misalignment between transmission and emission data in positron emission tomography (PET) heart studies has been developed. Following the transmission scan (TR1), patients are moved from the scanner bed for the administration of the tracer, and repositioned when ready for the emission scan (EM1). A short postinjection transmission scan (TR2) is performed at the end of the EM1 study. TR1 and TR2 images are compared to recognize misalignment between transmission and emission studies. TR1 sinograms are compensated for misalignment to allow for a proper attenuation correction. The procedure has been tested on phantom and [18F]FDG PET heart studies. Misalignments down to 2.5 mm translation and 1 degree rotation in the transaxial plane and 4 mm in the axial direction can be recognized and compensated for. The procedure is suitable for clinical purposes, allowing reduction of patient time on the scanner bed, increased patient comfort and significant increase of patient throughput.

Deoxyglucose↗

Errors introduced by tissue heterogeneity in estimation of local cerebral glucose utilization with current kinetic models of the [18F]fluorodeoxyglucose method.

The effects of tissue heterogeneity on the estimation of regional cerebral glucose utilization (rCMRglc) in normal humans with [18F]2-fluoro-2-deoxy-D-glucose ([18F]FDG) and positron emission tomography (PET) were compared with respect to the various kinetic models of the [18F]FDG method. The kinetic models were conventional homogeneous tissue models of the [18F]FDG method, with (4K Model) and without (3K Model) a rate constant to account for an apparent loss of [18F]2-fluoro-2-deoxy-D-glucose-6-phosphate ([18F]FDG-6-P), and a tissue heterogeneity model (TH Model). When either of the kinetic models designed for homogeneous tissues was applied to heterogeneous tissues, estimates of the rate constant for efflux of [18F]FDG from the tissue (k2*) and of the rate constant for phosphorylation of [18F]FDG (k3*) decreased as the duration of the experimental period was increased. When the 4K Model was used, estimates of the rate constant for the apparent dephosphorylation of [18F]FDG-6-P (k4*) were significantly greater than zero and fell with increasing duration of the experimental period. Although the TH Model included no term to describe an apparent dephosphorylation of [18F]FDG-6-P, the fit of the TH Model to the time course of total tissue radioactivity was at least as good as and often better than the fit of the 4K Model in the 120-min period following the pulse of [18F]FDG. Hence, the high estimates of k4* found in PET studies of less than or equal to 120 min can be explained as the consequence of measuring radioactivity in a heterogeneous tissue and applying a model designed for a homogeneous tissue; there remains no evidence of significant dephosphorylation of [18F]FDG-6-P in this time period. Furthermore, use of the 4K Model led to an overestimation of rCMRglc; whole-brain glucose utilization calculated with the 4K Model was greater than 20% higher than values usually obtained in normal humans by the model-independent Kety-Schmidt technique. rCMRglc was accurately estimated by the TH Model and, in experimental periods sufficiently long to minimize the effects of tissue heterogeneity, also by the original 3K Model of the deoxyglucose method.

Adult↗

Metabolic impairment in human amnesia: a PET study of memory networks.

Human amnesia is a clinical syndrome exhibiting the failure to recall past events and to learn new information. Its "pure" form, characterized by a selective impairment of long-term memory without any disorder of general intelligence or other cognitive functions, has been associated with lesions localized within Papez's circuit and some connected areas. Thus, amnesia could be due to a functional disconnection between components of this or other neural structures involved in long-term learning and retention. To test this hypothesis, we measured regional cerebral metabolism with 2-[18F]fluoro-2-deoxy-D-glucose ([18F]FDG) and positron emission tomography (PET) in 11 patients with "pure" amnesia. A significant bilateral reduction in metabolism in a number of interconnected cerebral regions (hippocampal formation, thalamus, cingulate gyrus, and frontal basal cortex) was found in the amnesic patients in comparison with normal controls. The metabolic impairment did not correspond to alterations in structural anatomy as assessed by magnetic resonance imaging (MRI). These results are the first in vivo evidence for the role of a functional network as a basis of human memory.

Adult↗

Physical performance of a positron tomograph for brain imaging with retractable septa.

Performance characteristics of a new design of positron tomograph with automatically retractable septa for brain imaging have been studied. The device, consisting of block BGO detectors (8 x 8 elements per block), has a ring diameter of 76 cm and an axial FOV of 106.5 mm. The in-plane resolution is on average 5.8 mm and 5.0 mm (FWHM) for stationary and wobble sampling, respectively, over the central 18 cm of the transaxial FOV. Its unique feature is the capability of data acquisition both in the 'conventional' 2D mode (with septa) or 3D mode (septa retracted) where coincidences between any of the 16 detector rings are acquired. When scattered events are subtracted, the efficiency for a 20 cm diameter uniform cylinder increases overall by a factor of 4.8 between 2D (septa extended) and 3D modes. For a 20 cm phantom the trues/singles ratio is higher for 3D than for 2D but for a given unscattered trues rate, the randoms rate in 3D is higher. At 380 keV the scatter fraction within a 20 cm cylinder is 10% (septa extended) and 36% (retracted). In spite of the increase in scatter when septa are retracted, the increased efficiency in the 3D mode of acquisition yields distinct advantages, particularly in the many studies where tracer concentration is low and consequently where dead time and random rates are less important.

Brain↗