Search PubMed⌕ Search

Biomedical subjects

M C Chan

Publications and source records attributed to M C Chan.

At least 37 records · Page 2Linked to original sources

Unusual site of spontaneous first-rib fracture: case report.

Spontaneous fractures of the first rib are uncommon and are usually thought to be associated with a malignant process. However, fatigue fractures of the first rib are being encountered increasingly in association with various physical activities. Typically, the fractures occur at the subclavian groove, but in the 48-year-old woman described in this report the fracture was unexpectedly situated in the posterior portion of the rib and was the result of snow shovelling, which was a new activity for the patient.

Female↗

[Simultaneous cholecystectomy with colon surgery].

Both colorectal pathology and cholecystopathy are common disorders, especially among the elderly. Postoperative cholecystitis was well known to be associated with high morbidity and mortality. The presence of gall bladder pathology has also been reported to precipitate acute cholecystitis. In addition, these patients with gall bladder pathology may eventually need a cholecystectomy because of complications. In the above cases, some authors have suggested a simultaneous cholecystectomy at the time of colon surgery. In past 4 years, a series of 28 cases with concomitant cholecystectomy and colectomy were reviewed. The male to female ratio was 11:17, and their age ranged from 41 to 83 years old (mean age 61). The main colonic pathology was adenocarcinoma of colon and rectum (26/28). All gall bladder pathologies were diagnosed preoperatively by abdominal ultrasound, and gall stones were present in 25 of 28 cases. There were no intraoperative complications and no operative mortalities. Our data suggested that a cholecystectomy can be performed safely at the time of colon surgery, if the patient's condition is stable and contamination from colon surgery is minimal.

Adult↗

Hazards of angioscopic examination: documentation of damage to the arterial intima.

The fiberoptic scope is increasingly used in the coronary and peripheral arteries to quantitate the degree and type of arterial obstructive disease and to inspect the results of procedures such as bypass grafting and laser irradiation of obstructive lesions. Since little is known about this instrument's potential complications, we passed a variety of fiberoptic scopes (1.8 to 3.6 mm outer diameter) in fresh postmortem pig coronary arteries and live monkey and canine peripheral arteries, and observed the intraluminal anatomy through the angioscope. No perforations were created, but ridges rising from the vascular luminal surface, avulsion of the endothelial lining, and small flaps attached at one end to the vessel wall were observed. Histologically, subintimal and medial tears were evident. Inserting large diameter scopes or making frequent passes (10 to 100) in coronary arteries increased intravascular injury. The use of small diameter flexible scopes or infrequent passes (less than 10) in the larger iliac and femoral arteries of live monkeys and dogs resulted in a lower frequency of myointimal sloughing or flap formation. Current fiberoptic scopes are not ideal angioscopes; they have a rigid tip, cannot be steered adequately, and are relatively stiff, resulting in a high probability of intraluminal injury, especially when used in small tortuous arteries. To decrease the risk of such injury, we recommend gentle manipulations while passing the scope and use of the smallest diameter scope possible. We further suggest limited use of the fiberscope, or at least limiting the number of passes in small vessels such as coronary arteries.

Animals↗

Antihypertensive therapy and the concept of total cardiovascular protection.

Drug-induced reduction of elevated blood pressure decreases cardiovascular mortality and morbidity in patients with moderate and severe hypertension. Furthermore, antihypertensive drug studies in mild hypertensive subjects (diastolic blood pressure 90 to 104 mm Hg) have shown protection against stroke, left ventricular hypertrophy, congestive heart failure and progression of renal damage, as well as improved patient longevity. The Hypertension Detection and Follow-up Program trial, recently carried out in the U.S., documented reduced coronary artery disease events (fatal and nonfatal) in special drug-treated patients with mild hypertension. From the standpoint of practical management and considering the ubiquity of essential hypertension, a modified stepped-care regimen advocating initial drug therapy with a beta blocker and addition of low-dose thiazide diuretic when necessary constitutes a judicious approach for widespread application. Although there are 8 orally active beta blockers currently approved in the U.S. for clinical use in systemic hypertension, only acebutolol possesses all of the salutary pharmacologic properties of cardioselectivity, intrinsic sympathomimetic activity and hydrophilicity, thereby making this compound an effective and safe beta-blocking agent for first-order management of a broad segment of the hypertensive population.

Acebutolol↗

Effects of simultaneous viewing and vaporization of plaques using the steerable, laser-heated metal cap in the atherosclerotic monkey model.

A steerable, fiberoptic catheter coupled to a laser light guide tipped with a metal cap was used. Four monkeys fed an atherogenic diet for 7-8 years were angiographed and were found to have extensive mural plaque in the iliac arteries. Plaque sites in these monkeys were vaporized using the laser-heated metal cap. Energies of 1.5-9 Joules were employed. Application of the energy was tangential of perpendicular to the plaque. Lased sites were examined histologically at 24 hr or at 3 months after treatment. No effect was seen at 1.5 Joules. Three to six Joules tangentially produced a superficial lesion that extended into the tunica intima. Six Joules perpendicularly produced a burn into the tunica adventitia, with damage to the vasavasorum. Nine Joules tangentially produced a burn into the tunica media. Three months after treatment, this lased site showed no stenosis or aneurysm formation.

Animals↗

Differential photoabsorption using argon laser radiation on atherosclerotic plaque in non-hemolyzed and hemolyzed blood.

Since argon laser radiation (488 to 514 nm) can vaporize human atherosclerotic plaque, we determined whether different blood media--hemolyzed versus non-hemolyzed blood--can alter photoabsorption of atherosclerotic plaque. Forty cadaveric aortic fibrous plaque samples were fitted onto small vials containing 0.02 ml of either non-hemolyzed blood or hemolyzed blood over the surface of the plaque. The distal end of a 400-mu core diameter quartz fiber was directed onto the surface of the plaque and the proximal end of the fiber was connected to an argon laser. The vaporized area and depth of plaque penetration were measured and the estimated volume of crater formation was derived. Following 2.5, 5, 10 and 20 J of laser energies, vaporized volumes were 0.12, 0.72, 0.97 and 4.09 mm3, respectively, for hemolyzed blood and were 0 (p less than 0.01), 0 (p less than 0.01), 0.92 (NS) and 4.39 mm3 (NS), respectively, for non-hemolyzed blood. Laser radiation destroys red blood cells; the higher the energies, the greater the hemolysis. Thus, different blood media such as hemolyzed and non-hemolyzed blood can alter photoabsorption of atherosclerotic plaque. Low level argon laser absorption upon plaque can occur under hemolyzed blood but not under non-hemolyzed blood. Since higher levels of argon laser energies cause greater lysis of red blood cells, comparable degrees of plaque ablation are observed under either blood medium.

Arteriosclerosis↗

Correlation of coronary angioscopic to angiographic findings in coronary artery disease.

An Olympus ultrathin fiberscope, 1.8 mm outer diameter, was inserted intraluminally into 11 stenoses of the left anterior descending and circumflex coronary arteries in 8 patients at coronary bypass surgery. Intraluminal views were obtained by coupling the angioscope to a color video camera and videotape recorder, and compared with preoperative coronary angiographic findings in right and left anterior oblique views. Atherosclerotic plaque was observed as yellow-white mass attached onto the luminal lining, which may be large enough to virtually obliterate the vascular lumen. Angioscopy provided a topographic view and cross-sectional picture of stenosis not observed by angiography. Single-plane angioscopic cross-sectional stenotic lumens correlated well (r = 0.90, p less than 0.001) with calculated angiographic luminal narrowings. However, with subtotal obstruction, lesion length must be assessed angiographically. Coronary angioscopy can be a useful adjunct to angiography by providing the added dimension of the true cross-sectional view of obstruction.

Coronary Angiography↗

Comparison of intravenous mexiletine and lidocaine for the treatment of ventricular arrhythmias.

The efficacy and safety of intravenous loading of mexiletine was compared to lidocaine in patients with ventricular premature depolarizations (VPDs). Seventeen men and five women, average age 63 years, completed this randomized parallel study. Twelve patients received mexiletine intravenously at (5 to 10 mg/min) until greater than or equal to 95% VPD suppression was achieved or a total of 450 mg of drug was given. The average loading dose of mexiletine was 4.4 mg/kg, at an infusion rate of 0.1 mg/kg/min. Ten patients received lidocaine (1 mg/kg) given over 3 minutes, with a second similar bolus given if after 10 minutes greater than or equal to 95% VPD suppression was not achieved. Total VPDs were determined for the 60 minutes before drug administration, during drug infusion, and 60 minutes thereafter. Eleven of 12 (92%) patients receiving mexiletine were full responders (greater than or equal to 95% suppression) and one was a partial responder (greater than or equal to 75% greater than or equal to 95% suppression). Five of 10 lidocaine patients (50%) were full responders, three (30%) were partial responders, and two failed to respond. At peak suppression, mexiletine reduced mean VPD from 37 +/- 33/5 minutes (mean +/- S.D.) to 0.8 +/- 0.9/5 minutes (p less than 0.01) and lidocaine decreased mean VPDs from 28 +/- 47/5 minutes to 4.7 +/- 2.2/5 minutes (p less than 0.01). Mexiletine resulted in greater suppression of VPDs than lidocaine in terms of mean percent reduction (96% vs 68%, p less than 0.01). All lidocaine patients had therapeutic plasma levels (range 1.6 to 3.5 micrograms/ml).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗