Search PubMed⌕ Search

Biomedical subjects

M Brunner

Publications and source records attributed to M Brunner.

At least 109 records · Page 6Linked to original sources

Prediction of ovarian hyperstimulation syndrome by ultrasound volumetric assessment [corrected] of baseline ovarian volume prior to stimulation.

The aim of the study was to find out whether the estimation of the baseline ovarian volume prior to stimulation would be a suitable predictor for the risk of ovarian hyperstimulation syndrome (OHSS). A total of 101 patients underwent in-vitro fertilization (IVF) and embryo transfer. They had a 3-D volumetric assessment of the ovaries and body weight estimations on the first day of hormonal stimulation. A second measurement was performed on the day of ovulation induction with human chorionic gonadotrophin (HCG) together with an oestradiol 17 beta estimation in serum. During the IVF programme 15 women developed OHSS and 86 did not. There was a significant correlation between the baseline ovarian volume and subsequent occurrence of OHSS (P = 0.03). Other significant relationships were found between the occurrence of OHSS and the number of follicles (P = 0.002), the number of oocytes retrieved (P = 0.0001) and the length of the cycle (P = 0.0001). The body weight before and after the stimulation was significantly lower in the group of women who did develop the syndrome (P = 0.011 resp. 0.03). The oestradiol 17 beta concentration on the day of HCG administration in the serum of the patients who had OHSS was significantly higher (P = 0.0001). In conclusion, volumetry of the ovaries could help to detect patients at risk and prevent the occurrence of OHSS by early adjustment of the hormonal dosage. Recent advances in ultrasound technology (3-D ultrasound) enable quick and highly accurate volumetric assessments. Furthermore, our study confirms previous observations that low body weight and long cycles seem to be additional risk factors for the development of OHSS.

Adult↗

Accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients.

OBJECTIVE: To evaluate the accuracy and reliability of noninvasive continuous finger blood pressure measurement in critically ill patients. DESIGN: Prospective data collection. SETTING: Emergency department in a 2,000-bed hospital. PATIENTS: Thirty-nine patients admitted to the emergency department requiring invasive arterial blood pressure monitoring were enrolled to the study protocol. INTERVENTIONS: Continuous noninvasive blood pressure measurement was performed on the middle phalanx of the second and third finger, using a test instrument which provides continuous arterial waveform display with the use of a finger cuff. Invasive mean arterial blood pressure measurement was done by cannulation of the radial artery and direct transduction of the systemic arterial pressure waveform. MEASUREMENTS AND MAIN RESULTS: Three thousand one hundred eighteen pairs of simultaneous finger cuff and intra-arterial blood pressure measurements were collected in 1-min intervals from 39 patients over a total of 51.8 hrs. The overall discrepancy between both measurements was 0.10 mm Hg. The standard deviation of the differences was +/- 5.02 mm Hg. The mean bias in patients treated with catecholamines was 0.01 mm Hg and was not different from the bias observed in patients without catecholamines (mean bias: 0.23 mm Hg; p > .22). Whereas 95% of all comparisons between finger cuff and intra-arterial measurement had a discrepancy < or = +/- 10 mm Hg, 4.7% had a discrepancy between +/- 10.1 to 15 mm Hg and 0.3% exhibited a discrepancy > +/- 15 mm Hg. In 29 (74%) patients, the duration of errors > 10 mm Hg was < or = 1 min. In seven (18%) patients, the duration of errors > 10 mm Hg was between 2 to 3 mins and in three (8%) patients, the errors lasted for > 3 mins. CONCLUSIONS: Our data provide a guide to the accuracy and reliability of noninvasive finger blood pressure measurements in critically ill patients. Although most test instrument measurements were reliable, in 8% of all patients large discrepancies (> 10 mm Hg) between both measurements with a duration of > 3 mins were noted. Concerning the considerable risk for arterial cannulation, our preliminary data demonstrate that the test instrument (PORTAPRES, TNO Biomedical Instrumentation Research Unit; The Netherlands) is an advance in noninvasive monitoring of critically ill patients and may be useful in most emergency clinical settings.

Adult↗

Adenosine in treating cardiac arrhythmias.

1. Adenosine is an endogenous nucleoside which causes a brief blockade of the AV nodal conduction pathway following intravenous administration. 2. Such a brief AV block can be used therapeutically for reliable termination of AV nodal re-entry tachycardia and WPW re-entry tachycardia. It can also be used for demasking atrial activity in rapid suspected supraventricular tachycardia with a broad QRS complex or a Delta wave, not present during sinus rhythm with normal AV node conduction, indicating the presence of a hidden WPW syndrome. 3. Side effects after adenosine application are frequent, but very transient rarely serious (1-3% of cases, e.g. status asthmaticus, ventricular fibrillation) and therefore require a certain degree of experience with this drug on the part of the treating physician.

Adenosine↗

Cardiorespiratory response to free suspension simulating the situation between fall and rescue in a rock climbing accident.

Many factors contribute to the risk of late death after successful rescue in a rock climbing accident. One factor may be hemodynamic and respiratory compromise by free suspension in a rope between fall and rescue. The risk probably results from using a chest harness alone or the combination of a chest harness and a sit harness. No trials on the acute cardiorespiratory response to free suspension in rock climbing have been reported so far. The effect of 3 min free suspension in a chest harness or in a sit harness on cardiopulmonary parameters was investigated in a randomized, cross-over trial in six healthy volunteers in a simulated rock climbing accident. Measurements were performed before and during the suspension at an altitude of 171 m. No statistical change in cardiopulmonary parameters was observed after free suspension in the sit harness. After free suspension in the chest harness, mean forced vital capacity decreased by 34.3% and mean forced expiratory volume decreased by 30.6%. No statistical change of arterial oxygen saturation occurred and mean end-tidal carbon dioxide increased by 11.5%. Mean heart rate decreased by 11.7%, mean systolic blood pressure decreased by 27.6%, mean diastolic blood pressure decreased by 13.1%, and mean cardiac output decreased by 36.4%. The p value for all reported changes was <0.05. We conclude that free suspension in a chest harness leads to a dramatic impairment of hemodynamics and respiration. This may contribute to the risk of a fatal outcome if rescue is not timely.

Accidental Falls↗

Clinical evaluation of different doses of intravenous enalaprilat in patients with hypertensive crises.

BACKGROUND: The appropriate dose of intravenous enalaprilat to be used in the treatment of hypertensive crisis is controversial. There has been no comparative study of the efficacy and safety of different dosages of enalaprilat in hypertensive patients. METHODS: Sixty-five consecutive patients with hypertensive urgencies (systolic blood pressure > 210 mm Hg and/or diastolic blood pressure > 110 mm Hg) or emergencies (diastolic blood pressure > 100 mm Hg and evidence of end-organ damage, ie, angina pectoris, hypertensive encephalopathy, or congestive heart failure) admitted to an emergency department from January 1, 1994, to September 30, 1994, were identified. The patients were randomized to receive different doses of enalaprilat (0.625, 1.25, 2.5, and 5 mg). Response to treatment was defined as a stable reduction of systolic blood pressure to below 180 mm Hg and diastolic blood pressure to below 95 mm Hg within 45 minutes after the start of treatment and relief of symptoms in patients with hypertensive emergencies. RESULTS: In 41 (63%) of 65 patients, the treatment goal was reached. Twenty-four patients (37%) failed to achieve the goal of treatment within 45 minutes after administration of enalaprilat. The response rates in the 0.625-mg, 1.25-mg, 2.5-mg, and 5-mg groups were 67%, 65%, 59%, and 62%, respectively. The proportion of patients initially randomized who responded to treatment was not different between any of the four groups of enalaprilat doses. There were no significant differences according to enalaprilat dose with respect to changes in systolic, diastolic, and mean arterial blood pressure. No severe side effects were observed. CONCLUSION: Enalaprilat is a safe antihypertensive drug with moderate efficacy in the treatment of hypertensive crisis. As doses above 0.625 mg alter neither response rates nor the magnitude of blood pressure reduction, we recommend 0.625 mg as the initial dose in the treatment of hypertensive crisis.

Aged↗

The MIM complex mediates preprotein translocation across the mitochondrial inner membrane and couples it to the mt-Hsp70/ATP driving system.

We have identified a complex in mitochondria that functions as a part of the preprotein import machinery of the inner membrane (MIM complex). Two known components, MIM23 and MIM17, and two novel components, MIM33 and MIM14, were found as constituents of this complex. In the presence of a translocating chain, the outer membrane import machinery (MOM complex) and the MIM complex form translocation contact sites. On the matrix side, the MIM complex is associated with the mt-Hsp70-MIM44 system. We propose a structure of the import machinery in which the MIM complex constitutes a proteinaceous channel that accepts preproteins from the MOM complex, facilitates their reversible transmembrane movement, and mediates unidirectional transport by linkage to the ATP-dependent mt-Hsp70-MIM44 system.

Adenosine Triphosphate↗

Altered Th1/Th2 balance associated with the immunosuppressive/protective effect of the H-2Ab allele on the response to allo-4-hydroxyphenylpyruvate dioxygenase.

The H-2Ab allele exerts a dominant down-regulatory effect on the anti-allo-HPPD (4-hydroxyphenylpyruvate dioxygenase) antibody response, through a hitherto unknown mechanism. In the present study, the allo-variable peptide bound to responder H-2Ak molecules with higher affinity than to H-2Ab ones, arguing against the operation of an affinity hierarchy. Quantitative polymerase chain reaction revealed differences in cytokine mRNA expression between suppressed and high-responder mice. Lymph node cells of responder but not suppressed mice contained high levels of interleukin (IL)-4 mRNA as early as 11 h post-immunization and continued to do so for at least 8 days; this early burst was paralleled by a small burst in transforming growth factor (TGF)-beta mRNA level. Differences in IL-12 mRNA were not detected, although an early IL-12 effect could not be excluded. Interferon (IFN)-gamma appeared to contribute to the suppression at later time points. Early treatment of responder mice with anti-IL-4 monoclonal antibody (11B11) down-regulated the antibody response. The proliferative T cell response from hyperimmunized mice was reduced but still detectable in the presence of an H-2Ab allele. Thus, in the presence of this allele, the Th1 response is enhanced and that of Th2 cells suppressed, apparently as a result of the bias of H-2Ab-restricted T cells in favor of the Th1 subset.

4-Hydroxyphenylpyruvate Dioxygenase↗

Evaluation of the reliability of 6 current anti-HIV-1/HIV-2 enzyme immunoassays.

The sensitivity for early detection of HIV antibodies and specificity of 6 anti-HIV-1/HIV-2 screening enzyme immunoassays (ELISAs) currently on the market were investigated by testing a panel of 249 well-characterized serum samples. The panel included sera from AIDS patients or children with congenital HIV infection, high-risk individuals and patients with conditions unrelated to AIDS. 'Tricky' sera (repeatedly positive results by ELISA and negative or indeterminate results by Western blot; n = 69) were also used in this evaluation along with 6 seroconversion panels. One second-generation assay (Biotest) and two third-generation assays (Abbott and Murex) showed the highest sensitivity for early detection of HIV-1 antibodies in seroconversion panels. A high specificity was achieved with the Cambridge Biotech (100%) and Ortho ELISA (99.4%). A relatively high rate of false-positive results was obtained with the Biotest (n = 10) and the Pasteur assays (n = 8) by testing 'tricky' sera and samples from high-risk individuals and from patients with other acute viral infections. In conclusion, it remains difficult to combine high specificity with an accurate detection of early seroconversion for anti-HIV-1/HIV-2 screening enzyme immunoassays.

Acquired Immunodeficiency Syndrome↗

Clinical application of volume estimation based on three-dimensional ultrasonography.

The development of three-dimensional sonography represents a milestone in the history of diagnostic ultrasound. It has become possible to evaluate a region of interest not only in the horizontal and vertical planes but also in a third, i.e. the frontal, plane. Among other possible applications, this technique greatly facilitates volume estimation. The objective of the present study was to evaluate the accuracy and precision of volumetry based on three-dimensional sonography. The results demonstrate a good correlation between estimated volumes and the volumes measured by transvaginal needle-guided follicle aspiration performed under sonographic visualization. Our findings confirm the conclusion of previous studies that three-dimensional sonography is making a valuable contribution to imaging techniques.

Analysis of Variance↗

[Successful outcome of "intracytoplasmic sperm injection" (ICSI) within the scope of in vitro fertilization].

Poor function of spermatozoa accounts for half of all human infertility. "Intracytoplasmic sperm injection" (ICSI) is a new micromanipulatory method for the treatment of male infertility. "ICSI" was performed in cases of oligoasthenozoospermia in 12 IVF cycles, obtaining a fertilisation rate of 71.2% of all micromanipulated oocytes. So far four ongoing pregnancies occurred. Thus "Intracytoplasmic sperm Injection" represents a new encouraging technique to conceive, even in cases of severe male infertility.

Adult↗

Congenital agminated segmental naevi.

We report a 39-year-old woman with agminated segmental naevi on the right side of her face. The lesions were present at birth, and she had no other congenital abnormalities.

Adult↗

Condensation pressure during amalgam placement in patients.

The purpose of this study was to investigate the condensation pressure during amalgam placement in patients. Forty-four practitioners were asked to fill two class 2 cavities in the lower jaw on their patients in their own practice with the aid of a force-measuring plugger. This device, with semiconductor strain gauges, allowed the dentist to have an identical tactile feedback as with any other plugger. Three different amalgams, with different shapes of alloy particles, were tested. The results showed a maximum condensation pressure of 8.9+/-2.4 MPa and 5.5+/-1.8 MPa with a small and a large amalgam plugger, respectively. Average condensation pressures were 3.7+/-1.3 MPa for the small and 2.2+/-0.9 MPa for the large instrument. The total working time required to fill a cavity was on average 131 s; the amalgam was effectively condensed for 44 s. No significant differences between amalgams with different shapes of alloy particles, no influence of time of day, and no difference between female and male dentists were found. This study showed that the condensation pressure is lower than often recommended, and that it is not statistically different from the values obtained in a previous laboratory study.

Chemical Phenomena↗

Echocardiography for teaching cardiac physiology in practical student courses.

We have introduced echocardiography into the physiology courses for medical students to improve their understanding of cardiac physiology. Echocardiography allows a visualization of the events of the cardiac cycle and facilitates the correlation of anatomic structures with their physiological functions. The students record views on the human heart in the long and short axis, they follow wall and value motions, and they interpret the obtained data in correlation with electrocardiography and phonocardiography. Echocardiography offers the opportunity to measure the interval of isovolumetric contraction and isovolumetric relaxation and permits the calculation of parameters assigned to left ventricular contractility. An evaluation showed that medical students consider echocardiography to be the most significant and interesting part of the physiology courses. In conclusion, echocardiography has been shown to be a valuable tool for teaching cardiac physiology.

Echocardiography↗