Search PubMed⌕ Search

Biomedical subjects

M Bock

Publications and source records attributed to M Bock.

At least 55 records · Page 3Linked to original sources

Efficient intracellular retrotransposition of an exogenous primate retrovirus genome.

The foamy virus (FV) subgroup of Retroviridae reverse transcribe their RNA (pre-)genome late in the replication cycle before leaving an infected cell. We studied whether a marker gene-transducing FV vector is able to shuttle to the nucleus and integrate into host cell genomic DNA. While a potential intracellular retrotransposition of vectors derived from other retroviruses was below the detection limit of our assay, we found that up to 5% of cells transfected with the FV vector were stably transduced, harboring 1 to approximately 10 vector integrants. Generation of the integrants depended on expression of functional capsid, reverse transcriptase and integrase proteins, and did not involve an extracellular step. PCR analysis of the U3 region of the 5' long terminal repeat and determination of proviral integration sites showed that a reverse transcription step had taken place to generate the integrants. Co-expression of a mutated envelope allowing particle egress and avoiding extracellular infection resulted in a significantly increased rescue of cells harboring integrants, suggesting that accumulation of proviruses via intracellular retrotransposition represents an integral part of the FV replication strategy.

Animals↗

Separation of arteries and veins in 3D MR angiography using correlation analysis.

Multiphase contrast-enhanced 3D MR angiography (MRA) data sets allow the separate visualization of the arterial and venous pulmonary vasculature. However, due to short arterial-to-venous bolus transit times in the lung, the generation of pure venograms without arterial overlay is difficult. To suppress arterial signal in venograms, early arterial phase data are typically subtracted from peak venous phase images. In this study, a correlation algorithm is used to postprocess the multiphase 3D MRA data sets. The cross-correlation between a measured arterial or venous reference function and the local signal-time course is computed which highlights image locations with a similar signal-time curve as the reference function and suppresses constant signal. Conventional maximum intensity projections (MIP) are generated from the arterial and venous correlation maps. In a study with five volunteers, an increase in SNR by a factor of 2.1 (1.8) of arterial (venous) correlation MIP images over subtraction MIP images was observed.

Contrast Media↗

Contrast optimization of fluid-attenuated inversion-recovery (FLAIR) MR imaging in patients with high CSF blood or protein content.

After surgical resection of a brain tumor or infection of the cerebrospinal fluid (CSF), elevated levels of blood by-products or protein contaminations are seen in the patient's CSF spaces. In fast fluid-attenuated inversion-recovery (FLAIR) imaging CSF signal is nulled by an appropriate choice of the inversion recovery time TI to improve the contrast between tissue structures adjacent to CSF-filled volumes. With contaminated CSF, however, the longitudinal relaxation time T(1) may change significantly, which results in an incomplete suppression in the FLAIR images, if standard inversion times are used. In this work, a fast single-voxel T(1) measurement pulse sequence with integrated T(1) calculation that allows determination the optimal TI value in 15 sec is presented. The method was tested in five patients after surgical resection of a brain tumor, where FLAIR MRI with and without contrast agent was performed to identify remaining tumor fragments at the margin of the resection cavity.

Brain Neoplasms↗

[Quantitative recording of renal function with magnetic resonance tomography].

AIM: To show the potential of various methods in magnetic resonance imaging for the evaluation of renal function. MATERIAL AND METHODS: A combined assessment of renal morphology, renal hemodynamics and function is proposed. Various techniques are explained, including multiphasic 3D gadolinium MR angiography, MR phase-contrast flow measurements, quantitative perfusion measurements with intravascular contrast agents, and MR renography and MR urography. The use of these techniques is demonstrated for renovascular diseases. RESULTS: The combined use of these techniques allows renal artery stenosis to be accurately detected and evaluation of renal blood flow, perfusion, glomerular filtration rate, and renal excretion. Based on true quantitative parameters, the hemodynamic and functional significance of the stenosis can be assessed. Renovascular diseases can be differentiated from renoparenchymal disease. CONCLUSION: For the assessment of renal function, functional magnetic resonance imaging techniques are an important alternative to nuclear medicine. The predictive value regarding the effect of revascularization is currently under investigation.

Contrast Media↗

An amplitude optimized single-shot hybrid QUEST technique.

Rapid MR imaging techniques either deposit high amounts of radio frequency power or require powerful gradient systems with high slew rates, which might not be available on conventional scanners. QUEST provides a fast imaging method with scan times of the order of hundreds of milliseconds and avoids these problems at the cost of low signal-to-noise ratios (SNR). In this work, QUEST was optimized with regard to image quality and measuring time. With the use of a Hybrid QUEST technique, that refocuses the image echoes several times, a spatial resolution of 1.9 mm x 1.6 mm x 5 mm was achieved. By acquiring both the necessary correction data and the image information in a single echo train, the Hybrid QUEST technique was implemented as a true single-shot measurement with a total scan time of 190 ms. Optimization of the excitation flip angles and the amplitude and phase correction methods for image reconstruction resulted in an improved SNR of 53.7 in the white matter of the human head for a 10 mm slice thickness at 1.5 T. In contrast to echo planar imaging techniques, no image distortions were observed with Hybrid QUEST in anatomic regions with many tissue interfaces.

Brain↗

Endogenous retroviruses and the human germline.

The human genome is rife with the proviral remains of many ancient retroviruses. The past year has seen significant progress in understanding the structure, distribution and potential function of many of these elements. Although hypotheses concerning the potential effects of these elements are common, however, incisive experiments to test any functions remain much less so.

Animals↗

Impact of notch filter use on waveforms of First- and Second-Order-Kernel responses from multifocal ERGs.

The filter settings of the amplifier section of ERG recording systems have large impact on the waveforms of the recorded responses. In this study, the effects of a 50 Hz notch filter were assessed for both First-Order-Kernel- (FOK) and Second-Order-Kernel-responses (SOK 1st slice) from multifocal ERGs recorded with a VERIS III system. Amplitude and phase responses of the amplifier section were recorded for typical filter settings with the notch filter active and inactive. Multifocal ERGs (MERGs) from a group of 11 normal subjects were recorded for both amplifier settings, the waveforms resulted from those recordings were compared in the time and frequency domain. To verify the results, the recordings without the notch filter were digitally filtered with a simulated notch filter and compared to the responses recorded with an active analog notch filter. The line filter has the biggest attenuation at 50 Hz with an additional phase jump of 180 degrees. The FOK responses of MERGs are assembled by frequencies below 65 Hz with main spectral components between 19 and 47 Hz. The 1st slice of the SOK consists of frequencies up to 100 Hz with main components between 19 and 84 Hz. Thus, if FOK recordings are to be analyzed, the notch filter of the amplifier can be used in order to cope with noise problems caused by the line frequency of 50 Hz. However, one must be aware that the attenuation of higher frequency components will lead to changes of the waveforms. For SOK analysis, main spectral components are attenuated and/or shifted in phase, which leads to completely different waveforms and severe distortion of the recording results.

Adult↗

Clinical applications of multifocal electroretinography.

The multifocal ERG using the m-sequence stimulation technique allows the derivation of 61 - 241 local ERG signals in a central visual field of about 60 degree diameter in a short time between 4 and 16 min. A recording in a light adapted state offers local information comparable to cone responses in the full-field ERG. Retinal functional losses due to regional disorders in outer retinal layers can be described in detail with this technique. In maculopathies decreased or absent central ERGs are found surrounded by normal ERG. The extent of the central lesion can be estimated. In diseases of the outer retina the pattern of distribution of multifocal ERG activity is similar to the the pattern of the visual field defect. In addition to decreased ERG amplitudes a delay of implicit time may be an important sign of pathology, i.e. the pronounced delay of implicit times in the periphery in retinitis pigmentosa and the implicit time delays in regions associated with retinal edema like CRVO and cystoid macula edema in intermediate uveitis. No simple correlation of the first order kernel multifocal ERG and field defects could be found in disorders of the ganglion cell layer. The multifocal ERG is therefore useful in the differential diagnosis of retinal and optic nerve diseases.

Diabetic Retinopathy↗

Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement.

A method for compliance estimation employing magnetic resonance pulse wave velocity measurement is presented. Time-resolved flow waves are recorded at several positions along the vessel using a phase contrast sequence, and pulse wave velocity is calculated from the delay of the wave onsets. Using retrospective cardiac gating in combination with an optically decoupled electrocardiogram acquisition, a high temporal resolution of 3 ms can be achieved. A phantom set-up for the simulation of pulsatile flow in a compliant vessel is described. In the phantom, relative errors of pulse wave velocity estimation were found to be about 15%, whereas in a volunteer, larger errors were found that might be caused by vessel branches. Results of pulse wave velocity estimation agree with direct aortic distension measurements which rely on a peripheral estimate of aortic pressure and are therefore less accurate. Studies in 12 volunteers show values of pulse wave velocity consistent with the literature; in particular the well-known increase in pulse wave velocity with age was observed. Preliminary results show that the method can be applied to aortic aneurysms.

Adult↗

Three-dimensional BANG gel dosimetry in conformal carbon ion radiotherapy.

In this study we applied BANG polymer-gel dosimetry using magnetic resonance imaging (MRI) to densely ionizing radiation such as carbon ion beams. BANG polymer gels were irradiated with a quadratic field of monoenergetic 12C ions at different beam energies in the range of 135 MeV u(-1) to 410 MeV u(-1). They were irradiated at the radiotherapy facility of the GSI, Darmstadt, Germany. Our object was to examine the saturation effect for densely ionizing radiation that occurs at high values of linear energy transfer (LET). The examination yielded the first effectiveness values that will be discussed in the following sections. A solid sphere and a hollow sphere were both irradiated with a horizontal pencil beam from the raster scanning facility at energies of 268 MeV u(-1) (solid sphere) and 304 MeV u(-1) (hollow sphere) respectively. MR dosimetry measurements were compared with data from a planning system. As far as quality is concerned, there is good agreement between the measured dose distributions of both samples and the dose maps from the planning software. The measured MR signals cannot be converted into absolute dose, since the relative efficiency is still unknown for mixed radiation fields of primary carbon ions and it is known only to a limited extent for nuclear fragments with different energies from highly energetic photon radiation. Model calculations are in progress in order to facilitate conversions of measured MR signals into dose.

Acrylamides↗

Rocuronium potency and recovery characteristics during steady-state desflurane, sevoflurane, isoflurane or propofol anaesthesia.

We have studied the potency and recovery characteristics of rocuronium during 1.25 MAC of isoflurane, desflurane, sevoflurane or propofol anaesthesia in 84 patients using electromyography. Potency was determined by a cumulative bolus technique. The mean ED50 of rocuronium was 169 (SD 41), 126 (32), 121 (28) and 136 (25) micrograms kg-1 during propofol, isoflurane, sevoflurane and desflurane anaesthesia, respectively (ns), and ED90 values were 358 (62), 288 (29), 289 (28) and 250 (28) micrograms kg-1, respectively. The reduction in ED90 was statistically significant for all three inhalation anaesthetics (P < 0.05) compared with propofol. After 120 min, the cumulative infusion rate of rocuronium to obtain twitch depression of 90-95% was 9.0 (1.9), 6.3 (1.6), 6.1 (2.0) and 6.1 (1.1) micrograms kg-1 min-1 during propofol, isoflurane, sevoflurane and desflurane anaesthesia, respectively (P < 0.01). Recovery index was 22 (13), 27 (10), 28 (13) and 26 (14) min under propofol, isoflurane, sevoflurane and desflurane anaesthesia, respectively (ns). There were no significant differences between the three potent inhalation anaesthetics in relation to potency, infusion requirements or recovery characteristics of rocuronium.

Adult↗

Combined assessment of obstructive sleep apnea syndrome with dynamic MRI and parallel EEG registration: initial results.

RATIONALE AND OBJECTIVES: To detect obstructive pharyngeal changes in sleeping patients with obstructive sleep apnea syndrome by dynamic MRI and concurrent EEG monitoring during true apneic episodes. METHODS: Five volunteers and eight patients with clinically diagnosed obstructive sleep apnea were polysomnographically monitored inside the scanner before, during, and after sleep discontinuation. After sleep interruption, the Mueller maneuver was performed to compare induced pharyngeal collapse with real collapse during sleep. RESULTS: In all patients, on-line EEG registration was achieved in the static magnetic field. Sleep was proved in four of the eight patients who showed typical EEG findings. A complete pharyngeal collapse was shown in two of the four sleeping patients. The other patients predominately showed local epi- and oropharyngeal obstructions in the apneic state. Compared with the apneic episodes, the Mueller maneuver did not reveal the same extent of pharyngeal narrowing, nor a complete collapse. CONCLUSIONS: Polysomnographically monitored MRI can directly assess findings induced by the pathophysiology of sleep apnea and shows promise for use in sleep investigation and therapy planning and monitoring.

Adult↗

Use of a transient assay for studying the genetic determinants of Fv1 restriction.

To probe the genetic determinants controlling the interaction between the retroviral restriction gene Fv1 and its murine leukemia virus target, we set out to develop rapid, transient assays for Fv1 function. Cells were transfected or transduced with Fv1 expression plasmids which can produce green fluorescent protein via an internal ribosome entry site positioned between the Fv1 and green fluorescent protein coding sequences. Fv1 function was then assessed by comparing virus replication in green fluorescent protein-positive and -negative cells, using retroviral vectors encoding a second fluorescent marker, yellow fluorescent protein, or beta-galactosidase. Using this assay, we could show that Fv1 specificities were not as absolute as previously thought, since the Fv1(b) allele was capable of interacting with "nonrestricted" B- and NB-tropic viruses and by shuffling the n- and b-alleles of Fv1, it was possible to generate a Fv1 molecule capable of restricting N-, B-, and NB-tropic viruses equally efficiently. Further, we could show that the presence of nonrestricting Fv1 in the same cell as restrictive Fv1 abrogates restriction, implying competition for binding to the retroviral target.

Animals↗

Interleukin-6 and its surrogate C-reactive protein are useful serum markers for monitoring metastasized malignant melanoma.

Malignant melanoma cells are known to secrete interleukin-6, and elevated interleukin-6 serum levels were reported to correlate with shorter median survival rates. We, therefore, investigated serum values of interleukin-6 and its surrogate C-reactive protein for the ability to discriminate progressive from non-progressive metastatic melanoma disease. Just prior to re-staging examinations, interleukin-6, C-reactive protein and the conventional parameter lactate dehydrogenase were determined in 74 patients with stage IV malignant melanoma according to the criteria of the American Joint Committee on Cancer. We found all tested serum parameters to be significantly elevated in progressive disease. Calculating sensitivities and specificities by logistic regression analysis, the highest sensitivities, according to the established thresholds, were found for interleukin-6 and C-reactive protein with 86% and 76%, respectively. Lactate dehydrogenase had the highest specificity with 94%. Calculating Somers' D rank correlation and the area under the "Receiver Operating Characteristic" curve, all three parameters showed high ability to driscriminate progressive from non-progressive disease. By multiple logistic regression, lactate dehydrogenase was identified to be the most statistically significant marker for progressive disease. We conclude that, comparable to lactate dehydrogenase, interleukin-6 and its surrogate C-reactive protein are useful serum markers for monitoring metastatic malignant melanoma.

Aged↗

Specific binding of recombinant foamy virus envelope protein to host cells correlates with susceptibility to infection.

The interaction of simian foamy viruses (FVs) with their putative cellular receptor(s) was studied with two types of recombinant envelope protein (Env). Transient expression of full-length Env in BHK-21 cells induced syncytia formation. However, selected stable transfectants fused with naive cells but not with each other. A soluble fusion protein of the Env surface domain with the Fc fragment of a human IgG1 heavy chain (EnvSU-Ig) was produced in the baculovirus expression system, purified to homogeneity, and used for binding and competition analyses. EnvSU-Ig but not unrelated Ig fusion proteins bound to cells specifically. Neutralizing serum blocked binding of EnvSU-Ig and, vice versa, serum-mediated neutralization was abrogated by the chimeric protein. Concomitant reduction of EnvSU-Ig binding and FV susceptibility was seen in Env-expressing target cells. Although EnvSU-Ig did not inhibit FV infection, very likely due to its displacement by multivalent virus-cell interactions, this divalent ligand should help to characterize functionally and to identify the ubiquitous FV receptor.

Animals↗

High-resolution pulmonary arterio- and venography using multiple-bolus multiphase 3D-Gd-mRA.

The purpose of this study was to demonstrate selective visualization of pulmonary arteries and veins with high spatial resolution for improved detection of vascular pathologies. Time-resolved pulmonary three-dimensional gadolinium-enhanced magnetic resonance angiograms (3D-Gd-MRA) were acquired with an ultrashort 3D fast low-angle shot (FLASH) sequence (TR/TE 2.3/0.9 msec) using asymmetric k-space sampling in readout, phase-encoding, and partition directions. In a single breath-hold four consecutive acquisitions were performed with a scan time of 6.28 seconds for each phase. A spatial resolution of 1.9 x 1.4 x 2 mm(3) could be achieved for a 12 cm thick 3D volume. To exploit the intrinsic enhancement kinetics of the pulmonary vascular system, the infusion of two gadolinium chelate boli was synchronized with the acquisition of the first and third data sets. This infusion strategy created two predominantly pulmonary arterial and venous data sets with the arterial and venous signal being maximally anti-correlated in time. A further separation of arterial and venous signal could be achieved by means of a correlation analysis. Eight patients with suspected thrombi in the pulmonary veins were studied. The calculated correlation angiographies provided high-quality pulmonary arterio- and venograms. Background signal was completely eliminated, allowing maximum intensity projection analysis of the full data set. In 7/8 patients no venous contamination of the arterial phase and vice versa was found. Patency of the pulmonary arteries and veins could be reliably assessed to the level of the segmental vessels. The combination of ultrafast multiphase 3D-Gd-MRA and dual-bolus injection with a correlation analysis of vascular signal provides high-resolution pulmonary arterio- and venograms. This imaging strategy initiates a new competitor to X-ray angiography.

Adult↗

Comprehensive MR evaluation of renovascular disease in five breath holds.

To detect a renal artery stenosis and assess its hemodynamic and functional significance in five breath holds. In a single MR exam, T1 weighted FLASH and T2 weighted fast spin echo techniques are used to assess renal morphology, multiphase 3D gadolinium (Gd) MRA to evaluate the renal arteries, and a segmented EPI cine phase-contrast technique to measure renal artery blood flow. A standardized image analysis is performed to assess kidney size, corticomedullar differentiation (CMD), parenchymal enhancement, the degree of renal artery stenosis, abnormalities in blood flow pattern, and any associated abdominal vascular disease. Multiphase 3D-Gd-MRA accurately assesses atherosclerotic renal artery disease particularly in the presence of an associated aortic aneurysm. Delayed parenchymal enhancement, loss of CMD, and decrease in kidney size can be detected. In combination with decreased systolic velocity components, the diagnosis of a hemodynamically and functionally significant stenosis can be made. High-resolution single-phase 3D-Gd-MRA is preferable for evaluation of fibromuscular dysplasia or hypoplastic vessels. The combination of different breath hold techniques in a single, standardized MR exam allows to detect the hemodynamic and functional significance of a renal artery stenosis.

Aged↗