Search PubMed⌕ Search

Biomedical subjects

M Block

Publications and source records attributed to M Block.

At least 109 records · Page 6Linked to original sources

[Allograft vasculopathy in the early phase of orthotopic heart transplantation: angiography, intravascular ultrasound and functional in vivo findings].

Accelerated graft coronary atherosclerosis disease is the main reason for long-term mortality and morbidity of heart transplant recipients. The aim of this in vivo study was to evaluate coronary atherosclerotic vessel abnormalities and endothelial function using angiography, intravascular ultrasound, and intracoronary acetylcholine infusion. Fourteen patients (11 male, 3 female; mean age 49.3 years) were examined early after heart transplantation (mean interval after transplantation: 11 weeks) because of coronary artery disease (n = 8), idiopathic dilatative cardiomyopathy (n = 7), mitral valve replacement (n: 1) or left atrial filiae of a leiomyosarcoma (n = 1). Mean age of the donor hearts (female n = 8) was 29 years; 3 patients received double- and 14 patients triple-immunosuppression. All patients underwent biplane ventriculography and coronary angiography; a total of 120 coronary segments (main stem 21, left anterior descending artery 85, circumflex artery 14) was examined by intravascular ultrasound (20 MHz, 3.5 F catheters). In 13 patients, acetylcholine was infused into the proximal left anterior descending artery (0.15 microgram/min to 150.0 micrograms/min) to evaluate vasomotion within this segment. Ventriculography demonstrated regional wall abnormalities in 2 patients, angiography revealed 9 noncritical stenotic segments in 5 patients. Intravascular ultrasound detected 52 cross-sectional areas with a three-layer appearance indicating intimal thickening. Mean circumferential expansion of intimal proliferation was 192 degrees and mean intimal thickness was 0.35 mm. Only 5 segments of the sonographically pathological cross-sectional areas showed angiographic evidence of atherosclerotic lesions. After intracoronary infusion at a lower dose (0.15 and 1.5 micrograms/min) of acetylcholine, vasoconstriction was observed in 2 patients, at a dose of 15.0 and 150.0 micrograms/min in 10 patients. This response to acetylcholine did not depend on the intravascular or angiographical extent of atherosclerotic vessel abnormalities. In heart transplant recipients, coronary artery abnormalities can already be depicted at an early stage using intravascular ultrasound. The majority of patients show coronary vasoconstriction following infusion of acetylcholine at a higher dose. Further investigation is necessary to clarify whether the depicted vessel wall abnormalities can already be interpreted as newly developed graft atherosclerosis and whether abnormal vasomotion after acetylcholine is indicative of endothelial dysfunction.

Acetylcholine↗

Comparison of frequency of aggravation of ventricular tachyarrhythmias after implantation of automatic defibrillators using epicardial versus nonthoracotomy lead systems.

The time of onset of 4,471 episodes of ventricular tachycardia (VT) or fibrillation (VF) in 40 of 65 patients with an implantable cardioverter-defibrillator (ICD) with endocardial defibrillation electrodes (group 1) and in 53 of 123 with epicardial defibrillation electrodes (group 2) was analyzed to examine whether the incidence of VT/VF immediately after surgery is greater than during further follow up and whether the site of lead placement exerts an influence on the occurrence of these arrhythmias. Actuarial survival rates free of VT/VF were 77, 65, and 54% at 1, 3 and 6 months, respectively, for group 1, and 84, 66 and 52%, respectively, for group 2. The probability of VT/VF was increased only during the first week after surgery; in that week, 12.8% of all patients had VT/VF, without significant differences between groups 1 and 2. Until the end of the first month, this percentage increased to 23%, whereas only 12 to 15% of patients had VT/VF during subsequent months. In 19 patients with third-generation devices capable of terminating tachycardias by overdrive pacing, 326 of 412 VT/VF episodes occurring in the first week after surgery were terminated by antitachycardia pacing, and only 86 had to be terminated by cardioversion or defibrillation. No postoperative exacerbation of inappropriate ICD therapies was observed in any group; 2 to 5% of patients per month received ICD therapies for atrial fibrillation or sinus tachycardia. Patients who received appropriate ICD therapies in the first week after surgery were at high risk of recurrence of VT/VF.(ABSTRACT TRUNCATED AT 250 WORDS)

Defibrillators, Implantable↗

Clinical experience with antitachycardia pacing and improved detection algorithms in a new implantable cardioverter-defibrillator.

OBJECTIVES: This study was conducted to assess the effectiveness of antitachycardia pacing modes and detection algorithms in patients with a new third-generation implantable cardioverter-defibrillator. METHODS: Twenty-three of 42 consecutive patients had coronary artery disease, 14 had dilated cardiomyopathy, 2 had prior valve replacement and 3 had arrhythmogenic right ventricular dysplasia. The mean ejection fraction was 41 +/- 14%; there were 31 men (74%) and 11 women, with a mean age of 53 years. On the basis of preoperative and postoperative electrophysiologic studies, in 28 patients antitachycardia pacing was postoperatively programmed randomly as "burst" (66%) or autodecremental "ramp" (34%) stimulation with a first coupling interval of 81% of tachycardia cycle length and up to 8 sequences with 3 to 10 stimuli. RESULTS: During a follow-up interval of 6.3 +/- 2.2 months, 15 patients were treated by antitachycardia pacing for a median of 6 (range 1 to 59) hemodynamically stable ventricular tachycardias (175 +/- 12 beats/min). In 5 patients, 22 ventricular tachycardias (9%) were not terminated by antitachycardia pacing but by cardioversion. Seven (3%) of these episodes accelerated (> 50 ms) during antitachycardia pacing. Syncope did not occur during these episodes. In seven patients initial antitachycardia pacing in cases of supraventricular tachycardias delayed charging and redetection prevented inappropriate discharges. Additional detection algorithms were programmed only after inappropriate therapy. The sudden "onset" and "sustained rate duration" criteria were programmed in three patients and the cycle length "stability" criteria in six patients, respectively. After activation of these detection algorithms only two of the seven patients had further inappropriate device discharges. CONCLUSIONS: Thus, antitachycardia pacing by this implantable cardioverter-defibrillator effectively and appropriately terminated 91% of hemodynamically stable ventricular tachycardias. Inappropriate device discharges were prevented in some patients by antitachycardia pacing and additional detection algorithms.

Adult↗

Surgical experience with defibrillator implantation using nonthoracotomy leads.

Between October 10, 1989, and June 17, 1991, 109 patients with life-threatening ventricular arrhythmias received an implantable cardioverter-defibrillator at our institution. In 50 patients, nonthoracotomy lead systems consisting of a subcutaneous chest wall patch electrode near the cardiac apex and one (Cardiac Pacemakers, Inc: Endotak C) or two (Medtronic: Transvene) transvenous electrodes were tested. The mean ejection fraction was 0.44 +/- 0.15 with a range from 0.19 to 0.81. Twenty-four patients had a history of open heart operation. In 43 patients the nonthoracotomy lead system was implanted, whereas in 7 patients epicardial patch lead systems were required due to elevated defibrillation thresholds during nonthoracotomy lead testing. There was one perioperative death unrelated to the operative procedure (hydrocephalus internus). Hemorrhage from the subcutaneous patch pocket or the device pocket that required reintervention occurred in 4 patients. During a mean follow-up of 13 +/- 5 months (range, 4 to 26 months) no dislocation of an endocardial lead, insulation defect, or lead fracture has been observed. In 1 patient, the lead system had to be removed due to infection of the subcutaneous patch pocket. The cardiovascular survival rate was 98% at 12 and 18 months, and freedom from sudden cardiac death was 100% at 6 and 12 months. In conclusion, defibrillator implantation using nonthoracotomy lead systems is feasible with a success rate of 86%, and during short-term follow-up no problems related to the lead system such as dislocation, fracture, or insulation defect have occurred.

Adolescent↗

Do patients with an implantable defibrillator live longer?

OBJECTIVES: This study was done to provide information on the potential benefit of implantable cardioverter-defibrillator therapy regarding sudden and arrhythmia-related deaths and to examine whether such therapy improves survival. BACKGROUND: Implantation of automatic cardioverter-defibrillators is reported to abort sudden cardiac death due to malignant tachyarrhythmias. METHODS: Between 1989 and 1992, 107 patients were screened for implantation of a third-generation implantable cardioverter-defibrillator combined with endocardial leads. Mean age was 57 +/- 13 years and mean ejection fraction was 40 +/- 15%. Sudden death, total arrhythmia-related death and total cardiac death were compared with the occurrence of fast ventricular tachyarrhythmias (> 240 beats/min), assuming that most of these arrhythmias would have been fatal without treatment by the implantable cardioverter-defibrillator. RESULTS: The surgical mortality rate was 2.7% in all 107 patients and 1% in the 99 patients who qualified for endocardial leads. During a follow-up period of 12 +/- 8 months, actuarial survival rate free of events at 6 months as well as at 12 and 18 months was 100% for sudden death, 97% for total arrhythmia-related death and 95% for total cardiac death. In contrast, after 6, 12 and 18 months, the rate of survival free of fast ventricular tachycardia was only 83%, 74% and 69%, respectively, and the rate of survival free of any ventricular tachyarrhythmia was only 59%, 49% and 40%, respectively. CONCLUSIONS: The outcome of patients treated with an implantable cardioverter-defibrillator and endocardial defibrillation leads is excellent. For many patients, this treatment is probably lifesaving.

Adult↗

Radiofrequency catheter ablation of ventricular tachycardia following implantation of an automatic cardioverter defibrillator.

OBJECTIVES: The present study reports on the complementary role of two nonpharmacological options of antiarrhythmic therapy. BACKGROUND: Catheter ablation, antitachycardia surgery, and the implantable cardioverter defibrillator (ICD) have become important tools in the management of ventricular tachyarrhythmias. However, the emergence of ventricular tachyarrhythmias after implantation of an ICD is possible because the arrhythmogenic substrate is not affected. PATIENTS AND METHODS: Six of 180 patients developed frequent episodes of monomorphic ventricular tachycardia (n = 2) or incessant ventricular tachycardia (n = 4) following implantation of an ICD and underwent radiofrequency (RF) catheter ablation. Catheter ablation was performed using a RF generator HAT 200. Energy was delivered between a 4-mm tip electrode of the ablation catheter and a patch electrode. RESULTS: Catheter ablation was done 6.8 +/- 5 months following ICD implantation; 6 +/- 2.2 RF impulses were delivered at the site of origin of ventricular tachycardia characterized by early endocardial activation during ventricular tachycardia, identical pace mapping and long latency between stimulus, and QRS-complex in five patients. New bundle branch reentry was the underlying mechanism of ventricular tachycardia in one patient. RF catheter ablation resulted in termination of incessant ventricular tachycardia. Immediately postablation, the documented ventricular tachycardia was rendered noninducible in all patients. No ICD malfunctions have been observed. One patient died due to heart failure 24 hours after successful ablation of the incessant ventricular tachycardia. During a follow-up of 5-19 months, episodes of ventricular tachycardia recurred in four patients. All episodes could be controlled by the ICD without frequent cardioversions. CONCLUSION: RF catheter ablation is a complementary therapeutic option in case of frequent or incessant ventricular tachycardia after ICD implantation.

Adult↗

[Therapy of ventricular tachyarrhythmia with implantable cardioverters/defibrillators--mortality and complications using epicardial electrodes].

Technical improvements of third generation implantable cardioverter defibrillators (ICD) like antitachycardia pacing modalities lead to an extended use of ICDs, not only in patients with aborted sudden cardiac death, but also in patients with hemodynamically tolerable ventricular tachycardia. In addition, anticipated results of current prospective studies might indicate the prophylactic use of ICDs in patients with high risk for sudden cardiac death, but without documented ventricular tachyarrhythmias. This report reviews mortality and complications associated with the ICDs with epicardial defibrillation leads. Mortality is separated in cardiac death, sudden cardiac, arrhythmogenic "not so sudden" cardiac death, and overall mortality. Pulmonary complications and infections are related to the underlying disease and the surgical procedure. Device- and lead-related complications, high defibrillation thresholds, pacemaker interactions, inappropriate shocks, arrhythmic effects, syncope, and psychosocial problems are reported, respectively.

Adolescent↗

[Diagnostic and therapeutic problems in idiopathic prolonged QT syndrome. A case report].

The case of a 36-year-old woman with suspected idiopathic long QT syndrome is reported. Diagnosis was made late after syncopal attacks and several episodes of resuscitation had occurred. Although therapy with a beta-blocking agent was initiated and a cardioverter/defibrillator was implanted, the patient died, due to a hydrocephalus internus resulting in cerebral damage. Diagnostic and therapeutic problems in idiopathic long QT syndrome are discussed.

Adult↗

Doppler echocardiographic assessment of the pressure gradient during bicycle ergometry in hypertrophic cardiomyopathy.

To assess the behavior of the subvalvular pressure gradient under physical exercise, 13 patients with obstructive hypertrophic cardiomyopathy were examined during upright bicycle ergometry by means of Doppler echocardiography. Additionally, right-sided cardiac catheterization was performed within 7 days. In 10 patients adequate Doppler tracings could be obtained during exercise. The Doppler-derived systolic pressure gradient increased from 75 +/- 24 to 140 +/- 42 mm Hg (p less than 0.0005). This was associated with an increase in the duration of the systolic mitral-septal contact from 59 +/- 21 to 136 +/- 28 ms (p less than 0.0005). Correlation between the pressure gradient and the duration of mitral-septal contact at rest and during exercise was good (r = 0.86), whereas correlation between the resting and exercise pressure gradient (r = 0.34) did not reach statistical significance. The increase in stroke volume during exercise, from 90 +/- 18 to 95 +/- 24 ml, was significant (p less than 0.05) but minimal. Therefore, only a moderate increase in systolic flow, from 205 +/- 54 to 268 +/- 78 ml/s (p less than 0.0005), was observed. Outflow tract resistance, defined as the ratio of the pressure gradient to systolic flow, increased from 0.38 +/- 0.11 to 0.57 +/- 0.24 mm Hg.s/ml (p less than 0.01). Thus, in a selected group of patients with hypertrophic cardiomyopathy a substantial increase in the maximal pressure gradient during upright bicycle ergometry was demonstrated in most patients. Exercise Doppler echocardiography may be valuable to assess the hemodynamic significance of obstruction in individual patients in a physiologic setting and has a potential to monitor the effect of therapeutic interventions.

Adult↗

Prediction of the site and severity of obstruction in hypertrophic cardiomyopathy by color flow mapping and continuous wave Doppler echocardiography.

OBJECTIVE: We investigated whether the site and severity of an obstruction in hypertrophic cardiomyopathy can be accurately predicted by the combined use of color-coded and continuous wave Doppler echocardiography. BACKGROUND: Predicting the site of obstruction by end-systolic cavity shape is not reliable. Therefore, hemodynamic localization of the obstruction is required before surgery is performed. Such localization should be possible with color flow imaging, which provides two-dimensional velocity mapping reflecting the distribution of pressures within the left ventricle. Discrepancies in assessment of the pressure gradient by Doppler echocardiography and cardiac catheterization (which are usually not performed simultaneously) may be due to spontaneous variation of the dynamic obstruction in addition to technical factors related to both methods. METHODS: Twenty consecutive patients with hypertrophic cardiomyopathy were examined 1 day before transseptal left heart catheterization. The obstruction site was defined by color flow mapping. The pressure gradient was determined by continuous wave Doppler echocardiography. Measurements were also performed simultaneously in 10 patients during cardiac catheterization. RESULTS: Midventricular obstruction was correctly identified in 4 patients and subvalvular obstruction in 15 patients. One patient had no obstruction at rest. Invasively and noninvasively determined pressure gradients correlated well (r = 0.89, SEE = 16.3 mm Hg). Multiple single-beat analysis in 10 patients, also simultaneously examined with Doppler echocardiography and catheterization, yielded an excellent correlation (r = 0.97, SEE = 13.1 mm Hg). Comparing the simultaneous (r = 0.96, SEE = 12.5 mm Hg) and nonsimultaneous (r = 0.81, SEE = 23.8 mm Hg) recordings in these patients, we found that the spontaneous variation of the dynamic obstruction mainly accounted for discrepancies (p less than 0.05). CONCLUSION: The combined use of color-coded and continuous wave Doppler echocardiography provides the relevant hemodynamic information required for decision-making in patients with hypertrophic cardiomyopathy who are considered for transaortic myectomy.

Adult↗

Implantation of a cardioverter/defibrillator in the subpectoral region combined with a nonthoracotomy lead system.

An implantable cardioverter defibrillator was placed into a subpectoral pocket via the incision for cephalic venotomy during implantation of a nonthoracotomy lead system. The approach obviated another incision and subcutaneous tunneling of the leads. There were no perioperative complications and after 6 months of follow-up, the patient continues to tolerate the device satisfactorily.

Electric Countershock↗

Role of ventricular tachycardia surgery and catheter ablation as complements or alternatives to the implantable cardioverter defibrillator in the 1990s.

Although the implantable cardioverter defibrillator is used increasingly, other nonpharmacological approaches have their indications and merits. Furthermore, as the natural history of ventricular tachyarrhythmias or their underlying structural cardiac abnormality, i.e., coronary artery disease, dilated cardiomyopathy, arrhythmogenic right ventricular disease, etc. change, the mode of therapy may be modified accordingly. Because of the disappointing results of the CAST study in previously asymptomatic patients after myocardial infarction and the evidence that failure of one or two antiarrhythmic drugs tested by programmed ventricular stimulation in patients with documented sustained ventricular tachycardia or fibrillation predicts further drug failure, there will be a significant increase in the use of implantable cardioverters defibrillators in the 1990s. However, care should be taken to avoid inappropriate use of these devices.

Adult↗

Efficacy of automatic multimodal device therapy for ventricular tachyarrhythmias as delivered by a new implantable pacing cardioverter-defibrillator. Results of a European multicenter study of 102 implants.

BACKGROUND: Third-generation implantable cardioverter-defibrillators are devices designed to treat ventricular tachycardia (VT) and ventricular fibrillation (VF) by means of overdrive pacing, cardioversion, or defibrillation. So far, the efficacy of tiered therapy has been documented only in small series. Therefore, a European multicenter clinical evaluation study of a new tachyarrhythmia control device, the Medtronic PCD pacer-cardioverter-defibrillator with epicardial patch-lead configuration, was undertaken. METHODS AND RESULTS: We report on 102 patients (mean age, 55 +/- 13 years) from 11 European centers. PCD devices implanted between May 1989 and February 1991 were included. The patients suffered from hemodynamically significant ventricular tachyarrhythmias not suppressed by antiarrhythmic drug therapy and unrelated to acute myocardial infarction; one patient had nonsustained VT and severely depressed left ventricular function. Seventy patients had coronary artery disease with old myocardial infarctions, 23 had cardiomyopathies of various etiologies, and nine patients had no detectable heart disease. Mean ejection fraction was 36 +/- 14% (range, 10-76%). Mean intraoperative defibrillation threshold (51 patients) was 10.6 +/- 5.1 J (range, 2-18 J). The documented follow-up ranged from 1 to 21 months (mean, 9.4 +/- 5.8 months), or 79.9 cumulative patient-years. Perioperative mortality was 3.9%. The actuarial survival rate at 12 months was 91%. One sudden arrhythmic death occurred. Sixty patients (58%) received device therapy. Seventeen patients had therapies only for "VF" episodes, 16 patients only for VT, and 28 patients for VT and "VF" episodes. Based on device memory data, 1,235 spontaneous VT episodes were detected and treated in 43 patients. Twelve hundred four of these VT episodes received painless initial antitachycardia pacing therapy, restoring sinus rhythm in 91%. The 108 ongoing episodes received 209 multiple therapeutic attempts. Eighty-five additional overdrive pacing therapies restored sinus rhythm in 30%. Initial ineffective antitachycardia pacing therapies received 51 cardioversion pulses. The success rate was 61%. Seventy-three additional cardioversion pulses were delivered to backup ineffective pacing therapy as well as ineffective secondary cardioversion pulses. Their success rate was only 40%. Two hundred eighty-six spontaneous episodes were detected in 44 patients as "VF." Overall defibrillation efficacy was 97.6%. CONCLUSIONS: The implanted device nearly eliminates sudden arrhythmic death in patients with documented, potentially fatal ventricular tachyarrhythmias. Automatic tiered therapy is highly effective to restore sinus rhythm, provided that an integrated two-zone tachycardia detection algorithm is used, assigning lower tachycardia rates to overdrive pacing and/or cardioversion and higher tachycardia rates to defibrillation. In general, spontaneous VTs can be terminated by automatic overdrive pacing, and painful or disturbing countershock therapies are not required to terminate the majority of spontaneous VT episodes.

Death, Sudden, Cardiac↗

[Percutaneous high frequency current catheter ablation in permanent ventricular tachycardia of the "bundle-branch reentry" type after implantation of an automatic cardioverter-defibrillator].

A 65-year-old female patient with a history of recurrent sustained ventricular tachycardia presented with an incessant ventricular tachycardia (cycle length 360-400 ms) following implantation of a cardioverter-defibrillator (ICD). The tachycardia could not be terminated by antiarrhythmic drug treatment, antitachycardia pacing or internal defibrillation via the ICD. An invasive electrophysiologic study revealed that the mechanism of this newly occurring tachycardia was bundle branch reentry. The patient underwent emergency catheter ablation using radiofrequency (RF) current. Endocardial mapping of the right bundle branch and of the distal His bundle was performed and a bundle branch reentry tachycardia was diagnosed. After delivery of the fifth RF-impulse, the tachycardia terminated and complete AV block was induced. No malfunction of the ICD was observed following RF-ablation. The patient was hemodynamically stable with a junctional escape rhythm and antibradycardia pacing back-up of the ICD (VVI-mode). This case report demonstrates the feasibility of RF catheter ablation in the treatment of incessant bundle branch reentry tachycardia as a complementary option after implantation of an ICD.

Aged↗