BACKGROUND: A newly developed classification system relates adverse events to the surgical procedure or the function of the implantable defibrillator. METHODS AND RESULTS: Adverse events were monitored during prospective clinical evaluation of the Medtronic model 7219 Jewel ICD and were classified according to the definitions of the ISO 14155 standard for device clinical trials into 3 groups: severe and mild device-related and severe non-device-related adverse events. In addition, events were related to the surgical procedure, treatment with the device, or cardiac function. Seven hundred seventy-eight patients were followed up for an average of 4.0 months after ICD implantation. In total, 356 adverse events were observed in 259 patients. At 1, 3, and 12 months after ICD implantation, 99%, 98%, and 97% of the patients, respectively, survived; 95%, 93%, and 92%, respectively, were free of surgical reintervention; and 79%, 68%, and 51%, respectively, were free of any adverse event. Twenty patients died: 6 deaths were related to the surgical procedure, 12 deaths were considered unrelated to ICD treatment, and 2 patients died of an unknown cause. Of 111 nonlethal severe adverse device effects, 47 required surgical intervention, 19 times for correction of a dislodged lead. Inappropriate delivery of therapy was observed 128 times in 111 patients, and the events were typically resolved by reprogramming or drug adjustment. Nine of these required rehospitalization. CONCLUSIONS: Approximately 50% of patients experience an adverse event within the first year after ICD implantation. The observed adverse event rate depends on the definitions and the prospective monitoring. The incidence of inappropriate therapy emphasizes the need for improved detection algorithms and for quality-of-life evaluations, especially when considering ICD treatment in high-risk but arrhythmia-free patients.

Algorithms↗

Changes of the membrane potential profile induced by verapamil and propranolol.

The effects of the organic calcium channel blocker verapamil and the beta-receptor blocker propranolol on dipole (phi(d)) and surface (phi(s)) potentials of bilayer lipid membranes were studied. The boundary potentials (phi(b)= phi(d) + phi(s)) of black lipid membranes, monitored by conductance measurements in the presence of nonactin and by capacitive current measurements were compared with phi(s) calculated from the electrophoretic mobility of lipid vesicles. It was shown that the increase of boundary potential, induced by the adsorption of the positively charged propranolol, was caused solely by an increase in surface potential. Although phi(s) also increases due to the adsorption of verapamil, phi(b) diminishes. A sharp decrease of the dipole potential was shown to be responsible for this effect. From Langmuir adsorption isotherm the dissociation constant Kd of verapamil was estimated. The uncharged form of verapamil (Kd=(0.061+/-0.01) mM at pH 10.5) has a tenfold higher affinity to a neutral bilayer membrane than the positively charged form. The alteration of membrane dipole potential due to verapamil adsorption may have important implications for both membrane translocation and partitioning of small or hydrophobic ions and charged groups of membrane proteins.

Adrenergic beta-Antagonists↗

Syncope in patients with an implantable cardioverter-defibrillator: incidence, prediction and implications for driving restrictions.

OBJECTIVES: This retrospective study was undertaken to provide information on occurrence, risk prediction and prevention of syncope in patients with an implantable cardioverter-defibrillator (ICD). BACKGROUND: ICDs effectively terminate ventricular tachycardia and fibrillation (VT/VF). Incapacitating symptoms, such as syncope, may still occur. METHODS: We performed a retrospective analysis of data from 421 patients (clinical history, outpatient chart reviews and episode data) with mean (+/-SD) follow-up of 26 +/- 18 months. RESULTS: Of 421 patients, 229 (54.4%) had recurrent VT/VF, and 62 (14.7%) had syncope. The actuarial survival rate free of VT/VF was 58%, 45% and 37% and that for survival free of syncope was 90%, 85% and 81% at 12, 24 and 36 months after implantation, respectively. Once VT/VF had occurred, 76%, 68% and 62% of patients remained free of syncope during the following 12, 24 and 36 months, and 68%, 64% and 56% remained free of second syncope 12, 24 and 36 months after first syncope, respectively. In cases of syncope, the mean cycle length (CL) of VT was 251 +/- 56 ms. A low baseline left ventricular ejection fraction (LVEF), induction of fast VT (CL <300 ms) during programmed ventricular stimulation and chronic atrial fibrillation (AF) were associated with an increased risk of syncope. If the LVEF was >40%, fast VT had not been induced, and patients had no chronic AF; 96%, 92% and 92% of patients remained free of syncope after 12, 24 and 36 months, respectively. Once patients had a VT recurrence, syncope during the first VT and a high VT rate were the strongest risk predictors of future syncope. CONCLUSIONS: Identification of patients with an ICD with a low and high risk of syncope seems to be feasible and might help as a guide to driving restrictions in such patients.

Adolescent↗

The impact of mental health service integration on systemic function: a staff perspective.

OBJECTIVE: The purpose of this study was to investigate the perceptions of community staff regarding service process and quality, while a public mental health service integrated acute inpatient and continuing care components. METHODS: The study employed a naturalistic successive measures design in which community mental health staff completed a questionnaire on three occasions during the integration process. RESULTS: Staff perceived overall service quality to improve during the integration process with continuity of care being the area subject to greatest improvement. CONCLUSIONS: The integration of acute inpatient and continuing care services resulted in changes to service process and outcome, which were judged by staff to be beneficial, especially with respect to continuity of patient care.

Analysis of Variance↗

Antiarrhythmic therapy--future trends and forecast for the 21st century.

This article discusses recent changes in antiarrhythmic therapy, with a focus on nonpharmacologic therapy (electrode catheter ablation, implantable cardioverter-defibrillators [ICDs]), and puts them into perspective for the coming years. The treatment of supraventricular tachycardias and tachycardia involving accessory pathways is likely to remain the domain of catheter ablation. With promising new techniques under investigation, the spectrum of arrhythmias that can be cured will probably be expanded. Treatment of life-threatening ventricular arrhythmias is likely to remain the domain of the ICD in the foreseeable future. With the safety net of the ICD in place, new antiarrhythmic drugs or other forms of antiarrhythmic therapy can be developed and tested.

Anti-Arrhythmia Agents↗

Patients with valvular heart disease presenting with sustained ventricular tachyarrhythmias or syncope: results of programmed ventricular stimulation and long-term follow-up.

BACKGROUND: Programmed ventricular stimulation is commonly used to guide therapy in post-myocardial infarction patients with sustained monomorphic ventricular tachycardia (VT) or ventricular fibrillation (VF). In patients with valvular heart disease presenting with spontaneous VT, VF, or syncope, the usefulness of this technique is still unclear. The aim of the study was to analyze whether programmed ventricular stimulation was helpful in guiding therapy and determining prognosis in 97 patients with valvular heart disease presenting with VT (60%), VF (18%), or syncope (22%). METHODS AND RESULTS: Patients were classified as having either predominant ventricular pressure or volume overload or no significant pressure or volume overload. Overall, sustained VT or VF was inducible in 38 (39%) and 19 (20%) patients, respectively. Forty-six (47%) patients were discharged on antiarrhythmic drugs, 29 (30%) received an implantable cardioverter-defibrillator, and 22 (23%) remained without therapy. With serial drug testing, inducibility was completely or partially suppressed in 18 (19%) and 9 (9%) patients, respectively. During a mean follow-up of 51 months (n=97), 17 patients (18%) died (sudden death, n=7; heart failure, n=4; noncardiac causes, n=6). One-, 2- and 3-year event-free survival for sudden death, sustained VT, or VF was 77%, 68%, and 61%, respectively. Only inducibility of VT during baseline study (P<.0003) and left ventricular volume overload (P<.008) were significant predictors of arrhythmic events. Recurrence of arrhythmic events occurred in 56% and 56% of patients with complete or partial suppression of inducibility during serial drug testing as well as in 10 of 19 (53%) patients without a change in inducibility. CONCLUSIONS: Although programmed ventricular stimulation seems to predict adverse outcome, serial drug testing is unreliable in guiding therapy. The type of workload imposed on the ventricles influences outcome, being worse in patients with left ventricular volume overload. Therefore, implantation of a cardioverter-defibrillator should be considered early for the management of these patients.

Adolescent↗

[Results of testing defibrillator function of implanted cardioverter/defibrillators].

Postoperative tests of implantable cardioverter defibrillators (ICDs) are routinely performed to ensure appropriate defibrillation by the device. However, efficacy and complications of this procedure are unknown. To scrutinize the currently accepted indications to test the defibrillation function of the ICD we retrospectively analyzed 844 ICD-tests in 439 ICD-systems and 409 patients. 755 ICD-tests (89.4%) were routinely performed (57% before discharge and 43% during follow-up); 58 tests (6.9%) were performed after a change of the antiarrhythmic drug regimen, 24 tests (2.9%) after a revision of a part of the ICD-system, and seven tests (0.8%) because of a suspected dysfunction of the ICD. During routine-tests six ICD-systems (0.8%) failed to defibrillate the patient. However, in all but one test abnormalities of the ICD-system had been observed before the test. After addition of antiarrhythmic drugs, three of 58 ICD-systems (5.2%) failed to defibrillate the patient during the test (amiodarone: n = 2, flecainide: n = 1). Four of seven ICD-systems (57%) tested due to a suspected dysfunction failed to defibrillate the patient. After revisions of parts of the ICD-systems, ICD-tests never revealed a failure of defibrillation. During 16 ICD-tests (1.9%) complications occurred. The most frequent complications was inappropriate shocks (n = 10; 1.2%), the most severe one (transient) neurologic symptoms (n = 4; 0.48%). Our experience demonstrates that postoperative tests of the defibrillation function of ICDs rarely reveal ICD-dysfunction. As testing is unpleasant for the patient and not free of complications, tests might be restricted to those patients in whom an ICD-dysfunction is suspected (based on clinical presentation, results of chest-x-ray, testing of sensing signal and stimulation threshold) or class I or class III antiarrhythmic drugs have been added to the antiarrhythmic drug regimen.

Adolescent↗

[Quality of life after implantation of a cardioverter-defibrillator (ICD)--results of an empirical study of 132 ICD patients].

All 181 patients with malignant arrhythmias who have been provided with an implantable cardioverter-defibrillator (ICD) at the University Clinics of Muenster during the last 3 years, were investigated by a clinical questionnaire on quality of life (QOL). 132 patients answered and could be included in the study (response rate 73%). The mean age of the patients was 55 +/- 11.8 years, 73% males, 60% had already retired. In the general view 51% of the patients reported fair to excellent quality of life, while 24% gave a negative description of their QOL. 26% of the patients suffered from side-effects of the treatment, primarily from unspecific psychological complaints and ICD-related disturbances. "Unrest" was the predominant psychological complaint (64% of the patients), followed by rumification, shortness of breath, weakness and sleep disturbances. Somatic function and sex life were the functional areas primarily affected (more than half of the patients complaining about these). The "Psychological General Well-Being Index (PGWB)" showed reduced well-being in 61% of the patients. Comparing with the literature and regarding the PGWB-scales well-being, anxiety, and depression no significant differences could be found in comparison with other cardiologic samples after bypass-surgery or valve replacement. The results indicate the need of individual counseling and offers of psychosocial support for this highly strained group to reduce anxiety and to improve the quality of life in order to help the patient to gain greater overall benefit from the new ICD-therapy.

Activities of Daily Living↗

Influence of water quality on the accumulation of methyl 203mercury in gill tissue of minnow (Phoxinus phoxinus).

Effects of pH and concentrations of Cl and Ca on the uptake of methyl mercury (MeHg) in the gills of the minnow (Phoxinus phoxinus) were studied. Chloride concentration and pH in the water affect the speciation of MeHg. Ca was included because it affects the permeability of the gills and could therefore indirectly affect the amount of MeHg accumulated in the tissue. The species formed differ in hydrophobicity, as reflected in their octanol/water partition coefficients (Pow). Both a reduction in pH and an increase in Cl- concentration increased the Pow of MeHg. Ca had no effect on speciation. The accumulation of MeHg in the gill tissue increased with decreasing pH (from pH 7.0 to pH 3.9). Accumulation also increased as Cl- concentrations were increased from 10(-7) to 10(-1) M at pH 7.0. An increase in Ca concentration did not alter the accumulation of MeHg beyond a decrease in MeHg accumulation as Ca increased from 20 to 50 microM. We conclude that, of the water-quality factors studied, those affecting chemical speciation were most important in determining the MeHg uptake. The Ca concentration appears to be of minor importance.

1-Octanol↗

The perception of internal circuit noise in hearing aids by listeners with normal hearing.

Internal circuit noise in hearing aids is distracting to a listener and, if loud enough, may interfere with intelligibility, either by direct masking of weak components of speech or through the generation of undesired intermodulation products, which can also act as a source of masking. The objective characteristics of noise may be measured; however, wearers of hearing aids often differ in their subjective reporting of the perceived characteristics of the internal noise. This study reports on the results for four listeners with normal hearing of matching pitch and amplitude to the internal noise generated within a series of hearing aids. Results of these experiments showed that the listeners (a) primarily matched the perceived pitch of the noise to the frequency of their most sensitive hearing, and (b) matched the perceived level of the noise approximately to the total SPL noise level.

Adult↗

Effects of yellow optical filters on contrast sensitivity function of albino patients.

BACKGROUND: Yellow ophthalmic filters are often prescribed for albino patients in an effort to enhance visual performance. The effects of a moderate- and a high-excitation purity yellow filter on the contrast sensitivity function (CSF) of ten albino patients were investigated. Hue discrimination loss induced by each filter was also evaluated. METHODS: Three monocular CSF curves (best-corrected eye) were determined for each subject: one while viewing through a #3 Kodak Wratten filter, one through a #12 filter, and one used no filter. Panel D-15 color tests were administered to five albino patients viewing through each filter. RESULTS: Using an analysis of variance (ANOVA) and a Student-Newman-Keuls Analysis, no statistical difference at the 0.05 levels of confidence was found between using no filter, the #3 filter, or the #12 filter CSF curves. A statistically significant blue-yellow hue confusion was induced by the #12 filter. CONCLUSIONS: While neither filter was shown to enhance nor degrade the CSF among these subjects, a more extensive investigation may reveal that subtle but real contrast enhancement occurs with yellow filter use. High-purity filters should be avoided to minimize hue recognition losses.

Adolescent↗

Targeting of antihapten antibodies to activated T cells via an IL-2-hapten conjugate prolongs cardiac graft survival.

Antihapten antibodies binding to ligand-hapten conjugates are able to mediate complement mediated lysis in vitro. Based on this observation we propose a new in vivo immunotherapy using molecules that combine a low molecular weight hapten binding to antibodies preexisting in serum and a cell specific ligand. The ligand-hapten conjugates are potential cytotoxic drugs which may (1) be specific for a given target cell, (2) be nonimmunogenic, (3) be of low molecular weight, (4) form soluble complexes with preexisting antibodies resulting in prolonged half life of the drug, and (5) induce a potent antibody mediated rejection of target cells. These novel compounds could be useful for the elimination of certain cell subsets involved in allograft rejection, cancers, infectious diseases, etc., without some of the pitfalls of conventional immunotherapies. The feasibility of this approach was demonstrated in an animal model using a compound consisting of one interleukin 2 and one fluorescein molecule (IL-2-FITC). BALB/c mice (H2d) previously immunized and expressing anti-FITC antibodies were transplanted with a fully mismatched C57BL/6 (H2b) heterotopic heart allograft. Untreated controls rejected their graft by day 9 (MSD = 9 +/- 0.7). Mice with preexisting anti-FITC antibodies treated with IL-2-FITC maintained their grafts for 38.7 +/- 7.1 days (P < 0.02). No prolongation of graft survival was observed in immunized animals that were treated with IL-2 alone (MSD = 10 +/- 1.4). Nonimmunized animals treated with IL-2-FITC rejected their grafts on day 9.4 +/- 1.1. This demonstrates that IL-2-FITC therapy specifically prolonged graft survival in animals with circulating anti-FITC antibodies. The data suggest that a ligand/hapten pair can redirect preexisting antihapten antibodies toward target cells in vivo. Such compounds may be developed for human use as alternatives to polyclonal or monoclonal antibody therapy.

Animals↗