Efficiently learning multilayer perceptrons.

A learning algorithm for multilayer perceptrons is presented which is based on finding the principal components of a correlation matrix computed from the example inputs and their target outputs. For large networks our procedure needs far fewer examples to achieve good generalization than traditional on-line algorithms.

Algorithms↗

Adolescents' and adults' understanding of probability expressions.

PURPOSE: To examine whether there are differences between adolescents and adults in their interpretation of probability terms. METHODS: Participants were 20 fifth graders, 54 seventh graders, 45 ninth graders, and 34 young adults (mean adult age = 26.24 years, standard deviation = 2.09) from the San Francisco Bay area. They completed a self-administered survey asking them to assign percentage estimates (0% to 100%) to 30 randomly ordered probability terms. RESULTS: Significant age differences in the mean percentage estimates for 8 of the 30 terms were shown. Moreover, we found large variation in the interpretation of most probability terms studied, with larger variation among the adolescents than adults. Finally, all age groups had some difficulty correctly differentiating between "possibly" and "probably". CONCLUSIONS: Owing to wide variation in the interpretation of probability terms, both within and across age groups, we suggest health practitioners use percentages rather than probability terms to convey risk to both adolescents and adults.

Adolescent↗

The role of behavioral experience in judging risks.

This study used conditional risk assessments to examine the role of behavioral experiences in risk judgments. Adolescents and young adults (ages 10-30; N = 577) were surveyed on their risk judgments for natural hazards and behavior-linked risks, including their personal experiences with these events. Results indicated that participants who had experienced a natural disaster or engaged in a particular risk behavior estimated their chance of experiencing a negative outcome resulting from that event or behavior as less likely than individuals without such experience. These findings challenge the notion that risk judgments motivate behavior and instead suggest that risk judgments may be reflective of behavioral experiences. The results have implications for health education and risk communication.

Adolescent↗

Singularity spectra of rough growing surfaces from wavelet analysis

We apply the wavelet transform modulus maxima method [A. Arneodo, N. Decoster, and S. G. Roux, Phys. Rev. Lett. 83, 1255 (1999)] to the analysis of simulated surfaces grown by molecular-beam epitaxy. In contrast to the structure function approach commonly used in the literature, this method permits an investigation of the complete singularity spectrum. We focus on a kinetic Monte Carlo model with Arrhenius dynamics, which in particular takes into consideration the process of thermally activated desorption of particles. We find a wide spectrum of Holder exponents, which reflects the multiaffine surface morphology. Although our choice of parameters yields small desorption rates (<3%), we observe a dramatic change in the singularity spectrum, which is shifted toward smaller Holder exponents. Our results offer a mathematical foundation of anomalous scaling: We identify the global exponent alpha(g) with the Holder exponent that maximizes the singularity spectrum.

Journal Article↗

[Computer-assisted visualization of digital mammography images].

PURPOSE: In a clinical study, the feasibility of using a mammography workstation for the display and interpretation of digital mammography images was evaluated and the results were compared with the corresponding laser film hard copies. MATERIALS AND METHODS: Digital phosphorous plate radiographs of the entire breast were obtained in 30 patients using a direct magnification mammography system. The images were displayed for interpretation on the computer monitor of a dedicated mammography workstation and also presented as laser film hard copies on a film view box for comparison. The images were evaluated with respect to the image handling, the image quality and the visualization of relevant structures by 3 readers. RESULTS: Handling and contrast of the monitor displayed images were found to be superior compared with the film hard copies. Image noise was found in some cases but did not compromise the interpretation of the monitor images. The visualization of relevant structures was equal with both modalities. Altogether, image interpretation with the mammography workstation was considered to be easy, quick and confident. CONCLUSIONS: Computer-assisted visualization and interpretation of digital mammography images using a dedicated workstation can be performed with sufficiently high diagnostic accuracy.

Aged↗

Receiver operating characteristics of perceptrons: influence of sample size and prevalence.

In many practical classification problems it is important to distinguish false positive from false negative results when evaluating the performance of the classifier. This is of particular importance for medical diagnostic tests. In this context, receiver operating characteristic (ROC) curves have become a standard tool. Here we apply this concept to characterize the performance of a simple neural network. Investigating the binary classification of a perceptron we calculate analytically the shape of the corresponding ROC curves. The influence of the size of the training set and the prevalence of the quality considered are studied by means of a statistical-mechanics analysis.

Biophysical Phenomena↗

Spontaneous reinitiation of atrial fibrillation following transvenous atrial defibrillation.

Spontaneous reinitiation of atrial fibrillation (AF) has not been systematically looked at in patients undergoing transvenous AF. This study involved 11 patients, the mean age 60 +/- 8 years, 3 male and 8 female, in whom transvenous atrial defibrillation successfully converted AF to sinus rhythm. Eight patients had paroxysmal AF and three patients had chronic persistent AF for 4 weeks or more. Four patients were taking antiarrhythmic medications at the time of testing. Multipolar transvenous catheters were positioned inside the coronary sinus, right atrium, and the right ventricle. Atrial defibrillation testing was performed using the METRIX atrial defibrillation system in nine patients and the Ventritex HVSO2 in the remaining two patients. A total of 64 therapeutic shocks (range 3-11) were delivered in the 11 patients, and 31 of these successfully converted AF to sinus rhythm. In four patients spontaneous AF was reinitiated following 12 successful transvenous atrial defibrillation episodes. The mean time to reinitiation of AF following shock delivery and restoration of sinus rhythm was 8.26 +/- 5.25 seconds, range 1.8-19.9 seconds. All 12 episodes of spontaneous AF were preceded by a spontaneous premature atrial complex. The coupling interval of the premature atrial complexes was 443 +/- 43 ms, range 390-510 ms. None of the patients taking antiarrhythmic medications or those demonstrating no premature atrial complexes had spontaneous reinitiation of AF. In conclusion, spontaneous reinitiation of AF can occur in a significant proportion of patients with AF undergoing transvenous atrial defibrillation. This phenomenon is preceded by the occurrence of atrial premature complex. Findings of this study may have significant clinical implications.

Adult↗

Ventricular tachycardia in valvular heart disease: facilitation of sustained bundle-branch reentry by valve surgery.

BACKGROUND: The clinical characteristics of sustained monomorphic ventricular tachycardia (SMVT), when it develops after valve surgery, have not been described. METHODS AND RESULTS: Between 1985 and 1996, 31 patients (30 men and 1 woman) who had undergone valve surgery were found to have inducible SMVT. Nine patients (29%) had sustained VT due to bundle-branch reentry (BBR) (group 1). Four of these patients had normal left ventricular function, and VT with a right bundle-branch morphology was inducible in 4 patients. Group 2 included 20 patients with inducible myocardial (ie, non-BBR) VT. Coronary artery disease was present in 15 group 2 patients (75%) due to atherosclerotic (n=12) and nonatherosclerotic (n=3) causes. Two patients had both inducible sustained BBR and myocardial VT (group 3). Sustained BBR VT occurred significantly earlier after valve surgery (median, 10 days) than the onset of postoperative myocardial VT (median, 72 months; P<.005). CONCLUSIONS: Myocardial VT was the most common type of inducible SMVT in patients with valvular heart disease. The majority of these patients had underlying coronary artery disease and significant left ventricular dysfunction. However, in almost one third of the patients, sustained BBR VT was the only type of inducible SMVT. This type of VT was facilitated by the valve procedure occurring within 4 weeks after surgery in most patients. In these patients, left ventricular function was relatively well preserved, and the right bundle-branch block type of BBR was frequently induced. Because a curative therapy can be offered to these patients (ie, bundle-branch ablation), BBR should be seriously considered as the mechanism of VT in patients with valvular heart disease, particularly if the arrhythmia occurs soon after valve surgery.

Adult↗

Efficacy of the implantable cardioverter-defibrillator in the elderly.

OBJECTIVES: We sought to assess the effect of advanced age on the outcome of patients with an implantable cardioverter-defibrillator (ICD). BACKGROUND: ICDs are effective in preventing sudden cardiac death in susceptible patients, but their beneficial effect on survival is attenuated by the high rate of nonsudden cardiac death in those treated. Although advanced age is an important variable in determining cardiovascular mortality, its impact on the outcome of patients with an ICD has been inadequately studied. METHODS: We performed multivariate analysis of a data base consisting of 769 consecutive patients with an ICD. Seventy-four patients > or = 75 years old at ICD implantation (Group 1) were compared with the remaining 695 patients (Group 2). RESULTS: The two groups were similar in clinical presentation, left ventricular function and gender distribution. The mean follow-up time was 29 and 42 months, respectively, for patients in Group 1 and Group 2. Actuarial survival at 4 years was 57% in Group 1 versus 78% in Group 2 (p = 0.0001). This difference was primarily due to a higher rate of nonsudden cardiac death in Group 1. On multivariate analysis, age > or = 75 years, New York Heart Association functional class III, left ventricular ejection fraction < 30% and appropriate shocks during follow-up were independently associated with increased mortality (odds ratio 3.56, 1.8, 1.6 and 1.39, respectively). CONCLUSIONS: Among patients with similar functional class and ejection fraction, the mortality risk is increased threefold in those > or = 75 years old at the time of ICD implantation. Extrapolation of results from younger patients is likely to overestimate ICD benefit in the elderly.

Age Factors↗

The effect of biphasic waveform tilt in transvenous atrial defibrillation.

Atrial defibrillation can be accomplished using low energy shocks and transvenous catheters. The biphasic waveform tilt required to achieve optimal atrial defibrillation thresholds (ADFTs) is, however, not known. The effect of single capacitor biphasic waveform tilt modification on ADFT was assessed in 20 patients. Following AF induction the defibrillation pulses were delivered between the catheters positioned in the coronary sinus and the right atrium. The single capacitor biphasic waveform shocks, delivered over the same pathways, consisted of 65% tilt (65/65 biphasic waveform) to produce an overall tilt of 88%, or 50% tilt (50/50 biphasic waveform) to produce an overall tilt of 75%. Although 65/65 biphasic waveform delivers more energy, the shorter duration 50/50 biphasic waveform reduced stored energy ADFT 21%, from 1.34 +/- 0.82 J with 65/65 biphasic to 1.06 +/- 0.81 J. These differences were not statistically significant. Nine patients had lower ADFT with 50/50 biphasic waveform while five patients had lower ADFT with 65/65 biphasic waveform. Equivalent reduction in ADFT was seen in the remaining six patients. The ADFT was 0.83 +/- 0.65 J when both tilts were considered. In conclusion, biphasic waveform tilt modification may affect the ADFT in an individual patient. The optimal biphasic waveform for ADFT is not known.

Adult↗

The effect of polarity of the initial phase of a biphasic shock waveform on the defibrillation threshold of pectorally implanted defibrillators.

The effect of initial phase polarity on the DFT of two pectorally implanted biphasic ICDs was tested in a randomized, prospective manner at the time of implantation. Twenty-two consecutive patients with VT-VF who received either the Medtronic PCD 7219C Jewel device (10 patients) or PCD 7219D Jewel device (12 patients) were studied. DFT testing was performed in a standard step-down manner. Both initial phase polarities--initial defibrillation current flowing from active can/SVC coil +/- subcutaneous patch) to the RV coil (RV coil to active can/SVC (RV+)--were tested in random order. The mean DFT achieved with RV+ compared with RV-was lower for the 7219C patient group (6.6 +/- 3.1 vs 10.8 +/- 5.5 J; P = 0.007). A similar trend was observed for the 7219D group, though the difference did not reach statistical significance (12.0 +/ 4.0 vs 16.3 +/- 7.3 J; P = 0.07). Seven of the 10 patients in the 7219C group had a lower DFT with RV+, while the initial phase polarity made no difference in 3. In the 7219D group, 7 patients had a lower DFT using RV+, 2 patients had a lower DFT using RV-, and the initial phase polarity made no difference in 3. In conclusion, this study demonstrates that changing the polarity of the initial phase of a biphasic shock waveform can have a significant impact on the DFT achieved at the time of ICD implantation.

Aged↗

Efficacy of midodrine hydrochloride in neurocardiogenic syncope refractory to standard therapy.

INTRODUCTION: Some patients with neurocardiogenic syncope continue to have recurrent syncope or presyncope despite the use of currently available drug therapy. The purpose of this study was to determine whether midodrine hydrochloride, a selective adrenergic agonist, could be effective in patients resistant to, or intolerant of, currently used medications in the treatment of neurocardiogenic syncope. METHODS AND RESULTS: Eleven patients with a history of recurrent syncope or presyncope in whom hypotension with syncope or presyncope could be provoked during head-up tilt testing were included. There were 4 men and 7 women with a mean age (+/-SD) age of 34 +/- 13 years. In all patients, standard therapy with beta-adrenergic receptor blocking agents, ephedrine, theophylline, disopyramide, fludrocortisone, and sertraline hydrochloride, was either ineffective, poorly tolerated, or contraindicated. Midodrine was initially administered orally at a dose of 2.5 mg three times daily. After adjustment of dosage over 2 to 4 weeks, patients were followed-up clinically. Midodrine was discontinued in one patient because of side effects. Frequency of syncope or presyncope during the 3 months prior to starting treatment was compared during a mean follow-up of 17 +/- 4 weeks after starting treatment with midodrine. There was significant (P < 0.01) reduction in syncopal and presyncopal episodes on midodrine. Five patients had complete resolution of symptoms, while four patients had significant improvement. Symptoms did not improve in one patient. CONCLUSIONS: Midodrine hydrochloride can be effective in preventing recurrent symptoms in selected patients with neurocardiogenic syncope unresponsive to, or intolerant of, standard drug therapy.

Administration, Oral↗

Delivery of noncommitted shocks for nonsustained ventricular arrhythmias by a new implantable cardioverter defibrillator with abortive shock capability.

INTRODUCTION: To describe the delivery of noncommitted implantable cardioverter defibrillator (ICD) shocks despite self-termination of ventricular arrhythmias. Abortive shock capability should eliminate the delivery of shocks for self-terminating ventricular arrhythmias. The delivery of noncommitted shocks despite abortive shock capability is, therefore, unexpected and previously unreported. METHODS AND RESULTS: Among 118 patients who received the Transvene nonthoracotomy lead system and the Jewel ICD (model 7219D), three patients (1.7%) experienced supurious, noncommitted shocks for self-terminating arrhythmias. Only one detection zone (i.e., ventricular fibrillation) had been programmed in the defibrillator in each patient. In all three patients, the ventricular arrhythmias self-terminated during the charging period. One patient received seven shocks during periods of asystole, and the other two patients received one shock each. Two different mechanisms for shock delivery in this setting were identified: one occurring in the absence of electrical activity at the end of the bradycardia escape interval (i.e., associated with bradyarrhythmias), and the other when two sensed electrical events (i.e., escape beats) occurred during the so-called "synchronization" window of the defibrillator. CONCLUSIONS: In rare patients with the Jewel defibrillator, shocks may be delivered for self-terminating arrhythmias despite abortive shock capability. Patients who are dependent upon pacing from their implanted defibrillator are at particular risk for shock in the aftermath of self-terminating ventricular arrhythmias. Defibrillator programming strategies aimed at eliminating or diminishing the incidence of this problem are discussed.

Aged↗

Feasibility of atrial fibrillation detection and use of a preceding synchronization interval as a criterion for shock delivery in humans with atrial fibrillation.

OBJECTIVES: This study assessed the feasibility of detecting atrial fibrillation (AF) and delivery of appropriately timed R wave shocks using an implantable atrial defibrillator. BACKGROUND: For atrial defibrillation therapy to be feasible in an implantable form, AF must be detected in a specific fashion, and the risk of ventricular proarrhythmia should be minimized. METHODS: Eleven patients with AF underwent testing with an implantable atrial defibrillator (METRIX 3000 Automatic Atrial Defibrillator, InControl, Inc.). Wideband electrograms (EGMs) were recorded from the right ventricular (RV) bipolar catheter and from the multipolar catheters located in the right atrium (RA) and coronary sinus (CS). Atrial fibrillation detection was performed using two serial algorithms-quiet interval analysis and baseline crossing analysis-that detect atrial activity on the RA-CS channel. Ventricular sensing using a minimal preceding synchronization interval of 500 ms as a criterion for synchronous shock delivery was performed from filtered RV and RV-CS EGMs. RESULTS: The AF detection algorithms were applied to 53 AF data segments and 18 normal sinus rhythm data segments. Atrial fibrillation was detected appropriately in 49 instances, and the specificity for detecting AF and normal sinus rhythm was 100%. Synchronization criterion efficacy was assessed by delivering shock markers and shocks. Of the 2,025 R waves processed, 557 (27.5%) were marked as suitable for shock delivery. In addition, 69 therapeutic and 11 test shocks were delivered during AF. All shock markers and shocks were delivered synchronously with the R wave, and the synchronization criterion was never violated. CONCLUSIONS: Atrial fibrillation can be detected in a specific fashion using the RA-CS lead configuration and serial detection algorithms for atrial sensing. The delivery of properly timed shocks is feasible and should minimize the risk of ventricular proarrhythmia.

Adult↗

Unmasking the trifascicular left intraventricular conduction system by ablation of the right bundle branch.

Twenty-five patients underwent transcatheter right bundle ablation either for bundle branch reentrant tachycardias or inadvertent or deliberate right bundle ablation during atrioventricular junctional ablation for rate control. Electrophysiologic data and 12-lead electrocardiograms before and after right bundle ablation were available in all patients. Eleven of the patients had no significant intraventricular conduction abnormalities by surface electrocardiograms (group I), whereas 14 patients had underlying intraventricular conduction delays (group II). All group I patients had typical electrocardiographic changes of right bundle branch block after right bundle ablation, with minimal changes in initial or mean QRS axis. In group II, 5 patients had an initial 40 ms QRS axis shift of > 45 degrees, in 7 patients the mean QRS axis changed significantly (leftward in 4 and rightward in 3), and a qR pattern in V1 was seen in 12 of 14 patients including 2 with structurally normal hearts. These changes, namely new Q waves, and rightward and leftward axis shifts are most likely the result of septal fascicular, left posterior fascicular, and left anterior fascicular delay/block, which were exposed by exclusive conduction via a diseased left bundle and its fascicles. The trifascicular nature of left intraventricular conduction is more apparent when diseased and unmasked by concomitant block in the right bundle branch.

Aged↗

Distribution of atrial electrogram types during atrial fibrillation: effect of rapid atrial pacing and intercaval junction ablation.

OBJECTIVES: This study examined the anatomic distribution types and possible determinant of atrial electrogram types during atrial fibrillation. BACKGROUND: Different types of atrial electrograms during atrial fibrillation have been observed and classified, but their anatomic distribution patterns, determinants and potential usefulness in guiding future catheter ablation are unknown. METHODS: Two animal models of atrial fibrillation were used: the sterile pericarditis model (n = 10) and the rapid atrial pacing model (400 beats/min for 6 weeks, n = 6). The atrial electrogram of atrial fibrillation and the atrial effective refractory period were obtained from multiple sites of the right and left atrium. In addition, decremental rapid atrial stimulation was applied to the site of shortest and longest atrial effective refractory periods until atrial fibrillation induction in a subgroup of nine dogs. Ablation of the intercaval junction was performed using the radiofrequency catheter technique in dogs with atrial fibrillation duration > 1 min. RESULTS: In both models, organized atrial electrograms (type I) were predominantly observed at the left atrial sites and the right atrial appendage, whereas disorganized atrial electrograms (type III) were mainly observed at the right posterolateral atrium. The distribution of the atrial electrogram types closely followed that of the atrial effective refractory period, with the shortest atrial effective refractory period corresponding to organized atrial electrograms (type I) and the longest atrial effective refractory period corresponding to disorganized atrial electrograms (type III). The correlation of atrial electrogram type with the atrial effective refractory period was further demonstrated by the effect of rapid atrial stimulation. When rapid atrial stimulation was applied to the site with the shortest atrial effective refractory period, disorganized atrial electrograms were observed at sites with the longest atrial effective refractory period, whereas 1:1 atrial capture was still present at the stimulation site. Ablation of the intercaval junction made atrial fibrillation noninducible or tended to shorten the atrial fibrillation duration (from 26.4 +/- 24.2 to 8.8 +/- 22.6 min in the pericarditis group, p = 0.02, and from 33.7 +/- 29.2 to 12.1 +/- 23.8 min in the rapid pacing group, p = 0.09) but did not change the atrial electrogram types during atrial fibrillation. CONCLUSIONS: Various types of atrial electrograms are present at different locations during atrial fibrillation. The atrial electrogram characteristics of atrial fibrillation at a specific location are related to the atrial effective refractory period, with short effective refractory periods associated with organized atrial electrograms and long effective refractory periods associated with disorganized electrograms.

Animals↗

Sudden death in patients with implantable cardioverter-defibrillators.

UNLABELLED: Of the 733 patients with implantable cardioverter-defibrillators (ICDs) from 1982 to 1995 in our center, 20 died suddenly while the ICD was activated. This number included 16 men and four women with a mean age of 60 +/- 8 years and ejection fractions of 24.2% +/- 8.6%. ICDs were implanted for drug refractory ventricular tachycardia (VT) in 13 patients and for resucitated cardiac arrest in seven patients. The clinical VT was associated with syncope in 7 of 13 patients. VT was induced in 18 patients and was hemodynamically unstable in 12 patients. Shock therapies associated with syncope were delivered in 7 of 15 patients during the follow-up. This subgroup of patients survived a median of only 18 months after ICD implant. Ventricular fibrillation-defibrillation was found to surround death in nine patients. CONCLUSIONS: (1) Sudden death victims of the ICD population are characterized by poor left ventricular function and hemodynamically unstable ventricular tachyarrhythmias. (2) Ventricular tachyarrhythmias are the major cause of sudden death in ICD patients.

Aged↗