Diagnostic performance of two-dimensional versus three-dimensional transesophageal echocardiographic images of selected pathologies evaluated by receiver operating characteristic analysis.

UNLABELLED: The sensitivity and specificity of 2-D and 3-D echocardiographic images for the detection of selected morphological abnormalities were compared using receiver operating characteristic (ROC) analysis. Five experienced clinical echocardiographers blinded to the patients' diagnoses evaluated the 20 original static 2-D image sets and 20 corresponding 3-D reconstructions using a five point categorical scale that ranged from definitely abnormal to definitely normal. The ROC curve for the 3-D images was significantly (P < 0.05) closer to the ideal discrimination function than was the ROC curve for the 2-D transesophageal images (i.e., the sensitivity of the 3-D images was higher than that of the 2-D sequential images at the same specificity). IN CONCLUSION: 3-D transesophageal images provided better visual clues for the identification of morphological abnormalities than did serial 2-D echocardiographic images despite the same input information in both image formats. The use of ROC analysis assisted in the comparison of these two imaging techniques.

Adolescent↗

Three-dimensional ultrasound imaging of the atrial septum: normal and pathologic anatomy.

OBJECTIVES: This study investigated the feasibility of producing three-dimensional gray scale ultrasound images of the atrial septum to demonstrate normal and pathologic anatomy. BACKGROUND: Two-dimensional echocardiography is the principal technique used for imaging the atrial septum. Although the diagnostic accuracy of two-dimensional echocardiography is high, its capability for displaying complex three-dimensional relations is limited. METHODS: Three-dimensional ultrasound images were reconstructed from tomographic images obtained during routine transesophageal echocardiographic examinations. Custom-made semi-automatic algorithms for image enhancement, interpolation and segmentation were used to produce volumetric gray scale images. Volume-rendered displays of the atrial septum were generated for analysis. Sequential three-dimensional images were generated through the cardiac cycle and displayed cinematographically to permit assessment of motion. RESULTS: The three-dimensional images obtained from six patients clearly demonstrated normal and pathologic anatomy of the atrial septum, including atrial septal defects, atrial septal aneurysm and aortic valve ring abscess. The images could be manipulated electronically to demonstrate spatial relations and internal structural details. CONCLUSIONS: Three-dimensional gray scale reconstruction of ultrasound images obtained by transesophageal echocardiography is feasible. These images clearly demonstrate anatomic details and spatial relations. The gray scale images may be interactively manipulated to optimize the clinician's visualization of the atrial septum and its associated pathologic conditions.

Cardiomyopathies↗

Multidimensional visualization in echocardiography: an introduction.

X-ray films depict three-dimensional objects as shadows in a two-dimensional plane; thus, objects become superimposed. Computed tomography and other types of tomographic imaging, such as ultrasonography, acquire two-dimensional images of a material property within a thin slice. Sequential adjacent two-dimensional tomograms can be used to construct three-dimensional displays of objects. Visualization, a field of computer science, enables scientists to measure image attributes (extraction of features), identify features (classification), separate objects from one another (segmentation), and produce comprehensible, information-dense images from three-dimensional data sets (rendering). A three-dimensional rendering of the heart can be used to represent only one component of the heart, such as the atrial septum or the ventricular chamber, and can be shaded or colored to enhance comprehension. Three-dimensional images rendered sequentially over time result in a dynamic four-dimensional display. This report describes multidimensional visualization of objects and tissues and specifically discusses examples from echocardiography.

Echocardiography↗

Three- and four-dimensional cardiovascular ultrasound imaging: a new era for echocardiography.

Three-dimensional and four-dimensional ultrasonography were pioneered in the 1960s yet have been used little clinically. Only recently have advances in cardiovascular ultrasound equipment and in digital image storage, manipulation, and display techniques made three- and four-dimensional imaging clinically feasible. In this report, we review the historical development of these technologies during 3 decades to their culmination in current state-of-the-art technology. Examples of such multidimensional images are presented, with special emphasis on clinical applications. Although several limitations persist, three-dimensional cardiovascular ultrasonography seems likely to enhance imaging of the heart and vessels in a manner similar to the advent of two-dimensional echocardiography in the M-mode era. Clinician-scientists will soon be able to extract an object, such as the heart, from the body electronically for the purpose of anatomic, functional, and histologic analysis without adverse effect on the patient.

Echocardiography↗

Three-dimensional reconstruction of color Doppler jets in the human heart.

A computer algorithm has been developed for segmentation and three-dimensional (3D) reconstruction of Doppler color-flow images. The algorithm enables the user to select a range of velocities, represented by colors, for segmentation and subsequent 3D reconstruction. The reconstructed flows are assigned a color palette and merged with the volume-rendered gray-scale image to produce a 3D image containing both flow and anatomic information. The results demonstrate the application of the algorithm to regurgitant and shunt jets with complex spatial and velocity patterns. We conclude that 3D reconstruction of selected color spectra (e.g., velocities) of Doppler color flows and surrounding anatomy is feasible in the clinical setting.

Algorithms↗

[Phalloidin suppresses the force in nebulin-rich lamprey cardiac muscle].

The effect of phalloidin, an agent detaching nebulin from actin in skeletal muscle, on the isometric force in lamprey skinned cardiac muscle, which has nebulin in amounts comparable to that in skeletal muscle, has been studied. We found that, unlike mammalian cardiac muscle expressing nebulin less abundantly and responding to phalloidin by a force increase, lamprey cardiac muscle responds to phalloidin by a force decrease (approximately 50% decrease), thereby resembling the response of skeletal muscle. These results support our hypothesis that nebulin detachment from actin underlies phalloidin-induced force loss and suggest a role of actin-nebulin interaction in contractile function.

Animals↗