Search PubMed⌕ Search

Biomedical subjects

M Baldassarri

Publications and source records attributed to M Baldassarri.

8 recordsLinked to original sources

A versatile mechanical ventilator (DIGIT) with high flow stability and a programmable inspiratory phase flow pattern.

The paper describes the general characteristics of a newly developed nonconstant-flow generator for automatic ventilation of the lungs. It is known that the application of very high pressure to high internal resistance leads to a very stable flow, in that the flow itself is unaffected by external load (patient) variations. The stability of the flow means that the inspiratory process can be controlled by means of the ventilated volume, thus extending DIGIT utilization to high resistance patients. The modulation of the flow is implemented via a digital electromechanical system, which allows the ventilator functions to be accurately programmed. The desired flow waveform is obtained by means of a series of pneumatic valves, the apertures of which are digitally controlled. The design is innovative in that it allows the flow waveform in each of the ten digitalized time steps into which each inspiratory phase is divided to be both programmed and controlled. Other ventilators commercially available and currently in use do not have this functional capability, as they are all designed to model the integral flow of the inspiratory waveform without being able to modify the subunit time steps of a single inspiratory phase. The paper also discusses the results of fundamental tests concerning the performance characteristics of the ventilator.

Airway Resistance↗

Bone marrow transplantation in a thalassemia patient with congenital heart disease.

We report a thalassemia patient suffering from congenital transposition of the great arteries, surgically corrected according to Mustard technique at the age of 4 months, who underwent bone marrow transplantation. Despite a syncopal episode occurring during the first day after marrow infusion the transplant was successful. Thirty-two months later, normalization of hematologic parameters was observed together with a substantial improvement in cardiac function.

Bone Marrow Transplantation↗

Needle liver biopsy in thalassaemia: analyses of diagnostic accuracy and safety in 1184 consecutive biopsies.

We report the reliability and safety of percutaneous liver biopsy in the evaluation of hepatic iron loading and histology in patients with homozygous beta-thalassaemia prior to and in serial biopsies following allogeneic bone marrow transplantation for this disorder. 501 thalassaemic patients aged 11 +/- 4.5 years (range 1-32 years) underwent 1184 consecutive percutaneous liver biopsies without ultrasound guidance. Overall, 81% of biopsies were evaluable for histological examination and grading of iron. The adequacy of liver biopsy specimens increased with patient age: evaluable specimens were obtained in 73% of patients < 5 years of age and in 86% of samples in patients aged > 15 years. The degree of iron overload and fibrosis in each biopsy was reported separately by at least two pathologists who did not know the clinical status of each patient. In 103 biopsies, iron grade by light microscopy corresponded to an iron concentration varying between a mean of 32.46 +/- 14 mumol/g dry weight liver tissue for iron stores graded by light microscopy as absent to 417.6 +/- 150 mumol/g dry weight liver tissue for stores graded as severe. The fibrosis score of multiple samples of liver obtained at autopsy within 100 d of the percutaneous biopsy in 41 patients who died following BMT correlated perfectly with that of the first sample in > 60% biopsies; in most of the discordant cases fibrosis had been underestimated in the percutaneous biopsy. Liver biopsy demonstrated evidence of chronic hepatitis in 30% of patients with normal transaminase and in 57% of patients with transaminase within twice the normal range. Liver biopsy was complicated in six patients (0.5%) by haemoperitoneum, periocholecystic haematoma, kidney haematoma, or bile peritonitis; no complication was fatal. These data demonstrate that percutaneous liver biopsy provides reliable information regarding liver iron and histology in homozygous beta-thalassaemia with an extremely low risk of complications.

Adolescent↗

Cardiac tamponade in thalassemia.

We report a case of acute cardiac tamponade without concurrent myocardial disease occurring in a thalassemia patient early after bone marrow transplantation. The pericardial effusion was preceded by an episode of junctional tachycardia. Repeated evaluation by echocardiography was done shortly after the patient developed the arrhythmia and permitted a detailed, timed observation of the event and description of the symptoms.

Bone Marrow Transplantation↗

[An information survey on the automatic operation of intensive therapy units in Italy].

A fact finding study was carried out in 58 resuscitation centres and 78 intensive care units to evaluate the current application of computerised techniques in the monitoring and processing of various parameters relating to hospitalised patients. The enquiry revealed a marked interest in the use of computerised systems, particularly in the electrophysiological and haemodynamic field. Promising results were reported from some centres. Some adverse criticisms and points of discussion still exist. International and national experiences matured so far, however, while primarily directed towards scientific research and technological development, open up significant perspectives for the future, for the rational handling of the data collected, and the extension of current knowledge on matters of physiopathology, electrophysiology, and pharmacokinetics.

Computers↗