Search PubMed⌕ Search

Biomedical subjects

M B Wolf

Publications and source records attributed to M B Wolf.

At least 37 records · Page 2Linked to original sources

Integral-mass balance method for determination of solvent drag reflection coefficient.

We have developed the integral-mass balance (IMB) method to measure the solvent drag reflection coefficient (sigma f) for transcapillary macromolecular transport in skeletal muscle and other organs. Of course, sigma f is calculated from the cumulative amounts of water and macromolecule that move convectively across the microvascular membrane as determined from changes in hematocrit and plasma macromolecule concentration over a period of fluid filtration. We have investigated the effects of both theoretical and experimental factors that affect the validity and accuracy of the method. The effect of the following factors on sigma f determination by the IMB method were explored: low Peclet number; random-measurement errors; and systematic errors due to vascular leakage, hemolysis of red blood cells, evaporation, and osmolality changes. We found that all of these factors produced overestimations of sigma f, but their effects could be corrected. Also, appropriate experimental design could minimize these effects. Experiments using the IMB method in the isolated, perfused cat hindlimb preparation to determine sigma f for albumin and plasma proteins resulted in mean values of 0.82 +/- 0.08 (SD) (n = 7) and 0.83 +/- 0.02 (n = 4), respectively.

Animals↗

Dextran and capillary filtration coefficient in cat hindlimb.

To investigate the possible mechanisms through which dextran modifies capillary filtration coefficient (CFC), the effects of perfusion with a protein-free dextran solution were compared with those of perfusion with a Ringerlike solution. With the use of the isolated cat hindlimb, CFC was measured during perfusion at constant flow with three solutions, a control blood-albumin mixture, a Ringerlike solution called dialysate, and 3.7 g/dl dextran dissolved in dialysate. The solutions were warmed to 37-38 degrees C, bubbled with 95% O2-5% CO2, and contained 0.015 g/dl or more papaverine. CFC was calculated from the rate of limb weight gain following a step increase in venous pressure. Dextran perfusion increased CFC to 2.0 +/- 0.2 (SD, n = 8) times control, which was significantly less (P less than 0.001) than 3.1 +/- 0.6 (n = 8) times control previously reported for dialysate perfusion. The difference between the measured viscosity of dextran (1.35 cP) and dialysate (0.72) could account for this reduction. However, when a dialysate perfusion followed a dextran perfusion, CFC only increased to 2.3 +/- 0.4 (n = 8) times control. This value is also significantly less (P less than 0.01) than 3.1. This observation suggests 1) that dextran is retained within the transcapillary channel and 2) that dextran reduces CFC mainly by partially blocking the transcapillary channel rather than by increasing viscosity.

Animals↗

Effect of temperature on transcapillary water movement in isolated cat hindlimb.

Capillary filtration coefficient (CFC) was measured in the isolated cat hindlimb preparation, perfused at 20 ml X min-1 X 100 g muscle-1 with a perfusate containing 6 g/dl albumin and normal electrolyte concentrations, to which were added 50 ml of the cat's blood and 6 micrograms of the vasodilator isoproterenol. CFC was determined three to six times in an initial control period during which the tissue temperature (measured by a 5-mm disk thermistor implanted in a thigh muscle) was controlled near 37 degrees C. Tissue temperature was decreased to 5-10 degrees C by lowering perfusate and ambient air temperatures. About 50 min were required for tissue temperature equilibration. CFC was measured at low temperature and then again at 37 degrees C. For nine experiments, the ratio of CFC at low temperature to that in the 37 degrees C control periods averaged 87% of the ratio of water viscosity at 37 degrees C to that at low temperature. The activation energy for water calculated from these data was 5.0 kcal/mol. These results may be explained by all transcapillary water flow moving by diffusion through narrow pores or by about 90% moving by convection, with the remainder going through a lipid pathway. However, the results may be entirely due to a direct effect of temperature on the geometry of the transcapillary pathway for water movement.

Animals↗

Control of transcapillary water movement by vasoactive agents.

Experiments were performed to demonstrate that papaverine can increase capillary filtration coefficient, CFC, and to investigate whether this increase could be reversed by isoproterenol, norepinephrine and plasma. The study used the isolated cat hindlimb, perfused at constant flow with a recirculated blood-albumin solution. It was observed that papaverine increased CFC in a dose-dependent manner, and that this effect could be reversed by isoproterenol and norepinephrine. Norepinephrine reduced CFC even in the presence of phentolamine. Plasma, previously shown to reduce CFC when papaverine was present, was shown to have no such effect when papaverine was absent. It is argued that the CFC changes are best explained by changes in the hydraulic conductivity of the exchange vessels, rather than through changes in the perfused surface area, and that the CFC changes are similar to the permeability changes caused by inflammatory mediators and catecholamines observed by others.

Animals↗

Anoxia and capillary filtration coefficient in the isolated cat hindlimb.

Isolated cat hindlimbs were perfused from a reservoir with an albumin-blood mixture at a constant flow of 20 ml X min-1 X 100 g muscle-1 while alternately bubbling the perfusate with either 95% O2-5% CO2 gas mixture or a 95% N2-5% CO2 mixture for 50- to 60-min periods. Capillary filtration coefficient (CFC), vascular resistance (R), and perfusate O2 content were measured in each period. The arterial O2 content fell from fully equilibrated to 0.25 vol% during the use of N2. R fell from about 6 mmHg X min X 100 g X ml-1 during O2 bubbling to approximately 1.0 with N2. CFC averaged 0.012 +/- 0.002 ml X min-1 X mmHg-1 X 100 g muscle-1 (SD, n = 6) during the 1st O2 period, rising to 0.016 +/- 0.002 (n = 4) in the 3rd O2 period 4 h later. CFC fell by 5% (P less than 0.001) during the periods of N2 bubbling. Papaverine was present in two experiments without effect on the CFC data. It was concluded that CFC was not meaningfully influenced by vascular resistance or anoxia, a finding that is inconsistent with the concept of local metabolic control of CFC by precapillary resistance vessels.

Animals↗

Estimation of whole-body capillary transport parameters from osmotic transient data.

A mathematical model has been developed of short-term, extrarenal, whole-body fluid volume regulation. The Kedem and Katchalsky equations are used to describe rapid movements of crystalloid and colloid solutes and water between five fluid compartments. Simulation results showing rapid cell volume changes following a hyperosmotic crystalloid infusion demonstrated the necessity of considering the effect of cellular water shifts in osmotic transient experiments. From measurements of plasma volume and osmolality in acutely nephrectomized dogs subjected to isosmotic and hyperosmotic NaCl infusions and with the model, six parameters related to capillary membrane transport of water and NaCl were estimated. The mean capillary filtration capacity from six experiments was estimated as 0.01 ml.min-1.mmHg-1.100 g-1 of dog. This increased about threefold due to the hyperosmolality. Mean values of capillary diffusion capacity and osmotic reflection coefficient for NaCl were 0.37 cm3.s-1.100 g-1 and 0.087, respectively. These results support the use of the osmotic transient approach and a mathematical model to study the role of microvascular transport in whole-body fluid volume regulation.

Animals↗

Dynamic palatometry.

A computer-based instrumental system is described for continuous palatometry. Thin pseudopalatal plates (approximately 0.2 mm) with embedded electrodes are used to detect linguapalatal contact during speech articulation. Geometric configurations of such contacts are then derived and displayed to reveal articulatory characteristics.

Computers↗