Search PubMedSearch

Biomedical subjects

M B Simson

Publications and source records attributed to M B Simson.

At least 19 recordsLinked to original sources

Inappropriate pauses during bradycardia pacing in a third-generation implantable cardioverter defibrillator.

Many ICD devices have the capability for back up bradycardia pacing. Because of the use of a single sensing algorithm for both bradycardia and tachycardia functions, they may be prone to certain "sensing errors." Following implantation of an ICD in a patient with long QT syndrome, "inappropriate" pauses were noted during bradycardia pacing, which were exactly twice the programmed pacing cycle length. This was due to an automatic increase in the device's sensitivity during pacing, a characteristic of the automatic gain control of this particular ICD. Proper recognition of this ICD's special features, known as "lower threshold crossing," allowed noninvasive rectification of the problem and prevented these pauses.

Aged

Nighttime dosing assures postdistribution sampling for therapeutic drug monitoring of digoxin.

To study the appropriateness of phlebotomy for digoxin therapeutic drug monitoring (TDM) in outpatients, we conducted a retrospective chart review, a computer search of all previous TDM testing, and a questionnaire of all outpatients (n = 86) who had serum digoxin determinations between April 10 and April 28, 1992 (585 tests). In patients who took digoxin at the same time daily (40 patients, 300 tests), 52% of tests were performed on inappropriate samples drawn within 6 h of the last dose. No patient who took digoxin after 1700 had inappropriate tests. Phlebotomy for serum digoxin determinations before distribution of digoxin is complete is a common problem in outpatients, leading to clinically uninterpretable test results. Postdistribution sampling can be assured by nighttime dosing, and this recommendation has been implemented at our hospital.

Adult

Prognostic value of an abnormal signal-averaged electrocardiogram in patients with nonischemic congestive cardiomyopathy.

BACKGROUND: An abnormal signal-averaged ECG (SAECG) has predictive value for arrhythmic events in patients with coronary artery disease. The purpose of this study was to investigate whether an abnormal SAECG could provide prognostic information in patients with nonischemic dilated cardiomyopathy. METHODS AND RESULTS: We prospectively obtained SAECGs in 114 patients with dilated nonischemic cardiomyopathy. Twelve-lead ECGs, left ventricular ejection fractions, hemodynamic measurements, and peak exercise oxygen consumption (VO2) also were measured. An SAECG was defined as abnormal by any one of the three following criteria: filtered QRS duration > 120 msec, root-mean-square voltage in the last 40 msec < 20 microV, or duration < 40 microV > 38 msec at 40 Hz. Sixty-six patients had a normal SAECG, 20 patients had an abnormal SAECG, and 28 patients had bundle branch block (BBB). Mean follow-up was 10 +/- 5 months. Age, ejection fraction, peak VO2, pulmonary capillary wedge pressure, and cardiac index were not statistically different among the three groups. Use of antiarrhythmic drugs was similar among the three groups, although patients with BBB had more implantable defibrillators (p < 0.05). The incidence of previous atrial arrhythmias was similar for the three groups. Patients with abnormal SAECG or BBB had more past episodes of sustained ventricular tachycardia and/or sudden death episodes (n = 9) than patients with normal SAECG (n = 1) (p < 0.01). Prospectively, none of the 66 patients with normal SAECG died suddenly or had sustained ventricular arrhythmias. Two deaths occurred from progressive heart failure, and three patients required urgent transplant. In the 20 patients with an abnormal SAECG, four patients had sustained ventricular tachycardia, five patients died suddenly, two patients died from progressive heart failure, and one patient required urgent transplant. In the patients with BBB, four patients had sustained ventricular tachycardia, and four patients required urgent transplant. One-year event-free survival, i.e., absence of ventricular tachycardia and/or death, was 95% in patients with normal SAECG, 88% in patients with BBB, and only 39% in patients with an abnormal SAECG (p < 0.001). Multivariate analysis demonstrated that SAECG and New York Heart Association classification were independent predictors of survival. CONCLUSIONS: Patients with an abnormal SAECG had a statistically significant increase in sustained ventricular arrhythmias and/or death than did patients with a normal SAECG or BBB. This study demonstrates that an abnormal SAECG is a marker of past and future arrhythmic events in patients with nonischemic dilated cardiomyopathy. In contrast, patients with a dilated cardiomyopathy with a normal SAECG have an excellent prognosis with adverse outcome only from progressive heart failure.

Bundle-Branch Block

Late potentials in an ovine model of acute transmural myocardial infarction.

The development of slow conduction during the first hours of acute transmural myocardial infarction (ATMI) was studied by signal-averaged electrocardiograms (SAE) in 19 adult anesthetized sheep. SAEs were recorded before and after intravenous infusions of lidocaine and bretylium were begun and 10, 30, and 60 min after ATMI produced by ligation of the left anterior descending and second diagonal coronary arteries. Four sheep died promptly of ventricular tachyarrhythmias; two others developed sustained ventricular arrhythmias, which precluded additional data. Biphasic changes in QRS duration, root mean square voltage of the terminal 40 ms of the QRS complex, and duration of terminal low-amplitude (less than 30 microV) signal were observed. Peak changes in conduction occurred 30 min after infarction and regressed toward baseline thereafter. At 30 min, all animals developed late potentials, which were defined as signals that exceeded both after-drug QRS duration and duration of terminal low-amplitude signal less than 30 microV by more than two standard deviations. At 60 min, only 3 of 13 (23%) animals had late potentials. Conduction is slowest 30 min after ATMI in sheep but may not be related to development of ventricular arrhythmias. In five of six sheep (83%), ventricular arrhythmias occurred within 15 min of infarction before peak slowing was observed by SAE.

Animals

Noninvasive identification of patients at high risk for sudden cardiac death. Signal-averaged electrocardiography.

Signal-averaged electrocardiography allows the detection of late potentials, which have been associated with delayed and disorganized ventricular activation. This article reviews the technique, describes the findings recorded from patients with ventricular tachyarrhythmias, and assesses the prognostic value of late potentials for ventricular tachyarrhythmias and sudden cardiac death in patients after an acute myocardial infarction. The role of signal-averaged electrocardiography in the evaluation of patients with syncope and cardiomyopathies is also briefly discussed.

Cardiomyopathies

Standards for analysis of ventricular late potentials using high-resolution or signal-averaged electrocardiography: a statement by a task force committee of the European Society of Cardiology, the American Heart Association, and the American College of Cardiology.

Sufficient data are available to recommend the use of the high-resolution or signal-averaged electrocardiogram in patients recovering from myocardial infarction without bundle branch block to help determine their risk for developing sustained ventricular tachyarrhythmias. However, no data are available about the extent to which pharmacological or nonpharmacological interventions in patients with late potentials have an impact on the incidence of sudden cardiac death. Therefore, controlled, prospective studies are required before this issue can be resolved. As refinements in techniques evolve, it is anticipated that the clinical value of high-resolution or signal-averaged electrocardiography will continue to increase.

Analog-Digital Conversion

Standards for analysis of ventricular late potentials using high resolution or signal-averaged electrocardiography. A statement by a Task Force Committee between the European Society of Cardiology, the American Heart Association and the American College of Cardiology.

Sufficient data are available to recommend that the high-resolution or signal-averaged electrocardiogram can be used in patients recovering from myocardial infarction without bundle branch block to help to determine their risk for developing sustained ventricular tachyarrhythmias. However, no data are available regarding the extent to which pharmacologic or non-pharmacologic interventions in patients with late potentials have an impact on the incidence of sudden cardiac death. Therefore, controlled, prospective studies are required before this issue can be definitely answered. As refinements in techniques evolve, it is anticipated that the clinical value of high-resolution or signal-averaged electrocardiography will continue to increase in the future.

Arrhythmias, Cardiac

Standards for analysis of ventricular late potentials using high-resolution or signal-averaged electrocardiography. A statement by a Task Force Committee of the European Society of Cardiology, the American Heart Association, and the American College of Cardiology.

Sufficient data are available to recommend the use of the high-resolution or signal-averaged electrocardiogram in patients recovering from myocardial infarction without bundle branch block to help determine their risk for developing sustained ventricular tachyarrhythmias. However, no data are available about the extent to which pharmacological or nonpharmacological interventions in patients with late potentials have an impact on the incidence of sudden cardiac death. Therefore, controlled, prospective studies are required before this issue can be resolved. As refinements in techniques evolve, it is anticipated that the clinical value of high-resolution or signal-averaged electrocardiography will continue to increase.

American Heart Association

Alterations in the initial portion of the signal-averaged QRS complex in acute myocardial infarction with ventricular tachycardia.

This study was designed to examine 2 hypotheses: that acute myocardial infarction (AMI) alters early cardiac activation measured by signal-averaging; and that the magnitude of abnormality of early activation may be greater in patients with post-AMI ventricular tachycardia (VT). We examined the root-mean square voltage amplitude in 10-ms intervals over the first 80-ms of the signal-averaged QRS complex. Data from 42 healthy volunteers were compared with those from 52 patients with previous AMI (24 anterior) but no VT and 46 post-AMI patients (33 anterior AMI) with recurrent sustained VT. Patients with VT differed from other post-AMI patients because of lower left ventricular ejection fraction, more frequent aneurysm formation and higher levels of ventricular ectopic activity. A significant decrease in initial voltage amplitude occurred at 30 to 40 ms after the beginning of the QRS in both anterior and inferior AMI patients compared with the normal group. A further significant decrease in initial amplitude occurred in VT patients both after anterior and inferior AMI. These differences persisted for the remainder of the 80-ms interval. These changes were weakly related to QRS duration (r = 0.45), ejection fraction (r = 0.50) and poorly correlated with the presence of Q waves on 12-lead electrocardiogram (r = 0.21). Direct endocardial catheter recordings performed in VT patients confirmed abnormalities of local septal activation after anterior and inferior AMI.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult

A computer model of the electrogram: what causes fractionation?

Fractionated electrograms are frequently recorded during mapping studies in patients with coronary artery disease and ventricular tachycardia. The authors developed a computer model of electrogram generation based on the biophysics of volume conductor fields. They show that fractionated electrograms can be produced as otherwise uniform wavefronts of activation encounter regions of increased cellular coupling resistance. Because of this, local activation may not correspond to the largest or most rapid deflection in a polyphasic, fractionated electrogram.

Animals

Oscillations of conduction, action potential duration, and refractoriness. A mechanism for spontaneous termination of reentrant tachycardias.

The mechanism of cycle length oscillation and its role in spontaneous termination of reentry was studied in an in vitro preparation of canine atrial tissue surrounding the tricuspid orifice. Reentry occurred around a fixed path with incomplete recovery of excitability. Among 18 experiments, there was complete concordance between the occurrence of spontaneous cycle length oscillation and spontaneous terminations; both were observed in 10 experiments and neither in the other eight (p less than 0.001). Local changes in conduction during oscillations resulted from the dependence of both conduction velocity and action potential duration on the preceding local diastolic interval. Interval-dependent changes in action potential duration contributed to the oscillation by altering the next diastolic interval. Because of changes in action potential duration, changes in cycle length were poorly correlated with changes in diastolic interval and, therefore, with local conduction velocity. Complex oscillations resulted from variations in conduction time at multiple sites in the circuit. Oscillations caused most spontaneous terminations. The critical event was an exceptionally long diastolic interval preceding the next-to-last cycle that accelerated local conduction (which tended to shorten the last cycle) and prolonged action potential duration and refractoriness at the site of block. Ninety-two of 99 recordings of spontaneous termination showed evidence of oscillation of conduction and refractoriness causing block.

Action Potentials

Clinical evaluation of a medical image management system for chest images.

The clinical efficacy and physicians' assessment of a medical image management system (MIMS) for chest images that involved the medical intensive care unit (MICU) and the radiology department were evaluated. A token-passing fiber-optic network was implemented to connect display stations in the MICU and in the chest reading area in the radiology department with a laser film digitizer and an archiving system. To study the clinical efficacy of this system, blocks of 8 weeks during which portable chest images were digitized and immediately made available in the MICU were alternated with blocks of 8 weeks during which film images only were available. Approximately 3000 portable chest examinations were tracked; patients were entered into the study at a rate of 65 per month. Data on time intervals associated with the examination process were collected from MICU physicians, radiologists, radiographers, and film librarians. The time from the completion of an examination to the time an action was taken that was based on radiographic findings showed significant reductions during the digital periods for certain actions. For example, the time to begin drug therapy decreased from a mean of 4.7 hr when films were viewed to a mean of 3.3 hr when digital images were viewed. In conclusion, if prompt action by the MICU physician improves a patient's outcome, a positive effect on patient care will result from the immediate availability of radiographic images.

Computer Systems

A model of conduction through the N region of the AV node.

A computer model of the AV node was developed in order to study mechanisms of conduction delay in the AV node. Three cells were used corresponding to the AN, N, and NH region. The basic mechanisms for delay were a high intercellular resistance and a delayed, time dependent recovery of excitability in the center cell. The action potentials for all cells were held constant. The model reproduces antegrade conduction characteristics of the AV node and the waveform of the center cell resemble the two component action potentials of N cells. The model suggests that the conduction properties of the AV node may be due to subthreshold phenomenon.

Atrioventricular Node

Results of signal-averaged electrocardiography and electrophysiologic study in patients with nonsustained ventricular tachycardia after healing of acute myocardial infarction.

Programmed stimulation and signal-averaged electrocardiography were performed in 43 consecutive patients with nonsustained ventricular tachycardia (VT) after healing of inferior (29 patients) or anterior wall (14 patients) acute myocardial infarction. Twenty-two patients had inducible sustained VT. Patients with inferior infarction and inducible sustained VT had significantly longer filtered QRS durations (125 +/- 19 vs 112 +/- 15 ms, p less than 0.01) and significantly lower voltage in the last 40 ms of the filtered QRS complex (19 +/- 5 vs 30 +/- 14 microV, p less than 0.05) than those without inducible sustained VT. In contrast, the signal-averaged electrocardiographic measurements in patients with anterior infarction and inducible sustained VT did not differ significantly from those without inducible sustained VT. The results of these studies were compared with those of 2 control groups: 45 patients without ventricular arrhythmias after myocardial infarction and 95 patients with spontaneous and inducible sustained VT after myocardial infarction. The signal-averaged electrocardiographic measurements in patients with spontaneous nonsustained VT after inferior infarction were intermediate between the control group without arrhythmias and the control group with sustained VT. The signal-averaged electrocardiograms in patients with nonsustained VT after anterior infarction were not significantly different from those in patients without ventricular arrhythmias. The study shows that the site of infarction influences the signal-averaged electrocardiogram in patients with VT after myocardial infarction. The signal-averaged electrocardiogram may be useful in identifying patients with nonsustained VT after a remote inferior myocardial infarction who have inducible sustained VT.

Cardiac Pacing, Artificial

Signal averaging.

Explore the source record for details and available documents.

Arrhythmias, Cardiac