Procedural results and late clinical outcomes following multivessel coronary stenting.

OBJECTIVES: To evaluate in-hospital and long-term clinical outcomes in a large consecutive series of patients undergoing percutaneous multivessel stent intervention. BACKGROUND: High restenosis and recurrent angina rates have limited the clinical outcomes of multivessel coronary angioplasty before stents were available to improve angioplasty results. METHODS: We evaluated in-hospital and long-term clinical outcomes (death, Q-wave myocardial infarction [MI], and repeat revascularization rates at one year) in 398 consecutive patients treated with coronary stents in two (94% of patients) or three native arteries, compared to 1,941 patients undergoing stenting procedure in a single coronary artery between January 1, 1994 and August 29, 1997. RESULTS: Overall procedural success was obtained in 96% of patients with two- or three-vessel stenting and in 970% of patients with single-vessel stent intervention (p = 0.36). Procedural complications were also similar (3.8% for multivessel versus 2.9% for single vessel, p = 0.14). During follow up, target lesion revascularization was 15% in multivessel and 16% in single-vessel interventions (p = 0.38), and repeat revascularization (calculated per treated patient) was also similar for both groups (20% vs. 21%, p = 0.73). There was no difference in death (1.4% vs. 0.7%, p = 0.26), and Q-wave MI (1.2% vs. 0%, p = 0.02) was lower following multivessel interventions. Overall cardiac event-free survival was similar for both groups (p = 0.52). CONCLUSIONS: Unlike previous conventional angioplasty experiences, multivessel stenting has (1) similar in-hospital procedural success and major complication rates and (2) similar long-term (one year) clinical outcomes compared with single-vessel stenting. Thus, stents may be a viable therapeutic strategy in carefully selected patients with multivessel coronary disease.

Angioplasty, Balloon, Coronary↗

One-year follow-up after intravascular ultrasound assessment of moderate left main coronary artery disease in patients with ambiguous angiograms.

OBJECTIVES: The purpose of this study was to correlate angiographic and intravascular ultrasound (IVUS) findings in left main coronary artery (LMCA) disease and identify the predictors of coronary events at one year in patients with LMCA stenoses. BACKGROUND: Significant (> or =50% diameter stenosis [DS]) LMCA disease has a poor long-term prognosis. METHODS: One hundred twenty-two patients who underwent angiographic and IVUS assessment of the severity of LMCA disease and who did not have subsequent catheter or surgical intervention were followed for one year. Standard clinical, angiographic and IVUS parameters were collected. RESULTS: The quantitative coronary angiography (QCA) reference diameter (3.91 +/- 0.76 mm, mean +/- 1 SD) correlated moderately with IVUS (4.25 +/- 0.78 mm, r = 0.492, p = 0.0001). The lesion site minimum lumen diameter (MLD) (2.26 +/- 0.82 mm) by QCA correlated less well with IVUS (2.8 +/- 0.82 mm, r = 0.364, p = 0.0005). The QCA DS measured 42 +/- 16%. During the follow-up period, 4 patients died, none had a myocardial infarction, 3 underwent catheter-based LMCA intervention and 11 underwent bypass surgery. Univariate predictors of events (p < 0.05) were diabetes, presence of another lesion whether treated with catheter-based intervention or untreated with DS > 50% and IVUS reference plaque burden and lesion lumen area, maximum lumen diameter, MLD, plaque area and area stenosis. Using logistic regression analysis diabetes mellitus, an untreated vessel (with a DS > 50%) and IVUS MLD were independent predictors of cardiac events. CONCLUSIONS: In selected patients assessed by IVUS, moderate LMCA disease had a one-year event rate of only 14%. Intravascular ultrasound MLD was the most important quantitative predictor of cardiac events. For any given MLD, the event rate was exaggerated in the presence of diabetes or another untreated lesion (>50% DS).

Adult↗

Acute and nine-month clinical outcomes after "suboptimal" coronary stenting: results from the STent Anti-thrombotic Regimen Study (STARS) registry.

OBJECTIVES: This registry collected the 30-day and 9-month clinical outcomes of patients whose coronary stent implantation was suboptimal, and compared them with the cohort of patients with "optimal" stenting in the randomized portion of the STent Anti-thrombotic Regimen Study (STARS) trial. BACKGROUND: Although "optimal" stenting combined with an aspirin and ticlopidine regimen carries a low (0.5%) incidence of subacute stent thrombosis, only limited data are available for patients in whom stents are deployed suboptimally. METHODS: In the STARS, 312 (15.9%) of 1,965 patients enrolled were excluded from participation in the randomized trial based on a perceived "suboptimal" result of coronary stenting. Of these, 265 patients met prespecified criteria for suboptimal stenting, and were followed in a parallel registry, which was compared with the randomized STARS optimal stenting cohort. The primary end point was a 30-day composite of death, emergent target lesion revascularization, angiographic thrombosis of the target vessel without revascularization and nonfatal myocardial infarction (MI) unrelated to direct procedural complications. RESULTS: Registry patients had a similar frequency of the primary end point compared with the overall randomized cohort (3.0% vs. 2.2%), with this end point correlating to use of multiple stents, smaller final lumen diameter and absence of ticlopidine from the poststent regimen. Overall 30-day mortality (1.1% vs. 0.06%, p = 0.009) and periprocedural non-Q wave MI (8.7% vs. 4.2%, p = 0.003) were more frequent in registry patients, and appeared to be related to acute procedural complications. Clinical restenosis was significantly higher for registry patients (26.8% vs. 16.0%, p = 0.001), relating to greater prevalence of independent predictors such as smaller final lumen diameter and multiple stent use. CONCLUSIONS: In the STARS registry, the inability to perform optimal stenting correlated with smaller final lumen diameter and longer stent length. With ticlopidine-containing regimens, the acute clinical results of "suboptimal" stent deployment are clinically acceptable, although they are not quite as good as those of optimal stenting using similar drug therapy.

Acute Disease↗

Granulomatous 'foreign body reactions' contribute to exaggerated in-stent restenosis.

BACKGROUND: Results of previous studies with stents coated with 'biocompatible' polymers showed that severe inflammatory reaction and subsequent in-stent restenosis may occur. OBJECTIVE: To evaluate the contribution of granulomatous reaction from uncoated stents to formation of in-stent neointimal hyperplasia. METHODS: Uncoated stainless-steel stents were implanted into 21 porcine coronary arteries without oversizing and harvested after 2 months (n = 6) or 6 months (n = 7). We compared the stents with granulomatous reaction with those without foreign-body reaction. RESULTS: Granulomatous reactions occurred in five 21 stents and resulted in there being significantly greater in-stent neointimal hyperplasia than there was with stents without foreign-body reaction (angiographic diameter stenosis 45 +/- 36 versus 16 +/- 16%, area of neointimal 3.30 +/- 1.4 versus 1.22 +/- 0.4 mm2, thickness of neointima 0.46 +/- 0.29 versus 0.11 +/- 0.09 mm, stenosed area 56 +/- 24 versus 20 +/- 7%, P < 0.01 for each comparison). This increase in amount of neointima was accompanied by significantly greater proliferating cell nuclear antibody staining (15 +/- 5 versus 3 +/- 2%, P < 0.05) in the presence of a granuloma near the stent struts. CONCLUSIONS: A localized granulomatous reaction is associated with a significant increase in amount of stent neointima and proliferation of cells. Thus, permanent stent implants may provoke granulomatous vascular reactions that may affect late-healing responses and clinical outcomes.

Animals↗

Electromechanical characterization of myocardial hibernation in a pig model.

BACKGROUND: This study attempted to assess in-vivo electromechanical changes following gradual coronary artery occlusion in a pig ameroid constrictor model using a novel three-dimensional left ventricular mapping system. METHODS AND RESULTS: We measured unipolar and bipolar voltage potentials and local endocardial shortening in the ischemic lateral and non-ischemic anterior zones in animals at rest (n = 9) 5 weeks after the implantation of ameroid constrictors around the left circumflex artery. Echocardiography was used to assess regional contractility (percentage myocardial thickening), and an echo-contrast perfusion study was performed using acoustic densitometry methods. The ischemic lateral zone showed reduced myocardial perfusion at rest (peak intensity; 3.4 +/- 1.7 versus 20.7 +/- 14.8, P = 0.005), impaired mechanical function (percentage wall thickening 22 +/- 19% versus 40 +/- 11%, P = 0.03; local endocardial shortening 2.9 +/- 5.5% versus 11.7 +/- 2.1%, P = 0.002), and preserved electrical activity (unipolar voltage 12.4 +/- 4.7 versus 14.4 +/- 1.9 mV, P = 0.25; bipolar voltage 4.1 +/- 1.1 versus 3.8 +/- 1.5 mV, P = 0.62), compared with the anterior region. CONCLUSIONS: Gradual coronary artery occlusion resulting in regional reduced perfusion and function at rest (i.e. hibernating myocardium) is characterized by preserved electrical activity. An electromechanical left ventricular mapping procedure such as the one described here may be of diagnostic value for identifying the hibernating myocardium.

Animals↗

Saline infusion via local drug delivery catheters is associated with increased neointimal hyperplasia in a porcine coronary in-stent restenosis model.

BACKGROUND: Catheter-based local drug delivery at the site of stent implantation has been proposed to reduce in-stent restenosis. We examined whether local delivery itself may cause additional vessel wall injury and negate the potential benefit of local drug delivery in a porcine coronary in-stent restenosis model. METHODS: Pigs were randomly assigned to no local delivery (controls, n = 10) or local saline infusion (5 ml) using commercially available catheters (n = 39; Dispatch catheter, Microporous Infusion catheter, and InfusaSleeve) prior to oversized (stent:artery ratio 1.2) coronary stent implantation. The amount of in-stent neointima was evaluated 4 weeks later with angiography and histology. RESULTS: There was no difference in vessel size or stent: artery ratio. However, at follow-up the local saline delivery group had significantly greater diameter stenosis (50 +/- 19% versus 25 +/- 17% in the controls, P < 0.01). Histology revealed similar injury scores but significantly greater neointimal area in the local saline group (3.61 +/- 1.11 mm2 versus 1.96 +/- 0.82 mm2 in the controls, P < 0.01). In a multivariate linear regression analysis, the use of the local delivery catheter was the only independent variable which was positively correlated with the amount of neointima (P = 0.0001). CONCLUSIONS: In this in-stent restenosis model, catheter-based local saline delivery was associated with significantly increased neointimal hyperplasia. Thus, for local drug delivery to reduce in-stent restenosis, the antiproliferative agent should be potent enough to compensate for the additional neointimal hyperplasia from the infusion itself.

Animals↗

Studies on the histogenesis of myxomatous tissue of human coronary lesions.

Myxomatous tissue is a characteristic component of human coronary artery lesions, found more often in restenotic lesions. It represents a bulky accumulation of stellate-shaped cells of unknown histogenesis that are embedded in a loose stroma. We analyzed 64 atherectomy specimens containing substantial amounts of myxomatous tissue by using immunohistochemistry, in situ hybridization, and electron microscopy techniques. Stellate cells represented a heterogeneous population, sharing features of smooth muscle cells (SMCs), macrophages, as well as antigen-presenting dendritic cells. Like quiescent medial SMCs, the stellate cells in all specimens expressed high levels of SM alpha-actin message and protein and showed heterogeneity with respect to heavy-chain myosin, SM22, desmin, and vimentin. Ultrastructurally, stellate cells resembled SMCs, with some peculiarities that distinguish them from both differentiated and dedifferentiated SMCs. In contrast to quiescent SMCs, the stellate cells expressed high levels of acidic fibroblast growth factor mRNA and protein similar to cells of monocyte/macrophage lineage. However, stellate cells did not express the marker of mature macrophages, HAM56, and were heterogeneous with respect to CD68. Moreover, unlike SMCs, the stellate cells bore some of the major phenotypic markers of dendritic cells: they were S100-positive and showed various reactivity with respect to CD1a and human leukocyte antigen (HLA)-DR. Invasion of myxomatous tissue with CD45RO-positive T lymphocytes was correlated with strong expression of CD1a in these specimens. Stellate cells also expressed a pericyte marker, high-molecular-weight melanoma-associated antigen. We conclude that stellate cells of myxomatous tissue represent a specific phenotype of mesenchymal cells (possibly pericytes), which is activated to express some markers of antigen-presenting cells. These findings suggest involvement of the stellate cells in a local immune response.

Actins↗

Coronary artery stents: appropriate use of adjunctive pharmacotherapy to prevent stent thrombosis.

In 1986, the first metallic stent was implanted inside a human coronary artery in order to reduce the incidence of abrupt vessel occlusion and restenosis after percutaneous coronary balloon angioplasty. Little was known at that time regarding the adequate anticoagulation regimen needed and the initial enthusiasm was soon marred by a high rate of thrombotic stent closure that usually occurred 2 days to 4 weeks after stent implantation. Antithrombotic drugs such as heparin, aspirin (acetylsalicylic acid), low molecular weight heparins, dextran, dipyridamole and warfarin (coumadin) were incorporated in a series of trials which reduced the risk of stent thrombosis, but increased substantially the rate of bleeding complications and the length of hospitalisation. The greatest breakthrough came with the improvement in stent deployment techniques using intravascular ultrasound-guided, high-pressure balloon inflation inside the stent, and the understanding of the central role of platelet activation in stent thrombosis. These 2 factors have led to 'optimal stent deployment' with high-pressure ballooning after stent deployment and the simultaneous use of more potent antiplatelet agents in conjunction with aspirin. Newly developed selective inhibitors of the platelet glycoprotein IIb/IIIa receptor and new stent designs have also recently been integrated into clinical practice and are currently being evaluated in clinical trials.

Adjuvants, Pharmaceutic↗

Severe spasm of the free radial artery graft in a patient undergoing high-risk angioplasty under percutaneous cardiopulmonary support.

This report illustrates a case of percutaneous intervention in a very high-risk patient who already had three previous bypass operations and was not a suitable candidate for further surgical revascularization. Since intra-aortic balloon pump insertion was contraindicated due to the origin of a radial graft from the descending aorta, percutaneous cardiopulmonary support (CPS) was used to perform the procedure. Thus, CPS proved useful in providing adequate hemodynamic support and allowed us to use adequate amount of antispastic drugs to relieve any spasm during the procedure. This case also highlights the need to use antispastic drugs before performing percutaneous interventions on arterial conduits, particularly radial artery grafts which are prone to vasospasm. Since the use of the radial artery for bypass surgery has recently been revived with considerable interest, perhaps more percutaneous interventional procedures may be performed in the future on arterial graft stenosis. We therefore recommend the routine use of vasorelaxant drugs in percutaneous interventions involving arterial grafts.

Aged↗

Intra-arterial reteplase for the treatment of acute limb ischemia.

The removal of urokinase from the market has created a dilemma for interventionists and vascular surgeons treating patients with acute limb threatening ischemia due to arterial thrombosis or embolization. Reteplase is a newer, fibrin-specific thrombolytic agent with properties that make it an attractive alternative to urokinase. We report two cases of successful treatment of acute, limb threatening ischemia with intra-arterial Reteplase therapy.

Acute Disease↗

Electromechanical characterization of acute experimental myocardial infarction.

OBJECTIVE: A new cardiac mapping system combines harmless magnetic field energy and tip-deflecting catheters (equipped with location sensors) to obtain real-time 3-dimensional electromechanical maps of the left ventricle endocardial surface without using x-ray fluoroscopy. This experimental study assessed electromechanical changes during acute coronary occlusion and reperfusion in a canine model. METHODS: Group 1 (n = 10) underwent coronary occlusion for 45 minutes followed by reperfusion (n = 6) and group 2 (n = 11) underwent coronary occlusion for 90 minutes. Endocardial peak-to-peak voltage amplitudes and local endocardial shortening values were measured in ischemic and non-ischemic zones at baseline, following coronary occlusion and reperfusion. RESULTS: In ischemic zones, local shortening was significantly reduced during coronary occlusion compared to baseline (Group 1: 4.7 +/- 2.0% at 45 minutes vs. 15.5 +/- 3.4%, p < 0.001, 6.2 +/- 2.1% at 90 minutes vs. 15.5 +/- 3.4%, p < 0.001; Group 2: 5.0 +/- 2.9% at 90 minutes vs. 13.9 +/- 3.3%, p = 0.007). Coronary occlusion caused a significant reduction in voltage potentials in the ischemic area (unipolar voltage at 45 minutes: 32.2 +/- 7.3 mV vs. 36.2 +/- 8.5 mV at baseline, p = 0.03; unipolar voltage at 90 minutes: 30.5 +/- 11.3 mV vs. 38.3 +/- 14.2 mV, p = 0.003; bipolar voltage at 45 minutes: 7.6 +/- 5.5 mV vs. 10.1 +/- 6.0 mV, p < 0.04; bipolar voltage at 90 minutes: 7.6 +/- 4.4 mV vs. 9.8 +/- 6.2 mV, p < 0.02). Voltage amplitudes were no longer reduced during reperfusion (unipolar voltage: 34.3 +/- 10.5 mV vs. 36.2 +/- 8.5 mV, p = 0.26; bipolar voltage: 9.1 +/- 4.5 mV vs. 10.1 +/- 6.0 mV at baseline, p = 0.37), or in non-ischemic regions during either coronary occlusion or reperfusion. CONCLUSIONS: Electromechanical mapping study provides unique insights into acute myocardial infarction and stunning by detection and localization of early electromechanical changes during coronary occlusion and/or reperfusion.

Animals↗

A clinical trial comparing three antithrombotic-drug regimens after coronary-artery stenting. Stent Anticoagulation Restenosis Study Investigators.

BACKGROUND: Antithrombotic drugs are used after coronary-artery stenting to prevent stent thrombosis. We compared the efficacy and safety of three antithrombotic-drug regimens - aspirin alone, aspirin and warfarin, and aspirin and ticlopidine - after coronary stenting. METHODS: Of 1965 patients who underwent coronary stenting at 50 centers, 1653 (84.1 percent) met angiographic criteria for successful placement of the stent and were randomly assigned to one of three regimens: aspirin alone (557 patients), aspirin and warfarin (550 patients), or aspirin and ticlopidine (546 patients). All clinical events reflecting stent thrombosis were included in the prespecified primary end point: death, revascularization of the target lesion, angiographically evident thrombosis, or myocardial infarction within 30 days. RESULTS: The primary end point was observed in 38 patients: 20 (3.6 percent) assigned to receive aspirin alone, 15 (2.7 percent) assigned to receive aspirin and warfarin, and 3 (0.5 percent) assigned to receive aspirin and ticlopidine (P=0.001 for the comparison of all three groups). Hemorrhagic complications occurred in 10 patients (1.8 percent) who received aspirin alone, 34 (6.2 percent) who received aspirin and warfarin, and 30 (5.5 percent) who received aspirin and ticlopidine (P<0.001 for the comparison of all three groups); the incidence of vascular surgical complications was 0.4 percent (2 patients), 2.0 percent (11 patients), and 2.0 percent (11 patients), respectively (P=0.01). There were no significant differences in the incidence of neutropenia or thrombocytopenia (overall incidence, 0.3 percent) among the three treatment groups. CONCLUSIONS: As compared with aspirin alone and a combination of aspirin and warfarin, treatment with aspirin and ticlopidine resulted in a lower rate of stent thrombosis, although there were more hemorrhagic complications than with aspirin alone. After coronary stenting, aspirin and ticlopidine should be considered for the prevention of the serious complication of stent thrombosis.

Aged↗

A subgroup analysis of the Scripps Coronary Radiation to Inhibit Proliferation Poststenting Trial.

INTRODUCTION: In the Scripps Coronary Radiation to Inhibit Proliferation Poststenting (SCRIPPS) Trial, 192Ir significantly reduced angiographic, ultrasonographic, and clinical endpoints of restenosis. The objective of this analysis was to quantitate the impact of patient, lesion and technical characteristics on late angiographic outcome. METHODS: Patients with restenotic, stented coronary lesions were randomized to receive either 192Ir or placebo sources. Late luminal loss and loss index were calculated for several patient subgroups, including patients with diabetes, in-stent restenosis, multiple previous percutaneous transluminal coronary angioplasty (PTCA) procedures, longer lesion lengths, saphenous vein grafts, small vessel diameters, and minimum dose exposures < 8.00 Gy. Two-factor analysis of variance was used to test for an interaction between patient characteristics and treatment effect. RESULTS: In the treated group, late loss was particularly low in patients with diabetes (0.19 mm), in-stent restenosis (0.17 mm), reference vessel diameters < 3.0 mm (0.07 mm), and patients who received a minimum radiation dose to the entire adventitial border of at least 8.00 Gy. The loss index in each of these subgroups was similarly low at -0.02, 0.03, -0.02, and 0.03, respectively. By 2-factor analysis of variance, a significant interaction between subgroup characteristic and treatment effect (late loss) was found in patients with in-stent restenosis (p = 0.035), and patients receiving a minimum dose of 8.00 Gy to the adventitial border (p = 0.009). CONCLUSION: In this pilot study, patient characteristics associated with a more aggressive proliferative response to injury appeared to confer an enhanced response to radiotherapy. Furthermore, a dose threshold response to 192Ir was found with an enhanced response occurring when the entire circumference of the adventitial border was exposed to at least 8.00 Gy.

Analysis of Variance↗

Procedural results and long-term clinical outcomes following coronary stenting in perimyocardial infarction syndromes.

Initial experiences with coronary stents in acute coronary syndromes have suggested higher risk of ischemic complications and stent thrombosis. We evaluated in-hospital and 1-year clinical outcomes of coronary stent implantation in perimyocardial infarction (MI) syndromes. We studied 334 consecutive patients undergoing stent interventions in the first week after acute MI. Stenting was performed within 24 hours (n = 31), within 1 to 3 days (n = 95), and within 4 to 7 days (n = 208). Stents were used to improve angioplasty results and to treat dissections and abrupt/threatened closure. Postprocedure anticoagulation regimens were aspirin, ticlopidine, and low molecular weight heparin. Overall procedural success was achieved in 93% of patients. Major in-hospital complications included death (1.0%), recurrent Q-wave MI (0.6%), and emergent bypass surgery (3.0%). Stent thrombosis occurred in 0.6% of patients. At follow-up, cardiac event-free survival was 80%, mortality 2.2%, recurrent MI 3.5%, and target lesion revascularization 11%. We conclude that coronary stenting in periinfarction syndromes was effective in achieving sustained clinical benefit up to 1 year with low morbidity and mortality. Thus, stents seem to be a viable therapeutic strategy in patients sustaining perimyocardial infarction syndromes.

Aged↗

Intimal hyperplasia thickness at follow-up is independent of stent size: a serial intravascular ultrasound study.

The purpose of this study was to determine whether the thickness of the intimal hyperplasia (IH) layer that accumulates within Palmaz-Schatz stents is dependent on stent size. Intravascular ultrasound (IVUS) and quantitative angiographic (QCA) studies were performed after stent implantation and at follow-up (5.4 +/- 3.8 months) in 161 patients with 177 lesions treated with 221 Palmaz-Schatz stents. Stent and lumen cross-sectional area (CSA) were measured. IH CSA and thickness at follow-up were calculated and compared with stent CSA and circumference. Maximum IH CSA and thickness were measured at the smallest follow-up lumen CSA; mean IH CSA and thickness was averaged over the length of the stent. Maximum IH CSA measured 4.8 +/- 2.4 mm2, and mean IH CSA measured 2.8 +/- 2.2 mm2. Maximum IH thickness (at the smallest follow-up lumen CSA) measured 0.60 +/- 0.36 mm, and mean IH thickness (over the length of the stent) measured 0.30 +/- 0.19 mm. There was a weak, but significant correlation between mean and maximum IH CSA versus stent CSA (r = 0.215, p <0.0001 and r = 0.355, p <0.0001, respectively). However, there was no correlation between mean or maximum IH thickness versus stent CSA (r = 0.018, p = 0.643 and r = 0.056, p = 0.463, respectively) or stent circumference (r = 0.002, p = 0.956 and r = 0.069, p = 0.361, respectively). IH thickness was found to be independent of the stent size. This explains the known higher frequency of restenosis in smaller stents compared with larger stents.

Adult↗

Comparison between left ventricular electromechanical mapping and radionuclide perfusion imaging for detection of myocardial viability.

BACKGROUND: A novel 3-dimensional left ventricular (LV) mapping system uses low-intensity magnetic field energy to determine the location of sensor-tipped electrode catheters within the LV. Using this system, we sought to distinguish between infarcted, ischemic, and normal myocardium by comparing LV electromechanical mapping data with myocardial perfusion imaging studies. METHODS AND RESULTS: Unipolar voltage potentials and local endocardial shortening (LS) were measured in 18 patients (mean age, 58+/-12 years) with symptomatic chronic angina having reversible and/or fixed myocardial perfusion defects on single photon emission computed tomography imaging studies using 201Tl at rest and 99mTc-sestamibi after adenosine stress. Overall, a significant difference in voltage potentials and LS values was found between groups (P<0.001 for each comparison by ANOVA). The average voltage potentials (14.0+/-2.0 mV) and LS values (12.5+/-2.8%) were highest when measured in myocardial segments (n=56) with normal perfusion and lowest (7.5+/-3.4 mV and 3.4+/-3.4%) when measured in myocardial segments with fixed perfusion defects (n=20) (P<0.0001). Myocardial segments with reversible perfusion defects (n=66) had intermediate voltage amplitudes (12.0+/-2.8 mV, P=0.048 versus normal and P=0.005 versus fixed segments) and LS values (10.3+/-3.7%, P=0.067 versus normal and P=0.001 versus fixed segments). CONCLUSIONS: In patients with myocardial ischemia, LV mapping, compared with myocardial perfusion imaging, shows (1) mild reduction of endocardial voltage potentials and LS in segments with reversible perfusion defects and (2) profound electromechanical impairment in segments with fixed perfusion defects. Thus, such an LV mapping procedure may allow the detection on-line of myocardial viability in the catheterization laboratory.

Aged↗

Preliminary animal and clinical experiences using an electromechanical endocardial mapping procedure to distinguish infarcted from healthy myocardium.

BACKGROUND: A catheter-based left ventricular (LV) endocardial mapping procedure using electromagnetic field energy for positioning of the catheter tip was designed to acquire simultaneous measurements of endocardial voltage potentials and myocardial contractility. We investigated such a mapping system to distinguish between infarcted and normal myocardium in an animal infarction model and in patients with coronary artery disease. METHODS AND RESULTS: Measurements of LV endocardial unipolar (UP) and bipolar (BP) voltages and local endocardial shortening were derived from dogs at baseline (n=12), at 24 hours (n=6), and at 3 weeks (n=6) after occlusion of the left anterior descending coronary artery. Also, 12 patients with prior myocardial infarction (MI) and 12 control patients underwent the LV endocardial mapping study for assessment of electromechanical function in infarcted versus healthy myocardial regions. In the canine model, a significant decrease in voltage potentials was noted in the MI zone at 24 hours (UP, 42. 8+/-9.6 to 29.1+/-12.2 mV, P=0.007; BP, 11.6+/-2.3 to 4.9+/-1.2 mV, P<0.0001) and at 3 weeks (UP, 41.0+/-8.9 to 13.9+/-3.9 mV, P<0.0001; BP, 11.2+/-2.8 to 2.4+/-0.4 mV, P<0.0001). No change in voltage was noted in zones remote from MI. In patients with prior MI, the average voltage was 7.2+/-2.7 mV (UP)/1.4+/-0.7 mV (BP) in MI regions, 17.8+/-4.6 mV (UP)/4.5+/-1.1 mV (BP) in healthy zones remote from MI, and 19.7+/-4.4 mV (UP)/5.8+/-1.0 mV (BP) in control patients without prior MI (P<0.001 for MI values versus remote zones or control patients). In the canine model and patients, local endocardial shortening was significantly impaired in MI zones compared with controls. CONCLUSIONS: These preliminary data suggest that infarcted myocardium could be accurately diagnosed and distinguished from healthy myocardium by a reduction in both electrical voltage and mechanical activity. Such a diagnostic electromechanical mapping study might be clinically useful for accurate assessment of myocardial function and viability.

Animals↗

Intravascular ultrasound findings in stenting of unprotected left main coronary artery stenosis.

We evaluated the role of intravascular ultrasound (IVUS) in 16 patients with unprotected left main coronary artery (LMCA) stenting compared with 80 patients with other (non-LMCA) native coronary artery stenting and found that (1) additional high-pressure or larger size balloon dilations were more frequently performed in LMCA stenting than in non-LMCA stenting (p <0.05) and (2) after IVUS-guided stent implantation, minimum lumen area was > or = 9 mm2 in 88% of patients who underwent LMCA stenting and in 19% of those who underwent non-LMCA stenting (p <0.001). IVUS guidance may be a more important adjunctive imaging modality in the stenting of unprotected LMCA stenoses than in stenting of non-LMCA stenoses.

Aged↗