Search PubMed⌕ Search

Biomedical subjects

M B Leon

Publications and source records attributed to M B Leon.

At least 55 records · Page 3Linked to original sources

Embolization via collateral circulation during carotid stenting with the distal balloon protection system.

PURPOSE: To describe a potential route for embolization to the middle cerebral artery (MCA) during carotid stenting with the distal balloon protection system. CASE REPORT: An 82-year-old man with symptomatic severe carotid artery stenosis underwent elective carotid stenting with distal-balloon protection. Despite complete occlusion of the distal internal carotid artery, frequent emboli were detected in the ipsilateral MCA by transcranial Doppler (TCD) during the procedure. Intracranial angiography, performed during the distal-balloon protection, revealed filling of the MCA through collaterals from the ipsilateral external carotid artery. The procedure was successfully completed without complications. The patient remains asymptomatic at 6 months. CONCLUSIONS: During carotid stenting with distal-balloon protection, asymptomatic embolization into the ipsilateral MCA may occur through collateral circulation. The clinical significance of these emboli is uncertain.

Aged↗

Effect of preintervention plaque burden on subsequent intimal hyperplasia in stented coronary artery lesions.

We sought to determine if axial and circumferential distribution of plaque before stenting determines the axial and circumferential distribution of subsequent intimal hyperplasia (IH). We studied 22 patients with a single Palmaz-Schatz stent implanted in a native coronary artery, who underwent intravascular ultrasound (IVUS) imaging before intervention, after stenting, and at 6-month follow-up. For each lesion, 7 locations were analyzed: proximal and distal reference, proximal and distal edge of the stent, proximal and distal location within the body of the stent, and the articulation. Pre- and postintervention and follow-up image slices were precisely aligned and analyzed for pre- and postintervention plaque area and follow-up IH area and thickness. The location of maximal IH area was at or adjacent to the location of maximal preintervention plaque in 17 of 22 of the patients (77%). Similiarly, the circumferential distribution of IH at follow-up paralleled the eccentricity pattern of the native plaque burden in 69% (24 of 35 slices). Using multivariant analysis, the strongest predictor of IH was preintervention plaque area (p = 0.001). IH accumulates axially and circumferentially preferentially at the site of maximal preintervention plaque.

Angioplasty, Balloon, Coronary↗

Effect of intracoronary gamma-radiation therapy on in-stent restenosis: An intravascular ultrasound analysis from the gamma-1 study.

BACKGROUND: The aim of this study was to use serial volumetric intravascular ultrasound to evaluate the effect of gamma-radiation on recurrent in-stent restenosis. METHODS AND RESULTS: After successful reintervention, patients were randomized to receive either (192)Ir or placebo. Intravascular ultrasound studies with motorized pullback (0.5 mm/s) were performed immediately after irradiation and at 8-month follow-up in 70 patients. Paired volumetric analysis of the stented segment and of 5-mm proximal and distal reference segments was performed; this included measurements of the external elastic membrane, lumen, plaque and media (external elastic membrane minus lumen), stent, and intimal hyperplasia (stent minus lumen). Baseline proximal reference, stent, and distal reference measurements were similar in both groups. The changes in proximal and distal reference measurements of the external elastic membrane, plaque and media, and lumen areas were similar in both groups. However, the decrease in stented segment lumen volume was less in the (192)Ir patients than the placebo patients (-25+/-34 mm(3) versus -48+/-42 mm(3); P:=0.0225), and the increase in the volume of intimal hyperplasia in the stented segment was less in the (192)Ir patients than in the placebo patients (28+/-37 mm(3) versus 50+/-40 mm(3); P:=0.0352). When averaged over the length of the stented segment (32+/-13 mm versus 33+/-14 mm; P:=0.9), the increase in mean area of intimal hyperplasia was 0.8+/-1.0 mm(2) in the (192)Ir group and 1.6+/-1.2 mm(2) in the control group (P:=0.0065). Late stent-vessel wall malapposition was noted in one placebo patient and no (192)Ir patients. CONCLUSIONS: gamma-Radiation therapy can effectively prevent recurrent in-stent restenosis by inhibiting neointimal formation within the stent. At the stent edge, there were no significant differences between (192)Ir and placebo patients.

Analysis of Variance↗

One-year clinical outcome after minimally invasive direct coronary artery bypass.

BACKGROUND: Minimally invasive coronary artery bypass (MIDCAB) is a new surgical technique by which the left internal mammary artery is anastomosed under direct visualization to the left anterior descending artery without cardiopulmonary bypass. METHODS AND RESULTS: We followed all 274 patients who underwent MIDCAB from the time it was introduced at a single center. In-hospital and 1-year clinical events were source-documented and adjudicated. The in-hospital major acute cardiac event rate was 2.2%; this included a 1.1% mortality rate. At 1 year, the respective rates were 7.8% and 2. 5%. When compared with the initial 100 procedures, the subsequent 174 procedures had shorter vessel occlusion times (10+/-5 versus 14+/-6 minutes; P:=0.009), times to extubation (6+/-3 versus 14+/-10 hours; P:<0.001), and lengths of hospital stay (2.1+/-1.9 versus 3. 2+/-3.1 days; P:=0.04). Cumulative 1-year adverse cardiac events were 11% in the initial 100 cases and 6% in the subsequent 174 cases (P:=0.17). CONCLUSIONS: Excellent clinical results can be achieved with the MIDCAB technique. The clinical adverse event rate may decrease with accumulated experience.

Cardiopulmonary Bypass↗

Assessing a strategy of initial stand-alone extractional atherectomy followed by staged stent placement in degenerated saphenous vein graft lesions.

To assess whether a staged strategy (initial stand alone transluminal extraction atherectomy and coumadin therapy followed by stenting six weeks later) could reduce ischemic complications in degenerated saphenous vein graft (SVG) interventions, we studied 72 patients undergoing percutaneous interventions of degenerated SVG. Patients were divided into two groups; 28 were treated with a staged strategy (group I) and 44 with similar lesion characteristics were treated with a definitive initial procedure with transluminal extraction atherectomy +/- adjunctive balloon angioplasty and stenting (group II). Procedural success, major in-hospital complications (death, Q-wave myocardial infarction, and emergent coronary bypass surgery), and incidence of distal embolization were compared between the 2 groups. Procedural success was lower (92% vs 100%, p = 0.14) and major in-hospital complications were higher (0% vs 11%, p = 0.14) in group II. Distal embolization occurred in 11% of the patients in group I compared with 23% of the patients in group II (p = 0.19). At 6 week follow-up (group I), 9 patients (33%) had negative symptoms, 11 (41%) underwent stent implantation, 3 (11%) did not require any further therapy (without significant stenosis), and 4 (14%) had total occlusions. We therefore conclude that this staged strategy in degenerated SVG appears to reduce distal embolization but most importantly avoids major in-hospital complications, including any deaths either at the time of initial procedure or during the 6-week follow-up period.

Aged↗

S-nitrosoglutathione reduces nonocclusive thrombosis rate following balloon overstretch injury and intracoronary irradiation of porcine coronary arteries.

PURPOSE: Intracoronary radiation (IR) suppresses neointima formation following balloon injury in animal models. High doses of radiation exacerbate thrombosis and delay re-endothelialization. The free radical nitric oxide (NO) has been reported to inhibit platelet aggregation, reduce neointimal hyperplasia, and stimulate re-endothelialization. This study examined the effects of a chemical NO donor on neointima formation, thrombosis, and healing of irradiated porcine coronary arteries. METHODS AND MATERIALS: Vascular lesions were created in the coronary arteries of 59 domestic swine by overstretch balloon injury. Arteries were then left untreated or were treated with intracoronary gamma-radiation using Iridium-192 in each artery to deliver 5 or 15 Gy at 2 mm from the center of the source. The chemical NO donor S-nitrosoglutathione (GSNO) was infused i.v. at a rate of 250 microg/min for 10 min before injury, followed by a continuous infusion for 60 min. Animals were euthanized at 14 days and their arteries were analyzed for histomorphometric indices of proliferation and thrombosis. RESULTS: A dose of 15 Gy reduced the ratio of intimal area to medial fracture length (IA/FL) versus control (0.06 +/- 0.05 0.54 +/- 0.10 [p < 0. 001]) but increased the nonocclusive thrombosis rate compared to controls (85% vs. 30%; p < 0.05). A low dose of 5 Gy did not affect neointima formation. Treatment with GSNO reduced thrombosis in all treated groups: control, 15%; 5 Gy, 18%; and 15 Gy, 35% (p < 0.05) without affecting neointima formation. CONCLUSION: Systemic administration of GSNO during balloon injury and IR was tolerated well by the swine and resulted in reduction of the thrombosis rate, especially at high doses, without apparent effect on neointima formation.

Animals↗

The prognostic implications of further renal function deterioration within 48 h of interventional coronary procedures in patients with pre-existent chronic renal insufficiency.

BACKGROUND: Acute deterioration in renal function is a recognized complication after coronary angiography and intervention. OBJECTIVES: The goal of this study was to determine the impact on acute and long-term mortality and morbidity of contrast-induced deterioration in renal function after coronary intervention. METHODS: We studied 439 consecutive patients who had a baseline serum creatinine > or = 1.8 mg/dL (159.1 /micromol/L) who were not on dialysis who underwent percutaneous coronary intervention in a tertiary referral center. All patients were hydrated before the procedure, and almost all received ioxaglate meglumine; 161 (37%) patients had an increase in serum creatinine > or = 25% within 48 h or required dialysis and 278 (63%) did not. In-hospital and out-of-hospital clinical events (death, myocardial infarction, repeat revascularization) were assessed by source documentation. RESULTS: Independent predictors of renal function deterioration were left ventricular ejection fraction (p = 0.02) and contrast volume (p = 0.01). In-hospital mortality was 14.9% for patients with further renal function deterioration versus 4.9% for patients with no creatinine increase (p = 0.001); other complications were also more frequent. Thirty-one patients required hemodialysis; their in-hospital mortality was 22.6%. Four patients were discharged on chronic dialysis. The cumulative one-year mortality was 45.2% for those who required dialysis, 35.4% for those who did not require dialysis and 19.4% for patients with no creatinine increase (p = 0.001). Independent predictors of one-year mortality were creatinine elevation (p = 0.0001), age (p = 0.03) and vein graft lesion location (p = 0.08). CONCLUSIONS: For patients with pre-existing renal insufficiency, renal function deterioration after coronary intervention is a marker for poor outcomes. This is especially true for patients who require dialysis.

Aged↗

Randomized comparison of GR-II stent and Palmaz-Schatz stent for elective treatment of coronary stenoses.

BACKGROUND: This prospective multicenter randomized clinical trial was designed to evaluate the long-term angiographic and clinical outcomes of elective treatment with the GR-II stent compared with the Palmaz-Schatz (PS) stent in patients with coronary stenoses. METHODS AND RESULTS: Seven hundred fifty-five patients with myocardial ischemia and de novo native coronary stenoses in 3- to 4-mm vessels were randomly assigned to the PS (375 patients) or the GR-II stent (380 patients). The primary end point was 12-month target lesion revascularization (TLR)-free survival. Angiography was performed at baseline and at follow-up in the first 300 consecutive patients to assess the frequency of angiographic restenosis. Procedure success was 98.5% for the GR-II stent and 99.4% for the PS stent (P:=0.19). At 30 days, patients assigned to the GR-II stent had a higher stent thrombosis rate (3.9% versus 0.3% for PS stent, P:<0.001) and TLR rate (3.9% versus 0.5% for PS stent, P:<0.001). The GR-II group had a higher follow-up restenosis frequency (47.3% versus 20.6% for the PS group, P:<0.001) and a lower 12-month TLR-free survival rate (71.7% versus 83.9% for the PS group, P:<0. 001). Multivariate logistic regression analysis identified a smaller final stent minimal lumen diameter (odds ratio [OR] 2.49, 95% CI 1. 56 to 3.98; P:<0.001), diabetes mellitus (OR 2.14, 95% CI 1.42 to 3. 22; P:<0.001), and use of the GR-II stent (OR 1.78, 95% CI 1.20 to 2. 64; P:<0.01) as independent determinants of 12-month TLR. CONCLUSIONS: On the basis of these long-term follow-up data, we conclude that use of the GR-II stent should be limited to the acute treatment of abrupt or threatened closure after failed conventional balloon angioplasty procedures.

Analysis of Variance↗

Incidence, management, and outcome of coronary artery perforation during percutaneous coronary intervention.

We have analyzed the incidence, management, and outcome of 84 cases of coronary artery perforation in patients who underwent percutaneous coronary intervention at our institution. This complication was more frequent in female patients and in patients who underwent lesion modification with atheroablative devices. A total of 8 patients (9.5%) died after the procedure. They were usually older and had a higher incidence of cardiac tamponade; a larger percentage of these patients underwent emergency surgery than those who survived.

Adult↗

Short- and intermediate-term clinical outcomes from direct myocardial laser revascularization guided by biosense left ventricular electromechanical mapping.

BACKGROUND: Direct myocardial revascularization (DMR) has been examined as an alternative treatment for patients with chronic refractory myocardial ischemic syndromes who are not candidates for conventional coronary revascularization. Methods and Results-We used left ventricular electromagnetic guidance in 77 patients with chronic refractory angina (56 men, mean age 61+/-11 years, ejection fraction 0.48+/-0.11) to perform percutaneous DMR with an Ho:YAG laser at 2 J/pulse. Procedural success (laser channels placed in prespecified target zones) was achieved in 76 of 77 patients with an average of 26+/-10 channels (range 11 to 50 channels). The rate of major in-hospital cardiac adverse events was 2.6%, with no deaths or emergency operations, 1 patient with postprocedural pericardiocentesis, and 1 patient with minor embolic stroke. The rate of out-of-hospital adverse cardiac events (up to 6 months) was 2.6%, with 1 patient with myocardial infarction and 1 patient with stroke. Exercise duration after DMR increased from 387+/-179 to 454+/-166 seconds at 1 month and to 479+/-161 seconds at 6 months (P=0.0001). The time to onset of angina increased from 293+/-167 to 377+/-176 seconds at 1 month and to 414+/-169 seconds at 6 months (P=0.0001). Importantly, the time to ST-segment depression (>/=1 mm) also increased from 327+/-178 to 400+/-172 seconds at 1 month and to 436+/-175 seconds at 6 months (P=0.001). Angina (Canadian Cardiovascular Society classification) improved from 3.3+/-0.5 to 2.0+/-1.2 at 6 months (P<0.001). Nuclear perfusion imaging studies with a dual-isotope technique, however, showed no significant improvements at 1 or 6 months. CONCLUSIONS: Percutaneous DMR guided by left ventricular mapping is feasible and safe and reveals improved angina and prolonged exercise duration for up to a 6-month follow-up.

Adult↗

Final results of the Can Routine Ultrasound Influence Stent Expansion (CRUISE) study.

BACKGROUND: Intravascular ultrasound (IVUS) can assess stent geometry more accurately than angiography. Several studies have demonstrated that the degree of stent expansion as measured by IVUS directly correlated to clinical outcome. However, it is unclear if routine ultrasound guidance of stent implantation improves clinical outcome as compared with angiographic guidance alone. METHODS AND RESULTS: The CRUISE (Can Routine Ultrasound Influence Stent Expansion) study, a multicenter study IVUS substudy of the Stent Anti-thrombotic Regimen Study, was designed to assess the impact of IVUS on stent deployment in the high-pressure era. Nine centers were prospectively assigned to stent deployment with the use of ultrasound guidance and 7 centers to angiographic guidance alone with documentary (blinded) IVUS at the conclusion of the procedure. A total of 525 patients were enrolled with completed quantitative coronary angiography, quantitative coronary ultrasound, and clinical events adjudicated at 9 months for 499 patients. The IVUS-guided group had a larger minimal lumen diameter (2.9+/-0.4 versus 2.7+/-0. 5 mm, P<0.001) by quantitative coronary angiography and a larger minimal stent area (7.78+/-1.72 versus 7.06+/-2.13 mm(2), P<0.001) by quantitative coronary ultrasound. Target vessel revascularization, defined as clinically driven repeat interventional or surgical therapy of the index vessel at 9 month-follow-up, occurred significantly less frequently in the IVUS-guided group (8.5% versus 15.3%, P<0.05; relative reduction of 44%). CONCLUSIONS: These data suggest that ultrasound guidance of stent implantation may result in more effective stent expansion compared with angiographic guidance alone.

Aspirin↗

Treatment of in-stent restenosis with excimer laser coronary angioplasty versus rotational atherectomy: comparative mechanisms and results.

BACKGROUND: Atheroablation yields improved clinical results for balloon angioplasty (percutaneous transluminal coronary angioplasty, PTCA) in the treatment of diffuse in-stent restenosis (ISR). METHODS AND RESULTS: We compared the mechanisms and clinical results of excimer laser coronary angioplasty (ELCA) versus rotational atherectomy (RA), both followed by adjunct PTCA; 119 patients (158 ISR lesions) were treated with ELCA+PTCA and 130 patients (161 ISR lesions) were treated with RA+PTCA. Quantitative coronary angiographic and planar intravascular ultrasound (IVUS) measurements were performed routinely. In addition, volumetric IVUS analysis to compare the mechanisms of lumen enlargement was performed in 28 patients with 30 lesions (16 ELCA+PTCA, 14 RA+PTCA). There were no significant between-group differences in preintervention or final postintervention quantitative coronary angiographic or planar IVUS measurements of luminal dimensions. Angiographic success and major in-hospital complications with the 2 techniques were also similar. Volumetric IVUS analysis showed significantly greater reduction in intimal hyperplasia volume after RA than after ELCA (43+/-14 versus 19+/-10 mm(3), P<0.001) because of a significantly higher ablation efficiency (90+/-10% versus 76+/-12%, P = 0.004). However, both interventional strategies had similar long-term clinical outcome; 1-year target lesion revascularization rate was 26% with ELCA+PTCA versus 28% with RA+PTCA (P = NS). CONCLUSIONS: Despite certain differences in the mechanisms of lumen enlargement, both ELCA+PTCA and RA+PTCA can be used to treat diffuse ISR with similar clinical results.

Angioplasty, Balloon, Coronary↗

Safety of intracoronary gamma-radiation on uninjured reference segments during the first 6 months after treatment of in-stent restenosis: a serial intravascular ultrasound study.

BACKGROUND: The effects of endovascular irradiation on uninjured reference segments during the treatment of in-stent restenosis are unknown. METHODS AND RESULTS: In the Washington Radiation for In-Stent restenosis Trial (WRIST), patients with in-stent restenosis were first treated with conventional catheter-based techniques and then randomized (blinded) to receive either gamma-irradiation ((192)Ir) or a placebo (dummy seeds). We identified all patients in whom the active (n=19) or dummy seeds (n=19) extended >10 mm proximal and distal to the in-stent restenosis lesion. Serial (postirradiation and follow-up) external elastic membrane (EEM), lumen, and plaque and media (EEM-lumen) areas were measured (using intravascular ultrasound) every 1 mm over 5-mm-long reference segments that were 6 to 10 mm proximal and distal to the in-stent restenosis lesion. During follow-up, a similar small increase occurred in the plaque and media area in the proximal and distal reference segments in both (192)Ir and placebo patients. However, in the (192)Ir patients, an increase in both proximal and distal EEM area occurred; as a result, no change in lumen area occurred. Conversely, in the placebo patients, the proximal reference EEM area decreased, and no change occurred in the distal reference EEM area; this contributed to a decrease in lumen area. CONCLUSIONS: There was no evidence of a deleterious effect of gamma-irradiation on angiographically normal uninjured reference segments in the first 6 months after the treatment of in-stent restenosis.

Coronary Disease↗

Intracoronary gamma-radiation therapy after angioplasty inhibits recurrence in patients with in-stent restenosis.

BACKGROUND: Treatment of in-stent restenosis presents a critical limitation of intracoronary stent implantation. Ionizing radiation has been shown to decrease neointimal formation within stents in animal models and in initial clinical trials. We studied the effects of intracoronary gamma-radiation therapy versus placebo on the clinical and angiographic outcomes of patients with in-stent restenosis. METHODS AND RESULTS: One hundred thirty patients with in-stent restenosis underwent successful coronary intervention and were then blindly randomized to receive either intracoronary gamma-radiation with (192)Ir (15 Gy) or placebo. Four independent core laboratories blinded to the treatment protocol analyzed the angiographic and intravascular ultrasound end points of restenosis. Procedural success and in-hospital and 30-day complications were similar among the groups. At 6 months, patients assigned to radiation therapy required less target lesion revascularization and target vessel revascularization (9 [13.8%] and 17 [26.2%], respectively) compared with patients assigned to placebo (41 [63.1%, P=0.0001] and 44 [67.7%, P=0.0001], respectively). Binary angiographic restenosis was lower in the irradiated group (19% versus 58% for placebo, P=0.001). Freedom from major cardiac events was lower in the radiation group (29.2% versus 67.7% for placebo, P<0.001). CONCLUSIONS: Intracoronary gamma-radiation used as adjunct therapy for patients with in-stent restenosis significantly reduces both angiographic and clinical restenosis.

Aged↗

Prognostic value of cardiac troponin-I levels following catheter-based coronary interventions.

This study has examined the prognostic significance of troponin-I (Tn-I) levels after catheter-based coronary interventions in coronary arteries and saphenous vein grafts lesions. Tn-I and creatine kinase-MB (CK-MB) fraction levels were measured at 6 and 18 to 24 hours after catheter-based coronary intervention in 1,129 consecutive patients with normal preintervention plasma levels of Tn-I, and CK-MB levels below the cutoff for myocardial infarction. Patients were stratified according to maximal postangioplasty Tn-I levels. Group I (n = 784) had no elevated Tn-I (<0.15 ng/ml), group II (n = 170) had Tn-I at 0.15 to 0.45 ng/ml, and group III (n = 175) had Tn-I elevation >0.45 ng/ml. Major in-hospital complications (death, 0-wave infarction, and emergent coronary bypass grafting) and out-of-hospital intermediate-term (8 months) outcomes were compared between the 3 groups. Tn-I elevation >0.45 ng/ml was associated with increased risk of mortality (group III, 1.6%; group II, 0.6%; and group I, 0.1%; p = 0.019) and major in-hospital complications (3.2%, 1.7%, and 0.5%; p = 0.004). There was no difference in death (1.8%, 3.2%, and 2.4%; p = 0.74), Q-wave infarction (0.6%, 0%, and 0.3%; p = 0.66), or target lesion revascularization (10.1%, 9.0%, and 9.3%; p = 0.86) between the 3 groups at follow-up. Cardiac event-free survival was similar between groups (p = 0.3). By multivariate analysis, Tn-I >0.45 ng/ml was an independent predictor for major in-hospital complications (odds ratio 2.1, 95% confidence interval 1.2 to 3.9, p = 0.01). The degree of risk was also associated with the conjoint elevation of Tn-I and CK-MB levels (odds ratio 1.1, 95% confidence interval 1.02 to 1.2, p = 0.01). We conclude that Tn-I levels >3 times the normal limit and conjoint elevation of Tn-I and CK-MB levels after coronary angioplasty are associated with increased risk of major in-hospital complications, but have no incremental risk of adverse intermediate-term (8 months) clinical outcomes.

Aged↗

Intracoronary beta-radiation therapy inhibits recurrence of in-stent restenosis.

BACKGROUND: Intracoronary gamma-radiation therapy reduces recurrent in-stent restenosis (ISR). This study, BETA WRIST (Washington Radiation for In-Stent restenosis Trial) was designed to examine the efficacy and safety of the beta-emitter 90-yttrium for the prevention of recurrent ISR. METHODS AND RESULTS: A total of 50 consecutive patients with ISR in native coronaries underwent percutaneous transluminal coronary angioplasty, laser angioplasty, rotational atherectomy, and/or stent implantation. Afterward, a segmented balloon catheter was positioned and automatically loaded with a 90-yttrium, 0.014-inch source wire that was 29 mm in length to deliver a dose of 20.6 Gy at 1.0 mm from the balloon surface. In 17 patients, manual stepping of the radiation catheter was necessary for lesions >25 mm in length. The radiation was delivered successfully to all patients, with a mean dwell time of 3.0+/-0.4 minutes. Fractionation of the dose due to ischemia was required in 11 patients. At 6 months, the binary angiographic restenosis rate was 22%, the target lesion revascularization rate was 26%, and the target vessel revascularization rate was 34%; all rates were significantly lower than those of the placebo group of gamma-WRIST. CONCLUSIONS: beta-Radiation with a 90-yttrium source used as adjunct therapy for patients with ISR results in a lower-than-expected rate of angiographic and clinical restenosis.

Adult↗