Search PubMed⌕ Search

Biomedical subjects

M B Leon

Publications and source records attributed to M B Leon.

At least 307 records · Page 17Linked to original sources

Effect of intracoronary stenting on intimal dissection after balloon angioplasty: results of quantitative and qualitative coronary analysis.

The effect of the Palmaz-Schatz stent on the angiographic appearance and residual luminal stenosis in patients with intimal dissection after balloon angioplasty was evaluated in 84 consecutive patients (90 lesions). Coronary angiography was performed before angioplasty, after conventional angioplasty and after stent implantation. The degree of intimal disruption was assessed as follows: grade 0, no dissection; grade 1, simple dissection (intraluminal linear defect or extraluminal cap extravasation); or grade 2, complex dissection (nonlinear spiral defect or luminal defect with multiple irregular borders). Quantitative coronary analysis of digitized cineangiograms was performed with use of a computerized automatic edge detection algorithm. After balloon angioplasty, 31 (34%) of 90 lesions demonstrated intimal dissection (18 simple, 13 complex). After stent implantation, intimal dissection improved by greater than or equal to 1 grade in 29 (94%) of the 31 lesions with 27 (87%) reduced to grade 0 (that is, no dissection). Dissection grade improved after stenting in 16 (89%) of 18 simple dissections and in all 13 complex dissections. Mean diameter stenosis was 77 +/- 17% before angioplasty, 47 +/- 17% after angioplasty and 14 +/- 10% after stenting (before angioplasty vs. after angioplasty and after angioplasty vs. after stenting, p less than 0.0001). In conclusion, intracoronary stenting is effective in reducing the residual luminal stenosis and in improving the angiographic appearance of intimal dissections after conventional balloon angioplasty.

Adult↗

Sudden death during empiric amiodarone therapy in symptomatic hypertrophic cardiomyopathy.

Amiodarone is reported to improve symptoms and to prevent sudden death in patients with hypertrophic cardiomyopathy (HC). Amiodarone treatment (loading dose 30 g given over 6 weeks; maintenance dose 400 mg/day) was prospectively evaluated in 50 patients with HC in whom the drug was initiated because of symptoms refractory to conventional drug therapy (calcium antagonists and beta blockers). Twenty-one (42%) patients had ventricular tachycardia (VT) during Holter monitoring. Amiodarone significantly and often markedly improved the patients' New York Heart Association functional class status (from 3.3 to 2.7 at 2 months, p less than 0.001) and treadmill exercise duration (p less than 0.001). Eight patients, however, died (7 suddenly) during a mean follow-up period of 2.2 +/- 1.8 years. Of the 7 sudden deaths, 6 occurred within 5 months of initiation of treatment. The 6-month and 1- and 2-year survival rates were 87, 85 and 80%, respectively. The survival rate of patients with VT was significantly worse than that of patients without VT (61 vs 97% at 2 years; p less than 0.01). Sudden death occurred despite abolition of VT on Holter monitoring. Amiodarone increased left ventricular peak filling rate by radionuclide angiography in 20 of 33 patients (61%) (p less than 0.01). Decrease in peak left ventricular filling rate within 10 days of amiodarone therapy (8 of 33 patients) was associated with subsequent sudden death (p less than 0.04).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

In vivo human atherosclerotic plaque recognition by laser-excited fluorescence spectroscopy.

Arterial wall perforation and chronic restenosis represent important factors limiting the clinical application of laser angioplasty. Discrimination of normal and atherosclerotic vessels by laser-excited fluorescence spectroscopy may offer a means of targeting plaque ablation, thereby reducing the frequency of restenosis and transmural perforation. In this study, with use of a 325 nm low power helium-cadmium laser, in vivo endogenous surface fluorescence was excited through a flexible 200 microns optical fiber within a 0.018 in. (0.046 cm) guide wire in contact with the intima of 268 vascular interrogation sites from 48 patients either during open heart surgery or during percutaneous catheterization procedures. Fluorescence spectra could be recorded in all patients in bloodless and blood-filled arteries. Endogenous surface fluorescence was analyzed measuring peak intensity, peak position and shape index of the spectra. Compared with normal wall, noncalcified and calcified coronary atheroma showed a 42% (p less than 0.001) and a 58% (p less than 0.001) decrease of peak intensity, and higher shape index (p less than 0.001 and p less than 0.01, respectively). In addition, peak position was shifted to longer wavelengths for noncalcified coronary atheroma (p less than 0.001). Compared with normal aorta sites, aortic plaques demonstrated a 46% decrease of peak intensity, longer peak position wavelengths (p less than 0.05) and a higher shape index (p less than 0.001). Using an atheroma detection algorithm, prospective analysis of aorta and coronary spectra showed a specificity of 100% for identifying normal sites and a sensitivity of 73% for recognizing atherosclerotic sites.(ABSTRACT TRUNCATED AT 250 WORDS)

Adolescent↗

Occlusive peripheral vascular disease: a multicenter trial of fluorescence-guided, pulsed dye laser-assisted balloon angioplasty.

Fluorescence-guided, laser-assisted balloon angioplasty was performed in 129 patients with iliac and femoropopliteal artery chronic occlusions (range, 0.5-50.0 cm; mean length, 9.9 cm) after failure of recanalization with standard guide-wire techniques. Laser recanalization and short-term angiographic success were achieved in 101 (72%) and 95 (68%) of 140 occlusions, respectively. Laser and balloon angioplasty failures were encountered in heavily calcified plaques or after perforations and dissections. Complications included perforations (19%), hematomas (5%), thromboses (4%), and distal embolizations (4%). Real-time fluorescence spectroscopy identified thrombus, white fibrous plaque, and media but could not avoid perforations in many cases because laser wire advancement outdistanced fluorescence sensing. Disruption of tissue by means of pressure transients and/or mechanical advancement occurred in at least 36% of lesions where the laser energy was insufficient (less than 0.4 J/cm) to ablate significant tissue. Integration of fluorescence guidance with pulsed dye laser ablation is feasible, but additional refinements are necessary to increase safety and efficacy.

Adult↗

Intravascular ultrasound imaging: in vivo peripheral and coronary artery studies.

Recent in vitro studies have demonstrated that intravascular ultrasound can obtain high-resolution cross-sectional images of arterial vessels. To further expand the use of this technique for in vivo visualization of peripheral and coronary vessels, we imaged 24 femoral and 13 carotid arteries from 19 sheep. Using a manual rotation technique, high-resolution images were obtained in 95% of the vessel sites with a rigid probe and in 82% of the vessel sites with a flexible catheter. In 14 of these arteries, good correlation was found between the lumen diameter measured by ultrasound and by angiography (P less than .001, r = .91). In addition, 6 left circumflex coronary arteries were imaged from 6 additional sheep by motor-driven rotation of the ultrasound probe at 1,800 rotations per minute, obtaining clear delineation of coronary lumen morphology and lumen-intima interface. Strong correlation was found also between intravascular ultrasound and cineangiography for coronary artery diameter measurement (P less than .001, r = .96). These studies demonstrate that this technique can provide high-resolution images of arterial vessels in vivo and may have unique advantages in diagnosis of atherosclerotic vascular disease and in the guidance of new catheter-based therapeutic modalities.

Animals↗

Intravascular ultrasonography: validation studies and preliminary intraoperative observations.

Intravascular ultrasonography is emerging as an important imaging modality to assess the presence, distribution, and extent of atherosclerotic vascular disease. To determine the accuracy and clinical utility of intravascular ultrasonography, a flexible catheter-based system was used to generate two-dimensional, cross-sectional vascular images. In 23 arteries of 11 sheep 206 in vivo images demonstrated an echo-free lumen surrounded by three distinct concentric acoustic transitions corresponding to intima, media, and adventitia. Ultrasound measurements of lumen diameter and area correlated significantly with those of corresponding arteriographic measurements obtained by use of digital calipers (r = 0.91, r = 0.86). To evaluate clinical feasibility, intraoperative images (n = 160) were obtained in 10 patients undergoing vascular bypass or hemodialysis access procedures. The images depicted luminal configuration and arterial wall morphologic characteristics. Measurements of lumen diameter and lumen area correlated closely with corresponding intraoperative arteriography (r = 0.81, r = 0.79). The ultrasound images demonstrated arterial stenoses, intimal hyperplasia, intraluminal thrombus, polytetrafluoroethylene graft material, and anastomotic sites. We conclude that flexible catheter-based ultrasonography produces images that accurately demonstrate arterial wall architecture, lumen diameter, and area. Intraoperative application can produce images that provide unique information thus expanding the clinical potential of ultrasonography as a guidance system for vascular procedures.

Animals↗

Enhanced detection of ischemic but viable myocardium by the reinjection of thallium after stress-redistribution imaging.

BACKGROUND: The identification of ischemic but viable myocardium by thallium exercise scintigraphy is often imprecise, since many of the perfusion defects that develop in ischemic myocardium during exercise do not "fill in" on subsequent redistribution images. We hypothesized that a second injection of thallium given after the redistribution images were taken might improve the detection of ischemic but viable myocardium. METHODS: We studied 100 patients with coronary artery disease, using thallium exercise tomographic imaging and radionuclide angiography. Patients received 2 mCi of thallium intravenously during exercise, redistribution imaging was performed three to four hours later, and a second dose of 1 mCi of thallium was injected at rest immediately thereafter. The three sets of images (stress, redistribution, and reinjection) were then analyzed. RESULTS: Ninety-two of the 100 patients had exercise-induced perfusion defects. Of the 260 abnormal myocardial regions identified by stress imaging, 85 (33 percent) appeared to be irreversible on redistribution imaging three to four hours later. However, 42 of these apparently irreversible defects (49 percent) demonstrated improved or normal thallium uptake after the second injection of thallium, with an increase in mean regional uptake from 56 +/- 12 percent on redistribution studies to 64 +/- 10 percent on reinjection imaging (P less than 0.001). Twenty patients were restudied three to six months after coronary angioplasty. Of the 15 myocardial regions with defects on redistribution studies that were identified as viable by reinjection studies before angioplasty, 13 (87 percent) had normal thallium uptake and improved regional wall motion after angioplasty. In contrast, all eight regions with persistent defects on reinjection imaging before angioplasty had abnormal thallium uptake and abnormal regional wall motion after angioplasty. CONCLUSIONS: These data indicate that the reinjection of thallium improves the detection of ischemic myocardium and that myocardial regions with improved thallium uptake on reinjection imaging represent viable but jeopardized myocardium.

Adult↗

Balloon expandable stent implantation in stenotic right heart valved conduits.

Although valved conduits have been used successfully in severe forms of right ventricular-pulmonary artery discontinuity, progressive valved conduit stenosis is an important clinical problem. To determine the feasibility of reducing right heart valved conduit stenosis with a balloon expandable stent, a baboon model was used, in which the pulmonary artery was ligated and a right ventricular to pulmonary artery 14 mm bioprosthetic Dacron valved conduit implanted. In five baboons, at an average of 40 months after valved conduit implantation, fibrointimal stenosis at the valve site resulted in narrowing and a mean transconduit pressure gradient of 49 mm Hg (range 33 to 65). A tubular slotted steel stent (1.2 cm long) was deployed within the valved conduit after inflation of an 8 to 15 mm diameter balloon catheter that was introduced through the femoral vein. A stent was delivered to all valved conduits; however, in two baboons, balloon undersizing resulted in stent dislodgment. In the remaining three baboons, the transconduit gradient was reduced by 59% (49 to 20 mm Hg) and right ventricular systolic pressure decreased acutely by 35% (77 to 50 mm Hg). It is concluded that stent deployment is feasible in right ventricular to pulmonary artery stenotic valved conduits and may result in significant hemodynamic improvement. However, successful stent delivery is critically dependent on the proper selection of stent length and balloon diameter.

Animals↗

Plaque characterization of atherosclerotic coronary arteries by intravascular ultrasound.

Intravascular ultrasound provides cross-sectional images of arteries and enables accurate delineation of lumen dimensions and wall structure. Moreover, ultrasound characterization of atherosclerotic plaque subtypes may have important implications in determining the natural history and the clinical outcome of patients with coronary artery disease. The reliability of intravascular ultrasound to differentiate plaque morphology subtypes was studied in 60 coronary segments excised from 33 coronary arteries obtained from 17 patients at necropsy. Ultrasound was performed with a 25-MHz transducer mounted on the distal end of a rigid probe that was rotated manually inside the lumen artery. Plane film radiography was also performed to establish the presence of calcific deposits. A total of 82 histologic transverse sections corresponding to 82 ultrasound imaging sites were studied from the 60 coronary segments. Of the first 54 images, 36 were fibrous plaques and yielded dense homogenous echo reflections, 6 had discrete areas of lipid that were less echogenic and 12 had calcific deposits that cast echo-free shadows beyond areas of intense echo reflections. The predictive accuracy of evaluating plaque composition in the remaining 28 ultrasound imaging sites was 96%. Thus, anatomical structure of coronary arteries and composition of atherosclerotic lesions can be assessed accurately with intravascular ultrasound and may have potential for better understanding of the atherosclerotic process and provide guidance to interventional procedures.

Aged↗

Fluorescence-guided laser-assisted balloon angioplasty in patients with femoropopliteal occlusions.

In 12 patients (aged 64 +/- 10 years) with femoropopliteal occlusions (1-27 cm; average, 8.4 cm length) that could not be recanalized by standard guidewire-balloon angioplasty techniques, percutaneous laser-assisted balloon angioplasty was performed by use of a new fluorescence-guided dual-laser system. Plaque detection by 325-nm laser-excited fluorescence spectroscopy provided real-time feedback control to a 480-nm pulsed dye laser (2-microseconds pulses) for atheroma ablation. By means of a common 200-microns optical fiber, after diagnostic fluorescence sensing, computer algorithms directed a fire or no-fire signal (5 Hz) to the treatment laser for selective plaque removal. Laser recanalization (15-50 mJ/pulse) was successful in 10 of 12 patients; this procedure was followed by definitive balloon angioplasty in seven of 12 patients with increased ankle/arm indexes (from 0.60 +/- 0.12 at baseline to 0.84 +/- 0.11 after treatment, p = 0.0043). In laser and balloon angioplasty failures, all femoropopliteal occlusions were heavily calcified, and there were two mechanical guidewire perforations without clinical sequelae. Ablation of calcified lesions required higher pulse energies and greater total energy per centimeter of recanalized tissue (1,837 +/- 1,251 mJ/cm vs. 90 +/- 39 mJ/cm, p = 0.0036). Fluorescence spectroscopy (n = 219 sites) was helpful in flush occlusions and correctly identified plaque, underlying media, and thrombus by changes in fluorescence intensity, shape, and peak position. Thus, when fluorescence-guided laser angioplasty was used in a subgroup of patients refractory to standard angioplasty techniques, primary recanalization and subsequent balloon angioplasty of femoropopliteal occlusions was successful in 83% and 58% of the patients, respectively. Importantly, treatment of heavily calcified lesions accounted for all of the failures and will require modified delivery systems to create larger primary channels and to increase catheter-tip control, which should improve clinical results in the future.

Adult↗

Coronary artery imaging with intravascular high-frequency ultrasound.

Safe and effective clinical application of new interventional therapies may require more precise imaging of atherosclerotic coronary arteries. To determine the reliability of catheter-based intravascular ultrasound as an imaging modality, a miniaturized prototype ultrasound system (1-mm transducer; center frequency, 25 MHz) was used to acquire two-dimensional, cross-sectional images in 21 human coronary arteries from 13 patients studied at necropsy who had moderate-to-severe atherosclerosis. Fifty-four atherosclerotic sites imagined by ultrasound were compared with formalin-fixed and fresh histological sections of the coronary arteries with a digital video planimetry system. Ultrasound and histological measurements correlated significantly (all p less than 0.0001) for coronary artery cross-sectional area (r = 0.94), residual lumen cross-sectional area (r = 0.85), percent cross-sectional area (r = 0.84), and linear wall thickness (plaque and media) measured at 0 degrees, 90 degrees, 180 degrees, and 270 degrees (r = 0.92). Moreover, ultrasound accurately predicted histological plaque composition in 96% of cases. Anatomic features of the coronary arteries that were easily discernible were the lumen-plaque and media-adventitia interfaces, very bright echoes casting acoustic shadows in calcified plaques, bright and homogeneous echoes in fibrous plaques, and relatively echo-lucent images in lipid-filled lesions. These data indicate that intravascular ultrasound provides accurate image characterization of the artery lumen and wall geometry as well as the presence, distribution, and histological type of atherosclerotic plaque. Thus, ultrasound imaging appears to have great potential application for enhanced diagnosis of coronary atherosclerosis and may serve to guide new catheter-based techniques in the treatment of coronary artery disease.

Adult↗

Platelet adherence and thrombus formation with flowing human blood on atherosclerotic plaque: reduced thrombogenicity of Watanabe-heritable hyperlipidemic rabbit aortic subendothelium.

Platelet adherence and aggregation are important in the development of ischemic sequelae in atherosclerosis. To directly examine platelet interaction with plaque, everted, deendothelialized aortic fibrous plaques from Watanabe-heritable hyperlipidemic rabbits were exposed to flowing human blood in an annular perfusion chamber. Morphometry was used to compare platelet adherence and thrombi on this surface with that observed when blood was perfused over normal New Zealand White (NZW) rabbit aortic subendothelium. Platelet spreading, adherence, and thrombi on the atherosclerotic surface were approximately half that observed on NZW aorta. When surface proteins of NZW aorta were denatured by a hot-tip catheter, these parameters were reduced by 89-96%. The reduced thrombogenicity of uncomplicated plaques may help keep these narrowed vessels patent, while fissure, rupture, or hemorrhagic dissection of plaque may precipitate occlusive thrombosis.

Animals↗

An in vivo feasibility study of intravascular ultrasound imaging.

Increasingly complex vascular reconstructions and emerging endovascular therapeutic modalities have stimulated the need for improved vascular imaging. To determine the feasibility of in vivo intravascular ultrasound, a miniature probe 1 mm in diameter with a 25 MHz center frequency was used to obtain two-dimensional, 360-degree cross-sectional images. In sheep, 14 superficial femoral arteries were imaged at different sites, and a portion of each vessel was resected for immediate in vitro imaging and histologic examination. In vivo images clearly showed the intima, media, and adventitia of the vessel wall as well as the lumen-intima and media-adventitia interfaces. There was a significant correlation in measured lumen area between resected artery ultrasound images and histologic sections. We conclude that intravascular ultrasound can produce high-resolution dynamic images that demonstrate vessel wall architecture and allow precise calculation of lumen area.

Animals↗

Clinical and hemodynamic results after mitral valve replacement in patients with obstructive hypertrophic cardiomyopathy.

Mitral valve replacement has been performed in patients with obstructive hypertrophic cardiomyopathy if: (1) the interventricular septum is smaller than 18 mm in the region of usual resection; (2) atypical septal morphology is encountered; (3) a previous left ventricular myomectomy has been performed but residual major obstruction and symptoms persist; or (4) intrinsic mitral valve disease exists. Since 1983, mitral valve replacement has been performed in 58 patients with obstructive HCM only. Thirty-three female patients (mean age, 47.9 years) and 25 men (mean age, 45.7 years) met criteria 1 through 3 for mitral valve replacement. Patients with intrinsic mitral valve disease (criterion 4) were omitted from this study. All patients were in New York Heart Association functional class III or IV and had failed optimal medical therapy. Low-profile mechanical prostheses and bioprostheses were implanted, and the early mortality (less than 30 days or in the hospital) was 8.6% (5/58). Six patients (11.3%) died late, 3 suddenly of probably arrhythmia, 2 of respiratory failure, and 1 of an anticoagulant-related complication. After mitral valve replacement, 40 (83%) of 48 patients surviving operation and returning for evaluation were in functional class I or II, whereas 8 patients were in functional class III. Hemodynamic data obtained 6 months postoperatively showed that pulmonary artery wedge pressure was normal (13.7 +/- 4 mm Hg [+/- standard deviation]), left ventricular end-diastolic pressure had decreased (10.9 +/- 3.4 mm Hg), cardiac index was maintained (2.6 +/- 0.6 L/min/m2), and resting and provoked gradients were unremarkable. Mean follow-up was 24.2 months, actuarial survival was 86% at 3 years, and survival free from thromboembolism, anticoagulant-related complication, reoperation, and congestive heart failure for the same interval was 68%. Complications such as ventricular septal defect and complete heart block are avoided in patients undergoing mitral valve replacement, but device-related and cardiac-related complications can add to the morbidity and mortality in these patients in the long term.

Adult↗

Comparative effects of verapamil and nitroprusside on left ventricular function in patients with hypertension.

The effects of verapamil were compared with those of nitroprusside at matched mean arterial pressures and heart rates in 10 symptomatic hypertensive patients during cardiac catheterization. Simultaneous radionuclide angiography and micromanometer pressure measurements were obtained to assess left ventricular pressure-volume relations. Compared with control conditions, verapamil increased left ventricular end-diastolic volume index from 57 +/- 16 to 70 +/- 28 ml/m2 (p = 0.05) without a significant increase in left ventricular end-diastolic pressure (from 10 +/- 4 to 13 +/- 6 mm Hg). Despite a downward and rightward shift in the end-systolic pressure-volume relation indicating negative inotropic effects, ejection fraction did not decrease significantly (from 52 +/- 9% to 46 +/- 9%); cardiac index and stroke volume index remained unchanged. The change in stroke volume index with verapamil was directly related to the magnitude of change in end-diastolic volume index (r = 0.82, p less than 0.005), suggesting that the increase in end-diastolic volume did not arise purely from negative inotropic effects. Systemic vascular resistance index decreased from 42 +/- 8 to 34 +/- 7 mm Hg.min.m2/liter (p less than 0.05). In contrast, nitroprusside decreased left ventricular end-diastolic volume index from 57 +/- 16 to 41 +/- 10 ml/m2 (p less than 0.05), cardiac index from 3.2 +/- 0.7 to 2.8 +/- 0.6 liters/min per m2 (p less than 0.05) and stroke volume index from 28 +/- 6 to 24 +/- 5 ml/m2 (p less than 0.01), with no change in systemic vascular resistance index (40 +/- 10 mm Hg.min.m2).(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗

Amiodarone-induced complications after cardiac operation for obstructive hypertrophic cardiomyopathy.

The occurrence of unanticipated and seemingly unexplicable major complications of hepatic, pulmonary, and cardiac dysfunction after palliative operation for obstructive hypertrophic cardiomyopathy prompted a review of 71 sequential patients. Fifty-five patients had been treated preoperatively with beta-blockers, calcium-channel inhibitors, or both, and 16 had received amiodarone for six to 566 days (mean time, 210 days) at total doses ranging from 8 to 175 g (mean dose, 82 g) and had drug-free intervals prior to operation of zero to 457 days (mean time, 91 days). Comparisons were made between the two treatment groups and between those with and without major complications within the amiodarone-treated group. Preoperative cardiac studies, sex, age, functional class, and type of operation were not related to outcome for the entire patient cohort. In amiodarone-treated patients, the major findings were as follows: a 50% incidence of hepatic dysfunction with a tenfold increase in concentrations of serum glutamic-oxaloacetic transaminase and serum glutamic-pyruvic transaminase; a 25% incidence of pulmonary dysfunction necessitating a fourfold increase in the number of days of ventilator support; and a 19% incidence of low cardiac output syndrome with two deaths. Only 44% of the amiodarone-treated group had no serious complications. The incidence of major complications of the liver, lungs, and heart was 2%, 0%, and 2%, respectively, in patients not treated with amiodarone. Abnormal preoperative pulmonary function studies were predictive of prolonged postoperative ventilatory support. Discontinuation of amiodarone for several months prior to operation appeared to reduce the incidence of major complications. The necessary drug-free interval required preoperatively could not be determined from this retrospective experience.(ABSTRACT TRUNCATED AT 250 WORDS)

Adult↗