Search PubMed⌕ Search

Biomedical subjects

M B Leon

Publications and source records attributed to M B Leon.

At least 235 records · Page 13Linked to original sources

Comparison of clinical and angiographic outcomes after saphenous vein graft angioplasty using coronary versus 'biliary' tubular slotted stents.

BACKGROUND: Saphenous vein graft (SVG) angioplasty using 15-mm articulated, tubular slotted stents results in low (0% to 20%) residual diameter stenoses and infrequent (< 5%) major complications. A "biliary" stent design with greater radial compressive strength, enhanced visibility, and more variable sizing (diameter and length) has been approved for noncoronary indications. A comparison of outcomes after coronary versus biliary stent placement in SVG stenoses has not been performed. The purpose of this study was to compare the angiographic and clinical results after SVG angioplasty using these two balloon-expandable, tubular slotted stent designs. METHODS AND RESULTS: During a 3-year period, 231 patients with 305 SVG lesions were treated using Palmaz-Schatz coronary (n = 108) or biliary (n = 123) stents. Cineangiograms were reviewed using qualitative morphological and quantitative angiographic methods. Time-dependent clinical outcome (freedom from death, Q-wave myocardial infarction, or the need for repeat coronary bypass surgery or SVG angioplasty) was assessed using Kaplan-Meier life-table methods. Unstable angina (P < .001) and recent myocardial infarction (P = .001) were present more often in patients undergoing biliary stent versus coronary stent placement. Biliary stent-treated SVG lesions were more frequently de novo (P = .001), ostial in location (P = .002), > or = 10 mm in length (P = .009), thrombus containing (P = .001), and ulcerated (P < .001) than coronary stent-treated SVG lesions. Angiographically, biliary stent-treated lesions had larger reference vessel diameter (3.43 +/- 0.59 mm versus 3.10 +/- 0.64 mm, P < .001), higher balloon-to-artery ratio (1.15 +/- 0.16 mm versus 1.07 +/- 0.19, P = .0001), and lower residual diameter stenosis (6 +/- 17% versus 14 +/- 11% in coronary stent-treated patients; P < .001). Procedural success rates were high (95%), in-hospital major complications were uncommon (< 3%), and follow-up clinical outcomes were favorable (6-month event-free survival approximately 80%) in both groups. CONCLUSIONS: Despite frequent short-term ischemic syndromes and unfavorable lesion characteristics, both biliary and coronary cohorts have similarly favorable short-term procedural results and long-term clinical outcomes. The increased strut thickness of the biliary stent confers greater fluoroscopic visibility and radial compressive strength in exchange for decreased stent flexibility and added technical demand in stent deployment. Extreme caution is recommended with biliary stent placement in the treatment of SVG lesions as clinical results are highly operator dependent.

Aged↗

Localized drug delivery in atherosclerotic arteries via a new balloon angioplasty catheter with intramural channels for simultaneous local drug delivery.

A dual-purpose angioplasty catheter with intramural channels and exterior pores for local drug delivery ("channeled balloon") was studied in eight atherosclerotic human necropsy arteries and in 22 rabbits with atherosclerotic peripheral arteries, in which markers (0.005 microns to 15 microns) were infused locally at 2 atmospheres during simultaneous angioplasty at 6 atmospheres. Thirteen of the rabbits were sacrificed at 4 or 24 h after procedure to determine the intramural retention over time. Histology confirmed effective angioplasty and revealed presence of markers in the arterial wall in 29 of 43 treated arteries (67%), whereas all control segments without local delivery had no marker staining. majority of the ineffective local delivery (12/14) occurred when 15 micron particles were infused (12/13 arteries without intramural markers), especially when examined 4 or 24 h later. Thus, in atherosclerotic arteries, the channeled balloon enabled simultaneous local drug delivery at low pressure during effective angioplasty, although particle size may play a role in successful intramural impregnation and retention.

Angioplasty, Balloon↗

Transluminal extraction catheter for the treatment of diseased saphenous vein grafts: a multicenter experience.

To evaluate the efficacy, safety, and long-term results of atherectomy using the Transluminal Extraction catheter (TEC), patients with diseased saphenous vein grafts were enrolled in a prospective nonrandomized trial. Patients were followed to hospital discharge for acute complications and underwent routine 6-mo reevaluation with repeat cardiac catheterization to assess restenosis. Atherectomy was performed on 650 graft lesions in 538 consecutive patients (male 81%; mean age 66 yr; range 37-81). Mean graft age was 8.3 yr; (range 0.3-20) with 85% of grafts > 3 yr of age. Complex lesion morphology included thrombus (28%), ulceration (13%), and eccentricity (50%). Lesion success was achieved in 606 lesions (93%) with clinical success in 479 patients (89%). Lesion success was achieved in 90% of thrombus containing lesions, 97% of ulcerated lesions, and 97% of grafts > 3 yr. Complications included nonfatal myocardial infarction in 4 (0.7%) of patients, emergency bypass surgery in 2 (0.41%), and in-hospital death in 17 patients (3.2%). Angiographic follow-up at 6 mo was obtained from 268 lesions in 227 patients. The overall lesion angiographic restenosis rate was 60%. TEC atherectomy can be performed in patients with diseased saphenous vein grafts with high primary success and low complication rates. It is suitable for use in aged grafts, particularly in the presence of thrombus and ulcerations, and may be superior to balloon angioplasty alone in this group of patients.

Adult↗

Can coronary flow parameters after stent placement predict restenosis?

Intracoronary stent was used to treat a dissection resulting from balloon angioplasty. Coronary flow parameters measured with Doppler Flowire pre- and post-stenting suggested abnormal coronary flow even after stenting. The patient returned 4 months later with an instent restenosis. This case suggests the intriguing possibility of coronary flow parameters obtained immediately after new device angioplasty in predicting restenosis.

Aortic Dissection↗

Vascular effects of diet-induced hypercalcemia after balloon artery injury in giant Flemish rabbits.

To determine whether metastatic calcification during neointima formation can result in neointimal calcification that simulates advanced human atherosclerosis, 32 giant Flemish rabbits (weight 5.5 +/- 0.6 kg) underwent overstretch balloon injury of bilateral iliac arteries and received diet therapy for 8 weeks: high cholesterol (2%) and low calcium-vitamin D2 regimen (250 mg of calcium carbonate orally 5 times weekly and 50,000 U of calciferol intramuscularly 3 times weekly; group 1; n = 5); low cholesterol (0.5%) and high calcium-vitamin D2 regimen (500 mg of calcium carbonate orally 5 times weekly and 100,000 U of calciferol intramuscularly three times weekly; group 2; n = 19); or 0% cholesterol and high calcium-vitamin D2 regimen (group 3; n = 8). The incidence of vascular calcification was highest (71.4%) in group 2. Eighty-one percent of calcification was medial. Residual strain measurements of 7 thoracic aortas from group 2 compared to normal thoracic aortas from 8 control rabbits showed that residual strain was significantly increased in the calcified atherosclerotic aortas (12.3% vs 5.2%; p = 0.001). We conclude that diet-induced hypercalcemia predominantly affects the media despite the presence of concomitant neointima formation from balloon artery injury with or without hypercholesterolemia and increases the residual strain more than twofold compared to normal thoracic aortas.

Animals↗

Multivariate predictors of intravascular ultrasound end points after directional coronary atherectomy.

OBJECTIVES: This study attempted to identify the clinical, angiographic, procedural and intravascular ultrasound predictors of directional atherectomy results assessed by intravascular ultrasound. BACKGROUND: Several angiographic and intravascular ultrasound variables have been associated with the outcome of directional coronary atherectomy. No study has incorporated both modalities into a predictive model. METHODS: One hundred seventy patients were analyzed using preintervention and postintervention intravascular ultrasound and quantitative angiography. Clinical and procedural variables were collected by independent chart review. Quantitative and qualitative angiographic analysis was performed by a core laboratory in blinded manner. Intravascular ultrasound was performed using a transducer-tipped catheter, rotating within a stationary imaging sheath, and withdrawn automatically at 0.5 mm/s. Clinical, procedural, angiographic and ultrasound variables were tested in a multivariate linear regression model. Dependent ultrasound variables included postatherectomy lumen cross-sectional area and percent cross-sectional narrowing (plaque plus media/external elastic membrane cross-sectional area) and, in a subgroup of 47 patients studied using volumetric analysis, percent plaque volume removal. RESULTS: By multivariate stepwise linear regression analysis, predictors of residual lumen cross-sectional area (correcting for reference lumen area) included arc of calcium and preatherectomy plaque plus media cross-sectional area; predictors of residual cross-sectional narrowing were arc of calcium, preatherectomy plaque plus media cross-sectional area and lesion length; and predictors of percent plaque volume removal were arc of calcium and atherectomy device size. CONCLUSIONS: The preintervention lesion arc of calcium measured by intravascular ultrasound is the most consistent predictor of the effectiveness and results of directional coronary atherectomy.

Atherectomy, Coronary↗

Atherosclerosis in angiographically "normal" coronary artery reference segments: an intravascular ultrasound study with clinical correlations.

OBJECTIVES: This study evaluated the magnitude, patterns and clinical correlates of atherosclerosis in angiographically "normal" reference segments in patients undergoing transcatheter therapy for symptomatic coronary artery disease. BACKGROUND: Pathologic studies indicate that the extent of coronary atherosclerosis is underestimated by visual analysis of angiographically normal coronary artery segments. Intravascular ultrasound allows detailed, high quality cross-sectional imaging of the coronary arteries in vivo. METHODS: Intravascular ultrasound was used to study angiographically normal coronary artery reference segments in 884 patients evaluated for transcatheter therapy for symptomatic native coronary artery disease. The reference segment was the most visually normal intravascular ultrasound cross section within 10 mm proximal to the target lesion but distal to any major side branch. Results are presented as mean value +/- 1 SD. RESULTS: Only 60 (6.8%) of 884 angiographically normal reference segments were normal by intravascular ultrasound. Reference segment percent cross-sectional narrowing measured 51 +/- 13% and correlated poorly with the target lesion percent cross-sectional narrowing (r = 0.166, p < 0.0001). Reference segments contained less calcific and dense fibrotic plaque and proportionately more soft plaque elements. Independent predictors of reference segment percent cross-sectional narrowing were male gender, patient age, diabetes mellitus, hypercholesterolemia and presence of multivessel disease. Independent predictors of reference segment calcification were patient age and serum creatinine levels. Reference segment percent cross-sectional narrowing in 723 patients undergoing transcatheter therapy was similar to that in patients studied for diagnostic purposes; however, reference segment arc of calcium was greater in treated patients (43 +/- 81 vs. 25 +/- 57, p = 0.015). Reference segment disease was not an independent predictor of subsequent angiographic restenosis or clinical events within 12 months of follow-up. CONCLUSIONS: Atherosclerosis is ubiquitous in angiographically normal coronary artery reference segments. Reference segment disease parallels the severity of target lesion disease and is associated with many of the conventional risk factors for coronary artery disease. Because of its sensitivity in detecting atherosclerosis in angiographically normal reference segments, intravascular ultrasound should enhance the study of risk factors for atherosclerosis and the results of therapies to control disease progression.

Age Factors↗

Rapid arterial hemostasis and decreased access site complications after cardiac catheterization and angioplasty: results of a randomized trial of a novel hemostatic device.

OBJECTIVES: This study was performed to test the safety and efficacy of a novel bioabsorbable hemostatic puncture closure device deployed through an arterial sheath. BACKGROUND: Cardiac catheterization procedures are associated with a risk of complications at the arterial access site. Increasing numbers of interventional procedures requiring large sheaths or intense anticoagulation underline the need for secure, rapid methods of obtaining hemostasis at the time of sheath removal. METHODS: We conducted a randomized, multicenter trial in 435 patients undergoing cardiac catheterization or angioplasty at eight participating centers. In 218 patients, hemostasis was achieved using the device (group I); 217 patients were assigned to the manual pressure control group (group II). RESULTS: There were no significant differences in baseline characteristics. Time to hemostasis was considerably shorter in group I (2.5 +/- 15.2 vs. 15.3 +/- 11.7 min [mean +/- SD], p < 0.0001). The deployment success rate for the device was 96%, and 76% of group I patients experienced immediate (within 1 min) hemostasis. Complication rates were lower in group I for bleeding, hematoma and occurrence of any complication. There was no difference in the small incidence of pseudoaneurysm formation. There was no change in either group in the ankle/brachial systolic blood pressure index. Ultrasound follow-up studies 60 days after device deployment revealed complete absorption of the device in all cases. Subgroup analysis revealed particular benefit in patients undergoing interventional procedures. The administration of heparin was associated with a significantly higher complication rate in the manual pressure control group, whereas heparin had no effect on hemostasis time or complication rates in the device group. CONCLUSIONS: This sheath-deployed, bioabsorbable device provides a safe and effective means of obtaining rapid arterial hemostasis after cardiac catheterization procedures. It appears to be particularly useful in those patients most at risk for access site complications.

Aneurysm, False↗

High speed rotational atherectomy: outcome in calcified and noncalcified coronary artery lesions.

OBJECTIVES: This study sought to determine the success and complication rates of high speed rotational coronary atherectomy in calcified and noncalcified lesions. BACKGROUND: Percutaneous transluminal coronary angioplasty and directional coronary atherectomy of calcified lesions are associated with reduced procedural success and increased complications. Rotational atherectomy using the Rotablator catheter abrades noncompliant plaque and may improve outcome in calcified lesions. METHODS: Data from the completed Multicenter Rotablator Registry of 2,161 rotational atherectomy procedures in single lesions were analyzed to determine the relative efficacy of rotational atherectomy for 1,078 calcified and 1,083 noncalcified lesions. The power of the study was 0.86 to detect a significant difference in outcome, if the true success rates in the noncalcified and calcified lesions were 96% and 93%, respectively. RESULTS: Patients with calcified lesions were older (mean [+/- SD] age 66.2 +/- 10.3 vs. 60.5 +/- 11.0 years, p = 0.0001) than those with noncalcified lesions. Calcified lesions were more frequently new (75% vs. 64%, p = 0.0001), angulated (27% vs. 22%, p = 0.02), eccentric (75% vs. 64%, p = 0.0001) and long (32% vs. 27%, > 10 mm in length, p = 0.01). They were also more often complex (57% vs. 46%, p = 0.001) and located in the left anterior descending coronary artery (51% vs. 44%, p = 0.001). Adjunctive coronary angioplasty was used in 82.9% of calcified and 66.9% of noncalcified lesions. Procedural success, defined as < 50% residual stenosis without major complications, was achieved in 94.3% of calcified and 95.2% of noncalcified lesions (p = 0.32). Major complication rates were 4.1% in calcified and 3.1% in noncalcified lesions (p = 0.24). Non-Q wave myocardial infarction was documented in 10.0% of calcified and 7.7% of noncalcified lesions (p = 0.054). Mean postprocedural residual stenosis was 21.6 +/- 13.9% in calcified and 23.3 +/- 15% in noncalcified lesions (p = 0.39). CONCLUSIONS: In this review of data from a large multicenter registry, the success rate of rotational atherectomy was not reduced by calcification despite the more frequent complex nature of the calcified lesions. The Rotablator catheter is likely to be the device of choice for percutaneous intervention in calcified lesions, but definitive conclusions await the results of randomized trials.

Aged↗

Small stent size and intimal hyperplasia contribute to restenosis: a volumetric intravascular ultrasound analysis.

OBJECTIVES: The purpose of this study was to use volumetric intravascular ultrasound analysis of Palmaz-Schatz stents to assess the in-stent restenotic process. BACKGROUND: By reducing lesion elastic recoil and chronic arterial remodeling, stents improve the long-term results of coronary angioplasty. However, stents are prone to the development of neointimal hyperplasia. Angiographic studies of stent restenosis have suggested that these hyperplastic responses are the cause of in-stent restenosis; however, it is difficult to visualize the radiolucent Palmaz-Schatz stent by angiography. Intravascular ultrasound provides detailed cross-sectional imaging of the coronary arteries, especially the intense metallic reflection of endovascular stents. METHODS: Forty-four patients with 60 Palmaz-Schatz stents underwent intravascular ultrasound imaging at follow-up ([mean +/- SD] 8.8 +/- 7.2 months after implantation). Thirty-four stents were placed in saphenous vein grafts and 26 in native coronary arteries; 30 were placed in restenotic lesions. Intravascular ultrasound with automatic transducer pullback at 0.5 mm/s allowed measurement of stent, lumen and intimal hyperplasia cross-sectional areas at 1-mm axial increments within the stents. Using Simpson's rule, stent, lumen and intimal hyperplasia volumes were calculated. Patterns of in-stent restenosis were then identified. RESULTS: Restenotic stents had smaller stent volumes (120 +/- 41 vs. 147 +/- 43 mm3, p = 0.016) and lumen volumes (62 +/- 28 vs. 118 +/- 42 mm3, p < 0.0001) but larger intimal hyperplasia volumes (58 +/- 36 vs. 29 +/- 18 mm3, p < 0.001) than nonrestenotic stents. A focal restenosis pattern was more common (20 [77%] of 26) than a diffuse restenosis pattern (6 [23%] of 26). Stents with focal restenosis and stents with diffuse restenosis had equally small stent volumes (120 +/- 44 vs. 120 +/- 31 mm3, respectively, p = NS); however, stents with diffuse restenosis had larger intimal hyperplasia volumes (84 +/- 30 vs. 50 +/- 34 mm3, p < 0.05). Focal restenosis was most commonly located at the central articulation (45%); the location of focal restenosis was related to the focal accumulation of neointimal tissue. CONCLUSIONS: Stent volume and magnitude and distribution of intimal hyperplasia are important in the development of in-stent restenosis. Stent volume was smaller and intimal hyperplasia volume greater in restenotic stents. Stent restenosis is more commonly focal in nature and located at the central articulation.

Aged↗

Intracoronary stents.

A number of significant milestones were achieved in the field of coronary stent technology in 1994. Two large, randomized multicenter studies demonstrated that stenting has a superior "antirestenosis" effect compared with balloon angioplasty. The application of intravascular ultrasound-guided high-pressure adjunct balloon dilatation for optimal stent expansion and the use of more potent antiplatelet agents improved bleeding complications, shortened hospital stays, and lowered the incidence of stent thrombosis despite reduced anticoagulation following stent placement. Ongoing development of new technologies, including drug-coated and radioactive stents that provide both mechanical support and inhibition of myointimal proliferation, will likely further reduce restenosis frequency. These promising developments will ensure an exciting future for coronary stents as a vital interventional cardiology modality.

Angioplasty, Balloon, Coronary↗

Evidence for apoptosis in human atherogenesis and in a rat vascular injury model.

Apoptosis is a physiological cell death process important for normal development and involved in many pathological conditions. In atherosclerosis, pathological accumulation of cells in the intima has been attributed to the migration and proliferation of smooth muscle cells, macrophages, and lymphocytes. In this report, we explored the possibility that apoptosis may also contribute to the pathogenesis of this disease. We examined 35 human atherosclerotic lesion samples and identified a substantial number of cells undergoing apoptosis in 25 of the samples. Furthermore, in a rat vascular injury model, apoptotic cells were specifically identified in the neointima. The presence of apoptotic cells was demonstrated by terminal deoxynucleotidyl transferase-mediated dUTP-biotin nick end labeling, nuclear staining with propidium iodide, and electron microscopy. Immunostaining with cell-type-specific markers and subsequent terminal deoxynucleotidyl transferase-mediated dUTP-biotin nick end labeling analysis on the same sample revealed that the majority of the apoptotic cells were modulated smooth muscle cells as well as macrophages. These results indicate that apoptosis occurs in cells of the injured blood vessel as well as the advanced atherosclerotic lesion and that physiological cell death may have an important role in determining the course of atherogenesis.

Adult↗

Interaction of human cytomegalovirus with p53: possible role in coronary restenosis.

Restenosis occurs in 25-50% of patients. Within 1-6 months after coronary angioplasty, excessive injury-induced smooth muscle cell (SMC) proliferation contributes to the development of restenosis; its causes remain unknown. The results of this study implicate human cytomegalovirus (HCMV) and HCMV-induced abnormalities in p53 function in the restenosis process. Almost 40% of restenosis lesions, obtained by atherectomy, demonstrated increased SMC p53 levels by p53 immunopositivity; sequencing revealed the p53 to be the wild type. A strong correlation was found between p53 immunopositivity and the presence of HCMV DNA. Moreover, the HCMV IE84 protein co-immunoprecipitates with p53, and p53 transcriptional capacity is reduced by IE84. Thus, HCMV may play a causal role in restenosis, which may be at least partly mediated by inhibiting p53 suppressor effects.

Adult↗

Long-term angiographic and clinical outcome after implantation of balloon-expandable stents in aortocoronary saphenous vein grafts.

Balloon angioplasty of aortocoronary saphenous vein graft lesions is associated with high restenosis and clinical event rates. The goal of this multicenter study was to assess long-term angiographic and clinical outcome of patients electively treated with single Palmaz-Schatz stents in aortocoronary saphenous vein grafts. In 198 patients (209 lesions), elective placement of single Palmaz-Schatz stents was attempted. Angiography was performed at baseline, immediately after stent placement, and at 6-month follow-up. Stent placement was successful in 98.5% of patients. One patient (0.5%) had stent thrombosis. Restenosis occurred in 34% (45 of 133) of the restudied lesions. Restenosis was lower in de novo lesions than in restenotic lesions (22% vs 51%, p < 0.001). Ostial lesions had a higher restenosis rate than nonostial lesions (61% vs 28%, p = 0.003). Freedom from death, myocardial infarction, coronary artery bypass surgery, and repeat angioplasty was present in 70% of patients. Eighty-two percent of patients with de novo lesions remained event-free at 1 year, whereas only 55% of patients with prior angioplasty were event-free at 1 year (p < 0.001). The use of the Palmaz-Schatz stent for the treatment of focal, de novo, aortocoronary saphenous vein graft lesions is associated with a high procedural success rate, a low angiographic restenosis rate, and low clinical event rates, including the need for repeat revascularization. The results of this study need validation by a prospective randomized trial comparing stent implantation with angioplasty.

Aged↗