The effects of lossy compression on the detection of subtle pulmonary nodules.

We examined the ability of radiologists to detect pulmonary nodules in computed radiographic (CR) chest images subjected to lossy image compression. Low-contrast 1-cm diameter targets simulating noncalcified pulmonary nodules were introduced into clinical images and presented to ten radiologists in a series of two-alternative forced-choice (2AFC) observer experiments. The percentages of correct observer responses obtained while viewing noncompressed images (1:1) were compared with those obtained for the same images compressed 7:1, 16:1, 44:1, and 127:1. The images were compressed using a standard full-frame discrete cosine transform (DCT) technique. The degree of compression was determined by quantizing Fourier components in various frequency channels and then Huffman encoding the result. The data show a measurable decline in performance for each compression ratio. Through signal-to-noise ratio (SNR) analysis, we found that the reduction in performance was due primarily to the compression algorithm that increased image noise in the frequency channels of the signals to be detected.

Algorithms

Efficacy of oral ketamine for providing sedation and analgesia to children requiring laceration repair.

A prospective, double-blind, placebo-controlled, randomized clinical trial was conducted to study the efficacy of oral ketamine for providing sedation and analgesia to children during laceration repair. Thirty children between the ages of one and seven years with lacerations that required suturing were randomly assigned to receive either oral ketamine (10 mg/kg) or an identically flavored placebo syrup prior to suturing. Patients were assessed by means of a tolerance score reflecting behavioral correlates of perceived pain at the time of both lidocaine injection and suturing. In addition, a sedation score for monitoring patient level of consciousness was used. The ketamine-treated group demonstrated a significantly greater tolerance to both lidocaine injection (P < 0.001) and suturing (P = 0.009) in comparison to the placebo-treated group. The ketamine-treated group also achieved a significantly greater degree of sedation (P = 0.012). No significant respiratory or circulatory adverse effects were seen in either group, although 26% of patients who received ketamine experienced minor, transient adverse effects. We conclude that oral ketamine in a dose of 10 mg/kg provides effective sedation and analgesia to young children undergoing wound repair.

Administration, Oral

Contrast-detail analysis of image degradation due to lossy compression.

A contrast-detail (CD) experiment was performed to study the effect of lossy compression on computed radiographic (CR) images. Digital CR images of a phantom were compressed by quantizing the full-frame discrete cosine transform and Huffman encoding the result. Since low-contrast detectability is directly linked to an important radiological task, namely, the detection of noncalcified pulmonary nodules in adult chest radiographs, the goal of the study was to quantify any loss in low-contrast detectability due to compression. Compression ratios varied significantly among compressed images, despite the use of fixed compression parameters; detectability could be specified by a single parameter of a CD curve; there was no significant reduction in detectability for an average compression ratio of 11:1; and, there was a statistically significant degradation in detectability for an average compression ratio of 125:1.

Humans

Comparison of the low-contrast detectability of a screen-film system and third generation computed radiography.

Contrast-detail (CD) analysis was used to compare the low-contrast detectability of computed radiography (CR) and screen-film (SF) as applied to the task of adult chest radiography. A phantom was constructed and imaged using the same exposure factors throughout all experiments. Within-observer variance, between-observer variance, and image sample variance were calculated and used to estimate the standard error for each experiment. The results of these CD experiments agreed with the predictions of the Rose model. Observers performed equally well for low-contrast target detection using CR and SF.

Adult

Image data compression using a new floating-point digital signal processor.

A new dual-ported, floating-point, digital signal processor has been evaluated for compressing 512 and 1,024 digital radiographic images using a full-frame, two-dimensional, discrete cosine transform (2D-DCT). The floating point digital signal processor operates at 49.5 million floating point instructions per second (MFLOPS). The level of compression can be changed by varying four parameters in the lossy compression algorithm. Throughput times were measured for both 2D-DCT compression and decompression. For a 1,024 x 1,024 x 10-bit image with a compression ratio of 316:1, the throughput was 75.73 seconds (compression plus decompression throughput). For a digital fluorography 1,024 x 1,024 x 8-bit image and a compression ratio of 26:1, the total throughput time was 63.23 seconds. For a computed tomography image of 512 x 512 x 12 bits and a compression ratio of 10:1 the throughput time was 19.65 seconds.

Algorithms

Medication delivery in the short-bowel syndrome.

Technologic advances such as total parenteral nutrition have prolonged the lives of individuals with short-bowel syndrome who previously would not have survived. However, the day-to-day management of these patients presents a significant challenge to those who take care of them. Providing medications on either an acute or chronic basis without the use of their central catheters is a difficult clinical problem. This article reviews the approach and methods of treating short-bowel patients on the basis of their individual circumstances and physiology.

Absorption