Search PubMed⌕ Search

Biomedical subjects

M A Marsh

Publications and source records attributed to M A Marsh.

At least 19 recordsLinked to original sources

Measurement of B(D+-->K(*0)l(+)nu(l)).

Using 13.53 fb(-1) of CLEO data, we have measured the ratios of the branching fractions R(+)(e),R(+)(mu) and the combined branching fraction ratio R(+)(l), defined by R(+)(l)=[B(D+-->K(*0)l(+)nu(l))]/[B(D+-->K-pi(+)pi(+))]. We find R(+)(e)=0.74+/-0.04+/-0.05, R(+)(mu)=0.72+/-0.10+/-0.05, and R(+)(l)=0.74+/-0.04+/-0.05, where the first and second errors are statistical and systematic, respectively. The known branching fraction B(D+-->K-pi(+)pi(+)) leads to B(D+-->K(*0)e(+)nu(e))=(6.7+/-0.4+/-0.5+/-0.4)%, B(D+-->K(*0)mu(+)nu(mu))=(6.5+/-0.9+/-0.5+/-0.4)%, and B(D+-->K(*0)l(+)nu(l))=(6.7+/-0.4+/-0.5+/-0.4)%, where the third error is due to the uncertainty in B(D+-->K-pi(+)pi(+)).

Journal Article↗

Improved measurement of /V(cb)/ using B-->D*l nu decays.

We determine the weak coupling /V(cb)/ between the b and c quarks using a sample of 3 x 10(6) BB; events in the CLEO detector at the Cornell Electron Storage Ring. We determine the yield of reconstructed B-->D*l nu; decays as a function of w, the boost of the D* in the B rest frame, and from this we obtain the differential decay rate d Gamma/dw. By extrapolating d Gamma/dw to w=1, the kinematic end point at which the D* is at rest relative to the B, we extract the product /V(cb)/F(1), where F(1) is the form factor at w=1. Combined with theoretical results for F(1) we determine /V(cb)/=0.0469+/-0.0014(stat)+/-0.0020(syst)+/-0.0018(theor).

Journal Article↗

Improved measurement of Vub with inclusive semileptonic B decays.

We report a new measurement of the Cabibbo-Kobayashi-Maskawa parameter Vub made with a sample of 9.7 x 10(6) BB- events collected with the CLEO II detector. Using heavy quark theory, we combine the observed yield of leptons from semileptonic B decay in the end-point momentum interval 2.2-2.6 GeV/c with recent CLEO II data on B-->X(s)gamma to find Vub = (4.08+/-0.34+/-0.44+/-0.16+/-0.24)x10(-3), where the first two uncertainties are experimental and the last two are from theory.

Journal Article↗

Search for CP violation in tau--> K(pi)nu(tau) decays.

We search and find no evidence for CP violation in tau decays into the K(pi)nu(tau) final state. We provide limits on the imaginary part of the coupling constant Lambda describing a relative contribution of the CP violating processes with respect to the standard model to be -0.172<Im(Lambda)<0.067 at 90% C.L.

Journal Article↗

Observation of exclusive B --> D(*)K(*-) decays.

We report the first observation of the exclusive decays B-->D((*))K(*-), using 9.66 x 10(6) BB pairs collected at the Upsilon(4S) with the CLEO detector. We measure the following branching fractions: B(B--->D(0)K(*-)) = (6.1+/-1.6+/-1.7)x10(-4), B(B(0)-->D(+)K(*-)) = (3.7+/-1.5+/-1.0)x10(-4), B(B(0)-->D(*+)K(*-)) = (3.8+/-1.3+/-0.8)x10(-4), and B(B--->D(*0)K(*-)) = (7.7+/-2.2+/-2.6)x10(-4). The B-->D(*)K(*-) branching ratios are the averages of those corresponding to the 00 and 11 helicity states. The errors shown are statistical and systematic, respectively.

Journal Article↗

Observation of B(0) --> D0pi(0) and B(0) -->D(*0)pi(0).

We have studied the color-suppressed hadronic decays of neutral B mesons into the final states D*0pi(0). Using 9.67 x 10(6) BB pairs collected with the CLEO detector, we observe the decays B( 0) --> D0pi(0) and B( 0) -->D(*0)pi(0) with the branching fractions BB( 0) -->D0pi(0)) = (2.74(+0.36)(-0.32) +/- 0.55)x10(-4) and BB( 0) -->D(*0)pi(0)) = (2.20(+0.59)(-0.52) +/- 0.79)x10(-4). The first error is statistical and the second systematic. The statistical significance of the D0pi(0) signal is 12.1sigma ( 5.9sigma for D(*0)pi(0)). Utilizing the B( 0) -->D*0)pi(0) branching fractions we determine the strong phases delta(I,D(*)) between isospin 1/2 and 3/2 amplitudes in the Dpi and D*pi final states to be cosdelta(I,D) = 0.89 +/-0.08 and cosdelta(I,D*) = 0.89 +/- 0.08, respectively.

Journal Article↗

Search for charmless B --> VV decays.

We have studied two-body charmless decays of the B meson into the final states rho(0)rho(0), K(*0)rho(0), K(*0)K(*0), K(*0)K(*0), K(*+)rho(0), K(*+)K(*0), and K(*+)K(*-) using only decay modes with charged daughter particles. Using 9.7x10(6) BB pairs collected with the CLEO detector, we place 90% confidence level upper limits on the branching fractions (1.4-14.1)x10(-5), depending on final state and polarization.

Journal Article↗

Rate measurement of D(0)-->K+pi(-)pi(0) and constraints on D(0) -- D(0) mixing.

We present an observation and time-integrated rate measurement of the decay D(0)-->K(+)pi(-)pi(0) produced in 9 fb(-1) of e(+)e(-) collisions near the Upsilon(4S) resonance. The signal is inconsistent with an upward fluctuation of the background by 4.9 standard deviations. We measured the time-integrated rate of D(0)-->K(+)pi(-)pi(0) normalized to the rate of D(0)-->K(+)pi(-)pi(0) to be 0.0043(+0.0011)(-0.0010) (stat)+/-0.0007 (syst). This decay can be produced by doubly Cabibbo-suppressed decays or by the D(0) evolving into a D(0) through mixing, followed by a Cabibbo-favored decay to K(+)pi(-)pi(0). We also found the CP asymmetry A = (9(+25)(-22))% be consistent with zero.

Journal Article↗

Experimental investigation of the two-photon widths of the chi(c0) and the chi(c2) mesons.

Using 12.7 fb(-1) of data collected with the CLEO detector at CESR, we observed two-photon production of the cc states chi(c0) and chi(c2) in their decay to pi(+)pi(-)pi(+)pi(-). We measured gamma(gammagamma)(chi(c))xB(chi(c)-->pi(+)pi(-)pi(+)pi(-)) to be 75+/-13(stat)+/-8(syst) eV for the chi(c0) and 6.4+/-1.8(stat)+/-0.8(syst) eV for the chi(c2), implying gamma(gammagamma)(chi(c0)) = 3.76+/-0.65(stat)+/-0.41(syst)+/-1.69(br) keV and gamma(gammagamma)(chi(c2)) = 0.53+/-0.15(stat)+/-0.06(syst)+/-0.22(br) keV. Also, cancellation of dominant experimental and theoretical uncertainties permits a precise comparison of gamma(gammagamma)(chi(c0))/gamma(gammagamma)(chi(c2)), evaluated to be 7.4+/-2.4(stat)+/-0.5(syst)+/-0.9(br), with QCD-based predictions.

Journal Article↗

Bounds on the CP asymmetry in like-sign dileptons from B(0)B*(0) meson decays.

We have measured the charge asymmetry in like-sign dilepton yields from B(0)B*(0) meson decays using the CLEO detector at the Cornell Electron Storage Ring. We find a(0)(ll) identical with[N(l(+)l(+))-N(l(-)l(-))]/[N(l(+)l(+))+N(l(-)l(-))] = +0.013+/-0.050+/-0.005. We combine this result with a previous, independent measurement and obtain Re(epsilon(B))/(1+ the absolute value of epsilon(B)(2)) = +0.0035+/-0.0103+/-0.0015 (uncertainties are statistical and systematic, respectively) for the CP impurity parameter, epsilon(B).

Journal Article↗

Evidence of New States Decaying into Xi(*)(c)pi.

Using 13.7 fb(-1) of data recorded by the CLEO detector at Cornell Electron Storage Ring, we report evidence of two new charmed baryons: one decaying into Xi(0')(c)pi(+) with the subsequent decay Xi(0')(c)-->Xi(0)(c)gamma, and its isospin partner decaying into Xi(+')(c)pi(-) followed by Xi(+')(c)-->Xi(+)(c)gamma. We measure the following mass differences for the two states: M(Xi(0)(c)gammapi(+))-M(Xi(0)(c)) = 318.2+/-1.3+/-2.9 MeV and M(Xi(+)(c)gammapi(-))-M(Xi(+)(c)) = 324.0+/-1.3+/-3.0 MeV. We interpret these new states as the J(P) = 1 / 2(-) Xi(c1) particles, the charmed-strange analogs of the Lambda(+)(c1)(2593).

Journal Article↗

Observation of B --> phiK and B --> phiK*.

We have studied two-body charmless hadronic decays of B mesons into the final states straight phiK and phiK(*). Using 9.7 million B&Bmacr; pairs collected with the CLEO II detector, we observe the decays B- --> phiK- and B0--> phiK(*0) with the following branching fractions: B(B--->phiK-) = (5.5(+2.1)(-1.8)+/-0.6)x10(-6) and B(B0--> phiK(*0)) = (11.5(+4.5+1.8)(-3.7-1.7))x10(-6). We also see evidence for the decays B0-->phiK0 and B---> phiK(*-). However, since the statistical significance is not overwhelming for these modes, we determine upper limits of <12.3x10(-6) and <22.5x10(-6) ( 90% confidence level), respectively.

Journal Article↗

Search for B --> tau(nu) and B --> K(nu)nu.

We report results of a search for B-->tau(nu) in a sample of 9.7 x 10(6) charged B meson decays. We exclusively reconstruct the companion B decay to suppress background. We set an upper limit on the branching fraction B(B-->tau(nu))<8.4 x 10(-4) at 90% confidence level. We also establish B(B+/--->K+/-nu(nu))<2.4 x 10(-4) at 90% confidence level.

Journal Article↗

Measurement of the relative branching fraction of upsilon(4S) to charged and neutral B-meson pairs.

We analyze 9.7x10(6) B_B pairs recorded with the CLEO detector to determine the production ratio of charged to neutral B-meson pairs produced at the Upsilon(4S) resonance. We measure the rates for B0-->J/psiK((*)0) and B+-->J/psiK((*)+) decays and use the world-average B-meson lifetime ratio to extract the relative widths f(+-) / f(00) = gamma(Upsilon(4S)-->B+B-) / gamma(Upsilon(4S)-->B0 B-0)) = 1.04+/-0.07(stat)+/-0.04(syst). With the assumption that f(+-)+f(00) = 1, we obtain f(00) = 0.49+/-0.02(stat)+/-0.01(syst) and f(+-) = 0.51+/-0.02(stat)+/-0.01(syst). This production ratio and its uncertainty apply to all exclusive B-meson branching fractions measured at the Upsilon(4S) resonance.

Journal Article↗

Measurement of the lambda(+)(c) lifetime.

The Lambda+c lifetime is measured using 9.0 fb(-1) of e+e- annihilation data collected on or just below the Upsilon(4S) resonance with the CLEO II.V detector at CESR. Using an unbinned maximum likelihood fit, the Lambda+c lifetime is measured to be 179.6+/-6.9(stat)+/-4.4(syst) fs. The precision of this colliding beam measurement is comparable to other measurements, which are based on fixed-target experiments, with different systematic uncertainties.

Journal Article↗

Measurements of the mass, total width, and two-photon partial width of the eta(c) meson.

Using 13.4 fb(-1) of data collected with the CLEO detector at the Cornell Electron Storage Ring, we have observed 300 events for the two-photon production of ground-state pseudoscalar charmonium in the decay eta(c)-->K(0)(S)K-/+pi(+/-). We have measured the eta(c) mass to be [2980.4+/-2.3 (stat)+/-0.6 (syst)] MeV and its full width as [27.0+/-5.8 (stat)+/-1.4 (syst)] MeV. We have determined the two-photon partial width of the eta(c) meson to be [7.6+/-0.8 (stat)+/-0.4 (syst)+/-2.3 (br)] keV, with the last uncertainty associated with the decay branching fraction.

Journal Article↗

Progressive hearing loss after transverse temporal bone fracture.

Transverse fractures often violate the otic capsule and commonly, although not invariably, result in immediate and profound sensorineural hearing loss. The pathogenic mechanisms producing sensorineural hearing loss include direct trauma to the cochlear nerve, disruption of the membranous labyrinth, vascular compromise or hemorrhage into the inner ear, perilymphatic fistula, and endolymphatic hydrops. The last two mechanisms account for the occasional patient who develops progressive sensorineural hearing loss after the initial insult. On early posttraumatic evaluation three patients were discovered to have transverse fractures and residual auditory function. Deterioration of hearing led to middle-ear exploration with closure of perilymphatic fistulas. Hearing was preserved in two patients. Diagnosis of posttraumatic perilymphatic fistulas requires early audiometric assessment, high-resolution computed tomographic scanning of the temporal bones to detect fracture of the otic capsule and pneumolabyrinth, and a high index of clinical suspicion.

Accidental Falls↗

Radiologic evaluation of multichannel intracochlear implant insertion depth.

Postoperative plain film x-rays are necessary in all multichannel cochlear implant patients to confirm intracochlear position, detect possible electrode kinking, and provide a reference if postoperative slippage occurs. In addition, precise documentation of multichannel intracochlear electrode insertion depths is necessary for comparison of speech recognition results among patients and may be of use for future speech processing strategies. In the present study, a method has been devised, using a modified Stenver's view, to more accurately document insertion depths of the electrode array and location of individual electrodes on 50 multichannel cochlear implant patients. Surgical estimates of insertion depth are shown to have great variability in regard to distance along the basilar membrane when compared with x-ray documentation. Additionally, there is preliminary evidence that insertion depth, as determined by x-ray studies, has a strong correlation with open-set speech discrimination.

Basilar Membrane↗