Search PubMedSearch

Biomedical subjects

M A Freeman

Publications and source records attributed to M A Freeman.

At least 19 recordsLinked to original sources

T cell responses to synthetic TSH receptor peptides in Graves' disease.

Twenty-eight peptides, representing the entire extracellular domain of the TSH receptor, were synthesised to investigate which parts of this autoantigen may be targets for the T cell response in Graves' disease (GD). T cells from 11 of 21 controls and 26 of 36 newly diagnosed GD patients proliferated in response to one or more peptides with a stimulation index (SI) of greater than 2.0 (chi 2 = 2.31, P greater than 0.1). The response of patients and controls to any of the individual peptides was also not statistically different. However, individual patients gave high SIs with certain peptides to which controls either gave an absent or very weak response. HLA-DR3 was not associated with any particular response to TSHR peptides. Three out of seven GD patients whose T cells were evaluated before and after treatment showed a response of this kind only early in the course of their disease. Intrathyroidal T cells from four GD patients did not give a consistent proliferative response to pools of five peptides, and depleting peripheral blood T cells of their CD8+ population did not affect the proliferative response. These results indicate that the T cell response to the TSH receptor in GD does not seem to be directed against any one particular epitope on the peptides we have tested which cover the extracellular domain.

Amino Acid Sequence

One-stage reimplantation for infected total knee arthroplasty.

One-stage reimplantation for the salvage of infected total knee arthroplasty in 18 patients was reviewed at an average follow-up of five years. There had been one recurrence and one new infection, both in rheumatoid patients with another focus of infection. In four other patients the clinical result was impaired by pain after walking (2) and limited flexion (2). Our results suggest that one-stage reimplantation is a reasonably reliable procedure for the management of a loose infected prosthesis.

Adult

Proximally cemented versus uncemented Freeman-Samuelson knee arthroplasty. A prospective randomised study.

We studied the effect of a layer of cement placed under the tibial component of Freeman-Samuelson total knee prostheses with a metal back and an 80 mm intramedullary stem, using roentgen stereophotogrammetry to measure the migration of the tibial component during one year in 13 uncemented and 16 cemented knees. The addition of cement produced a significant reduction in migration at one year, from a mean of 1.5 mm to one of 0.5 mm (p less than 0.01), including a significant reduction in pure subsidence. One year postoperatively the clinical results were similar between the groups, but, at three years, one uncemented knee had required revision.

Adult

Early migration of prostheses related to long-term survivorship. Comparison of tibial components in knee replacement.

We determined the cumulative survival rates, in arthroplasty of the knee, of three designs of tibial component, using a change of position on standard radiographs or revision for aseptic loosening as criteria of failure. The average migration of each of the three designs in the first postoperative year is known from roentgen stereophotogrammetric analysis reported by other authors. The ranking order of the components as judged by cumulative survival is the same as that determined by early migration. This finding supports the view that the measurement of early migration can predict late aseptic loosening and therefore that such measurements are clinically of value.

Bone Cements

Hydroxyapatite coating of hip prostheses. Effect on migration into the femur.

We studied two groups of femoral hip prostheses: 43 TiAlV ridged press-fit stems, and 26 with similar stems coated with hydroxyapatite on the proximal half. At one year, radiological measurement showed a mean downward migration of 0.99 mm for the TialV prostheses and 0.12 mm for the HA-coated prostheses (p = 0.0002). Hydroxyapatite coating appeared to provide effective bio-active supplementary fixation.

Adult

Accuracy of the Nunn method in measuring acetabular cup migration.

The accuracy of the Nunn method in measuring acetabular component migration was compared with 3 other radiological methods and with roentgen stereophotogrammetry in 34 pelvic radiographs. The Nunn method seems to have the same or better accuracy than the other non-computerized methods, but less accuracy than the computerized EBRA method.

Acetabulum

The scientific basis of cement versus cementless fixation.

The arguments for and against three implant materials (polymethylmethacrylate, cobalt-chrome alloy, and titanium aluminium vanadium alloy) when used as interfaces between a loaded implant and bone are reviewed from mechanical and biologic standpoints. It is concluded that there is neither an overwhelming advantage nor a disadvantage for any one of them.

Alloys

The effect of hydroxyapatite coating on ingrowth of bone into cavities in an implant.

A canine implant study was performed to assess whether hydroxyapatite (HA) could induce bone to close gaps at the bone-prosthesis junction. Titanium alloy (TiAlV) plates with varying grooves cut into them (1, 2, and 3 mm deep) and identical on both sides were sprayed on one side with HA and left as bare metal on the other. These were then implanted into the distal femora of dogs that were killed 4 and 8 weeks afterwards. Specimens were analyzed using optical microscopy and microradiography. Results show that the presence of HA induces bone to grow almost completely down the deepest groove by 8 weeks. In the 1- and 2-mm grooves at 4 weeks the depth of penetration of bone into the grooves was greater on the HA coated side (but the actual volume of bone in the grooves was greater on the TiAlV side because the bone present was more dense). We conclude that the presence of HA induces bone to close relatively large gaps. Although bone does not grow all the way into uncoated defects there can be more bone here in the short term. This feature of HA may be of great value in hip implant fixation.

Animals

Exposure of the hip using a modified anterolateral approach.

This report outlines an exposure to the hip using one curved skin incision, permitting retention of the femoral neck, and allowing access to both the anterior and posterior aspects of the hip, the whole of the proximal femur, and the circumference of the acetabulum. This approach is useful in revision surgery. The anterior abductors are mobilized using partial sharp release. A review of postoperative abductor function is presented, demonstrating satisfactory function after partial sharp release.

Gait

Sensitivity to titanium. A cause of implant failure?

Tissues from five patients who underwent revision operations for failed total hip replacements were found to contain large quantities of particulate titanium. In four cases this metal must have come from titanium alloy screws used to fix the acetabular component; in the fifth case it may also have originated from a titanium alloy femoral head. Monoclonal antibody labelling showed abundant macrophages and T-lymphocytes, in the absence of B-lymphocytes, suggesting sensitisation to titanium. Skin patch testing with dilute solutions of titanium salts gave negative results in all five patients. However, two of them had a positive skin test to a titanium-containing ointment.

Antibodies, Monoclonal

The effect of retention of the femoral neck and of cement upon the stability of a proximal femoral prosthesis.

Radiological measurements of downward femoral component migration are reported for 203 hips in the first 2 years following total hip arthroplasty. The femora differed with respect to the retention of the femoral neck--in 167 it was retained and in 36 it was damaged--and to the use of cement--142 hips were press-fits and 61 were cemented. Multivariate analysis demonstrated that both retention of the neck and the use of cement retarded migration (ie, increased stability) of the femoral component (P = .0003 and .0037, respectively).

Cementation

The effect of a metal-back without a stem upon the fixation of a tibial prosthesis.

Three methods of tibial component fixation without cement (as part of TKA) have been used at the London Hospital. All three methods have used the same polyethylene component fixed with two HDP (Day) pegs. A metal-back without a stem was added to the HDP in group 1. Group 2 consisted of an HDP-only component. In group 3 a stem was added to the metal-back used in group 1. Radiological comparison showed the fixation of the polyethylene component with metal back but no stem to be inadequate; the component tilted into varus more frequently than the other configurations. It is suggested that failure was due to the increased rigidity of the metal-backed component (as compared with the HDP only) and that the rigidity (and the resultant tendency to rock) can be offset by a stem. It is concluded that rigid (ie, metallic) tibial components should have a stem.

Aged

Unconstrained knee arthroplasty after patellectomy.

The authors report seven cases of unconstrained knee arthroplasty with excision of both cruciate ligaments, after previous patellectomy. Six of these seven cases were completely painfree and function was satisfactory in all cases. The reasons for previously reported pain and instability after total unconstrained knee arthroplasty with excision of the cruciate ligaments and a previous patellectomy are discussed.

Aged

ICLH double-cup arthroplasty, 1980-1987.

The results are presented of 92 double-cup arthroplasties modified in light of previously published experience. The review period lasted up to 7 years after operation. Eighty-six had a metal femoral component and six had a ceramic femoral component. Forty metal femoral cups were matched with a cemented acetabulum, while with 46 the acetabular implant was cementless. The overall revision rate for the metal femoral cups was 23.3%, and a further 31.8% demonstrated radiological signs suggestive of loosening. There was no difference between the cemented and uncemented cups in terms of revision rates or clinical results. The clinical results of those hips that have not yet loosened were excellent. A histological study showed that femoral lossening was associated with an erosive cellular response. Surface arthroplasty of the hip with current materials should be abandoned.

Adult