Search PubMed⌕ Search

Biomedical subjects

Lynn Weinert

Publications and source records attributed to Lynn Weinert.

33 records · Page 2Linked to original sources

Ventricular resynchronization by multisite pacing improves myocardial performance in the postoperative single-ventricle patient.

BACKGROUND: Ventricular resynchronization with multisite pacing in heart failure patients results in acute improvement of myocardial performance, but the mechanism is unknown. Our goals were to determine whether multisite pacing results in acute improvement of myocardial performance in postoperative single-ventricle patients, and to elucidate the mechanism by assessing the synchronization of regional ventricular contraction during multisite pacing using real-time three-dimensional echocardiographic imaging. METHODS: Multisite pacing studies were performed in 26 single-ventricle patients (mean age, 28 months; range, 7 days to 11 years) undergoing some form of single-ventricle palliation (stage I Norwood, 4; aortopulmonary shunt, 1; cavopulmonary shunt, 9; Fontan, 8; Fontan revision, 3; valve replacement, 1). Electrocardiogram, blood pressure, mixed-venous oxygen saturation, and three-dimensional echocardiograms (n = 10) were recorded at baseline and during multisite pacing. Data were analyzed to obtain regional volume-time curves for 16 three-dimensional segments of the systemic ventricle. An index of asynchrony was calculated at baseline and during pacing as the standard deviation of all segmental volume-time curves from onset to end of ejection. RESULTS: With multisite pacing performed at a median postoperative day 2 (range, 0 to 9), QRS duration decreased in 24 of 26 patients (93.9 +/- 17.5 versus 71.7 +/- 10.8 ms; p < 0.001); systolic blood pressure increased in 25 of 26 patients (86.3 +/- 20.0 versus 93.8 +/- 20.2 mm Hg; p < 0.001); cardiac index increased in 21 of 22 patients (3.2 +/- 0.8 versus 3.7 +/- 1.0 L x min(-1) x m(-2); p < 0.001); and the index of asynchrony improved in 8 of 10 patients (10.3 +/- 4.8 versus 6.0 +/- 1.4; p < 0.04). CONCLUSIONS: Multisite pacing improves cardiac performance after single-ventricle palliation. Real-time three-dimensional echocardiography demonstrated that multisite pacing improved the synchrony of ventricular contraction.

Cardiac Pacing, Artificial↗

Automated quantitative assessment of wall motion in patients with poor acoustic windows.

BACKGROUND: No technique exists for objective evaluation of left ventricular wall motion in contrast-enhanced images. We tested a new technique for quantification of regional fractional area change using contrast-enhanced power modulation imaging with color kinesis. METHODS: The feasibility of this technique for detecting acute ischemia was first tested in 11 pigs. Next, the accuracy for detecting resting wall-motion abnormalities was determined in 52 patients requiring contrast and compared with conventional interpretation of 2-dimensional images by inexperienced readers. Expert interpretation of 2-dimensional images served as the gold standard. RESULTS: In pigs, coronary occlusion resulted in reversible hypokinesis and reduced regional fractional area change. In patients with poor acoustic windows, this technique's accuracy for quantitative detection of resting wall-motion abnormalities was 86% compared with 81% for conventional interpretation by inexperienced readers (P <.01). CONCLUSIONS: Regional wall motion can be accurately assessed using color-encoded power modulation imaging for patients requiring contrast. This technique may prove a useful diagnostic aid to echocardiographers of varying levels of experience.

Animals↗

Non-invasive assessment of mitral valve area during percutaneous balloon mitral valvuloplasty: role of real-time 3D echocardiography.

BACKGROUND: In the last decade, multiple studies depicted discrepancies between mitral valvular orifice area (MVA) measurements obtained with the pressure half-time (PHT) method and invasive methods during the immediate post-percutaneous mitral valvuloplasty (PMV) period. Our aim was to assess the accuracy of Real-Time 3D echo (RT3D) to measure the MVA in the immediate post-PMV period. The invasively determined MVA was used as the gold standard. METHODS AND RESULTS: We studied 29 patients with rheumatic mitral stenosis from two centres (27 women; mean age 48.2+/-11.3 years), all of which had underwent PMV. MVA was calculated before and after PMV using the PHT method, 2D echo planimetry, RT3D echo planimetry and invasive determination (Gorlin's method). The RT3D MVA assessment showed a better agreement with the invasively derived MVA before and in the immediate post-PMV period (Bland-Altman analysis: Average difference between both methods and limits of agreement: 0.01 (-0.31 to 0.33) cm(2) and -0.12 (-0.71 to 0.47) cm(2)) before and immediately after the PMV, respectively. CONCLUSIONS: RT3D is a feasible and accurate technique for measuring MVA in patients with RMVS. It has the best agreement with the invasively determined MVA, particularly in the immediate post-PMV period.

Adult↗

Dynamic three-dimensional color flow Doppler: an improved technique for the assessment of mitral regurgitation.

BACKGROUND: Prior studies have reconstructed mitral regurgitant flow in three dimensions displaying gray scale renditions of the jets, which were difficult to differentiate from surrounding cardiac structures. Recently, a color-coded display of three-dimensional (3D) regurgitant flow has been developed. However, this display was unable to integrate cardiac anatomy, thereby losing spatial information, which made it difficult to determine the jet origin and its spatial trajectory. To overcome this limitation, an improved method of 3D color reconstruction of regurgitant jets obtained from color flow Doppler using a transesophageal approach was developed to allow the combined display of both color flow and gray scale information. OBJECTIVES: To demonstrate the feasibility of 3D reconstruction of regurgitant mitral flow jets using an improved method of color encoding digital data acquired by transesophageal echocardiography (TEE). METHODS: We studied 46 patients undergoing a clinically indicated TEE study. All subjects had mitral regurgitation detected on a previous transthoracic study. Atrial fibrillation or poor image quality were not used as exclusion criteria. The 3D study was performed using a commercial ultrasound imaging system with a TEE probe (Sonos 5500, Agilent Technologies). A rotational mode of acquisition was used to collect two-dimensional (2D) color flow images at 3-degree intervals over 180 degrees. Images were processed off line using the Echo-View Software (TomTec Imaging Systems). Volume-rendered 3D color flow jets were displayed along with gray scale information of the adjacent cardiac structures. RESULTS: Mitral regurgitant flow, displayed in left atrial and two longitudinal orientations, was successfully reconstructed in all patients. The time for acquisition, post-processing, and rendering ranged between 10 and 15 minutes. There were 28 centrally directed jets and 15 eccentric lesions. Eight patients in the study had periprosthetic mitral regurgitant flow. CONCLUSIONS: Three-dimensional imaging of mitral regurgitant jets is feasible in the majority of patients. This improved technique provides additional information to that obtained from the 2D examination. Particularly, in patients with paravalvular leaks 3D color flow Doppler provides information on the origin and the extent of the dehiscence, as well as insight into the jet direction. In addition, in patients with eccentric mitral regurgitation, this new modality overcomes the inherent limitations of 2D echo Doppler by depicting the full extent of the jet trajectory.

Echocardiography, Doppler, Color↗

Real-time three-dimensional echocardiography using a novel matrix array transducer.

Three-dimensional echocardiography has multiple advantages over two-dimensional echocardiography, such as accurate left ventricular quantification and improved spatial relationships. However, clinical use of three-dimensional echocardiography has been impeded by tedious and time-consuming methods for data acquisition and post-processing. A newly developed matrix array probe, which allows real-time three-dimensional imaging with instantaneous on-line volume-rendered reconstruction, direct manipulation of thresholding, and cut planes on the ultrasound unit may overcome the aforementioned limitations. This report will review current methods of three-dimensional data acquisition, emphasizing the real-time methods and clinical applications of the new matrix array probe.

Echocardiography, Three-Dimensional↗

Accuracy of mitral valve area measurements using transthoracic rapid freehand 3-dimensional scanning: comparison with noninvasive and invasive methods.

OBJECTIVE: The feasibility and accuracy of direct transthoracic 3-dimensional (3D) mitral valve area (MVA) measurements obtained using freehand scanning was investigated in patients with mitral stenosis. METHODS: A total of 30 patients (26 women, 4 men; aged 55 +/- 13 years) underwent a 2-dimensional (2D) and Doppler study 1 hour before percutaneous balloon mitral valvuloplasty. Transthoracic freehand data were acquired using a magnetic receiver attached to a broadband transducer, gated to electrocardiography and respiration. Volumetric MVA measurements from the left ventricle and left atrium were obtained and compared with MVA measurements derived from 2D planimetry, pressure half-time, and proximal isovelocity surface area. Invasive Gorlin MVA measurements were the gold standard for comparison. RESULTS: In all, 29 patients (97%) had 3D data allowing MVA measurements. Direct 3D measurements from the left ventricle had the least bias (0.06 +/- 0.19 cm(2)) and tightest limits of agreement (-0.44 to 0.32) compared with left atrium measurements (0.17 +/- 0.25 cm(2) and -0.67 to 0.33, respectively). The proximal isovelocity surface area method (bias: 0.09 +/- 0.34 cm(2)) was the most accurate of all 2D methods followed by pressure half-time (0.17 +/- 0.36 cm(2)) and planimetry (0.21 +/- 0.29 cm(2)). CONCLUSION: Direct 3D MVA measurements from the left ventricle using transthoracic freehand scanning are more accurate than traditional 2D methods.

Adult↗

Normal values of left ventricular systolic and diastolic function derived from signal-averaged acoustic quantification waveforms: a multicenter study.

Automated border-detection techniques such as acoustic quantification have proven accurate and useful for quantifying left ventricular (LV) function. We acquired LV acoustic quantification waveforms from the parasternal short-axis window in 140 healthy patients in the age range of 16 to 78 years. Signal-averaged waveforms were analyzed for parameters of systolic and diastolic performance. The average fractional area change was 54 +/- 12%, and there were no significant changes in LV systolic function in the age range studied. There were significant changes in diastolic parameters with aging. The percentage of contribution to total LV filling occurring during atrial filling nearly tripled during the 6 decades studied, from 13% in the youngest cohort to 36% in the eighth decade of life. This study provides normal reference values for systolic and diastolic parameters of LV function determined from signal-averaged acoustic quantification waveforms acquired from the parasternal short-axis view in adult and adolescent patients over a wide age range.

Adolescent↗

Objective assessment of left ventricular wall motion from contrast-enhanced power modulation images.

There is no method to objectively evaluate left ventricular (LV) function from contrast-enhanced images. We tested the feasibility of evaluating regional LV function by using power modulation imaging. In protocol 1, 9 anesthetized closed-chest pigs were studied. Images were obtained during contrast infusion at baseline, during LAD occlusion and reperfusion. In protocol 2, images were obtained in 20 patients (14 wall-motion abnormalities; 6 controls) during contrast enhancement. Off-line, frame-by-frame, semiautomated endocardial border detection was followed by color encoding of endocardial motion, followed by segmentation and calculation of regional fractional area changes. In all animals, coronary occlusions resulted in hypokinesis and decreased fractional area changes in LAD-related segments only, which were reversed during reperfusion. In patients, wall-motion analysis was in agreement with an expert reader of dynamic images in 92.5% segments, with interobserver variability of 12.5%. Color encoding of endocardial motion from contrast-enhanced power modulation images allows accurate quantitative assessment of regional LV function.

Aged↗

Quantitative diagnosis of apical cardiomyopathy using contrast echocardiography.

BACKGROUND: The echocardiographic diagnosis of apical hypertrophic cardiomyopathy (ACM) has been limited by the frequent inability to visualize the apical endocardium. We hypothesized that the use of contrast agents in patients with suspected ACM, but nondiagnostic echocardiographic studies, would allow quantitative diagnosis. METHODS: Contrast enhancement was performed in 26 patients with nondiagnostic transthoracic echocardiograms (TTEs) for the diagnosis of ACM; 6 patients with suspected ACM based on unexplained symmetric precordial T-wave inversions and increased apical tracer uptake on single-photon emission computed tomography (SPECT) scans, 10 patients with normal electrocardiogram (ECG) readings and no history of hypertension (healthy group), and 10 patients with hypertension and ECG criteria for left ventricular hypertrophy (LVH group). Images were obtained with Optison (Mallinckrodt Medical; IV, 1.0 mL) using harmonic imaging and low mechanical index. Posterior (PW) and septal wall (SW) thicknesses were measured at end-diastole in the parasternal long-axis view. Apical wall thickness (A) was measured from the contrast-enhanced apical endocardium to the visceral epicardial surface in the apical 4-chamber view. A/PW and A/SW ratios were calculated for each group. Asymmetric apical hypertrophy was defined as an A/PW ratio greater than 1.5. RESULTS: Contrast-enhanced apical thickness was greater than 2.0 cm in all patients in the suspected ACM group but less than 1.2 cm in all patients in the LVH and healthy groups. In all 6 patients in the suspected ACM group, A/PW and A/SW ratios were greater than 1.5. No patient in the healthy or LVH groups had thickness ratios greater than 0.85. CONCLUSION: Contrast echocardiography allows quantitative diagnosis of ACM in patients with suggestive ECG and SPECT but nondiagnostic TTEs. This study suggests that contrast echocardiography should be performed before using more expensive or invasive diagnostic testing for this condition.

Adult↗

Improvement in echocardiographic evaluation of left ventricular wall motion using still-frame parametric imaging.

BACKGROUND: Conventional echocardiographic assessment of left ventricular wall motion is based on visual interpretation of dynamic images, which depends on readers' experience. We tested the feasibility of evaluating endocardial motion using still-frame parametric images. METHODS AND RESULTS: In protocol 1, integrated backscatter images were obtained in 8 anesthetized pigs at baseline, 5, and 60 seconds after left anterior descending coronary occlusion and during reperfusion. Images from 1 cardiac cycle were analyzed offline to create a parametric image of local video intensity oscillations. Ischemia-induced changes were quantified by segmenting the parametric images and calculating regional pixel-intensity profiles. In protocol 2, parametric images were obtained from contrast-enhanced echocardiograms in 30 patients (18 with wall-motion abnormalities; 12 control subjects). "Gold standard" for wall motion was determined from independent interpretations of dynamic images made by 3 experienced reviewers. Dynamic images were independently classified by 3 inexperienced and 3 intermediate-level readers. Interpretation was then repeated in combination with parametric images. Parametric images showed a bright band in the area spanned by endocardial motion, which gradually decreased in brightness and thickness in the left anterior descending territory during coronary occlusion in all animals. In patients, the agreement with the gold standard correlated with the readers' experience (68% inexperienced, 87% intermediate) and significantly improved by adding parametric images (83% and 91%, respectively). CONCLUSION: Parametric imaging provides a still-frame display of regional endocardial motion, sensitive to track ischemia-induced abnormalities. When combined with dynamic images, this technique improves the accuracy of the interpretation of wall motion, especially by less experienced echocardiographers.

Aged↗

Automated calculation of the Tei index from signal averaged left ventricular acoustic quantification wave forms.

The Tei index is a combined measurement of systolic and diastolic left ventricular (LV) performance and may be more useful for the diagnosis of global cardiac dysfunction than either systolic or diastolic measures alone. We sought to determine whether the Tei index could be accurately calculated from LV area waveforms generated with automated border detection. Twenty-four patients were studied in 3 groups: systolic dysfunction, diastolic dysfunction, and normal. The Tei index was calculated both from Doppler tracings and from analysis of LV area waveforms. Excellent agreement was found between Doppler-derived timing intervals and the Tei index with those obtained from averaged LV area waveforms. A significant difference was seen in the Tei index, computed with both Doppler and automated border detection techniques, between the normal group and those with LV systolic dysfunction and subjects with isolated diastolic dysfunction. This study validates the use of LV area waveforms for the automated calculation of the Tei index.

Acoustics↗

Evaluation of Left Ventricular Diastolic Performance Using Automated Border Detection.

Acoustic quantification (AQ) is a noninvasive technique which provides online left ventricular (LV) area/volume waveforms. The filling portion of the AQ waveform can be used to assess LV diastolic properties. Analysis of signal-averaged AQ curves enhances the waveforms and allows reliable, quantitative, and automated analysis. From signal-averaged AQ LV waveforms, the phases of diastole can be easily detected and several parameters of diastolic performance calculated. Analysis of signal-averaged LV waveforms is complementary to that of LV AQ analysis. AQ has been used to identify diastolic dysfunction in patients with LV hypertrophy and systemic hypertension. Normal values of these parameters are age dependent and reference values will soon be available.

Journal Article↗

Evaluation of Global and Regional Right Ventricular Function Using Automated Border Detection Techniques.

Quantitative evaluation of right ventricular (RV) function remains challenging due to the complex geometry of this chamber, which precludes the use of simple geometric assumptions. Automated border detection (ABD) techniques, which provide online changes in cardiac chamber dimensions, have been predominantly used for quantitative assessment of global as well as regional left ventricular function. Recently, acoustic quantification has been validated for quantitative evaluation of global RV function, and color kinesis has been used to objectively assess systolic and diastolic regional RV function. In this article, the main studies validating ABD for the objective assessment of global RV function and the current clinical uses of this technique are reviewed. In addition, technical guidelines and limitations of ABD techniques are described, and potential applications of color kinesis for quantitative assessment of regional systolic and diastolic RV performance are detailed. ABD techniques provide new insights into right atrial and RV systolic and diastolic properties. The clinical value of these techniques in the diagnosis, prognosis, and potential guidance of therapeutic management of RV dysfunction remains to be determined.

Journal Article↗

Color Kinesis: Principles of Operation and Technical Guidelines.

Color kinesis is a new echocardiographic technique that aids in the assessment of global and regional left ventricular performance during either systole or diastole. Color kinesis uses automated border detection technology based on backscatter data to display both the magnitude and timing of endocardial motion in real time. The color kinesis display superimposes a color overlay on the two-dimensional echocardiographic image; the number of color pixels represents the magnitude of endocardial motion, while the different colors represent the timing of endocardial motion according to a predefined color scheme. Because color kinesis is an operator-dependent technique, the steps involved in performing a technically adequate study will be reviewed as well as the pitfalls and technical limitations. The potential clinical applications of color kinesis will also be discussed.

Journal Article↗