Search PubMed⌕ Search

Biomedical subjects

Lutz P Nolte

Publications and source records attributed to Lutz P Nolte.

13 recordsLinked to original sources

Development of a force amplitude- and location-sensing device designed to improve the ligament balancing procedure in TKA.

To improve the ligament balancing procedure during total knee arthroplasty a force-sensing device to intraoperatively measure knee joint forces and moments has been developed. It consists of two sensitive plates, one for each condyle, a tibial base plate and a set of spaces to adapt the device thickness to the patient-specific tibiofemoral gap. Each sensitive plate is equipped with three deformable bridges instrumented with thick-film piezoresistive sensors, which allow accurate measurements of the amplitude and location of the tibiofemoral contact forces. The net varus-valgus moment is then computed to characterize the ligamentous imbalance. The developed device has a measurement range of 0-500 N and an intrinsic accuracy of 0.5% full scale. Experimental trials on a plastic knee joint model and on a cadaver specimen demonstrated the proper function of the device in situ. The results obtained indicated that the novel force-sensing device has an appropriate range of measurement and a strong potential to offer useful quantitative information and effective assistance during the ligament balancing procedure in total knee arthroplasty.

Arthroplasty, Replacement, Knee↗

A novel computational method for real-time preoperative assessment of primary dental implant stability.

A novel methodology which allows for fast and fully automatic structural analysis during preoperative planning for dental implant surgery is presented. This method integrates a fully automatic fast finite element solver within the framework of new concepts in computer-assisted preoperative planning for implant surgery. The planning system including optimized structural planning was validated by experimental results. Nine implants were placed in pig mandibles and mechanically loaded using a testing rig. The resulting displacements were measured and compared with those predicted by numerical analysis during planning. The results show that there were no statistically significant differences (P = 0.65) between the results of the models and the experiments. The results show that fast structural analysis can be integrated with surgical planning software allowing the initial axial implant stability to be predicted in real time during planning. It is believed that such a system could be used to select patients for immediate implant loading and, when further developed, be useful in other areas of preoperative surgical planning.

Animals↗

Computer-assisted LISS plate osteosynthesis of proximal tibia fractures: feasibility study and first clinical results.

Fluoroscopy is the most common tool for the intraoperative control of long-bone fracture reduction. Limitations of this technology include high radiation exposure for the patient and the surgical team, limited visual field, distorted images, and cumbersome verification of image updating. Fluoroscopy-based navigation systems partially address these limitations by allowing fluoroscopic images to be used for real-time surgical localization and instrument tracking. Existing fluoroscopy-based navigation systems are still limited as far as the virtual representation of true surgical reality is concerned. This article, for the first time, presents a reality-enhanced virtual fluoroscopy with radiation-free updates of in situ surgical fluoroscopic images to control metaphyseal fracture reduction. A virtual fluoroscopy is created using the projection properties of the fluoroscope; it allows the display of detailed three-dimensional (3D) geometric models of surgical tools and implants superimposed on the X-ray images. Starting from multiple registered fluoroscopy images, a virtual 3D cylinder model for each principal bone fragment is constructed. This spatial cylinder model not only supplies a 3D image of the fracture, but also allows effective fragment projection recovery from the fluoroscopic images and enables radiation-free updates of in situ surgical fluoroscopic images by non-linear interpolation and warping algorithms. Initial clinical experience was gained during four tibia fracture fixations that were treated by LISS (Less Invasive Stabilization System) osteosynthesis. In the cases operated on, after primary image acquisition, the image intensifier was replaced by the virtual reality system. In all cases, the procedure including fracture reduction and LISS osteosynthesis was performed entirely in virtual reality. A significant disadvantage was the unfamiliar operation of this prototype software and the need for an additional operator for the navigation system.

Adult↗

Characteristics of PMHS Lumbar Motion Segments in Lateral Shear.

The purpose of this study was to determine the characteristics of eighteen lumbar spine motion segments subjected to lateral shear forces under quasi-static (0.5 mm/s) and dynamic (500 mm/s) test conditions. The quasi-static test was also performed on the lumbar spine of a side impact anthropomorphic test device, the EuroSID-2 (ES-2). In the quasi-static tests, the maximum force before disc-endplate separation in the PMHS lumbar motion segments was 1850 +/- 612 N, while the average linear stiffness of PMHS lumbar motion segments was 323 +/- 126 N/mm. There was a statistically significant difference between the quasi-static (1850 +/- 612 N) and dynamic (2616 +/- 1151 N) maximum shear forces. The ES-2 lumbar spine (149 N/mm) was more compliant than the PMHS lumbar segments under the quasi-static test condition.

Journal Article↗

Basic principles of CAOS.

The term computer aided orthopedic surgery (CAOS) stands for approaches that aim to improve visibility to the surgical field and increase application accuracy by means of so-called navigation systems alone or in combination with smart end-effectors when carrying out surgical actions. These goals achieved by linking the bony anatomy being operated on with a virtual representation, such as an image dataset. This article introduces the basic principles of CAOS. Surgical navigation systems that use modern tracking technology are introduced and classified according to the chosen virtual representation of the surgical object, ie, image-free and image-based (preoperative and intraoperative) technology. Within the latter class in particular, CT-and fluoroscopy-based (2-D and 3-D) systems have successfully made their way into the operating room (OR). Challenges during the development of the underlying enabling technologies are presented and references to orthopedic applications in different anatomical areas are given.

Fluoroscopy↗

C-arm based navigation in total hip arthroplasty-background and clinical experience.

After experimental and preclinical evaluation of a CT-free image guided surgical navigation system for acetabular cup placement, the system was introduced into clinical routine. The computation of the angular orientation of the cup is based on reference coordinates from the anterior pelvic plane concept. A hybrid strategy for pelvic landmark acquisition has been introduced, involving percutaneous pointer-based digitization with the noninvasive bi-planar landmark reconstruction using multiple registered fluoroscopy images. From January 2001 to October 2003, a total of 236 consecutive patients (mean age 66 years, 144 male, 92 female, 124 left and 112 right hip joints) were operated on with the hybrid CT-free navigation system. During each operation, the angular orientation of the inserted implant was recorded. To determine the placement accuracy of the acetabular components, the first 50 consecutive patients underwent a CT scan 7-10 days postoperatively to analyze the cup position relative to the anterior pelvic plane. This procedure was done blinded and with commercial planning software. There was no significant learning curve observed for the use of the system. Mean values for postoperative inclination read 42 degrees (SD 3.6, range (37-49)) and anteversion 21 degrees (SD 3.9, range (10-28)). The resulting system accuracy, ie, the difference between intraoperatively calculated cup orientation and postoperatively measured implant position shows a maximum error of 5 degrees for the inclination (mean 1.5 degrees, SD 1.1) and 6 degrees for the anteversion (mean 2.4 degrees, SD 1.3). An accuracy of better than 5 degrees inclination and 6 degrees anteversion was achieved under clinical conditions, which implies that there is no significant difference in performance from the established CT-based navigation methods. Image-guided CT-free cup navigation provides a reliable solution for future total hip arthroplasty (THA).

Aged↗

Simulated influence of osteoporosis and disc degeneration on the load transfer in a lumbar functional spinal unit.

As life expectancy increases, age-related disorders and the search for related medical care will expand. Osteoporosis is the most frequent skeletal disease in this context with the highest fracture risk existing for vertebrae. The aging process is accompanied by systemic changes, with the earliest degeneration occurring in the intervertebral discs. The influence of various degrees of disc degeneration on the load transfer was examined using the finite element method. The effect of different possible alterations of the bone quality due to osteoporosis was simulated by adjusting the corresponding material properties and their distribution and several loadings were applied. An alteration of the load transfer, characterised by changed compression stiffness and strain distributions as well as magnitudes, due to osteoporotic bone and degenerated discs was found. When osteoporosis was simulated, the stiffness was substantially decreased, larger areas of the cancellous bone were subjected to higher strains and strain maxima were increased. Increasing ratios of transverse isotropy in the osteoporotic bone yielded smaller effects than reduced bone properties. Including a degenerated disc mainly altered the strain distribution. Combining osteoporosis and degenerated discs reduced the areas of cancellous bone subjected to substantial strain. Based on these results, it can be concluded that the definition of a healthy disc in osteoporotic spines might be considered as a worst-case scenario. One attempt to evaluate the progress of osteoporosis can be made by introducing increasing degrees of anisotropy. If several parameters in a model are changed to simulate degeneration, it should be pointed out how each individual definition influences the overall result.

Bone Density↗

Fluid flow and convective transport of solutes within the intervertebral disc.

Previous experimental and analytical studies of solute transport in the intervertebral disc have demonstrated that for small molecules diffusive transport alone fulfils the nutritional needs of disc cells. It has been often suggested that fluid flow into and within the disc may enhance the transport of larger molecules. The goal of the study was to predict the influence of load-induced interstitial fluid flow on mass transport in the intervertebral disc. An iterative procedure was used to predict the convective transport of physiologically relevant molecules within the disc. An axisymmetric, poroelastic finite-element structural model of the disc was developed. The diurnal loading was divided into discrete time steps. At each time step, the fluid flow within the disc due to compression or swelling was calculated. A sequentially coupled diffusion/convection model was then employed to calculate solute transport, with a constant concentration of solute being provided at the vascularised endplates and outer annulus. Loading was simulated for a complete diurnal cycle, and the relative convective and diffusive transport was compared for solutes with molecular weights ranging from 400 Da to 40 kDa. Consistent with previous studies, fluid flow did not enhance the transport of low-weight solutes. During swelling, interstitial fluid flow increased the unidirectional penetration of large solutes by approximately 100%. Due to the bi-directional temporal nature of disc loading, however, the net effect of convective transport over a full diurnal cycle was more limited (30% increase). Further study is required to determine the significance of large solutes and the timing of their delivery for disc physiology.

Animals↗

The importance of the endplate for interbody cages in the lumbar spine.

Intervertebral cages in the lumbar spine represent an advancement in spinal fusion to relieve low back pain. Different implant designs require different endplate preparations, but the question of to what extent preservation of the bony endplate might be necessary remains unanswered. In this study the effects of endplate properties and their distribution on stresses in a lumbar functional spinal unit were investigated using finite-element analyses. Three-dimensional finite-element models of L2-L3 with and without a cage were used. An anterior approach for a monobloc, box-shaped cage was modelled. The results showed that inserting a cage increased the maximum von Mises stress and changed the load distribution in the adjacent structures. A harder endplate led to increased concentration of the stress peaks and high stresses were propagated further into the vertebral body, into areas that would usually not experience such stresses. This may cause structural changes and provide an explanation for the damage occurring to the underlying bone, as well as for the subsequent subsidence of the cage. Stress distributions were similar for the two endplate preparation techniques of complete endplate preservation and partial endplate removal from the centre. It can be concluded that cages should be designed such that they rely on the strong peripheral part of the endplate for support and offer a large volume for the graft. Furthermore, the adjacent vertebrae should be assessed to ensure that they show sufficient density in the peripheral regions to tolerate the altered load transfer following cage insertion until an adequate adaptation to the new loading situation is produced by the remodelling process.

Computer Simulation↗

On the development and comparative evaluation of an ultrasound B-mode probe calibration method.

OBJECTIVE: Precise transducer calibration is an essential prerequisite for reliable surface registration based on ultrasound B-mode imaging devices. The clinical usage of a novel B-mode transducer calibration technique was evaluated and its attainable calibration precision assessed. MATERIALS AND METHODS: The Three Wire Method and the Cambridge Calibration Method were used as reference techniques to compare the efficiency, calibration precision and spatial requirements of the different techniques. A total of 20 calibration trials were performed using each technique and were statistically evaluated for accuracy and speed. RESULTS: The mean error characterizing the calibration precision of the Three Wire Method was 3.2 mm, obtained in a phantom with a volume of 14 x 10(6) mm(3) in 18.48 min. The Cambridge method resulted in a mean calibration error of 2.2 mm, but required a larger phantom with a volume of 35 x 10(6) mm3 to be used for a duration of 9.30 min. The proposed method yielded an average calibration error of 1.9 mm and was performed, on average, in 2 min using a phantom with a size smaller than 1 x 10(6) mm3. CONCLUSIONS: The suggested calibration method offers decreased time and space while retaining an equivalent calibration precision when compared to established reference methods.

Calibration↗

Image-based hip navigation.

After experimental and preclinical evaluation (HAP Paul Award 2001) of a CT-free image-guided surgical navigation system for acetabular cup placement, the system was introduced into clinical routine. The computation of the angular orientation of the cup is based on reference coordinates from the anterior pelvic plane (APP) concept. A hybrid strategy for pelvic landmark acquisition has been introduced involving percutaneous pointer-based digitization with the noninvasive biplanar landmark reconstruction using multiple registered fluoroscopy images. From January 2001 to May 2002, 118 consecutive patients (mean age 68 years, 82 male, 36 female, and 62 left and 56 right hip joints) were operated on with the hybrid CT-free navigation system. During each operation, the angular orientation of the inserted implant was recorded. To determine the placement accuracy of the acetabular components, the first 50 consecutive patients underwent a CT scan 7-10 days postoperatively to analyze the cup position relative to the APP. This was done blinded with commercial planning software. There was no significant learning curve observed for the use of the system. Mean values for postoperative inclination read 43 degrees (SD 3.0, range 37-49) and anteversion 19 degrees (SD 3.9, range 10-28). The resulting system accuracy, i.e., the difference between intraoperatively calculated cup orientation and postoperatively measured implant position, shows a maximum error of 5 degrees for the inclination (mean 1.5 degrees, SD 1.1) and 6 degrees for the anteversion (mean 2.4 degrees, SD 1.3). An accuracy of better than 5 degrees inclination and 6 degrees anteversion was achieved under clinical conditions, which implies that there is no significant difference in performance from the established CT-based navigation methods. Image-guided CT-free cup navigation provides a reliable solution for future total hip arthroplasty (THA).

Acetabulum↗

Factors influencing stresses in the lumbar spine after the insertion of intervertebral cages: finite element analysis.

Intervertebral cages in the lumbar spine have been an advancement in spinal fusion to relieve low back pain. Even though initial stability is accepted as a requirement for fusion, there are other factors. The load transfer and its effect on the tissues adjacent to the cage may also play an essential role, which is not easily detectable with experimental tests. In this study the effects of an intervertebral cage insertion on a lumbar functional spinal unit were investigated using finite element analyses. The influences of cage material, cancellous bone density and spinal loading for the stresses in a functional spinal unit were evaluated. Three-dimensional (3D) finite element models of L2-L3 were developed for this purpose. An anterior approach for a monobloc, box-shaped cage was modelled. Models with cage were compared to the corresponding intact ones. The results showed that inserting a cage increased the maximum von Mises stress and changed the load transfer in the adjacent structures. Varying the cage material or the loading conditions had a much smaller influence than varying the cancellous bone density. The denser the cancellous bone, the more the stress was concentrated underneath the cage, while the remaining regions were unloaded. This study showed that the density of the underlying cancellous bone is a more important factor for the biomechanical behaviour of a motion segment stabilized with a cage, and its eventual clinical success, than the cage material or the applied load. Inserting an intervertebral cage markedly changed the load transfer. The altered stress distribution may trigger bone remodelling and explain damage of the underlying vertebrae.

Adult↗

Thoracolumbar spine mechanics contrasted under compression and shear loading.

The mechanical properties of the human spine have been studied extensively in compression, but there remains a lack of fundamental data in shear. The overall goal of this study was to contrast the mechanics of the thoracolumbar functional spinal unit (FSU) under compression and shear-type loads by evaluating endplate deformation, disc pressures, and kinematics between the different loading types. Eleven T12-L1 and one L1-L2 human FSUs were tested. Compression loads consisted of pure compression, extension-compression, flexion-compression, lateral left and right compression applied individually to a maximum of 500 N. Shear loading consisted of posterior, anterior, left, and right shear to a maximum of 500 N. Intervertebral motions, disc pressure, and vertebral body deformations were recorded for all loads. The deformations were measured using strain gauge rosettes at three points on the inferior vertebral body and one on the superior endplate of the inferior vertebra. The disc pressures and endplate deformations measured were significantly less in shear loading compared to compression and did not change significantly with the type of compression load. Vertebral rim strains were generally greater under shear loading compared with compression. The mechanics of load transfer in compression was the production of high disc pressures which were not linearly correlated with the central endplate deformation. In shear, the mechanism appears to be via the annulus fibrosus without the development of significant disc pressure. These differences between compression and shear loading may have implications for injury mechanisms in the thoracolumbar spine.

Adult↗