Search PubMed⌕ Search

Biomedical subjects

Luisa Pasti

Publications and source records attributed to Luisa Pasti.

6 recordsLinked to original sources

Chromatography as Lévy stochastic process.

The Stochastic Theory of Chromatography has been revised in light of some of the most relevant Lévy's findings in Theory of Probability, including the so-called Lévy's distance, the characteristic function and the theory of infinitesimally divisible distributions. These concepts represent the key to exploit and understand, at a molecular basis, phenomena typical of chromatographic separations under linear conditions, such as peak tailing and splitting. In particular, Lévy's distance has been used to quantify the degree of convergence of real peaks towards an ideal Gaussian shape; the characteristic function properties, introduced by Lévy to deal with the problem of the addition of independent random variables, have been employed to solve a wide variety of chromatographic models (including adsorption on heterogeneous surfaces) and to interpret mobile phase dispersion from a probabilistic point of view. Finally, Lévy's studies concerning infinitesimally divisible distributions have allowed to introduce in the stochastic description of chromatography, effects associated to dispersion in mobile phase. It has been demonstrated that, according to Lévy's canonical representation of stochastic processes, the basis of chromatography is a mobile phase Poisson Process. Represented as a Lévy's process, the microscopic-probabilistic model of chromatography permits the establishment of a connection between single-molecule properties and their statistical fluctuations and shapes of real chromatographic peaks allowing, at the same time, for the constitution of a link between different branches of physical sciences.

Chromatography↗

Stochastic theory of size exclusion chromatography: peak shape analysis on single columns.

The stochastic theory of size exclusion chromatography (SEC) was applied to analyze the peak shape of chromatograms obtained with a wide range of polystyrene standards on various columns. The columns were packed with stationary phases of different pore sizes. The stochastic-dispersive model of SEC results in a peak shape model that fits well the symmetrical and asymmetrical peaks observed in SEC. From the peak shape parameters obtained after nonlinear parameter estimation, information can be gained regarding the fundamental characteristics of the size exclusion process. When a series of polymer standards are analyzed on one column-in a manner similar to other methods of inverse chromatography-the stationary phase can be characterized. The dependence of the ingress and the egress processes on the relative size of the macromolecule to the pore size was determined. We found that for small molecules the selectivity in SEC arises from the ingress process, while when the size of the macromolecule is comparable to that of the pore-i.e., close to the exclusion limit-the egress process will also strongly affect the selectivity.

Journal Article↗

Single-molecule observation and chromatography unified by Lévy process representation.

A renewed stochastic model of chromatography is proposed able to establish a conceptual link between the single-molecule dynamics observations in a given chromatographic system and chromatographic experiment results in the same media. The chromatographic peak is expressed through its Fourier transform as a function of the experimental sorption time distribution. The pertinent numerical procedure necessary for obtaining the chromatographic peak is described, and the numerical programming code is given. Two types of cases were considered, the first one where the sole discrete sorption time distribution is available, and the second one where the adsorption mechanism is made of a mixture of continuous and discrete sorption time distributions. The method is applied to experimental data found in the literature by determining typical chromatographic peak shapes on the basis of the experimental interface adsorption data. This renewed stochastic approach is based on the so-called Levy canonical description of stochastic processes and appears to be the most general basis for handling separation processes from a stochastic point of view.

Journal Article↗

Programmed field decay thermal field flow fractionation of polymers: a calibration method.

The universal calibration procedure typical of thermal field flow fractionation (ThFFF) under constant thermal field operation was extended to thermal field programming (TFP) operation. The method requires knowledge of the following: (a) the programming function, which only depends on the thermal field decay function, (b) the physicochemical properties of the solvent, and (c) the calibration plot under varying channel cold wall temperatures (T(c)). Two field flow fractionation field programming conditions, with either a constant or a variable in time carrier flow velocity, are exploited. The method is based on determination, for each retention time position, of the average lambda retention value typical of TFP ThFFF. This parameter is then used to obtain the calibration plot (i.e., the molecular weight of the species as a function of the retention time position) by using the programming function and the calibration plot under varying T(c) values. The procedure approximation errors are also derived as a function of the programming type and solute-solvent system. To properly test the procedure, the calibration plot for the system constituted by polystyrene (PS) in cis-trans Decalin was determined, under varying conditions T(c) and thermal gradients, by using a set of monodisperse PS standards of different molecular weights (M). The procedure was first validated by simulation under two typical cases of TFP ThFFF operation. The approximation errors were found acceptable (in the worse cases, the accuracy in M prediction was 3%) and are in agreement with the theory. The procedure was then experimentally validated under varying programming decay function conditions. The reproducibility and accuracy of the M determination are both better than 2%.

Journal Article↗

Decoding two-dimensional complex multicomponent separations by autocovariance function.

A new method for decoding two-dimensional (2D) multicomponent separations based on the use of the 2D Autocovariance function (2D-ACVF) has been developed. Theoretical models of single component (SC) spot distributions in 2D separations, both random and structured, are developed as the basis for a nonlinear estimation of both sample and separation system parameters from experimental 2D separations. The number of SCs, the average spot size, the spot capacity, and the saturation factor can be evaluated in the case of random SC spot patterns. The procedure was validated by extensive numerical simulation under conditions close to those usually found in GC x GC or 2D-polyacrylamid gel electrophoresis of proteins. The worse precision degree was no greater than 10% in the case of maximum spot density. This imprecision was fully accounted for, and it seems acceptable owing to the intrinsic statistical character of the estimation method. Structured multicomponent 2D separations, where SCs are linked by linear relationships, give rise to specific structured patterns in 2D-ACVF plots from which the parameters (phase and frequency) of the structured SC sequences can be evaluated: the study of 2D-ACVF makes it possible to decode multicomponent 2D separation, that is, to determine the number, relative abundance, and structural similarities of the single components. Pertinent expressions of the theoretical 2D-ACVF were derived for simple cases, and a procedure for decoding cases of structured 2D separations was developed and applied. It was shown that 2D separations containing both random and structured patterns of SC spots give rise to 2D-EACVF, which is the superimposition of the two component parts. This feature allows one, in principle, to decode the two components. The relevance of these results for Giddings sample dimensionality and separation dimensionality and their effective experimental evaluation is discussed.

Journal Article↗

Decoding of complex isothermal chromatograms recovered from space missions. Identification of molecular structure.

A chemometric approach, based on the study of the autocovariance function, is described to study isothermal GC chromatograms of multicomponent mixtures: isothermal GC analysis is the method of choice in space missions since it is, to date, the only method compatible with flight constraints. Isothermal GC chromatograms look inhomogeneous and disordered with peak density decreasing at higher retention times: a time axis transformation is proposed to make retention an homogeneous process so that CH2 addition in terms of an homologous series yields a constant retention increment. The time axis is transformed into a new scale based on the retention times of n-alkanes, as they are the basis of the universal Kovats indices procedure. The order introduced into the chromatogram by retention time linearization can be simply singled out by the experimental autocorrelation function (EACF) plot: if constant inter-distances are repeated in different regions of the chromatogram, well-shaped peaks are evident in the EACF plot. By comparison, with a standard mixture it is possible to identify peaks diagnostic of specific molecular structures: study of the EACF plot provides information on sample chemical composition. The procedure was applied to standard mixtures containing compounds representative of the planetary atmospheres that will be investigated in the near future: in particular, those related to Titan's atmosphere (Cassini-Huygens mission) and cometary's nucleus (Rosetta mission). The employed experimental conditions simulated those applied to GC instruments installed on space probes and landers in space missions. The method was applied to two specific investigations related to space research, i.e., a comparison of retention selectivity of different GC columns and identification of the chemical composition of an unknown mixture.

Chromatography, Gas↗