Scanning electron microscopic and histologic evaluation of the AcrySof SA30AL acrylic intraocular lens. Manufacturing quality and morphology in the capsular bag.

PURPOSE: To evaluate the properties of the AcrySof(R) SA30AL (Alcon Laboratories, Inc.) single-piece foldable posterior chamber intraocular lens (IOL). SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Two nonimplanted clinical-quality AcrySof IOLs were examined by gross, light, and scanning electron microscopy (SEM). In addition, 2 eyes implanted with this IOL obtained post-mortem, the first such eyes accessioned in our laboratory and the first described to date, were examined using the Miyake-Apple posterior photographic technique and by histologic sections. RESULTS: Scanning electron microscopy of the SA30AL IOL showed excellent surface finish. The edge of the optic was square (truncated) and had a matte (velvet or ground-glass) appearance, a feature that may minimize edge glare and other visual phenomena. A well-fabricated square or truncated optic edge was demonstrated. Miyake-Apple analysis revealed that the SA30AL IOL showed appropriate fit and configuration within the capsular bag. Histologic correlation of the IOL's square edge and its relation to the capsular bag and adjacent Soemmering's ring were noted. CONCLUSIONS: The AcrySof SA30AL IOL is a well-fabricated lens that situates well in the capsular bag. The truncated optic and its relationship to adjacent structures show a morphological profile that has been shown to be highly efficacious in reducing the rate of posterior capsule opacification.

Acrylates↗

Diffuse lamellar keratitis: evaluation of etiology, histopathologic findings, and clinical implications in an experimental animal model.

PURPOSE: To induce diffuse lamellar keratitis (DLK) and investigate the potential causative agents in an animal model. SETTING: Magill Research Center for Vision Correction, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: In 70 eyes of 35 Dutch Belted rabbits, a corneal flap was cut and the interface randomly exposed to 1 of 7 substances: Pseudomonas aeruginosa endotoxin, 1 of 2 Staphylococcus aureus exotoxins, meibomian gland secretion, povidone-iodine 10%, Palmolive Ultra soap, and Klenzyme soap. Slitlamp examinations were performed 1, 3, 5, and 7 days postoperatively. The DLK was staged from 1 to 4. On day 7, the rabbits were killed and the eyes enucleated and processed for histopathologic examination. RESULTS: At the end of the study, 54 eyes (46 exposed, 8 control) were available for evaluation. The 8 eyes studied concurrently in the control group remained clear and did not show interface inflammation. Thirty-one of 46 eyes (67%) treated with the various test substances developed DLK. The highest DLK rates were found with the cleaning soap Palmolive Ultra (100%; P =.022) and P. aeruginosa lipopolysaccharide endotoxin (90%; P =.026). CONCLUSIONS: Interface inflammation was consistently induced in the animal model. All 7 agents caused DLK in at least some eyes. The histopathologic evaluation showed the morphologic profile of the marked inflammatory cellular reaction that occurred in almost all the specimens.

Animals↗

Corneal flap complications in refractive surgery: Part 2: postoperative treatments of diffuse lamellar keratitis in an experimental animal model.

PURPOSE: To induce diffuse lamellar keratitis (DLK) and investigate a prophylactic treatment with pharmacological agents. SETTING: Magill Research Center for Vision Correction, Storm Eye Institute, Charleston, South Carolina, USA. METHODS: In 100 eyes of 50 Dutch Belted rabbits, a nasal corneal flap was cut and the interface inoculated with Pseudomonas aeruginosa lipopolysaccharide endotoxin (n = 50) or Palmolive Ultra soap (n = 50). The eyes were randomly assigned to treatment with a mast-cell stabilizer, a nonsteroidal antiinflammatory drug (NSAID), a fluoroquinolone antibiotic agent, a corticosteroid, or left without treatment as a control. Slitlamp examinations and photographs were performed 1, 3, 5, and 7 days postoperatively, and DLK was graded by a masked observer from 0 (no DLK) to stage 4. RESULTS: At the end of the study, 80 eyes were available for evaluation. Ninety-four percent of the untreated eyes developed DLK compared to 56% of eyes treated with NSAIDs and 63% of eyes treated with steroids (P<.05, Fisher exact test). The DLK rates with the mast-cell stabilizer and fluoroquinolone antibiotic agent were 86% and 76%, respectively. The DLK incidence in the latter 2 groups was not significantly different from that in the control eyes (P>.05, Fisher exact test). CONCLUSIONS: Postoperative prophylactic treatment with NSAIDs and corticosteroids led to a statistically significantly lower incidence of postoperative DLK. The study demonstrated that corticosteroids and NSAIDs can be used to treat DLK after LASIK. While steroids are a generally accepted treatment for DLK, NSAIDS may offer an additional potent modality.

Animals↗

Corneal flap complications in refractive surgery: Part 1: development of an experimental animal model.

PURPOSE: To report the outcome, learning curve, and complication rates of an experimental animal model for corneal flaps in refractive surgery. SETTING: Magill Research Center for Vision Correction, Storm Eye Institute, Charleston, South Carolina, USA. METHODS: Corneal flaps with a nasal or a temporal hinge were created in 190 eyes of 95 Dutch Belted rabbits using the Automated Corneal Shaper microkeratome (Bausch & Lomb Surgical). Diffuse lamellar keratitis (DLK) was induced by inoculating the corneal interfaces with 1 of 7 substances. Postoperatively, the eyes were examined with a slitlamp. Special emphasis was placed on corneal flap complications and the relationship between slipped flaps and hinge position and/or inoculation agent. RESULTS: A good corneal flap was achieved in 174 eyes (92%). The eyes with a nasal hinge had a lower incidence of slipped flaps (14%) than eyes with a temporal hinge (37%) (P =.02). CONCLUSION: With the animal model described, corneal flaps were created in a precise and reproducible way in more than 90% of eyes. Nasal hinged flaps showed less postoperative displacements than temporal hinged flaps and are adequate for further study.

Animals↗

Estimating times of surgeries with two component procedures: comparison of the lognormal and normal models.

BACKGROUND: Variability inherent in the duration of surgical procedures complicates surgical scheduling. Modeling the duration and variability of surgeries might improve time estimates. Accurate time estimates are important operationally to improve utilization, reduce costs, and identify surgeries that might be considered outliers. Surgeries with multiple procedures are difficult to model because they are difficult to segment into homogenous groups and because they are performed less frequently than single-procedure surgeries. METHODS: The authors studied, retrospectively, 10,740 surgeries each with exactly two CPTs and 46,322 surgical cases with only one CPT from a large teaching hospital to determine if the distribution of dual-procedure surgery times fit more closely a lognormal or a normal model. The authors tested model goodness of fit to their data using Shapiro-Wilk tests, studied factors affecting the variability of time estimates, and examined the impact of coding permutations (ordered combinations) on modeling. RESULTS: The Shapiro-Wilk tests indicated that the lognormal model is statistically superior to the normal model for modeling dual-procedure surgeries. Permutations of component codes did not appear to differ significantly with respect to total procedure time and surgical time. To improve individual models for infrequent dual-procedure surgeries, permutations may be reduced and estimates may be based on the longest component procedure and type of anesthesia. CONCLUSIONS: The authors recommend use of the lognormal model for estimating surgical times for surgeries with two component procedures. Their results help legitimize the use of log transforms to normalize surgical procedure times prior to hypothesis testing using linear statistical models. Multiple-procedure surgeries may be modeled using the longest (statistically most important) component procedure and type of anesthesia.

Algorithms↗

Evaluation of neodymium:yttrium-aluminum-garnet capsulotomies in eyes implanted with AcrySof intraocular lenses.

PURPOSE: As of December 31, 2000, the neodymium:yttrium-aluminum-garnet (Nd:YAG) laser posterior capsulotomy rate for the Alcon AcrySof intraocular lens (IOL) as measured in our database was 3.3%. This was the lowest of any IOL model used in the United States. Only 12 of 361 cases required treatment. We analyzed possible surgical reasons that may have been responsible for the posterior capsule opacification (PCO) in this small group. Special attention was given to the three surgical factors that we had previously identified as being important for PCO reduction: (1) quality of cortical clean up, (2) type of haptic fixation, and (3) continuous curvilinear capsulorhexis (CCC) size and shape. DESIGN: Comparative autopsy tissue analysis. PARTICIPANTS: Three hundred sixty-one human eyes obtained postmortem with Alcon AcrySof IOLs, accessioned between January 1995 and December 2000 from Lions Eye Banks. METHODS: The eyes were evaluated by the Miyake-Apple posterior photographic technique. MAIN OUTCOME MEASURES: The area and intensity of Soemmering's ring and type of fixation were studied in 361 eyes. The size and shape of the CCC and relation of the CCC edge to the IOL's optic rim were analyzed in 168 eyes. RESULTS: The amount of Soemmering's ring formation was significantly larger in the group of IOLs requiring Nd:YAG capsulotomy (Nd:YAG group). The not in-the-bag fixated IOLs required more Nd:YAG capsulotomies. Although the trend was clear, the number of specimens was not large enough to acquire statistical significance. The Nd:YAG group showed a highly significant difference compared with the No Nd:YAG group with regard to the amount of clock hours of the CCC edge on the optic rim's surface (P < 0.001). Mean CCC diameters were significantly larger in the Nd:YAG group (P < 0.05). CONCLUSIONS: The amount of Soemmering's ring correlates with the quality of cortical clean up. Cells within the Soemmering's ring are the direct precursors of PCO. This study confirms our previous laboratory studies and the clinical assumption that the incidence of PCO and thus the need for Nd:YAG capsulotomy is correlated with the cortical clean up. A second clinical assumption, that poor IOL fixation increases the risk of PCO, is also strongly suggested in this study. This study also verifies the relation of the CCC to PCO and the Nd:YAG laser, namely that a relatively small CCC without tears is best to prevent this complication. Use of a high-quality IOL combined with diligent attention to these three surgical factors should lower further the incidence of PCO.

Acrylic Resins↗

Snowflake degeneration of polymethyl methacrylate posterior chamber intraocular lens optic material: a newly described clinical condition caused by unexpected late opacification of polymethyl methacrylate.

OBJECTIVE: To report 25 cases of gradual, but sometimes progressive, late-postoperative degeneration of polymethyl methacrylate (PMMA) optics of posterior chamber (PC) intraocular lens (IOL) implants, often resulting in a clinically significant visual decrease long after the implantation, sometimes to a severity that required IOL explantation/exchange. DESIGN: Analysis of explanted PC IOLs, clinical histories, and photographs. PARTICIPANTS: We analyzed 25 case histories/photographs and/or explants from 18 patients implanted in the 1980s to mid-1990s with three-piece PC IOLs with PMMA optics and with polypropylene or PMMA haptics. The IOL optic from each case had characteristic snowflake or crystalline opacifications. This condition occurred with more than one manufacturer and in some cases was restricted to certain lot numbers. METHODS: The explanted IOLs (n = 10) were studied by gross inspection and by light and scanning electron microscopy, as well as confocal and energy dispersive spectroscopy. MAIN OUTCOME MEASURES: The snowflake lesions were noted within the IOL optics. The nature of these lesions was investigated. RESULTS: Assimilation of clinical information with pathologic and morphologic profiles of all cases suggested that the snowflake opacification was a small spherical lesion surrounded by an outer pseudocapsule composed of compressed, degenerated PMMA, with a central core containing convoluted fragments of PMMA. The lesions were classified into four clinical and pathologic grades according to their density and severity. CONCLUSIONS: This is the first clinicopathologic correlative report on this complication. We postulate that manufacturing variations in some IOL models fabricated in the 1980s and early 1990s are responsible. The snowflake lesions seem to represent a destruction of the PMMA material. The cluster of lesions in implanted lenses manufactured by Surgidev was less progressive than some other models, including lenses made by IOPTEX Research Corporation. This identification of a condition previously unreported is important to alert clinicians regarding these perplexing lesions that may otherwise be considered idiopathic, with no obvious clinical hint as to their origin. The prevalence noted thus far is still too low to in any way suggest that this condition would occur in 100% of PMMA IOLs from these manufacturers. However, these late-occurring lesions, present in lens models that were implanted in hundreds of thousands of patients in the last decade or so, could have constituted a true epidemic, except that many of the patients are now deceased.

Device Removal↗

Epithelial downgrowth after clear cornea phacoemulsification: report of two cases and review of the literature.

OBJECTIVE: To report two cases of diffuse epithelial downgrowth after clear cornea phacoemulsification and to review the different treatment options for this ominous disease. DESIGN: Two interventional case reports. METHODS: Retrospective review of two eyes from two different patients in whom epithelial downgrowth developed 7 and 3 months after uneventful clear cornea phacoemulsification. In the first case, the epithelial invasion seemed to be growing from the temporal incision site onto the corneal endothelium toward the visual axis. Cryotherapy was applied to the affected cornea, with control of the growing membrane. A penetrating keratoplasty was performed to restore visual function. In the second patient, the membrane was attached to the iris and posterior cornea and was confirmed by diagnostic argon laser photocoagulation. This case was surgically treated with en bloc excision and a corneoscleral graft. MAIN OUTCOME MEASURES: Visual acuity at the final follow-up visit. RESULTS: Surgical treatment of the epithelial downgrowth was different for both patients. In the postoperative period, a best-corrected visual acuity of 20/60 and 20/30 was achieved in each case. No regrowth of the membrane was observed. CONCLUSIONS: Treatment of epithelial downgrowth is controversial. We present two cases of epithelialization of the anterior chamber with either clinical or histologic confirmation after clear cornea sutureless phacoemulsification. Surgical treatment should be attempted promptly to obtain a good visual prognosis.

Aged↗

Refractive Surgery Survey 2001.

In February 2001, a questionnaire on the practice of refractive surgery was sent worldwide to all 8196 members of the American Society of Cataract and Refractive Surgery; 1511 responses (18.4%) were received. Although laser in situ keratomileusis (LASIK) was the most common refractive procedure reported, phakic intraocular lenses, clear lens extraction, and photorefractive keratectomy were also widespread. Nineteen percent of the respondents said they had had refractive surgery, and that group reported performing significantly more procedures than those who had not had a refractive procedure (P < .0001). The most common complication of LASIK was dry eyes, occurring in more than half of the cases in one fourth of the practices; however, only 30% of surgeons said they perform a Schirmer test before surgery. High-volume surgeons reported seeing fewer cases of flap striae (P = .002) and slipped flaps (P = .02) than low-volume surgeons. Seventy-seven percent said that wavefront LASIK ablation will increase the quality of vision and of those already performing wavefront ablation, 92% stated they believe it will improve outcomes.

Adult↗

Effect of haptic angulation on posterior capsule opacification in modern foldable lenses with a square, truncated optic edge.

PURPOSE: To analyze the effect of different haptic angulations on posterior capsule opacification (PCO) in a modern foldable intraocular lens (IOL) with a square-edged optic designed to reduce the incidence of PCO. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Ten Dutch Belted, serum Pasteurella-free pigmented rabbits of the same age and sex had bilateral phacoemulsification with endocapsular IOL implantation. The eyes were implanted with Centerflex IOLs (Rayner) with haptic angulations of 0 degree (n = 8), 5 degrees (n = 4), 10 degrees (n = 4), or 15 degrees (n = 4). RESULTS: There was no statistical difference in central PCO, peripheral PCO, and measured IOL decentration among the angulation groups. CONCLUSION: With the Centerflex IOL, haptic angulation did not seem to be a significant factor influencing PCO. It appears that the barrier effect of the IOL's truncated, square-edged optic overrides the angulation factor in preventing PCO.

Animals↗

Rates and causes of intraoperative removal of foldable and rigid intraocular lenses: clinicopathological analysis of 100 cases.

PURPOSE: To analyze the rates of and reasons for intraoperative explantation of foldable and rigid intraocular lenses (IOLs) to determine the complication profile of each IOL design. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: The study comprised data analysis of foldable (n = 85) and rigid (n = 15) IOL specimens that were explanted immediately after primary implantation. RESULTS: Eighty-five foldable intraoperative explants were accessioned. These comprised 14.5% of the 586 foldable IOL explants received between January 1988 and September 2000. There were 15 rigid poly(methyl methacrylate) (PMMA) intraoperative explants out of 2077 rigid explant specimens (0.7%). Fifty-one (60%) of the foldable IOLs requiring intraoperative explantation were the 1-piece silicone plate-haptic large-hole design, and 29 (34.1%) were the 3-piece silicone polyimide-haptic design. The most frequent reason for explantation of both designs was optic damage, 37.3% in the large-hole design and 55.2% in the polyimide design. Optic damage did not occur in rigid PMMA IOLs. CONCLUSION: Some foldable IOL designs have a higher risk of damage during surgical insertion than rigid designs. Two modern foldable IOLs, the silicone plate-haptic large-hole and the silicone polyimide-haptic, appear to be more prone to damage during folding, loading, and implantation than other IOLs.

Device Removal↗

Evaluation of 3 modern single-piece foldable intraocular lenses: clinicopathological study of posterior capsule opacification in a rabbit model.

PURPOSE: To assess the development of posterior capsule opacification (PCO) with 3 modern single-piece foldable intraocular lenses (IOLs) in a histopathological study and to compare the potential preventive effects of the IOL design and biomaterial in retarding PCO. SETTING: Center for Research on Ocular Therapeutics and Biodevices, Storm Eye Institute, Medical University of South Carolina, Charleston, South Carolina, USA. METHODS: Thirty-one rabbit eyes were randomly operated on with phacoemulsification and implantation of 3 single-piece foldable lenses: a hydrophilic acrylic design, the Rayner Centerflex 570H (n = 11); a hydrophobic acrylic design, the Alcon AcrySof SA30AL (n = 10); and a silicone large-hole plate design, the Staar AA-4203VF (n = 10). Central PCO (CPCO), peripheral PCO (PPCO), and Soemmering's ring formation were evaluated 3 weeks after surgery using the Miyake-Apple posterior photographic technique. Histological sections of each globe were prepared to document capsular bag status and performance of IOL geometry. RESULTS: The acrylic IOLs (Centerflex and AcrySof) had lower CPCO and PPCO scores than the silicone plate IOL (P <.05). There was no significant difference in Soemmering's ring formation among the 3 models. Pathological evaluations revealed effective blockage of migrating lens epithelial cells (LECs) at the site of the truncated optic edge of the Centerflex and AcrySof IOLs, even in the presence of large amounts of retained/regenerative cortical material. CONCLUSIONS: The AcrySof IOL has a hydrophobic surface and the Centerflex a hydrophilic surface, but no correlation to these characteristics could be identified. The single-piece AcrySof optic geometry created a clear-cut barrier effect equal to that of its 3-piece predecessor. The anatomic profile of the Centerflex IOL shows the same characteristics. The optics of both acrylic lenses have square truncated edges that functionally block ingrowth of migrating LECs toward the central visual axis, leaving clear posterior capsules. The square optic edge was an appropriate geometric configuration to create a barrier effect. There was no effect of the biomaterial on PCO prevention.

Acrylic Resins↗

A data mining approach to characterizing medical code usage patterns.

This research describes a synthetic data mining approach to identifying diagnostic (ICD-9) and procedure (CPT) code usage patterns in two US. hospitals, with the goal of determining the adequacy and effectiveness of the current coding classification systems. We combine relative frequency measurements with measures of industry concentration borrowed from industrial economics in order to (1) ascertain the extent to which physicians utilize the available codes in classifying patients and (2) discover the factors that impinge on code usage. Our results partition the domain into areas for which the coding systems perform well and those areas for which the systems perform relatively poorly. The goal is to use this approach to understand how coding systems are used and to highlight areas for targeted improvement of the current coding

Data Interpretation, Statistical↗