Search PubMed⌕ Search

Biomedical subjects

Luigi Mondello

Publications and source records attributed to Luigi Mondello.

35 records · Page 2Linked to original sources

Off-line coupling of non-aqueous reversed-phase and silver ion high-performance liquid chromatography-mass spectrometry for the characterization of rice oil triacylglycerol positional isomers.

The determination of the triacylglycerol (TAG) profile in real world matrices is rather difficult as these compounds present a complex composition and are characterized by similar physico-chemical properties. This investigation is based on the high-performance liquid chromatography (HPLC) multidimensional determination of the TAG profile in terms of TAG species and positional isomers in a rice oil sample. The off-line bi-dimensional system was attained through the coupling of non-aqueous reversed-phase HPLC and silver ion (Ag)-HPLC. The primary column eluate was fractionated and the fractions of interest were then injected onto the secondary column, allowing the separation of several TAG positional isomers, unresolved in the first dimension. Peak assignment was carried out by combining retention data with atmospheric pressure chemical ionisation (APCI) MS spectra information. The fatty acid distribution along the glycerol backbone, determined by Ag-HPLC, was confirmed through diglyceride ion ratios derived from APCI-MS analysis. Method validation, where both precision and accuracy were measured, was carried out in preliminary applications on standard compounds. The analytical results obtained show that rice oil TAGs follow a distribution which can be considered typical for vegetable oils.

Atmospheric Pressure↗

Evaluation of fast gas chromatography and gas chromatography-mass spectrometry in the analysis of lipids.

Fast and conventional gas chromatography (GC) techniques were applied to nine different lipidic matrices (butter, lard, tallow, and peanut, corn, sunflower, soya, olive, menhaden oils). Simultaneous methylic transesterification was performed on all samples prior to GC analysis. Several practical aspects concerning high speed analysis were investigated, such as the great increase in linear velocity, the use of fast temperature ramps, column sample capacity and detection systems. Analytical results showed certain losses in resolution, balanced by a consistent reduction in analysis time. The actual time savings were variable (60-70 min) as they were dependent on the complexity of the sample while the speed enhancement factor was equal to 10.5. Peak identification was achieved by means of different information sources, such as fast GC-mass spectrometry (MS), linear retention indices and comprehensive two-dimensional (2D) gas chromatography group patterns. The method developed was shown to be applicable in routine applications on complex natural samples.

Chromatography, Gas↗

Comprehensive two-dimensional normal-phase (adsorption)-reversed-phase liquid chromatography.

A comprehensive two-dimensional HPLC system has been developed. It is based on the use of a microbore silica column operated in normal-phase (adsorption) mode (NP) in the first dimension and a monolithic type C18 column operated in reversed-phase (RP) mode in the second dimension. The interface was a 10-port, 2-position valve equipped with two storage loops. The first column was operated at a flow rate of 20 microL/min in isocratic mode, while the monolithic column flow rate was 4 mL/min and was operated in gradient mode. The sample loops had a volume of 20 microL each, and the analysis time in the second dimension was 1 min. In this way, every fraction from the first dimension was transferred on-line to the second dimension switching the automated valve every minute. A photodiode array detector has been used after the secondary column. The use of normal- and reversed-phase mode in the two dimensions can be helpful in the separation of complex mixtures of a natural origin that contain uncharged molecules of comparable dimension, different in polarity and hydrophobicity. The use of a microbore column in the first dimension permits the injection of a small volume in the secondary column, making the transfer of incompatible solvents from the first to the second dimension possible. Since the mobile phase in the NP separation is always stronger than the mobile phase at the head of the secondary column operated in RP mode, the initial eluent strength is important in order to obtain an effective focusing of the sample. The use of a monolithic type column in the second dimension permits the performance of very fast analysis operating at higher flow rates without loss of resolution, due to a higher permeability and increased mass-transfer properties in comparison to conventional particulate columns. Due to the brief reconditioning time necessary for monolithic columns, repetitive gradients can be carried out, extending the field of application to mixtures that contain components with different polarities. The utility of the system has been demonstrated in the analysis of the oxygen heterocyclic fraction of cold-pressed lemon oil, made up of coumarins and psoralens. These components may contain hydroxyl, methoxyl, isopentenyl, isopentenyloxyl, and geranyloxyl groups and oxygen-containing modification of the terpenoid side-chain groups, such as epoxides or vicinal diol groups. The relative location of the components in the 2D plane varied in relation to their chemical structure and allowed positive peak identification. The UV spectra recorded with the photodiode array detector supplied additional information that was used for the characterization of the studied sample.

Adsorption↗

Ultra-fast essential oil characterization by capillary GC on a 50 microm ID column.

A 5 m x 50 microm capillary column with 0.05 microm stationary phase film thickness, with a calculated efficiency of almost 20,000 plates per metre (under optimum conditions), was used for very fasthigh resolution GC analysis of lime essential oil. The total analysis time of this volatile essential oil was less than 90 s. Fast GC is shown to be appropriate for essential oil quality assurance analysis, and quantitative results of key components are comparable with those obtained by using conventional GC analysis. The fast GC analysis is approximately 33 times faster than the conventional GC method.

Chromatography, Gas↗

Comprehensive multidimensional GC for the characterization of roasted coffee beans.

The present investigation is based on the separation of one of the most complex food matrices: the roasted coffee bean volatile fraction. Analysis of the two main species of coffee (Arabica/Robusta) was achieved through an effective and simple sampling procedure, headspace solid-phase microextraction (SPME), and the unprecedented resolving power of comprehensive gas chromatography (GC x GC). The combination of these two techniques proved to be a powerful tool for the extraction and separation of coffee volatiles. In fact, thousands of compounds that play various roles in the constitution of coffee aroma profile were resolved in the 2-D contour plot, each occupying a specific position pinpointed by two retention time coordinates. The potential use of this method for the assessment of coffee quality and the detection of commercial fraud is discussed. The potential of GC x GC for identification and classification of unknowns was also demonstrated, as the formation of characteristic patterns for structurally related compounds was observed in the bidimensional chromatogram. Moreover, reproducibility results were supported by the use of an autosampler for SPME applications that allowed any inaccuracy arising from manual handling to be avoided.

Journal Article↗

Effects of pressure drop on absolute retention matching in comprehensive two-dimensional gas chromatography.

Comprehensive two-dimensional gas chromatography (GC x GC) analysis has the capability to resolve many more components of complex mixtures than traditional single column GC analysis. There is an increasing need to provide reliable identification of these separated components; time-of-flight mass spectrometry (TOFMS) is the most appropriate technology to achieve this task. Rather than require MS for all GC x GC separations, it is desirable to assign peak identities to specific peak positions in the GC x GC separation space, and this necessitates matching peak retentions in the two experiments - GC x GC-FID and GC x GC-TOFMS. The atmospheric vs. vacuum outlet conditions confound this task. It is shown here that by employing a supplementary gas supply, provided to a T-union between the column outlet and the MS interface, it is possible to generate 2D chromatograms for GC x GC-FID and GC x GC-TOFMS that are essentially exactly matched. There is no degradation in separation performance or efficiency in the second column in the system interfaced to the T-union. Since the GC x GC-FID experiment uses hydrogen for maximum efficiency, and GC x GC-TOFMS uses helium carrier, translation of (conditions/retentions) must account for the different viscosities of the carrier gases. Translation of conditions is based on well-known principles established in single column analysis. Tabulated data illustrate that retention reproducibility was of the order of better than 4 s for the average first dimension retention difference, and about 40 ms for the average second dimension retention difference when comparing GC x GC-FID and GC x GC-TOFMS results. This should provide considerable support for identification in routine GC x GC-FID analysis of specific sample types, once the peaks in 2D separation space have been assigned identities through GC x GC-TOFMS analysis.

Chromatography, Gas↗

Determination of anthocyanins and related components in red wines by micro- and capillary HPLC.

Anthocyanins and derived components of red wines were determined by microHPLC using a 1 mm ID HPLC column coupled on-line with an MS detector equipped with an ESI (ElectroSpray Ionisation) source. The use of microcolumn HPLC greatly enhanced detection performance, allowing direct identification of components present in the fraction. Nineteen anthocyanins were detected. Fifteen were identified, two were tentatively identified, and only the aglycon of the remaining two components was certainly identified. Six anthocyanin-derived pigments, supposedly formed during wine maturation, were also investigated and found in a wine sample. The analysis of red wine anthocyanins was also carried out by injecting a large sample volume onto a 0.32 mm ID HPLC column, using the column focusing technique, in order to decrease the limit of detection and quantification of components present in a very small amounts.

Anthocyanins↗

Fast GC analysis with a 50 microm ID column: theory, practical aspects, and application to a highly complex sample.

This research focuses on the minimization of GC analysis times through the use of a 5 m x 0.05 mm ID x 0.05 microm (film thickness) column. Experimental minimum plate height (Hmin) and optimum linear velocity values were derived from standard compound applications, under various analytical conditions, and then related to classical chromatographic theory. Deviations from the latter are measured and discussed. Practical aspects linked to the use of such capillaries, such as column sample capacity and detector acquisition rates, are also considered. Furthermore, a fast, and what can be considered a very fast method, were applied to the separation of a fuel sample. Coefficients of variation of elution times and relative peak areas were calculated in the very fast application. All analytical results are compared with those obtained by conventional 0.25 mm ID column applications.

Journal Article↗

Effect of anthocyanins contained in a blackberry extract on the circulatory failure and multiple organ dysfunction caused by endotoxin in the rat.

Anthocyanins are a group of naturally occurring phenolic compounds related to the colouring of plants, flowers and fruits. These pigments are important as quality indicators, chemotaxonomic markers and for their antioxidant activities. Here we have investigated the therapeutic efficacy of anthocyanins contained in a blackberry extract on (i) circulatory failure, (ii), multiple organ dysfunction and (iii) activity of the inducible isoforms of nitric oxide (NO) synthase (iNOS) and cyclooxygenase (COX-2) in anaesthetised rats with endotoxic shock. In a model of endotoxic shock induced by lipopolysaccharide (LPS, E. coli, 10 mg/kg, i.v.) in the rat, pretreatment with anthocyanins present in the blackberry extract (5 mg/kg, i. v. 30 min before LPS) prevented the hypotension induced by LPS. Endotoxaemia also caused rises in the serum levels of (i) glutamyl oxaloacetic transaminase (GOT), glutamyl pyruvic transaminase (GPT), alkaline phosphates and bilirubin (hepatic dysfunction) (ii) creatinine (renal dysfunction), (iii) amylase and lipase (pancreatic injury), (iii) NOx and 6-keto-PGF1 alpha. Anthocyanins attenuated the hepatic and pancreatic injury, the renal dysfunction and decreased NOx and 6-keto-PGF1 alpha levels. Endotoxaemia for 6 h resulted in a substantial increase in iNOS and COX activity in rat lung, which was attenuated in rats pretreated with anthocyanins. Moreover, anthocyanins (0.02 - 0.32 mg/mL) inhibited in vitro iNOS and COX activity from lung of LPS-treated rats. Polymorphonuclear (PMN) infiltration (myeloperoxidase activity), lipid peroxidation (malondialdehyde levels), as well as tissue injury (histological examination) induced by LPS in rat lung and ileum was reduced by anthocyanins (5 mg/kg, i. v. 30 min before LPS). Furthermore, endotoxaemia induced the formation of nitrotyrosine and poly(ADP-ribose) synthetase (PARS) activation as determined by immunohistochemical analysis of lung and ileum tissues. The degree of staining was lowered by anthocyanin treatment. These results indicate that the anthocyanins contained in the blackberry extract exert multiple protective effects in endotoxic shock.

Animals↗

Fast GC for the analysis of citrus oils.

In this investigation, the gas chromatographic (GC) analysis of citrus essential oils is carried out in 3.3 min, with a speed gain of almost 14 times in comparison with traditional GC procedures. The fast method that is developed requires the application of severe experimental conditions (accelerated temperature program rates, high inlet pressures, and split ratios) and, thus, the support of adequate instrumentation. The samples investigated can be considered to be rather complex and, although a slight loss in peak resolution is observed, the overall analytical result is excellent. All data obtained are compared with that of a conventional application on the same matrices. This is done in order to evaluate the effectiveness and advantages of fast GC achieved with narrow bore columns.

Chromatography, Gas↗

Retention time reproducibility in comprehensive two-dimensional gas chromatography using cryogenic modulation. II. An interlaboratory study.

An interlaboratory survey was conducted to determine the reproducibility of retention times in both the first (1D) and second dimension (2D) axes of the two-dimensional separation space, using the longitudinal cryogenic modulation comprehensive two-dimensional gas chromatographic approach. Intralaboratory reproducibility has been demonstrated in part 1 of this investigation [J. Chromatogr. A 968 (2002) 161]. Confidence in absolute retention times (hence component positions) in the two-dimensional separation space is critical to component identification. Comparing data from four independent laboratories, five independent gas chromatographs, five independent LMCS units, and numerous operators has determined that the LMCS cryogenic modulation approach provides reliable comprehensive two-dimensional GC results.

Chromatography, Gas↗

Detailed analysis and group-type separation of natural fats and oils using comprehensive two-dimensional gas chromatography.

Comprehensive gas chromatography (GC x GC) is an adequate methodology for the separation and identification of very complex samples. It is based on the coupling of two capillary columns that each give a different but substantial contribution to the unprecedented resolving power of this technique. The 2D space chromatograms that derive from GC x GC analysis have great potential for identification. This is due to the fact that the contour plot positions, pinpointed by two retention time coordinates, give characteristic patterns for specific families of compounds that can be mathematically translated. This investigation concerned the application of this principle to fatty acid methyl esters that were grouped on an equal double bond number basis. The ester samples were derived from various lipids and all underwent bidimensional analysis on two sets of columns. Peak attribution was supported by mass spectra, linear retention indices and information reported in the literature.

Chromatography, Gas↗

Comparison of fast and conventional GC analysis for citrus essential oils.

This investigation concerns the application of fast GC in the analysis of essential oils. These are complex matrixes that usually undergo GC separation with conventional methods involving long columns, slow programmed temperature rates, and consequently, a high cost in terms of time. Fast GC techniques are based on the use of narrow bore capillary columns that allow the achievement of high-speed separations on complex samples while maintaining excellent resolution. This work saw the application of two methods on five different citrus essential oils and the comparison of all the results obtained.

Chromatography, Gas↗

Protective effects of cyanidin-3-O-glucoside from blackberry extract against peroxynitrite-induced endothelial dysfunction and vascular failure.

Anthocyanins are a group of naturally occurring phenolic compounds as colorants in several plants, flowers and fruits. These pigments have a great importance as quality indicators, as chemotaxonomic markers and antioxidants. The content of blackberry (Rubus species) juice was investigated by HPLC/ESI/MS using narrow bore HPLC columns. Using this method we demonstrated that cyanidin-3-O-glucoside represents about 80% of the total anthocyanin contents in blackberry extract. Here we investigated antioxidant activity of the blackberry juice and cyanidin-3-O-glucoside on the endothelial dysfunction in cells and in vascular rings exposed to peroxynitrite. In human umbilical vein endothelial cells (HUVEC) in vitro, peroxynitrite caused a significant suppression of mitochondrial respiration (38 +/- 2.1% of control cells), as measured by the mitochondrial-dependent conversion of the dye MTT to formazan. Peroxynitrite caused DNA strand breakage (63 +/- 1.9% single strand vs 3 +/- 0.9% single strand in control cells), as measured by the alkaline unwinding assay, and caused an activation of PARS, as measured by the incorporation of radiolabeled NAD(+) to nuclear proteins. Blackberry juice (different dilutions that contained 80 ppm;40 ppm;14.5 ppm of cyanidin-3-O-glucoside) and cyanidin-3-O-glucoside (as chloride) (0.085 microM; 0.028 microM; 0.0085 microM) reduced the peroxynitrite-induced suppression of mitochondrial respiration, DNA damage and PARS activation in HUVECs. Vascular rings exposed to peroxynitrite exhibited reduced endothelium-dependent relaxant responses in response to acetylcholine as well as a vascular contractility dysfunction in response to norepinephrine. The development of this peroxynitrite-induced vascular dysfunction was ameliorated by the blackberry juice (different dilutions that contained 80 ppm;40 ppm;14.5 ppm of cyanidin-3-O-glucoside) and cyanidin-3-O-glucoside (as chloride) (0.085 microM;0.028 microM;0.0085 microM). In conclusion our findings clearly demonstrate that blackberry juice containing cyanidin-3-O-glucoside is a scavenger of peroxynitrite and that exert a protective effect against endothelial dysfunction and vascular failure induced by peroxynitrite.

Anthocyanins↗

Characterization of the anthocyanin fraction of sicilian blood orange juice by micro-HPLC-ESI/MS.

Anthocyanins of red orange juices were analyzed by micro-HPLC coupled on-line with an MS detector equipped with an ESI source. The use of microcolumn HPLC greatly enhanced detection performance, allowing direct identification of the anthocyanins present in the orange juices. The use of a soft ionization technique allows detection of the molecular ions of the aglycons. Eight components were identified, five of them for the first time in red orange juice. Three additional anthocyanins were detected, of which only the aglycon was identified.

Anthocyanins↗

Protective effects of anthocyanins from blackberry in a rat model of acute lung inflammation.

Anthocyanins are a group of naturally occuring phenolic compounds related to the coloring of plants, flowers and fruits. These pigments are important as quality indicators, as chemotaxonomic markers and for their antioxidant activities. Here, we have investigated the therapeutic efficacy of anthocyanins contained in blackberry extract (cyanidin-3-O-glucoside represents about 80% of the total anthocyanin contents) in an experimental model of lung inflammation induced by carrageenan in rats. Injection of carrageenan into the pleural cavity elicited an acute inflammatory response characterized by fluid accumulation which contained a large number of neutrophils as well as an infiltration of polymorphonuclear leukocytes in lung tissues and subsequent lipid peroxidation, and increased production of nitrite/nitrate (NOx) and prostaglandin E2 (PGE2). All parameters of inflammation were attenuated in a dose-dependent manner by anthocyanins (10, 30 mg kg(-1) 30 min before carrageenan). Furthermore, carrageenan induced an upregulation of the adhesion molecule ICAM-1, nitrotyrosine and poly (ADP-ribose) synthetase (PARS) as determined by immunohistochemical analysis of lung tissues. The degree of staining was lowered by anthocyanins treatment. Thus, the anthocyanins contained in the blackberry extract exert multiple protective effects in carrageenan-induced pleurisy.

Acute Disease↗

Characterisation of lavender essential oils by using gas chromatography-mass spectrometry with correlation of linear retention indices and comparison with comprehensive two-dimensional gas chromatography.

Nine samples of lavender essential oil were analysed by GC-MS using low-polarity and polar capillary columns. Linear retention indices (LRI) were calculated for each component detected. Characterisation of the individual components making up the oils was performed with the use of an mass spectrometry (MS) library developed in-house. The MS library was designed to incorporate the chromatographic data in the form of linear retention indices. The MS search routine used linear retention indices as a post-search filter and identification of the "unknowns" was made more reliable as this approach provided two independent parameters on which the identification was based. Around 70% of the total number of components in each sample were reliably characterised. A total of 85 components were identified. Semi-quantitative analysis of the same nine samples was performed by gas chromatography (GC) with flame ionisation detection (FID). The identified components accounted for more than 95% of each oil. By comparing the GC-MS results with the results from the GCxGC-FID analysis of a lavender essential oil, many more components could be found within the two-dimensional separation space.

Chromatography, Gas↗