Search PubMed⌕ Search

Biomedical subjects

Lucas M Bachmann

Publications and source records attributed to Lucas M Bachmann.

At least 19 recordsLinked to original sources

Does the Angiotensin-converting enzyme (ACE) gene insertion/deletion polymorphism modify the response to ACE inhibitor therapy?--A systematic review.

BACKGROUND: Pharmacogenetic testing to individualize ACE inhibitor therapy remains controversial. We conducted a systematic review to assess the effect modification of the insertion/deletion (I/D) polymorphism of the ACE gene on any outcome in patients treated with ACE inhibitors for cardiovascular and/or renal disease. METHODS: Our systematic review involved searching six electronic databases, then contacting the investigators (and pharmaceutical industry representatives) responsible for the creation of these databases. Two reviewers independently selected relevant randomized, placebo-controlled trials and abstracted from each study details on characteristics and quality. RESULTS: Eleven studies met our inclusion criteria. Despite repeated efforts to contact authors, only four of the eleven studies provided sufficient data to quantify the effect modification by genotypes. We observed a trend towards better response to ACE inhibitors in Caucasian DD carriers compared to II carriers, in terms of blood pressure, proteinuria, glomerular filtration rate, ACE activity and progression to end-stage renal failure. Pooling of the results was inappropriate, due to heterogeneity in ethnicity, clinical domains and outcomes. CONCLUSION: Lack of sufficient genetic data from the reviewed studies precluded drawing any convincing conclusions. Better reporting of genetic data are needed to confirm our preliminary observations concerning better response to ACE inhibitors among Caucasian DD carriers as compared to II carriers.

Journal Article↗

A randomized trial of ways to describe test accuracy: the effect on physicians' post-test probability estimates.

BACKGROUND: Some people believe that likelihood ratios provide diagnostic information that is more useful than sensitivity and specificity estimates. OBJECTIVE: To assess how physicians' estimates about probability of illness are affected by the presentation of a diagnostic test's value as an estimate of sensitivity and specificity versus a likelihood ratio or an inexact numerical graphic. DESIGN: Random assignment of vignettes with different presentation formats of diagnostic test accuracy. SETTING: Auditorium at a continuing medical education conference. PARTICIPANTS: 183 physicians. INTERVENTION: After estimating probabilities of 6 common illnesses described in patient vignettes, physicians reviewed pertinent test results presented in 1 of 3 formats. MEASUREMENTS: Physicians' probability estimates of illness before and after receiving test information, and post-test probability estimates based on the Bayes theorem. RESULTS: Absolute percentage point differences between the physicians' estimated and the Bayes-based post-test probabilities varied from -7 to 31, from -7 to 28, and from 1 to 29 for the sensitivity and specificity, likelihood ratio, and graphical groups, respectively. Mean differences of probability estimates between the sensitivity and specificity and the likelihood ratio groups were small for all vignettes (-2 to 3 percentage points; summary mean z value across the 6 vignettes, 0.04 [95% CI, -0.14 to 0.21]). LIMITATIONS: The small pool of participants (who were potentially selected) and the limited number of vignettes prevented a more detailed analysis of relationships between the interpreted strength of diagnostic evidence and estimations of illness probability. CONCLUSIONS: These findings suggest that presenting diagnostic test accuracy with likelihood ratios does not affect some physicians' estimates of illness probability compared with presenting diagnostic test results as sensitivity and specificity.

Adult↗

Ocular pulse amplitude after trabeculectomy.

BACKGROUND: The ocular pulse amplitude (OPA) is the difference between the minimum and maximum values of the pulsatile intraocular pressure (IOP) wave contour. The OPA depends on ocular perfusion and IOP, which are both affected by a trabeculectomy (TE). The aim of this study was to investigate how the OPA changes after TE and whether an early change in OPA can be used as a prognostic marker for a successful long-term outcome. METHODS: Fourteen consecutive patients (26-84 years old) with medically uncontrolled primary open-angle or pseudoexfoliation glaucoma were included in the study. IOP and OPA were measured with a dynamic contour tonometer before and after TE on days -1, +1, +7, +14, +21, +28, +42, +56, +70, and +84. The OPA of the contralateral eye was used to control for variations in systemic haemodynamics. TE was regarded as successful if a persistent drop in IOP of at least 20% without the use of IOP-lowering treatment was achieved. Data were analysed using receiver operating characteristic curves, Kaplan-Meier survival curves and Mann-Whitney two-sample analysis. RESULTS: Five out of 14 TEs had an entirely successful outcome. The other 9 patients required additional interventions such as suturolysis, needling of subconjunctival scar tissue and antimetabolite injections during the 3-month period after the TE. On the first day after surgery, OPA decreased in 12 patients and increased in 2 patients compared with the preoperative measurements. In the 5 patients with a successful long-term outcome, OPA dropped by 3.38+/-1.79 mmHg (mean+/-SE), whereas the initial OPA drop in those cases that required additional interventions was 0.62+/-1.81 mmHg only (p<0.01). IOP dropped by 13.10+/-2.14 mmHg in the successful group and by 5.84+/-2.51 mmHg in the unsuccessful group (p=0.19). Kaplan-Meier estimates of survival showed that patients with an initial OPA drop of more than 2.0 mmHg had a significantly better chance of an entirely uncomplicated 3-month outcome after TE than patients with an initial OPA drop of less than 2.0 mmHg (log rank p<0.01). CONCLUSION: This pilot study indicates that an early drop in OPA of more than 2.0 mmHg after TE may be a good prognostic parameter for successful long-term control of IOP.

Adult↗

Consequences of different diagnostic "gold standards" in test accuracy research: Carpal Tunnel Syndrome as an example.

Test accuracy studies assume the existence of a well-defined illness definition and clear-cut diagnostic gold standards or reference standards. However, in clinical reality illness definitions may be vague or a mere description of a set of manifestations, mostly clinical signs and symptoms. This can lead to disagreements among experts about the correct classification of an illness and the adequate reference standard. Using data from a diagnostic accuracy study in carpal tunnel syndrome, we explored the impact of different definitions on the estimated test accuracy and found that estimated test performance characteristics varied considerably depending on the chosen reference standard. In situations without a clear-cut illness definition, randomized controlled trials may be preferable to test accuracy studies for the evaluation of a novel test. These studies do not determine the diagnostic accuracy, but the clinical impact of a novel test on patient management and outcome.

Carpal Tunnel Syndrome↗

The accuracy of maternal anthropometry measurements as predictor for spontaneous preterm birth--a systematic review.

OBJECTIVE: To assess the accuracy with which antenatal maternal anthropometric measurements predict the risk spontaneous preterm birth. STUDY DESIGN: (1) DATA SOURCES: Studies were identified without language restrictions from MEDLINE, EMBASE, PASCAL, BIOSIS, the Cochrane Library, MEDION, National Research Register, SCISEARCH and Conference Papers, and manual searching of bibliographies of known primary and review articles, and contact with authors. (2) STUDY SELECTION AND DATA EXTRACTION: Studies were selected if they used antenatal maternal anthropometric features (pre-pregnancy weight, maternal pregnancy weight gain and maternal height) to predict spontaneous preterm birth. Two reviewers independently selected studies and extracted data on their characteristics, quality and accuracy. Accuracy data were used to form 2 x 2 contingency tables of the maternal anthropometric test results with spontaneous preterm birth as the reference standard. (3) DATA SYNTHESIS: Heterogeneity assessments were carried out to aid the decision regarding pooling of the accuracy results. Likelihood ratios for positive (LR+) and negative (LR-) test results were calculated, and summary estimates were produced in absence of heterogeneity of the accuracy results. RESULTS: There were eight primary accuracy articles that met the selection criteria, which included a total of 122,647 asymptomatic women. There were six studies on pre-pregnancy weight where five measured the body mass index (BMI) and one used an arbitrary measure. There were four studies on the adequacy of pregnancy weight gain and two studies on maternal height as a predictor for the risk of preterm birth. One article contributed three studies, while two articles provided two studies each. The commonest reference standard used was birth before 37 weeks' gestation. None of the studies fulfilled the ideal test accuracy study criteria. There was heterogeneity in the accuracy results of pre-pregnancy BMI but not in the adequacy of weight gain. All three maternal anthropometric features were poor predictors of preterm labour. Pre-pregnancy BMI is a poor predictor of preterm birth before 37 weeks' gestation (LR+ that ranged from 0.96 (95% confidence interval (CI) 0.66-1.40) to 1.75 (95% CI 1.33-2.31)) as are the adequacy of pregnancy weight gain (summary LR+ of 1.81, 95% CI 1.45-2.30) and short maternal height (LR+ of 1.79 (95% CI 1.27-2.52). CONCLUSION: Routine antenatal maternal anthropometric measurements are not useful in predicting the risk of preterm birth before 37 weeks' gestation. Further studies should address their use in combination with other test but need to use a more clinically appropriate reference standard of preterm birth, such as birth before 32-34 weeks' gestation, and improve on the quality of study design.

Anthropometry↗

Diagnostic value of sonography in patients with suspected carpal tunnel syndrome: a prospective study.

OBJECTIVE: To determine the diagnostic value of sonography in patients with suspected carpal tunnel syndrome (CTS). METHODS: We conducted a prospective study of 110 wrists in 74 consecutive patients with suspected CTS who had been referred to a tertiary care center. We determined the largest cross-sectional area of the median nerve at the carpal tunnel. Because of the lack of a universally accepted reference standard, we first examined the association of sonography with nerve conduction. Then, we compared sonography with a reference standard based on the combination of nerve conduction studies and signs and symptoms. Sonography and reference standard tests were performed independently and interpreted under blinded conditions. Based on a fitted receiver operating characteristic curve, we estimated likelihood ratios (LRs) and posttest probabilities for different cutoffs. RESULTS: There was a high concordance between sonography and nerve conduction. Based on the combined reference standard, a cutoff of 10 mm(2) resulted in approximately equal sensitivity and specificity, but only moderate LRs. A cutoff of <8 mm(2) had satisfactory power to rule out CTS: the fitted-negative LR was 0.13. Conversely, a cutoff of > or =12 mm(2) had excellent power to rule in CTS, with a fitted-positive LR of 19.9. For nerves > or =12 mm(2) and a pretest probability of 70% expected in patients with suspected CTS in tertiary care, we found a posttest probability of CTS of 98%. CONCLUSION: Depending on setting and purpose, different cutoff values for the largest cross-sectional area may be used to accurately rule in or rule out CTS. Using sonography as a first-line test may cost-effectively reduce the number of nerve conduction studies in patients with suspected CTS. A large-scale, randomized controlled trial is required to determine the effects of sonography on clinical outcomes, the number of nerve conduction studies performed, and the total cost.

Adult↗

Value of supplemental interventions to enhance the effectiveness of physical exercise during respiratory rehabilitation in COPD patients. A systematic review.

BACKGROUND: There is a controversy about the additional benefit of various supplemental interventions used in clinical practice to further enhance the effectiveness of respiratory rehabilitation in patients with Chronic obstructive pulmonary disease (COPD). The aim of this research was to assess randomised controlled trials (RCTs) testing the additional benefit of supplemental interventions during respiratory rehabilitation in COPD patients. METHODS: Systematic review with literature searches in six electronic databases, extensive hand-searching and contacting of authors. Two reviewers selected independently eligible RCTs, rated the methodological quality and extracted the data, which were analyzed considering the minimal important difference of patient-important outcomes where possible. FINDINGS: We identified 20 RCTs whereof 18 provided sufficient data for analysis. The methodological quality was low and sample sizes were too small for most trials to produce meaningful results (median total sample size = 28). Data from five trials showed that supplemental oxygen during exercise did not have clinically meaningful effects on health-related quality of life while improvements of exercise capacity may be even larger for patients exercising on room air. RCTs of adding assisted ventilation, nutritional supplements or a number of anabolically acting drugs do not provide sufficient evidence for or against the use any of these supplemental interventions. INTERPRETATION: There is insufficient evidence for most supplemental interventions during respiratory rehabilitation to estimate their additional value, partly due to methodological shortcomings of included RCTs. Current data do not suggest benefit from supplemental oxygen during exercise, although the methodological quality of included trials limits conclusions. To appropriately assess any of the various supplemental interventions used in clinical practice, pragmatic trials on respiratory rehabilitation of COPD patients need to consider methodological aspects as well as appropriate sample sizes.

Anabolic Agents↗

The accuracy of the Ottawa knee rule to rule out knee fractures: a systematic review.

BACKGROUND: The Ottawa knee rule is a clinical decision aid that helps rule out fractures and avoid unnecessary radiography. PURPOSE: To summarize evidence about the accuracy of the Ottawa knee rule. DATA SOURCES: Relevant English- and non-English-language articles were identified from PreMEDLINE and MEDLINE (1966-2003), EMBASE (1980-2003), CINAHL (1982-2003), BIOSIS (1990-2003), the Cochrane Library (2002, Issue 3), the Science Citation Index database, reference lists of included studies, and experts. STUDY SELECTION: Articles were included if they reported enough information to determine the sensitivity and specificity of the Ottawa knee rule for detecting fractures confirmed either radiologically or in combination with follow-up. DATA EXTRACTION: Two reviewers independently extracted data on study samples, the ways that the Ottawa knee rule was used, and methodologic characteristics of studies. DATA SYNTHESIS: Of 11 identified studies, 6 involving 4249 adult patients were considered appropriate for pooled analysis. The pooled negative likelihood ratio was 0.05 (95% CI, 0.02 to 0.23), the pooled sensitivity was 98.5% (CI, 93.2% to 100%), and the pooled specificity was 48.6% (CI, 43.4% to 51.0%). CONCLUSION: A negative result on an Ottawa knee rule test accurately excluded knee fractures after acute knee injury. However, because the rule is calibrated toward 100% sensitivity and actual fracture prevalences are usually low, large-scale, multicentered studies are still needed to establish the cost-effectiveness of routinely implementing the rule.

Decision Support Techniques↗

Minimal changes of serum creatinine predict prognosis in patients after cardiothoracic surgery: a prospective cohort study.

Acute renal failure increases risk of death after cardiac surgery. However, it is not known whether more subtle changes in renal function might have an impact on outcome. Thus, the association between small serum creatinine changes after surgery and mortality, independent of other established perioperative risk indicators, was analyzed. In a prospective cohort study in 4118 patients who underwent cardiac and thoracic aortic surgery, the effect of changes in serum creatinine within 48 h postoperatively on 30-d mortality was analyzed. Cox regression was used to correct for various established demographic preoperative risk indicators, intraoperative parameters, and postoperative complications. In the 2441 patients in whom serum creatinine decreased, early mortality was 2.6% in contrast to 8.9% in patients with increased postoperative serum creatinine values. Patients with large decreases (DeltaCrea <-0.3 mg/dl) showed a progressively increasing 30-d mortality (16 of 199 [8%]). Mortality was lowest (47 of 2195 [2.1%]) in patients in whom serum creatinine decreased to a maximum of -0.3 mg/dl; mortality increased to 6% in patients in whom serum creatinine remained unchanged or increased up to 0.5 mg/dl. Mortality (65 of 200 [32.5%]) was highest in patients in whom creatinine increased > or =0.5 mg/dl. For all groups, increases in mortality remained significant in multivariate analyses, including postoperative renal replacement therapy. After cardiac and thoracic aortic surgery, 30-d mortality was lowest in patients with a slight postoperative decrease in serum creatinine. Any even minimal increase or profound decrease of serum creatinine was associated with a substantial decrease in survival.

Adolescent↗

The accuracy of various tests for bacterial vaginosis in predicting preterm birth: a systematic review.

OBJECTIVE: To determine the accuracy with which various types of tests for bacterial vaginosis predict spontaneous preterm birth in pregnant women. DATA SOURCES: Studies were identified without language restrictions through nine different databases, and manual searching of bibliographies of known primary and review articles. STUDY SELECTION AND DATA EXTRACTION: There are four different bacterial vaginosis testing methods: Gram staining tests using either Nugent's or Spiegel's criteria, and gas liquid chromatography are laboratory based, and the fourth method uses clinical (Amsel's) criteria to diagnose bacterial vaginosis. Two reviewers independently selected studies and extracted data on their characteristics, quality and accuracy. Accuracy data were used to form 2 x 2 contingency tables of the bacterial vaginosis test results with spontaneous preterm birth as the reference standard. DATA SYNTHESIS: Data on asymptomatic women and women with symptoms of threatened preterm labour were analysed separately. Data were pooled to produce summary estimates of likelihood ratios for positive (LR+) and negative (LR-) test results for the various types of tests. RESULTS: There were 18 primary articles, involving altogether 17,868 women. There was unexplained heterogeneity in the meta-analyses of the accuracy results, which requires caution in their interpretation. Meta-analyses of studies testing asymptomatic women in the second trimester showed that clinical criteria had a LR+ of 0.98 (95% confidence interval 0.59 to 1.6) and a LR- of 1.00 (0.93 to 1.1), Gram staining (Nugent's criteria) had a LR+ of 1.6 (1.4 to 1.9) and a LR- of 0.9 (0.8 to 0.9), and Gram staining (Spiegel's criteria) had a LR+ of 2.4 (1.4 to 4.9) and a LR- of 0.81 (0.64 to 1.0). Among symptomatic women, Gram staining (Spiegel's criteria) had a LR+ of 1.3 (1.0 to 1.6) and LR- of 0.9 (0.7 to 1.0). CONCLUSION: There was a lack of difference in the accuracy of the various bacterial vaginosis tests for predicting preterm birth in both asymptomatic and symptomatic women of threatened preterm labour.

Bacteriological Techniques↗

Comparison of dynamic contour tonometry with goldmann applanation tonometry.

PURPOSE: The dynamic contour tonometer (DCT; Pascal tonometer) is a novel tonometer designed to measure intraocular pressure (IOP) independent of corneal properties. The purpose of this study was a comparison of the DCT with the Goldmann applanation tonometer (GAT) with respect to mean of IOP readings, the influence of ocular structural factors on IOP readings, and both intra- and interobserver variability, in a large group of healthy subjects. METHODS: In a prospective study of 228 eyes, IOP measurements by GAT and DCT were compared, and the effects of central corneal thickness (CCT), corneal curvature, axial length, and anterior chamber depth were analyzed. To evaluate intra- and interobserver variability, IOP was measured in eight eyes by four observers. RESULTS: There was a high concordance between the IOP readings obtained by DCT and GAT. However, IOP readings were consistently higher with DCT than with GAT (median difference: +1.7 mm Hg, interquartile range [25th-75th percentile] = 0.8-2.7 mm Hg). In contrast to GAT, multivariable regression analysis showed no significant effect of corneal thickness, corneal curvature, astigmatism, anterior chamber depth, and axial length on DCT readings. For repeated measurements the intraobserver variability was 0.65 mm Hg for the DCT and 1.1 mm Hg for the GAT (P = 0.008). Interobserver variability was 0.44 mm Hg for the DCT and 1.28 mm Hg for the GAT (P = 0.017). CONCLUSIONS: IOP measurements by DCT are highly concordant with IOP readings obtained from GAT but do not vary in CCT and have a lower intra- and interobserver variability. DCT seems to be an appropriate method of tonometry for routine clinical use.

Astigmatism↗

Oral purified bacterial extracts in chronic bronchitis and COPD: systematic review.

BACKGROUND: Oral lyophilized extracts of bacteria species have been used since the early 1970s to improve symptoms and to prevent exacerbations in COPD patients. The value of these treatments, which are thought to be immunomodulating, is poorly understood. Our aim was to quantify the efficacy of oral bacteria extracts in patients with chronic bronchitis and COPD. DESIGN: Systematic review of randomized trials. DATA SOURCES: Electronic databases, bibliographies, and contact with authors and manufacturers. REVIEW METHODS: Randomized comparisons of oral purified bacterial (active) extracts with placebo or no treatment (control) were selected. Meta-analyses were performed using fixed and random-effects models, and the results were expressed as relative risk (RR), odds ratio (OR), number needed to treat for one to benefit (NNTB), or number needed to treat for one to be harmed (NNTH), with 95% confidence interval (CI). RESULTS: Thirteen trials (1,971 patients), most of which were of low quality, tested OM-85BV (Broncho-Vaxom; OM Pharma; Geneva, Switzerland), LW-50020 (Luivac; ALTANA Pharma; Bad Homburg, Germany), or SL-04. Two trials (731 patients) had appropriate methodologies and reported on exacerbations. The RR in favor of the oral bacterial extract (active) was 0.83 (95% CI, 0.55 to 1.25), and the NNTB was 15.4 (95% CI, 5.5 to infinity; NNTH, 27.5). Five trials (591 patients) reported on observer-assessed improvement of symptoms RR in favor of active extracts was 0.57 (95% CI, 0.49 to 0.66), and the NNTB was 4 (95% CI, 2.8 to 5.4). Two trials (n = 344), reported on patient-assessed improvement (RR, 0.44; 95% CI, 0.31 to 0.61) [NNTB, 4; 95% CI, 3.0 to 5.9]. In two trials (163 patients), the average duration of an exacerbation was shorter with the active extracts (weighted mean difference, -2.7 days; 95% CI, -3.5 to -1.8). Itching or cutaneous eruptions was reported in 3.3% of patients (four trials; 802 patients) who received active extracts compared with 1.0% of control subjects (OR, 2.94 95% CI, 1.12 to 7.69) [NNTH, 50; 95% CI, 14 to 161]. Urologic problems (two trials; 671 patients) were reported in 8% of patients who received active extracts compared with 3.0% of control subjects (OR, 2.62; 95% CI, 1.35 to 5.11) [NNTH, 22; 95% CI, 10 to 61]. CONCLUSIONS: Oral purified bacterial extracts improve symptoms in patients with chronic bronchitis and COPD. There is not enough evidence to suggest that they prevent exacerbations. Cutaneous and urologic adverse effects are common.

Administration, Oral↗

Systematic reviews with individual patient data meta-analysis to evaluate diagnostic tests.

Systematic literature reviews with meta-analysis of reported data in diagnostic research studies about the accuracy of tests assist clinicians in decision-making. However, there are limitations to this approach as the analysis of such data often does not allow reviewers to explore the diagnostic information gained from combinations of tests. In recent years meta-analysis of individual patient data (IPD) has been introduced as gold standard analytic approach in systematic reviews of randomised controlled trials. Application of IPD meta-analysis in systematic reviews of diagnostic tests can allow advanced analysis to decipher the real value of testing. In particular, the additional information provided by testing can be examined in light of the information already known from history and examination. To our knowledge there are no IPD meta-analyses in diagnostic research so far. This commentary aims to highlight the benefits of IPD meta-analysis in the diagnostic domain and demonstrates how strategies for diagnostic work-up of women with postmenopausal bleeding could be improved using this approach in systematic reviews of diagnostic research on accuracy of ultrasound and hysteroscopy.

Diagnostic Tests, Routine↗

A readers' guide to the interpretation of diagnostic test properties: clinical example of sepsis.

BACKGROUND: One of the most challenging practical and daily problems in intensive care medicine is the interpretation of the results from diagnostic tests. In neonatology and pediatric intensive care the early diagnosis of potentially life-threatening infections is a particularly important issue. FOCUS: A plethora of tests have been suggested to improve diagnostic decision making in the clinical setting of infection which is a clinical example used in this article. Several criteria that are critical to evidence-based appraisal of published data are often not adhered to during the study or in reporting. To enhance the critical appraisal on articles on diagnostic tests we discuss various measures of test accuracy: sensitivity, specificity, receiver operating characteristic curves, positive and negative predictive values, likelihood ratios, pretest probability, posttest probability, and diagnostic odds ratio. CONCLUSIONS: We suggest the following minimal requirements for reporting on the diagnostic accuracy of tests: a plot of the raw data, multilevel likelihood ratios, the area under the receiver operating characteristic curve, and the cutoff yielding the highest discriminative ability. For critical appraisal it is mandatory to report confidence intervals for each of these measures. Moreover, to allow comparison to the readers' patient population authors should provide data on study population characteristics, in particular on the spectrum of diseases and illness severity.

Bayes Theorem↗