Search PubMed⌕ Search

Biomedical subjects

Lori E Dodd

Publications and source records attributed to Lori E Dodd.

4 recordsLinked to original sources

Correcting log ratios for signal saturation in cDNA microarrays.

MOTIVATION: Pixel saturation occurs when the pixel intensity exceeds a threshold and the recorded pixel intensity is truncated. Microarray experiments are commonly afflicted with saturated pixels. As a result, estimators of gene expression are biased, with the amount of bias increasing as a function of the proportion of pixels saturated. Saturation is directly related to the photomultiplier tube (PMT) voltage settings and RNA abundance and is not necessarily associated with poor array or poor spot quality. When choosing PMT settings, higher PMT settings are desired because of improved signal-to-noise ratios of low-intensity spots. This improved signal is somewhat offset by saturation of high-intensity spots. In practice, spots with saturated pixels are discarded or the biased value is used. Neither of these approaches is appealing, particularly the former approach when a highly expressed gene is discarded because of saturation. RESULTS: We present a method to correct for saturation using pixel-level data. The method is based on a censored regression model. Evaluations on several arrays indicate that the method performs well. Simulation studies suggest that the method is robust under certain model violations.

Algorithms↗

Assessment methodologies and statistical issues for computer-aided diagnosis of lung nodules in computed tomography: contemporary research topics relevant to the lung image database consortium.

Cancer of the lung and bronchus is the leading fatal malignancy in the United States. Five-year survival is low, but treatment of early stage disease considerably improves chances of survival. Advances in multidetector-row computed tomography technology provide detection of smaller lung nodules and offer a potentially effective screening tool. The large number of images per exam, however, requires considerable radiologist time for interpretation and is an impediment to clinical throughput. Thus, computer-aided diagnosis (CAD) methods are needed to assist radiologists with their decision making. To promote the development of CAD methods, the National Cancer Institute formed the Lung Image Database Consortium (LIDC). The LIDC is charged with developing the consensus and standards necessary to create an image database of multidetector-row computed tomography lung images as a resource for CAD researchers. To develop such a prospective database, its potential uses must be anticipated. The ultimate applications will influence the information that must be included along with the images, the relevant measures of algorithm performance, and the number of required images. In this article we outline assessment methodologies and statistical issues as they relate to several potential uses of the LIDC database. We review methods for performance assessment and discuss issues of defining "truth" as well as the complications that arise when truth information is not available. We also discuss issues about sizing and populating a database.

Algorithms↗

A cautionary note on the robustness of latent class models for estimating diagnostic error without a gold standard.

Modeling diagnostic error without a gold standard has been an active area of biostatistical research. In a majority of the approaches, model-based estimates of sensitivity, specificity, and prevalence are derived from a latent class model in which the latent variable represents an individual's true unobserved disease status. For simplicity, initial approaches assumed that the diagnostic test results on the same subject were independent given the true disease status (i.e., the conditional independence assumption). More recently, various authors have proposed approaches for modeling the dependence structure between test results given true disease status. This note discusses a potential problem with these approaches. Namely, we show that when the conditional dependence between tests is misspecified, estimators of sensitivity, specificity, and prevalence can be biased. Importantly, we demonstrate that with small numbers of tests, likelihood comparisons and other model diagnostics may not be able to distinguish between models with different dependence structures. We present asymptotic results that show the generality of the problem. Further, data analysis and simulations demonstrate the practical implications of model misspecification. Finally, we present some guidelines about the use of these models for practitioners.

Biometry↗

Partial AUC estimation and regression.

Accurate diagnosis of disease is a critical part of health care. New diagnostic and screening tests must be evaluated based on their abilities to discriminate diseased from nondiseased states. The partial area under the receiver operating characteristic (ROC) curve is a measure of diagnostic test accuracy. We present an interpretation of the partial area under the curve (AUC), which gives rise to a nonparametric estimator. This estimator is more robust than existing estimators, which make parametric assumptions. We show that the robustness is gained with only a moderate loss in efficiency. We describe a regression modeling framework for making inference about covariate effects on the partial AUC. Such models can refine knowledge about test accuracy. Model parameters can be estimated using binary regression methods. We use the regression framework to compare two prostate-specific antigen biomarkers and to evaluate the dependence of biomarker accuracy on the time prior to clinical diagnosis of prostate cancer.

Area Under Curve↗