Search PubMed⌕ Search

Biomedical subjects

Liang-Chih Wu

Publications and source records attributed to Liang-Chih Wu.

3 recordsLinked to original sources

Quantification method in [18F]fluorodeoxyglucose brain positron emission tomography using independent component analysis.

OBJECTIVE: To extract accurate image-derived input functions from dynamic brain positron emission tomography images (DBPIs) using independent component analysis (ICA). METHODS: A modified linear model with haematocrit correction was used to improve the accuracy of input functions estimated by independent component analysis and to reduce the error of quantitative analysis. Two types of material were examined: (1) a simulated dynamic phantom with a three-compartment, four-parameter model; (2) clinical 2-h DBPIs with a standard plasma sampling procedure. The input function was extracted from DBPIs using independent component analysis. The modified linear model with haematocrit correction was used to obtain the independent component analysis-estimated input function (Iica). For comparison, the input function derived from the last three blood samples (Iest) was used. The image-derived input functions (Iica and Iest) were compared with the input function from blood sampling (Itp). The mean percentage error of the metabolic rate of [F]-2-fluoro-2-deoxy-D-glucose (MRFDG) was calculated for both Iica and Iest against that of Itp. RESULTS: In simulated studies, the mean percentage errors of MRFDG between true simulated and estimated values of Iest and Iica were 8.2% and 4.2%, respectively. In clinical studies, six clinical cases were collected. The mean percentage errors and standard deviations of MRFDG with Iest and Iica were 12.6+/-7.5% and 7.7+/-3.3%, respectively. CONCLUSIONS: We have proposed a technique for estimating image-derived input functions using independent component analysis without blood sampling. The results of our method were highly correlated with those from standard blood sampling, and more accurate than those of other methods proposed previously.

Algorithms↗

Estimating the input function non-invasively for FDG-PET quantification with multiple linear regression analysis: simulation and verification with in vivo data.

A novel statistical method, namely Regression-Estimated Input Function (REIF), is proposed in this study for the purpose of non-invasive estimation of the input function for fluorine-18 2-fluoro-2-deoxy- d-glucose positron emission tomography (FDG-PET) quantitative analysis. We collected 44 patients who had undergone a blood sampling procedure during their FDG-PET scans. First, we generated tissue time-activity curves of the grey matter and the whole brain with a segmentation technique for every subject. Summations of different intervals of these two curves were used as a feature vector, which also included the net injection dose. Multiple linear regression analysis was then applied to find the correlation between the input function and the feature vector. After a simulation study with in vivo data, the data of 29 patients were applied to calculate the regression coefficients, which were then used to estimate the input functions of the other 15 subjects. Comparing the estimated input functions with the corresponding real input functions, the averaged error percentages of the area under the curve and the cerebral metabolic rate of glucose (CMRGlc) were 12.13+/-8.85 and 16.60+/-9.61, respectively. Regression analysis of the CMRGlc values derived from the real and estimated input functions revealed a high correlation (r=0.91). No significant difference was found between the real CMRGlc and that derived from our regression-estimated input function (Student's t test, P>0.05). The proposed REIF method demonstrated good abilities for input function and CMRGlc estimation, and represents a reliable replacement for the blood sampling procedures in FDG-PET quantification.

Algorithms↗