FEMMINA real-time, radio-frequency echo-signal equipment for testing novel investigation methods.

Fast echographic multiparameter multi-image novel apparatus (FEMMINA), is a hardware and software platform dedicated to ultrasonic signal and image processing. FEMMINA is able to operate with sequences of radiofrequency (RF) frames. Its architecture is designed to be modular, expandable, and aimed at implementing different ultrasonic investigation techniques. The first experimental characteristic of this system is in its capability to operate in real time with ultrasonic RF signals, starting from acquisition up to processing, storage, and visualization. The second characteristic is the user-system interactivity that allows one to modify the operation appropriately while observing results. Currently, FEMMINA works in both typical experimental situations to study novel investigation techniques and clinical field to validate the proposed methods in different human districts.

Biomedical Research↗

Subharmonic emissions from microbubbles: effect of the driving pulse shape.

The aims of this work are to investigate the response of the ultrasonic contrast agents (UCA) insonified by different arbitrary-shaped pulses at different acoustic pressures and concentration of the contrast agent focusing on subharmonic emission. A transmission setup was developed in order to insonify the contrast agent contained in a measurement chamber. The transmitted ultrasonic signals were generated by an arbitrary wave generator connected to a linear power amplifier able to drive a single-element transducer. The transmitted ultrasonic pulses that passed through the contrast agent-filled chamber were received by a second transducer or a hydrophone aligned with the first one. The radio frequency (RF) signals were acquired by fast echographic multiparameters multi-image novel apparatus (FEMMINA), which is an echographic platform able to acquire ultrasonic signals in a real-time modality. Three sets of ultrasonic signals were devised in order to evaluate subharmonic response of the contrast agent respect with sinusoidal burst signals used as reference pulses. A decreasing up to 30 dB in subharmonic response was detected for a Gaussian-shaped pulse; differences in subharmonic emission up to 21 dB were detected for a composite pulse (two-tone burst) for different acoustic pressures and concentrations. Results from this experimentation demonstrated that the transmitted pulse shape strongly affects subharmonic emission in spite of a second harmonic one. In particular, the smoothness of the initial portion of the shaped pulses can inhibit subharmonic generation from the contrast agents respect with a reference sinusoidal burst signal. It also was shown that subharmonic generation is influenced by the amplitude and the concentration of the contrast agent for each set of the shaped pulses. Subharmonic emissions that derive from a nonlinear mechanism involving nonlinear coupling among different oscillation modes are strongly affected by the shape of the ultrasonic driving pulse.

Contrast Media↗

ICARUS: imaging pulse compression algorithm through remapping of ultrasound.

In this work we tackle the problem of applying to echographic imaging those synthetic aperture focusing techniques (SAFT) in the frequency domain commonly used in the field of synthetic aperture radars (SAR). The aim of this research is to improve echographic image resolution by using chirp transmit signals, and by performing pulse compression in both dimensions (depth and lateral). The curved geometry present in the unfocused radio-frequency (RF) ultrasonic image is the main cause of inaccuracy in the direct application of frequency domain SAFT algorithms to echographic imaging. The focusing method proposed in this work, after pulse compression in the depth dimension, performs lateral focusing in the mixed depth-lateral spatial frequency domain by means of a depth variant remapping followed by lateral pulse compression. This technique has the advantage of providing a resolution that is uniform in nonfrequency selective attenuation media, and improved with respect to conventional time domain SAFT, without requiring the acquisition and processing of channel data necessary for the most advanced synthetic transmit aperture techniques. Therefore, the presented method is suitable for easy real-time implementation with current generation hardware.

Algorithms↗

Transient subharmonic and ultraharmonic acoustic emission during dissolution of free gas bubbles.

This work concerns the study of free gas bubble behavior, a basic step in contrast agent study. In order to improve the understanding of microbubble-ultrasound interaction, we propose an acoustic dynamic observation of microbubble behavior performed by a high frame-rate acquiring and processing system. Results from ultrasonic observations of free gas microbubbles are discussed and compared with theoretical simulation. Peculiar radio frequency (RF) echo signals back-propagated from bubbles during dissolution up to their destruction are shown and their behavior is discussed. In particular, the different orders of subharmonic emissions related to changes in bubble sizes during dissolution were observed.

Acoustics↗

A novel spectral ultrasonic differentiation method for marking regions of interest in biological tissue: in vitro results for prostate.

OBJECTIVE: The aim of the present study was to evaluate the effectiveness of a new method of spectral analysis of the radiofrequency (RF) ultrasonic echo signal in discriminating neoplastic from non-neoplastic tissue of the prostate gland. MATERIAL AND METHODS: The proposed method was previously set up on ten prostatic glands where cancer had been detected by histology in order to correlate the tumour areas with specific spectral parameters. In the present study sixty prostate specimens of patients undergoing radical retropubic prostatectomy for clinically localized prostate cancer were examined. The surgically removed prostate glands were scanned using an echo signal acquisition apparatus and the spectral parameters were obtained by the wavelet transform. The echographic scans of all cases were then compared with the whole-mount histological sections of the prostate in order to evaluate sensitivity and specificity of the proposed method. RESULTS: The sensitivity and specificity for cancer detection were 93% and 91%, respectively. The specificity was invalidated by the fact that in some of the cases studied, the tumour was located in areas of benign prostatic hyperplasia (BPH). As for the sensitivity, of the three false negative cases two were due to the coexistence of cancer foci and BPH. CONCLUSIONS: Our proposed method, named WAMBLE (Wavelet Analysis Multi Band Local Estimator), is accurate in detecting prostate cancer. Further in vivo studies are warranted to confirm the clinical value of this technique.

Diagnosis, Differential↗

Toward virtual biopsy through an all fiber optic ultrasonic miniaturized transducer: a proposal.

The present generation of devices based on opto-acoustic and acousto-optic conversion lets us foresee the possibility of realizing complete miniaturized transmitting-receiving transducers, able to generate and detect wideband ultrasounds by laser light. In the present paper, a miniaturized ultrasonic transducer entirely based on fiber optic technology is proposed. Such a device springs from the conjunction between our research, which has produced a highly efficient fiber optic opto-acoustic source, with the results obtained by other researchers concerning the realization of an ultrasonic receiver based on optical interferometry. Making use of the thermo-elastic effect for ultrasound generation, a source of ultrasound can be obtained by coupling a fiber optic to pulsed laser, if a film capable of absorbing laser light is placed onto fiber end. Starting from these remarks, we propose an efficient opto-acoustic source, able to generate pressure pulses with amplitude of the order of 10(4) Pa and bandwidth extending up to 40 MHz and beyond by using graphite materials as absorbing film. This solution makes use of a low-power pulsed laser as optical source possible. An ultrasonic receiving element was realized placing a Fabry-Perot cavity over the tip of a fiber optic. The cavity thickness modulation induced by ultrasonic beam is detected by an interferometer optical technique. We have realized a prototype of a receiving device that exhibits a sensitivity comparable with that of piezoelectric devices (10-100 nV/Pa) and an almost flat bandwidth extending up to 20 MHz or more. The extreme miniaturization of the resulting ultrasonic transducer, together with its wide ultrasonic frequency bandwidth, is the first step toward ultrasonic tissue biopsy. In this paper, before discussing the problem of constructing a complete ultrasonic transducer composed by a transmitter and receiver, the results carried out in these fields during the last decade are reviewed.

Biopsy↗

A Doppler system for dynamic vector velocity maps.

The aim of the vector Doppler technique is the quantitative reconstruction of a velocity field independently of the ultrasonic probe axis to flow angle. In particular, vector Doppler is interesting for studying vascular pathologies related to complex blood flows. A problem of vector Doppler is data representation in real-time that should be easy to interpret for the physician. In this work, we present a technique for dynamic display of vector velocity maps and some experimental results obtained in vitro with 2-D vector Doppler on flow phantoms reproducing complex flow conditions. An improvement in the map presentation was obtained by using velocity vector field interpolation. In this work, we considered the problem of spatial sampling for vector Doppler, establishing a relationship between sampling steps and scanning system characteristics. Finally, we developed a novel multimedia solution that uses both interpolated images and sound to discriminate between laminar and turbulent flows.

Blood Flow Velocity↗

Hardware and software platform for real-time processing and visualization of echographic radiofrequency signals.

In this paper the architecture of a hardware and software platform, for ultrasonic investigation is presented. The platform, used in conjunction with an analog front-end hardware for driving the ultrasonic transducers of any commercial echograph, having the radiofrequency echo signal access, make it possible to dispose of a powerful echographic system for experimenting any processing technique, also in a clinical environment in which real-time operation mode is an essential prerequisite. The platform transforms any echograph into a test-system for evaluating the diagnostic effectiveness of new investigation techniques. A particular user interface was designed in order to allow a real-time and simultaneous visualization of the results produced in the different stages of the chosen processing procedure. This is aimed at obtaining a better optimization of the processing algorithm. The most important platform aspect, which also constitutes the basic differentiation with respect to similar systems, is the direct processing of the radiofrequency echo signal, which is essential for a complete analysis of the particular ultrasound-media interaction phenomenon. The platform completely integrates the architecture of a personal computer (PC) giving rise to several benefits, such as the quick technological evolution in the PC field and an extreme degree of programmability for different applications. The PC also constitutes the user interface, as a flexible and intuitive visualization support, and performs some software signal processing, by custom algorithms and commercial libraries. The realized close synergy between hardware and software allows the acquisition and real-time processing of the echographic radiofrequency (RF) signal with fast data representation.

Computer Graphics↗