Search PubMed⌕ Search

Biomedical subjects

Leo G Carney

Publications and source records attributed to Leo G Carney.

14 recordsLinked to original sources

Visual performance after overnight orthokeratology.

PURPOSE: To investigate visual performance after overnight orthokeratology in terms of changes from baseline values, regression of the orthokeratology effect over time, and evaluation of the best-corrected vision after treatment. In particular, to evaluate any residual visual deficits over the duration of a day due to the abnormal corneal topography induced by orthokeratology treatment. METHOD: One eye of each of six subjects was fitted with custom designed BE orthokeratology lenses (Capricornia, Brisbane, Australia), with the fellow eye acting as a control. Unaided vision, subjective sphero-cylindrical refraction, high contrast high luminance visual acuity, low contrast high luminance visual acuity, high contrast low luminance visual acuity and letter contrast sensitivity were measured at baseline and after one night (Day 1) and eight nights (Day 8) of lens wear. Except for baseline, data were collected after overnight lens wear immediately after lens removal, and again 3, 6 and 9h after lens removal. At each time point throughout the day, the visual performance measures were evaluated with the initial refraction of the day (the 0h refraction) and also using the optimum subjective refraction at each measurement time. This method was used to evaluate the practical visual performance to be expected after orthokeratology treatment and the residual visual deficits arising from any induced corneal changes after correction of defocus. RESULTS: As expected, orthokeratology lens wear significantly changed unaided vision and refraction from baseline. However, it did not significantly affect visual acuity in different contrast conditions, or contrast sensitivity. The spherical component of refraction was the only parameter to exhibit regression over each day (p=0.021), with more stability demonstrated on Day 8 than Day 1 (p=0.012). There were no statistically significant changes of best-corrected acuity from baseline in the differing contrast and luminance conditions. CONCLUSION: Apart from the predicted improvements in unaided vision and reduction of the myopic refractive error, orthokeratology treatment was not found to significantly change any other aspects of visual acuity and contrast sensitivity. All visual performance measures exhibited stability over a 9-h period. Spherical refractive error changed significantly on Day 1 but became stable after a week of treatment. These results indicate that the corneal topography changes induced by orthokeratology do not induce changes in aberrations that are large enough to significantly diminish visual performance.

Circadian Rhythm↗

A review of astigmatism and its possible genesis.

Astigmatism is a refractive condition encountered commonly in clinical practice. This review presents an overview of research that has been carried out examining various aspects of this refractive error. We examine the components of astigmatism and the research into the prevalence and natural course of astigmatic refractive errors throughout life. The prevalence of astigmatism in various ethnic groups and diseases and syndromes is also discussed. We highlight the extensive investigations that have been conducted into the possible aetiology of astigmatism, however, no single model or theory of the development of astigmatism has been proven conclusively. Theories of the development of astigmatism based on genetics, extraocular muscle tension, visual feedback and eyelid pressure are considered. Observations and evidence from the literature supporting and contradicting these hypotheses are presented. Recent advances in technology such as wavefront sensors and videokeratoscopes have led to an increased understanding of ocular astigmatism and with continued improvements in technology, our knowledge of astigmatism and its genesis should continue to grow.

Age Factors↗

The influence of eyelid morphology on normal corneal shape.

PURPOSE: To investigate associations between the topography of the cornea and the morphology of the eyelids in a population of young adult subjects with a range of refractive errors. METHODS: Corneal topography data and digital images of the anterior eye were acquired for 100 young adult subjects. The corneal topography data and palpebral fissure images were analyzed to determine a range of parameters describing the shape of the cornea and the morphology of the palpebral fissure. Correlation analysis was carried out to investigate for significant associations between the parameters describing the topography of the cornea and the parameters describing the morphology of the palpebral fissure. RESULTS: A number of highly significant correlations were found between the best-fitting corneal spherocylinder and the eyelid morphology parameters. The corneal best-fit sphere (M) was significantly correlated with the horizontal palpebral fissure width (r = -0.428; P < 0.001). Corneal astigmatism power vector J45 was significantly correlated with the angle of the palpebral fissure (r = 0.392; P < 0.001). The axis of corneal astigmatism was also found to be significantly correlated with the angle of the palpebral fissure (r = 0.317; P = 0.005). CONCLUSIONS: A number of significant associations exist between the corneal spherocylinder and the morphology of the eyelids in a normal adult population.

Adolescent↗

The morphology of the palpebral fissure in different directions of vertical gaze.

PURPOSE: The purpose of this study is to investigate the normative morphology of the palpebral fissure by measuring a range of biometric eye dimensions for a population of young subjects through analysis of digital images in primary gaze and two typical angles of downward vertical gaze. Palpebral fissure characteristics are clinically important in areas such as contact lens practice. METHODS: High-resolution digital images were taken of 76 young subjects with a range of refractive errors in primary gaze and 20 degrees and 40 degrees downward gaze. The digital images were analyzed to ascertain a range of biometric measures of the palpebral fissure for each subject in each angle of gaze. Repeated-measures analysis of variance was used to investigate changes occurring in the palpebral fissure dimensions with vertical angle of gaze. RESULTS: Highly significant changes were found to occur in the horizontal and vertical palpebral fissure dimensions, the palpebral fissure angle, and the eyelid contour as a function of angle of gaze. The palpebral fissure narrows in the vertical dimension (from an average vertical palpebral aperture width for white subjects in primary gaze of 9.7+/-1.2 mm to an average width of 6.4+/-1.1 mm in 40 degrees downgaze), shortens in the horizontal dimension (from average horizontal palpebral aperture width of 27.1+/-1.5 mm in primary gaze to an average of 25.6+/-1.8 mm in 40 degrees downgaze), and becomes more "down-slanted" with increasing downward gaze. CONCLUSIONS: Highly significant changes to the palpebral fissure dimensions occur in downward vertical gaze. These changes are important because many visual tasks are performed in downward gaze. These findings have implications for the management of lid anomalies and for contact lens fitting and design.

Adolescent↗

The topography of the central and peripheral cornea.

PURPOSE: To investigate the topography of the central and peripheral cornea in a group of young adult subjects with a range of normal refractive errors. METHODS: Corneal topography data were acquired for 100 young adult subjects by a method that allows central and peripheral maps to be combined to produce one large, extended corneal topography map. This computer-based method involves matching the common topographical features in the overlapping maps. Corneal height, axial radius of curvature, and axial power data were analyzed. The corneal height data were also fit with Zernike polynomials. RESULTS: Conic fitting to the corneal height data revealed the average apical radius (Ro) was 7.77 +/- 0.2-mm and asphericity (Q) was -0.19 +/- 0.1 for a 6-mm corneal diameter. The conic fit parameters were both found to change significantly for increasing corneal diameters. For a 10-mm corneal diameter, Ro was 7.72 +/- 0.2 mm and Q was -0.36 +/- 0.1. A slight but significant meridional variation was found in Q, with the steepest principal corneal meridian found to flatten at a slightly greater rate than the flattest meridian. The RMS fit error for the conic section was found to increase markedly for larger corneal diameters. Higher-order polynomial fits were needed to fit the peripheral corneal data adequately. Analysis of the axial power data revealed highly significant changes occurring in the corneal best-fit spherocylinder with increasing distance from the corneal center. The peripheral cornea was found to become significantly flatter and to decrease slightly in its toricity. Individual subjects exhibited a range of different patterns of central and peripheral corneal topography. Several of the higher order corneal surface Zernike coefficients were found to change significantly with increasing corneal diameter. CONCLUSIONS: Highly significant changes occur in the shape of the cornea in the periphery. On average, the peripheral cornea becomes significantly flatter and slightly less astigmatic than the central cornea. A conic section is a poor estimator of the peripheral cornea.

Adolescent↗

The diurnal variation of corneal topography and aberrations.

PURPOSE: To investigate if diurnal variation occurs in corneal topography. METHODS: Seventeen young subjects had corneal topography measured 3 times a day (around 9 AM, 1 PM, and 5 PM) on 3 days of the week (Monday, Tuesday, and Friday). Corneal tangential and refractive power were analyzed. To investigate diurnal variation in corneal aberrations, the corneal height data were converted into corneal wavefront error and expressed as Zernike wavefront coefficients. RESULTS: A significant diurnal change in corneal tangential power maps was found in 15 of the 17 subjects. This change typically consisted of a horizontal band of distortion in the superior and, to a lesser extent, inferior cornea, increasing throughout the day. Corneal refractive power showed small but significant diurnal changes occurring in the best fit sphere. Corneal wavefront error analysis revealed significant diurnal changes occurring in astigmatism 90/180 degrees and astigmatism 45/135 degrees. Two higher-order aberrations, primary vertical coma and trefoil along 30 degrees, also showed significant diurnal change. The combination of these 2 aberrations represents a "wavelike" distortion increasing throughout the day and returning to baseline the next morning. CONCLUSION: We have shown that significant diurnal change occurs in certain corneal aberrations. The changes appear to be related to forces from the eyelids on the anterior cornea. These findings may have important implications for customized refractive corrections and refractive error development.

Adult↗

Near work induced wavefront aberrations in myopia.

We undertook a detailed analysis of the wavefront aberrations of the eyes of 20 young progressing myopes (mean age=22 years; mean spherical equivalent=-3.84 D, range -1.00 to -7.5 D) and twenty young age matched emmetropes (mean age=23 years; mean spherical equivalent=-0.00 D, range +0.25 to -0.25 D). A wavefront sensor was used to measure the ocular wavefront and a videokeratoscope was used to measure corneal topography. The corneal wavefront was subsequently calculated and the difference between the corneal and ocular wavefront was derived to give the internal wavefront component of the eye. Ocular and corneal wavefronts were measured before and after a 2-h reading task. At the baseline measurements, the myopes showed greater levels of some high order ocular wavefronts than the emmetropes. These differences between the groups became larger following 2 h of reading. Ocular higher order wavefront RMS was (baseline RMS: myopes=0.21 microm, emmetropes=0.16 microm, difference p=0.05 and after 2 h reading was RMS: myopes=0.27 microm, emmetropes=0.17 microm, difference p=0.02). The differences between the groups are primarily due to changes in the corneal wavefront associated with a narrower lid aperture during reading for the myopes. These differences are enhanced by longer periods spent reading, larger pupils and consequently low light levels. We suggest lid induced corneal changes caused by reading in downgaze provides a theoretical framework that could explain the known features of myopia development. The inherited characteristics of facial and lid anatomy would provide a mechanism for a genetic component in the genesis of myopia.

Adult↗

Relationship between goblet cell density and tear function tests.

AIM: The objective of this study was to find a relationship between goblet cell density (GCD) and other diagnostic tests of dry eye in a group of normal healthy Chinese subjects. The capability of using GCD as a tear function test was assessed. METHOD: A total of 42 optometry students with no contact lens wear history were recruited. Subjects were required to fill in a dry eye questionnaire. The non-invasive tear break-up time (NITBUT) of each subject was measured, followed by phenol red thread test (PRTT) and tear break-up time (TBUT) tests. Conjunctival epithelial cells from the inferior nasal bulbar conjunctiva were harvested by the impression cytology technique. The specimens collected were labelled and stained with PAS (Periodic Acid Schiff)-haematoxylin. The goblet cells and the conjunctival epithelial cells were counted under a light microscope of 100x magnification. Spearman's rho (rho) correlation test was used to analyse the relationship between GCD and the other tear function tests. RESULTS: With a probability level of 0.0051 (corrected for a cumulative familywise error rate of p = 0.05), GCD was found to have no correlation with NITBUT (rho = -0.193, p = 0.222), McMonnies Dry Eye Scores (MCDES) (rho = -0.052, p = 0.742), PRTT (rho = - 0.188, p = 0.234) and TBUT (rho = 0.246, p = 0.117). CONCLUSION: There was no correlation between GCD and MCDES, NITBUT, PRTT and TBUT. The GCD alone is not a useful diagnostic test for tear film instability in normal eyes although it is a good indicator in the diagnosis of ocular surface diseases.

Adult↗

Experience and training as determinants of grading reliability when assessing the severity of contact lens complications.

PURPOSE: A study was conducted to investigate the influence of experience and training on grading reliability when assessing the severity of contact lens complications. METHODS: Twenty-three optometry students who were unfamiliar with the use of grading scales each used the Efron Grading Tutor computer program to ascertain grading reliability at an 'initial' experimental session and a 'final' session 3 weeks later. Twelve subjects (the 'trained' group) were given a tutorial on grading techniques and were asked to complete two grading exercises between the initial and final sessions. The other 11 subjects (the 'untrained' group) received no such training between the two sessions. Differences in grading reliability between the initial and final grading sessions were evaluated. RESULTS: Grading reliability was superior (lower) for the combined subject cohort at the final session (mean +/- standard deviation 0.33 +/- 0.12) compared with the initial session (0.46 +/- 0.25) (p = 0.004). However, there was no difference in the improvement in grading reliability between the two groups. CONCLUSIONS: Grading reliability improves statistically with some experience, although perhaps not to a clinically meaningful extent. No added benefit can be derived from supplemental training.

Clinical Competence↗

Corneal topography and accommodation.

PURPOSE: To investigate whether there are significant changes in corneal topography during accommodation in normal corneas and corneas that are pathologically thinner due to keratoconus. METHODS: A videokeratoscope was modified to present an accommodation stimulus that was coaxial with the instrument's measurement axis. Six subjects with normal corneas and four subjects with keratoconus were studied. Eighteen videokeratoscope measurements of one eye of each subject were taken at 0 diopter (D) accommodation demand and six for both of 4 D and 9 D accommodation demand. The effects of ocular micromovements on multiple topography maps were minimized using software algorithms. Average maps for the 4 D and 9 D accommodation demands were calculated and subtracted from the average map of the 0-D accommodation demand. A t test was applied at each point location within the topography maps to analyze the statistical significance of change (p < 0.001) within the difference maps. RESULTS: In the initial analysis, we found that a number of the subjects showed significant changes in corneal topography as accommodation changed. However, further analysis showed a significant group mean excyclotorsion of the topography maps of 1.6 +/- 1.1 degrees (p < 0.03) for the 4-D stimulus and 2.0 +/- 1.3 degrees (p < 0.01) for the 9-D stimulus compared with the 0-D stimulus. When we accounted for the excyclotorsion, we did not find clear evidence of statistically significant changes in corneal topography as a result of accommodation, either for the normal corneas or the keratoconic corneas. CONCLUSIONS: It appears unlikely that changes occur in central corneal shape during accommodation up to a level of 9 D in normal or keratoconic corneas. A small ocular excyclotorsion typically accompanies accommodation, and this changes the relative orientation of the topography of the cornea. This has significant implications for the interpretation of the optical characteristics of eyes during near viewing conditions.

Accommodation, Ocular↗

Corneal shape in hyperopia.

Background: A trend towards decreased peripheral corneal flattening with increasing myopia has recently been demonstrated. The present study was conducted to determine whether corneal asphericity also varies significantly with hyperopic refractive error. Methods: Thirty-five eyes with spherical equivalent refractive error ranging from -0.37 D to +6.00 D were examined. A conicoid equation was fitted to videokeratoscopic (Topographic Modeling System) data and corneal asphericity and apical radius of curvature values were calculated for each subject. Axial length measurements were made using a hand-held biometric ruler. Keratometry was also performed on each eye. Results: The relationship between corneal asphericity (Q) and spherical equivalent refractive error was not statistically significant (p = 0.7419). In addition, no association could be demonstrated between Q and corneal radius of curvature or between Q and axial length. Corneal radius of curvature was positively correlated with axial length (r = 0.367, p = 0.0298). Axial length was found to decrease as hyperopic refractive error increased (r = 0.753, p = 0.0001). Conclusions: For hyperopic eyes, corneal asphericity does not appear to be significantly correlated with refractive error, a finding that is at variance with previous data for myopic eyes showing an association between these two variables. The results suggest that there may be differences between hyperopic and myopic eyes with regard to the anterior segment changes that occur during refractive error development.

Journal Article↗

Monochromatic aberrations and characteristics of retinal image quality.

BACKGROUND: Patients use a wide variety of terms to describe the characteristics of their vision. These descriptions encompass the effects of their eyes' monochromatic aberrations. METHODS: To illustrate the effect of monochromatic aberrations on the quality of the retinal image, we mathematically reconstructed the image falling on the retina. This has been achieved by combining the properties of various scenes with the optical characteristics of the eye. RESULTS: The effects of some common monochromatic aberrations are illustrated. We also show examples of the retinal image characteristics for two eyes, one with a decentred corneal apex and a second with a decentred refractive surgery ablation. CONCLUSIONS: The image reconstruction technique provides a powerful tool for investigating the quality of the retinal image. It provides the capacity for clinicians to better understand a patient's visual performance. The image reconstruction technique can also broaden our knowledge of the effects of various forms of aberrations on retinal image quality for complex real-world scenes.

Journal Article↗