Search PubMed⌕ Search

Biomedical subjects

Latif Elci

Publications and source records attributed to Latif Elci.

9 recordsLinked to original sources

Solid phase extraction of gold(III) on Amberlite XAD-2000 prior to its flame atomic absorption spectrometric determination.

A solid phase extraction method for the determination of gold(III) at trace levels by flame atomic absorption spectrometer (FAAS) was developed. The method was based on retention of gold as chloro complexes through the Amberlite XAD-2000. The effect of some analytical parameters including hydrochloric acid concentration, sample volume, sample and eluent flow rates, eluent volume, eluent concentration and interfering ions on the recovery of gold(III) was investigated. The retention of gold(III) from 1.5 mol l(-1) HCl solution and the recovery of gold with 0.07 mol l(-1) NH3 solution were quantitative (>or=95%). The relative standard deviation (RSD) was calculated as 3.2% (n = 10). The detection limit for gold was 2 microg l(-1). The accuracy was checked with the determination of gold spiked an artificial seawater and a pure copper samples.

Adsorption↗

Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS).

A new method using a column packed with Amberlite XAD-2010 resin as a solid-phase extractant has been developed for the multi-element preconcentration of Mn(II), Co(II), Ni(II), Cu(II), Cd(II), and Pb(II) ions based on their complex formation with the sodium diethyldithiocarbamate (Na-DDTC) prior to flame atomic absorption spectrometric (FAAS) determinations. Metal complexes sorbed on the resin were eluted by 1 mol L(-1) HNO3 in acetone. Effects of the analytical conditions over the preconcentration yields of the metal ions, such as pH, quantity of Na-DDTC, eluent type, sample volume and flow rate, foreign ions etc. have been investigated. The limits of detection (LOD) of the analytes were found in the range 0.08-0.26 microg L(-1). The method was validated by analyzing three certified reference materials. The method has been applied for the determination of trace elements in some environmental samples.

Acetone↗

A multi-element solid-phase extraction method for trace metals determination in environmental samples on Amberlite XAD-2000.

A method for the preconcentration of some transition elements at trace level was proposed using a column filled with Amberlite XAD-2000 resin. Metal ions were adsorbed on XAD-2000 as their diethyldithiocarbamate chelates, then analytes retained on the resin were eluted by 1 mol L(-1) nitric acid in acetone and determined by flame atomic absorption spectrometry (FAAS). The influences of some analytical parameters including pH of sample solution, ligand amount, the type, concentration and volume of elution solution, flow rates of the sample and eluent solutions, adsorption capacity of the resin and sample volume on the preconcentration efficiency have been investigated. The influences of some matrix elements were also examined. The detection limit (N=20, 3 sigma) for Mn(II), Fe(II), Co(II), Cu(II), Cd(II), Zn(II), Pb(II) and Ni(II) were found as 0.20, 0.35, 0.25, 0.20, 0.20, 0.15, 0.45 and 0.25 microg L(-1), respectively. The validation of the procedure was carried out by analysis of certified reference materials. The proposed method was applied to natural waters and kale vegetable (Brassica oleracea var. acephala).

Brassica↗

Preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions in environmental samples by membrane filtration prior to their flame atomic absorption spectrometric determinations.

A method for separation-preconcentration of Pb(II), Cr(III), Cu(II), Ni(II) and Cd(II) ions by membrane filtration has been described. The method based on the collection of analyte metal ions on a cellulose nitrate membrane filter and determination of analytes by flame atomic absorption spectrometry (FAAS). The method was optimized for several parameters including of pH, matrix effects and sample volume. The recoveries of analytes were generally in the range of 93-100%. The detection limits by 3 sigma for analyte ions were 0.02microgL(-1) for Pb(II), 0.3microgL(-1) for Cr(III), 3.1microgL(-1) for Cu(II), 7.8microgL(-1) for Ni(II) and 0.9microgL(-1) for Cd(II). The proposed method was applied to the determination of lead, chromium, copper, nickel and cadmium in tap waters and RM 8704 Buffalo River Sediment standard reference material with satisfactory results. The relative standard deviations of the determinations were below 10%.

Cadmium↗

Membrane filtration - atomic absorption spectrometry combination for copper, cobalt, cadmium, lead and chromium in environmental samples.

Cellulose nitrate membrane filter was used for the preconcentration-separation of Cu, Co, Cd, Pb and Cr ions. The analyte ions were collected on the membrane filter by the aid of carmine. Then membrane filter was dissolved by using nitric acid. The levels of the analytes in the final solutions were determined by flame atomic absorption spectrometry (FAAS). The analytical parameters including pH, amounts of carmine, sample volumes etc. have been optimized. No influences have been observed from the matrix ions. The detection limits for analytes were in the range of 0.08 microg/l-0.93 microg/l. The validation of the procedure was checked by the analysis of standard reference sediment (GBW 07309). The present method has been successfully applied for the FAAS determinations of analyte ions in real samples including black tea and magnesium salts.

Collodion↗

Trace metal pollution from traffic in Denizli-Turkey during dry season.

OBJECTIVE: To determine the metal contents of date palm (Pheonix dactylifera) samples in dry season from Denizli-Turkey for investigation of heavy metal-polluted traffic. METHOD: The levels of iron, copper, zinc, lead, cadmium, nickel, chromium, and manganese ions in the leaves of thirty five date palm (Pheonix dactylifera) samples collected from various levels of traffic in the streets of Denizli-Turkey were determined by graphite furnace or flame atomic absorption spectrometry. The wet, dry, and microwave digestion procedures for the date palm (Pheonix dactylifera) leaves were compared. The accuracy of the digestion procedures was checked using a standard reference material (IAEA-336 Lichen, SRM). RESULTS: Microwave digestion procedure for the leaves was preferred because it was more proper with respect to both time and recovery than dry and wet digestion. The levels of the heavy metal ions investigated were the highest on the samples from high traffic level. Also correlations between metal levels and traffic volume for all the metals were investigated. CONCLUSION: In the light of our findings, the date palm (Phoenix dactylifera) leaves are suitable as a biomonitor for atmospheric heavy metal-polluted traffic. Significant correlations can be obtained between traffic levels and heavy metal concentrations.

Air Pollutants↗

Using of atomic absorption spectrometry for diagnosis of electrical injuries (an experimental rat study).

The diagnosis of electrical injuries may be difficult and sometimes we should use some methods to support that. In this experimental rat study; electrical injuries were made in the dorsal skin of rats using 110 V, 100 A ac current. Swabs were taken from these injuries and investigated for iron and copper by using atomic absorption spectrometry. There was a great significance between study and control groups for copper (p<0.01). It was suggested that metallic deposition to skin in electrical injuries can be shown by atomic absorption spectrometry as quantitatively and can be used for improving the diagnostic sensitivity of electrical lesions.

Animals↗

Separation of gold, palladium and platinum from metallurgical samples using an amberlite XAD-7 resin column prior to their atomic absorption spectrometric determinations.

A simple and sensitive method for the separation and preconcentration of gold, palladium and platinum has been established prior to their atomic absorption spectrometric determinations. Analytes from 0.5 mol dm(-3) KI in a 2 mol dm(-3) HCl solution were recovered using an Amberlite XAD-7 column as halogeno complexes. The effects of some analytical parameters, including reagent amounts, sample volume and flow rates, on the quantitative recoveries of gold, palladium and platinum were investigated. The influences of some diverse ions were also studied. The proposed method has been applied for the preconcentration and separation of analytes from pure copper and anodic slime samples with satisfactory results (recoveries > 95%, relative standard deviations < 9.0%, relative error < or = 5%).

Journal Article↗

Speciation of antimony using chromosorb 102 resin as a retention medium.

The selective retention of the Sb(III) chelate with ammonium pyrrolidine dithiocarbamate (APDC) on a column of Chromosorb 102 resin from a buffered sample solution including Sb(V) was used for the determination of Sb(III). The retained antimony was eluted with acetone. The retention of the Sb(III)-iodide compounds with sodium iodide on the Chromosorb 102 resin column from the same solution after reducing Sb(V) to Sb(III) by iodide in acidic solution was used to preconcentrate the total antimony. The retained antimony was eluted with 0.25 mol l(-1) HNO3. The antimony in the effluent was determined by flame atomic-absorption spectrometry. Also, the total antimony was determined directly by graphite-furnace atomic absorption spectrometry. The Sb(V) concentration could be calculated by the difference. The recoveries were > or = 95%. The detection limits of a combination of the column procedure and flame AAS for antimony were 6 - 61 microg l(-1) and comparable to 4 microg l(-1) for a direct GFAAS measurement. The relative standard deviations were <6%. The procedure was applied to the determination of Sb(III) and Sb(V) in spiked tap water, waste-water samples and a certified copper metal with the satisfactory results.

Antimony↗