Search PubMed⌕ Search

Biomedical subjects

Lars Friberg

Publications and source records attributed to Lars Friberg.

5 recordsLinked to original sources

Clinical impact of diagnostic SPET investigations with a dopamine re-uptake ligand.

The diagnosis of Parkinson's disease is based on clinical features with pathological verification. However, autopsy has been found to confirm a specialist diagnosis in only about 75% of cases. Especially early in the course of the disease, the clinical diagnosis can be difficult. Imaging of presynaptic dopamine transporters (DAT receptors) has provided a possible diagnostic probe in the evaluation of Parkinson's disease. The cocaine analogue [(123)I]-2-beta-carboxymethoxy-3-beta(4-iodophenyl)tropane ([(123)I]-beta-CIT) is one of several radioligands that have been developed for single-photon emission tomography (SPET). The purpose of this study was to evaluate the impact of [(123)I]-beta-CIT SPET on the diagnosis and clinical management of patients with a primary, tentative diagnosis of parkinsonism. We undertook a retrospective evaluation of the clinical records of 90 consecutive patients referred to [(123)I]-beta-CIT SPET from the neurological department, Bispebjerg Hospital. In 58 subjects the scans revealed altered tracer uptake consistent with Parkinson's disease, progressive supranuclear palsy and multiple system atrophy. A significant change in the management or treatment because of the scan was found in 25 patients (28%). The sensitivity of the examination was 97% and the specificity 83%. In conclusion, a significant clinical impact of DAT receptor SPET imaging was found. DAT receptor imaging is a useful diagnostic probe in patients with a possible diagnosis of parkinsonism.

Adult↗

Simultaneous cardiac output and regional myocardial perfusion determination with PET and nitrogen 13 ammonia.

BACKGROUND: The purpose of this study was to evaluate the possibility of measuring cardiac output during positron emission tomography (PET) examination of myocardial perfusion with nitrogen 13 ammonia. METHODS AND RESULTS: In 7 patients undergoing right-sided cardiac catheterization for evaluation of heart failure and 6 patients who had undergone heart transplantation, a thermodilution catheter for continuous measurement of cardiac output was inserted. An N-13 ammonia scan of the heart was subsequently performed, and with use of factor analysis, the time-activity curve from the right ventricle was derived from the dynamic image sequence. The PET-derived cardiac output was subsequently obtained according to the Stewart-Hamilton principle as the amount of injected tracer divided by the area under the time-activity curve. PET-acquired cardiac output measurements correlated closely with the invasively determined values for a wide range of cardiac output values (P < .0001). The mean difference was 0.12 L/min, with an SD of 0.74 L/min. The interobserver variation was low, with a mean difference of 0.06 L/min and an SD of 0.46 L/min. CONCLUSIONS: Cardiac output determination with N-13 ammonia and PET appears to be both accurate and precise and can be performed simultaneously with measurement of myocardial perfusion.

Adult↗

Instrumental investigations in primary headache. An updated review and new perspectives.

While some instrumental techniques are clearly useful for differentiating symptomatic forms from primary headache, the usefulness of certain other techniques, neurophysiological investigations in particular, in clinical practice is still debated. A Task Force of the European Federation of Neurological Societies has recently proposed guidelines and recommendations on the use of neurophysiological tests and neuroimaging procedures in non-acute headache. This article reviews many of the most important literature references relevant to this topic and looks at the prospects for future research.

Blinking↗