Search PubMed⌕ Search

Biomedical subjects

L Zamorano

Publications and source records attributed to L Zamorano.

At least 37 records · Page 2Linked to original sources

Interactive intraoperative localization during the resection of intraventricular lesions.

Mass lesions located in the ventricular system can be surgically challenging. These tumors are often slow growing and reach considerable size before they are diagnosed. These lesions commonly cause multiple obstructions to the circulation of cerebrospinal fluid with subsequent hydrocephalus. They are deeply located in the brain, surrounded by vital neurological and vascular structures, and often have irregular configurations. All these characteristics may pose real problems during surgery in terms of orientation and a optimal resection. For the surgical approach to such intraventricular lesions we are currently using an infrared-based system implemented at Wayne State University that allows intraoperative real-time localization. Three infrared cameras continuously track the position of multiple light-emitting diodes in relation to a predetermined "rigid body". This system can be used with different surgical instruments, and does not interfere with standard neurosurgical techniques. We present our preliminary experience in 18 patients with intraventricular tumors that were operated on between December 1992 and March 1995. Their lesions were located in the lateral ventricles, third ventricle, and pineal region with extension into the posterior aspect of the third ventricle. The use of the interactive infrared-based localizing unit allowed a total resection in 15 cases and a subtotal resection in 3 cases. We report 3 complications, but only one of them was related to the surgical procedure. The postoperative follow-up period ranged from 2 to 24 months. All patients were followed clinically and with postoperative magnetic resonance imaging scans. This interactive infrared system has proven to be a very useful tool, flexible, safe and reliable, increasing surgical efficiency, without a significant increase in the length of resection.

Adolescent↗

Image-guided computer-assisted spine surgery: a pilot study on pedicle screw fixation.

As the pedicle offers a strong point of attachment to the spine, several instrumentation systems using screws that go through the pedicle into the vertebral body have been developed to provide internal stability. All pedicle screw systems share the risk of damage to adjacent neural structures as a result of improper screw placement. A computer-assisted system allowing precise preoperative planning and real-time intraoperative interactive image localization has been implemented for spine instrumentation to optimize transpedicular spine fixation. A validation study was performed in an in vitro set-up drilling 20 pedicle pilot holes in lumbar vertebrae. An analysis in 77 histological cuts showed an ideal location in 70 with no case of injury to the pedicle cortex. We discuss initial clinical experience on cases of posterior lumbar stabilization. Interactive computer-assisted spine surgery provides an accurate and safe approach for transpedicular screw fixation and may provide a useful tool for optimization of spine surgery.

Bone Screws↗

Vascular malformations of the brain. Surgical management using interactive image guidance.

This article describes the use of interactive image guidance in the surgical management of vascular malformations (VMs). Indications include VMs located in or around eloquent brain regions such as speech and motor sensory areas. The image guidance provides a three-dimensional view of the actual vascular malformations through computer simulation and an accurate means of determining its position in relation to adjacent brain structures (anatomic localization).

Adolescent↗

Computer-aided fixation of spinal implants.

Medical imaging provides an important basis for modern diagnosis as well as for preoperative planning of surgical procedures. However, information gained cannot be transferred directly into the operating room. Furthermore, the safety and accuracy of the surgical intervention would be improved by interactive navigation of surgical instruments. These features are provided by the system for computer-aided fixation of spinal implants described in this paper.

Computer Simulation↗

Clinical evaluation of a system for precision enhancement in spine surgery.

Most techniques in segmental spinal fixation surgery rely on the identification of predefined targets with the help of anatomical landmarks and on intraoperative use of image intensifiers. However, because there is no direct link between the image information, the accessible spinal anatomy, and the action of surgical instruments several potential problems and possible complications are still involved. A novel system for spinal surgery has been designed allowing for the real-time, intraoperative localization of surgical instruments in medical images. In practice this was achieved by combining image-guided stereotaxis with advanced optoelectronic position sensing techniques. Modules were developed for image data processing, surgical planning and simulation, and various intraoperative procedures. A detailed validation of the system was performed indicating an overall accuracy to be better than the slice distance of the spinal image used. In an in-vitro setting 20 pilot holes for pedicle screws were prepared in human cadaveric lumbar spines. An analysis in 77 histological cuts showed an ideal location in 70 and only minor cortex engagement in seven sections. In vivo the system has been successfully applied in three posterior low lumbar stabilizations with overall 15 transpedicular screws. RELEVANCE--:This article focuses on the clinical evaluation of a computer-assisted surgery system and its application to the operating theatre for transpedicular fixation of the spine. The given approach effectively keeps the surgeon 'in the loop' and requires only minor modifications of the established surgical techniques and associated instruments. The results of this study indicate that advanced computer-assisted techniques may significantly improve the accuracy and safety of surgical interventions of the spine. The proposed technique may in future be adapted to other applications in orthopaedic surgery.

Journal Article↗

Permanent iodine-125 implants in the up-front treatment of malignant gliomas.

Between July 1989 and July 1992, 58 patients with newly diagnosed, histologically confirmed malignant gliomas (40 anaplastic astrocytomas, 18 glioblastoma multiforme) underwent implantation with low-activity iodine-125 sources. Patients were considered appropriate candidates for brachytherapy if their Karnofsky scores were > or = 70 and their contrast-enhancing tumors were < 6 cm in maximum diameter. Tumor volumes ranged from 0.1 to 90 ml. Ten patients had implants only. The other 48 patients received additional external beam radiation; 38 patients received radiation 1 to 2 weeks after the implant, and 10 patients received radiation preceding the implant. Median survival has not been reached but is currently greater than 31 months for patients with anaplastic astrocytoma and greater than 23 months for patients with glioblastoma. The rate of second operation for this group of patients was 45% (26 patients). Brain necrosis requiring resection occurred in 11 patients (19%). Although further follow-up is required, we conclude that low-activity permanent iodine-125 implants provide patients who have newly diagnosed malignant gliomas long-term survival with an acceptable risk of late complications.

Adolescent↗

Endoscopic stereotactic interventions in the treatment of brain lesions.

Image-guided stereotaxis is an accurate and safe method of directing therapy to target volumes defined in two-dimensional (2D) multiplanes or three-dimensional (3D) perspectives using computer reconstruction of image data. The major limitations of stereotactic techniques are a lack of intraoperative visualization and direct monitoring of the procedures, and changes of intracranial coordinates after decompression of cystic lesions or aspiration of cerebrospinal fluid in the management of intraventricular lesions. Endoscopic laser stereotaxis (ELS) involves integration of rigid-flexible endoscopy and Nd-YAG laser to 3D-2D multiplanar image-guided stereotactic procedures. The major advantages of ELS include: minimally invasive (burrhole or small craniotomy surgery), direct intraoperative visualization, hemostasis, evacuation or resection assessment, and wide exploration of intracranial cavities or ventricles. ELS has been used in the management of 152 clinical cases including biopsy, aspiration, resection and internal decompression of deep and subcortical intracranial lesions, and different types of fenestration procedures. Image-guidance combined with endoscopic techniques may offer a safe, accurate alternative to conventional neurosurgical procedures in treating small solid, cystic, and intraventricular lesions as well as fenestration procedures.

Biopsy↗

Zamorano-Dujovny multipurpose neurosurgical image-guided localizing unit: experience in 866 consecutive cases of 'open stereotaxis'.

We describe the Zamorano-Dujovny localizing unit which consists of a ring-shaped headholder held on the patient's head by three or four variably placed fixation pins, thereby avoiding interference with the flap sites or craniotomy. The base ring is mounted intraoperatively on a special adapter that allows any patient positioning including supine, lateral prone, 3/4 prone, sitting, etc. Imaging studies, such as computed tomography, magnetic resonance imaging, x-ray, digital angiography, and digital subtraction angiography can be performed with the headholder anchored in place for multimodality image localization. Surgical draping can be done over the ring to provide a completely sterile field. An arc/quadrant localizing device can be mounted on any four alternative positions according to the neurosurgeon's preference. PC-compatible software gives the setting for any possible mounting. Intraoperatively the localizing unit can be used in a 'fixed' permanent setting or as a 'nonfixed' system to provide intraoperative three-dimensional orientation. Different types of instruments compatible with the unit extend its capabilities, such as 'bayonet'-type brain retractors (cylinders and speculum) that keeps the surgical corridor unobstructed from the arc. As an alternative, in the nonfixed setting, self-retaining arms are fixed to the base ring and brain retractors and conventional microsurgical techniques can be used without any mechanical obstruction.

Angiography, Digital Subtraction↗

Stereotactic endoscopic interventions in cystic and intraventricular brain lesions.

Image guided stereotaxis is an accurate and safe method of directing therapy to target volumes defined in two-dimensional (2D) multiplanes or three-dimensional (3D) perspectives using computer reconstruction of image data. The major limitations of stereotactic techniques are related to a lack of intraoperative visualization and direct monitoring of the procedures and to changes of intracranial coordinates after decompression of cystic lesions or aspiration of cerebrospinal fluid in the management of intraventricular lesions. Endoscopic laser stereotaxis (ELS) involves integration of rigid-flexible endoscopy and Nd-YAG laser to 3D-2D multiplanar image-guided stereotactic procedures. The major advantages of ELS include: direct intraoperative visualization, hemostasis, evacuation or resection assessment, and wide exploration of intracranial cavities or ventricles. The technique allows safe aspiration, biopsy, and resection or internal decompression of deep and subcortical intracranial lesions. ELS has proved to be safe and effective in the management of 76 clinical cases and appears to be a promising technique in the management of cystic and intraventricular lesions.

Brain Diseases↗

Computer-assisted neurosurgery: simulation and automation.

Instrumentation has been developed to automate, accurately guide, and integrate microsurgery laser resection equipment that is used in stereotactic brain surgery. The instrument is a computer-controlled laser-guiding system. The improvement in the accuracy comes from relying on a certain well-referenced three-dimensional surgical orientation, and computer-preplanned tumor contours, rather than only the surgeons hand-eye orientation in the operating room.

Automation↗

Stereotactic management of midline brain lesions.

Eighty-seven patients, aged 10 months to 92 years, with midline brain lesions were treated using stereotactic techniques at our institution between January 1987 and June 1990. A total of 119 stereotactic procedures were performed with no operative mortality. Procedures included 53 biopsies only, 22 endoscopic laser decompressions, 8 stereotactic microsurgical resections, 9 permanent implants of 125I, 12 temporary implants of 125I, 11 cyst aspirations, 2 cystoperitoneal shunts and 2 intracavitary 32P. The morbidity rate was 4.21%. Local anesthesia was used in 106 of the procedures (89%). Accurate diagnosis was achieved in all cases. Image guidance and stereotactic techniques open new frontiers in the diagnostic and therapeutic management of deep-seated midline intraparenchymal lesions.

Biopsy↗

Permanent iodine-125 implant and external beam radiation therapy for the treatment of malignant brain tumors.

Survival data of 114 patients treated for malignant brain tumors with 125I interstitial radiation therapy at Henry Ford Hospital, Detroit, Mich. (1986-1990), are presented. The first 64 patients were treated with temporary 125I implants with a total prescribed dose of 60 Gy at a dose rate of 40 cGy/h. In order to reduce the risk of injury to the surrounding normal tissue associated with high-dose brachytherapy, a new approach was initiated using permanent implants with a lower dose rate; 50 patients were treated after surgical resection with permanent implantation of 125I seeds at a lower dose rate of 4-7 cGy/h, with a total dose of 10,000-12,000 cGy, and concurrent external radiation therapy of 5,000 cGy. The rationale of this protocol was to increase the effectiveness of the low-dose-rate implant by a concurrent 'daily' boost of external radiation, thus inhibiting the proliferation of tumor cells during the protracted low-dose radiation treatment. Survival was compared between groups with permanent and temporary implants in terms of effectiveness in tumor control as well as impact on clinical condition. Low-dose-rate implant with concurrent external radiation therapy seems to offer the best chance for long-term survival without deterioration in the clinical condition.

Adult↗

In vivo and in vitro study of the lesions produced with a computerized radiofrequency system.

For many years, radiofrequency-generated lesions have been used for the treatment of pain and abnormal movements. However, the reliability of this method has been questioned because of the variation in the size of lesions produced by the electrode at different times and temperatures. A 500-kHz radiofrequency generator with different electrodes was used to determine the size of lesions, using different time and temperature exposures. A computerized feedback mechanism kept the tip temperature constant during the production of the lesion, regardless of varying tissue impedance. Eight electrodes of different size and tip characteristics were evaluated at different temperatures and time settings, both in vitro and in vivo. Graphic display of the curves in time were obtained at 65, 70, 75, 80, 85 and 90 degrees C. The effects of thermo-coagulation were studied in vitro in fresh egg whites, using time intervals of 20, 40, 60, 80 and 100 s, and in vivo, in the subcortical white matter of 20 adult New Zealand white rabbits. Animals were sacrificed after 7 days. Lesions were photographed and measured under magnification. In all cases, the coagulated masses were ellipsoid, with regular, well-demarcated borders. A two-way statistical analysis of variance was done. The coagulum size increased with higher temperatures and with larger probes. The increase was significant in both diameter and length (p = 0.001). In contrast, the use of different times at the same level of temperature showed no significant increase in most of the electrodes. There were two statistical significant time effects, for both diameter and length, with the monopolar 2-mm electrode. The use of real-time monitoring with graphic display and the feedback information provided for the computerized control of power and current allows high precision of the temperature at the electrode tip during the production of the lesion.

Analysis of Variance↗

Application of multimodality imaging stereotactic localization in the surgical management of vascular lesions.

Multidimensional image preplanning and accurate pre and intraoperative localization for intracranial vascular lesions have been implemented. Methodology include carbon fiber base ring, localizer plates, any X-ray tubes, PC compatible software and intraoperative localizing unit. Surgical management of deep arteriovenous malformations is especially suitable for this technique, including the use of intraoperative digital angiography.

Cerebrovascular Disorders↗

The anterior cavernous sinus space.

The anterior cavernous sinus space is the venous space anterior to the cavernous carotid artery. It is tetrahedral in shape with the anterior apex at the superior orbital fissure. The superomedial wall is formed by the base of the anterior clinoid process. The inferomedial wall is formed by the sphenoid bone. The lateral wall consists of two layers of dura with the oculomotor, trochlear, ophthalmic and abducens nerves in the inner layer. Medially, the posterior wall consists of the cavernous carotid artery. Laterally, it communicates with the lateral cavernous sinus space. Paraclinoid and carotid cave aneurysms may occupy this space and its microanatomy is important in the surgery of these aneurysms.

Carotid Arteries↗

Image-guided stereotactic centered craniotomy and laser resection of solid intracranial lesions.

A technique in which solid intracranial lesions are removed using computerized image processing under stereotactic conditions is described. A specially developed carbon fiber ring holder compatible with most image studies is used as a reference system. Intraoperatively it affords freedom of patient positioning and unobstructed access to any site of the head. Four position alternatives of the aiming device allow the removal of lesions from any location. For superficial lesions located near eloquent areas, a 'centered' craniotomy is performed, usually under local anesthesia, and removal is performed using loupe magnification, bipolar coagulation ultrasonic aspiration of the Nd:YAG laser fiber in the contact or noncontact technique. In deep-seated lesions, a surgical 'corridor' is established and kept by means of retractors adapted for use with the stereotactic apparatus. Microsurgical techniques and the CO2 laser are used in solid lesions; in vascular lesions, bipolar coagulation or the ND:YAG laser can be used. Centered craniotomy allows the precise localization, enhancement, three-dimensional orientation and removal of lesions with minimal trauma to the surrounding brain. The technique has been applied in 78 cases where the extreme accuracy of the technique, benign postoperative course and short hospitalization have been impressive.

Angiography, Digital Subtraction↗

Tumour recurrence vs radionecrosis: an indication for multitrajectory serial stereotactic biopsies.

External RT has been proved to be an important adjuvant to surgery in the treatment of malignant glioma. It has also been demonstrated, that its effect on survival is dose-dependent, although accompanied by a higher morbidity. Intents to localize the field of high dose RT to the tumour area have been performed with the aim to spare damage of the normal brain tissue. Between August 1983 to December 1987, 40 patients with malignant astrocytoma (16 GM, 24 AA) underwent high dose localized hyperfractionated external RT after surgical resection. Patients received 57.6 Gy to the tumour and oedema area associated with a boost localized to the tumour of 7.4, 14.4 or 24 Gy. In the follow-up, 16 patients died with evidence of increase in size of lesion diagnosed by CT/MRI. Since July 1987, 12 patients with recurrence or increase on size of CT/MRI lesion have undergone multitrajectory serial stereotactic biopsies. From the biopsies 8 patients were histologically diagnosed was compatible with radionecrosis. From the 4 recurrences, 2 patients were treated with 125I implants and 1 with new resection. Patients with radionecrosis were treated with corticoides and diuretics, obtaining partial or complete remission of symptoms and decrease in size of CT lesion. Undoubtly, Multiplanar/3D multitrajectory serial stereotactic biopsies play a major role in the follow-up of these patients, and accurate diagnosis need to be established for further treatment therapy. The question remains if these localized boost should be replaced by 3D Multiplanar stereotactic interstitial radiotherapy boost after surgery and conventional radiotherapy.

Astrocytoma↗

Transposition of image-defined trajectories into arc-quadrant centered stereotactic systems.

A methodology and computer program used for transposition of image-defined trajectories into stereotactic space is presented. Arc-quadrant centered stereotactic frames (Leksell, modified by us Komai) are based on the principle of aiming a target point from any entry of a formed sphere of known radius. Frames adapted isocentrically to CT gantry and parallel to the scanning plane allow interactive selection of targets and trajectories based on multiplanar reformatted images. The mathematical fundaments to calculate angle A in the coronal plane and angle B in the saggital plane based on the geometrical configuration of arc-quadrant centered stereotactic devices are presented.

Brain Diseases↗