Long-term multicenter experience with a second-generation implantable pacemaker-defibrillator in patients with malignant ventricular tachyarrhythmias. The Guardian Multicenter Investigators Group.

A second-generation implantable pacemaker-cardioverter-defibrillator was evaluated in 200 patients with sustained ventricular tachycardia, ventricular fibrillation or prior cardiac arrest. The device permits demand ventricular pacing for bradyarrhythmias and for long QT interval or tachycardia suppression, uses programmable (3 to 30 J) energy shocks for conversion of ventricular tachycardia and ventricular fibrillation and is used with conventional pacing and defibrillation leads. Ventricular tachycardia/fibrillation recognition is based on the ventricular electrogram rate and requires reconfirmation before shock delivery. Two hundred patients (mean age 62 years, mean left ventricular ejection fraction 36%) were enrolled and followed up for 0 to 23 months (mean 12). Epicardial lead system implantation was performed with use of an anterolateral thoracotomy (38%), median sternotomy (26%) and subxiphoid (20%) or subcostal (16%) approach. Perioperative mortality rate was 5.5% (all nonarrhythmic deaths). Implant defibrillation threshold ranged from 3 to 30 J (mean 15), with initial programmed shock energy ranging from 3 to 30 J (mean 22). Ventricular tachycardia/fibrillation sensing threshold ranged from 0.7 to 1.8 mV (median 1) and the tachycardia detection interval from 288 to 416 ms (median 320). Reprogramming of implant variables was necessary for reliable electrographic sensing (54 patients), programmed shock therapy (61 patients) and tachycardia detection rate (63 patients). Device activation for potential shock delivery occurred in 111 patients (55.5%) with actual shock delivery after ventricular tachycardia/fibrillation reconfirmation in 66 patients (33%). During follow-up study, there was a 1% arrhythmia mortality rate, 6.5% cardiac mortality rate and 10.5% total mortality rate. This study demonstrates that the programmable implantable pacemaker-cardioverter-defibrillator is effective in preventing arrhythmic death, yet reduces patient exposure to repeated shock therapy. Reprogramming is usually necessary during follow-up for optimal function.

Adolescent

Flecainide therapy in patients treated for supraventricular tachycardia with near normal left ventricular function.

Concerns about the safety and efficacy of class IC antiarrhythmic agents have arisen as a result of the recent CAST data. We reviewed records of 175 consecutive patients treated with flecainide between July 1, 1988 and July 5, 1989. One hundred ten patients with normal or mildly impaired left ventricular function and symptomatic supraventricular arrhythmias were identified. Follow-up data were obtained on 102 patients for a mean of 14 months. The average duration of flecainide therapy was 13 months. Tachyarrhythmias treated included atrial fibrillation/flutter, atrioventricular reentry, and atrioventricular nodal reentry. Flecainide provided effective antiarrhythmic therapy in 62% of the patients and was discontinued in 38% of the patients. Left atrial size did not predict treatment failure. Two patients developed proarrhythmic events (nonsustained ventricular tachycardia). There were no deaths during the follow-up period. In conclusion, flecainide provides safe and effective therapy for supraventricular tachyarrhythmias in patients with normal or mildly impaired left ventricular function.

Atrial Fibrillation

Analysis of deaths in patients with an implantable cardioverter defibrillator.

The cause of death and clinical characteristics of 26 patients that died after implantable cardioverter defibrillator placement were reviewed and compared to the 145 patients still living after a mean follow-up of 17 months. Operative mortality was 4% (7/171) and resulted from postoperative ventricular arrhythmias (four patients), heart failure (two patients), and respiratory failure (one patient). Operative mortality was significantly higher (1.7% vs 9.6%, P less than 0.05) following concomitant surgical procedures. Total late mortality was 11% (18/171). Thirteen deaths (75%) occurred in-hospital from progressive deterioration of left ventricular function (nine patients), arrhythmia (two patients), and noncardiac causes (two patients). Outpatient mortality was 3.5% (6/171) and resulted from presumed sudden cardiac death in five of six patients; two of the five had devices that were inactive, one had high defibrillation thresholds, and two had suspected bradyarrhythmic deaths. One postoperative death and one late in-hospital death were also considered sudden cardiac deaths for a total of seven patients with defibrillation system failures. By multivariant analysis, preoperative clinical characteristics associated with a worse prognosis following defibrillator implantation were identified: presentation as ventricular tachycardia (P less than 0.02), induction of sustained monomorphic ventricular tachycardia (P less than 0.05), poor left ventricular performance (P less than 0.01), poor functional status (P less than 0.001), and the use of diuretics (P less than 0.01). Frequent device discharges (P less than 0.001) and concomitant antitachycardia pacing systems (P less than 0.001) were markers for greater arrhythmia recurrence and were potent predictors of a worse prognosis and particularly sudden death.

Arrhythmias, Cardiac

Pacing lead survival: performance of different models.

UNLABELLED: Recent reports have shown poor survival of some leads currently in use. Long-term survival analysis of 2,444 leads (1,059 atrial and 1,385 ventricular) implanted in this institution since January 1980, and having at least 1 month of follow-up was performed. The survival of 123 different models was compared with the average survival of all the leads implanted in the corresponding chamber. Failure was defined as inactivation of the lead (electrical abandonment, explant, or cap) due to insulator and/or conductor fracture. RESULTS: The mean follow-up was 33 +/- 32 months. The cumulative survival for different atrial lead models was consistent with the average performance in the atrium. No atrial lead showed better or worse survival compared to the others. In the ventricular group, the Medtronic 4012 lead showed statistically significant poorer survival (P = 0.01) compared with the average survival of the ventricular leads. The Cardiac Pacemakers, Inc. (CPI) 4010 lead showed a nonsignificant (P = 0.12) worse performance than the average for ventricular leads. CONCLUSIONS: (1) The Medtronic 4012 had a significantly poorer performance than the rest of the leads. A trend in similar direction was found for the CPI 4010, also in the ventricular group; (2) Atrial lead models showed a stable survival; and (3) Frequent follow-up is required for some leads, especially in pacemaker dependent patients.

Actuarial Analysis

Incidence and predictors of loss of pacing in the atrium in patients with sick sinus syndrome.

Atrial and dual-chamber pacemakers may be associated with reduced morbidity in patients with the sick sinus syndrome (SSS). In some patients, however, subsequent development of chronic atrial fibrillation or atrial lead failure make long-term pacing in the atrium not feasible. We analyzed the incidence and predictors of loss of atrial pacing in 395 consecutive patients with SSS (376 with dual-chamber pacemakers and 19 with single-chamber atrial pacemakers). None of them was in established atrial fibrillation at time of implant. Patients were followed-up for 55 +/- 35 months. Actuarial survival of effective atrial pacing was 92.5% at 1 year, 85% at 5 years, and 76.5% at 10 years. Overall, 60 patients lost atrial pacing. The most frequent cause was the development of chronic atrial fibrillation (53 patients). By multivariate analysis (Cox proportional-hazards model), independent predictors of loss of pacing in the atrium were preimplant episodes of paroxysmal atrial fibrillation (PAF) lasting more than 1 hour (P < 0.001; hazard ratio (HR) = 4.3); prior history of PAF for more than 5 years (P < 0.001; HR = 2.67; and endocardial P wave < 2 mV (P = 0.014; HR = 1.96). In a subgroup of patients (n = 187) who had echocardiograms, a left atrium > 50 mm was also an independent predictor of loss of atrial pacing (P = 0.028; HR = 2.28).(ABSTRACT TRUNCATED AT 250 WORDS)

Actuarial Analysis

Patients with a high defibrillation threshold: clinical characteristics, management, and outcome.

Of 125 patients prepared to receive implantable cardioverter-defibrillators (ICDs) with the patch-patch configuration of the difibrillating electrodes, 23 (18%) had high (greater than or equal to 25 joules) defibrillation thresholds (DFTs). These patients had lower left ventricular ejection fractions (27 +/- 12 vs 34 +/- 13; p less than 0.03) and a higher incidence of previous heart surgery (47% vs 19%; p less than 0.01) than patients with normal DFTs but did not differ in age, type of heart disease, incidence of concomitant heart surgery, or use of antiarrhythmic medication. Defibrillators were implanted in 18 of these 23 patients, 12 during the initial surgery and six after repeat DFT testing 2 weeks later. After 22 +/- 11 months of follow-up, four patients with ICDs died (two suddenly, and two of nonsudden cardiac causes). Two patients without ICDs died of nonsudden cardiac causes. Appropriate shocks were received by five patients (29%) including both who died suddenly later. A high DFT may be more common than previously stated. It is associated with poor ventricular function and previous heart surgery. Repeated DFT testing may be useful in some patients. A high DFT does not preclude successful ICD shocks, but other therapies may provide better results.

Aged

DDIR versus VVIR pacing in patients with paroxysmal atrial tachyarrhythmias.

Patients with sinus node dysfunction (SND) in particular those with tachycardia-bradycardia syndrome and patients undergoing atrioventricular nodal ablation procedures for refractory paroxysmal atrial tachyarrhythmias (PAT), are candidates for single chamber (VVIR mode) or dual chamber rate responsive (DDIR mode) systems. To evaluate the benefits and disadvantages of each pacing mode we retrospectively analyzed 33 patients with a history of frequent PAT who received a VVIR (22 patients); or a DDDR pacemaker (11 patients) programmed to the DDIR mode. The mean follow-up time was 25 and 18 months, respectively. Preimplant left atrial diameter was significantly smaller in the DDIR group. Chronic atrial fibrillation developed in 54% of the VVIR patients and 27% of the DDIR group, but this difference was not significant. Complications of patients with VVIR pacemakers included new mitral and tricuspid insufficiency, stroke, pacemaker intolerance and aggravated congestive heart failure. Patients with DDIR pacemakers had a lower incidence of symptoms and complications. However, this group received more antiarrhythmic medication, required a closer follow-up, and their pacemakers needed frequent reprogramming. Our findings suggest that VVIR is a poor choice for patients with SND, congestive heart failure, and PAT, and that DDIR may be an acceptable alternative.

Anti-Arrhythmia Agents

Early clinical experience with a minute ventilation sensor DDDR pacemaker.

UNLABELLED: The new DDDR pacemaker META DDDR utilizes a minute ventilation sensor based on transthoracic impedance measurements. The sensor determines the metabolic indicated interval, the atrioventricular (AV) delay and the postventricular atrial refractory period (PVARP). The baseline PVARP must be carefully selected to define nonphysiological tachycardias. If a P wave falls within the PVARP the pacemaker will automatically switch to the VVIR mode. This behavior prevents tracking of paroxysmal atrial tachyarrhythmias (PAT). Twenty-eight patients with sinus node dysfunction (n = 20), AV junction ablation (n = 5), complete or intermittent AV block (n = 3); who received a META DDDR pacemaker were studied. The mean age was 65 +/- 13 years. RESULTS: mode switching (reversion) to VVIR was observed in 57% of the patients. Forty-two percent had episodes of mode switching to VVIR during a stress test, four related to PAT, and seven to sinus tachycardia. Fifty percent had episodes of mode switching to VVIR during a 24-hour Holter, four related to PAT, three to retrograde P wave sensing, and two to sinus tachycardia. At the last follow-up, 20 of the 26 patients initially programmed to the DDDR mode remained in the DDDR mode, while five were reprogrammed to the DDD and one to the VVIR mode. Mode switching has a high sensitivity but a low specificity for PAT. It appears to be a useful approach to prevent rapid tracking of atrial tachyarrhythmias. Careful PVARP programming is critical to appropriate reversion behavior, but further modifications of the algorithm are needed to improve its performance.

Aged

Implantable cardioverter defibrillator implanted by nonthoracotomy approach: initial clinical experience with the redesigned transvenous lead system.

Standard implantation procedure for the implantable cardioverter defibrillator (ICD) has traditionally required a thoracotomy approach. A newly revised nonthoracotomy defibrillator lead system that uses a single transvenous tripolar endocardial lead alone or in combination with a subcutaneous/submuscular patch lead was introduced into clinical trials in September, 1990. Fourteen patients requiring a cardioverter defibrillator for recurrent sustained ventricular tachycardia (eight patients) or aborted sudden cardiac death (six patients) were evaluated for implantation of this lead system. Primary successful lead system implantation was obtained in nine patients. The remaining five patients had unacceptably high defibrillation thresholds (DFTs) for implantation. One of the nine initially successful implants demonstrated unacceptable DFTs and cross-talk inhibition from a permanent pacemaker necessitating removal of the nonthoracotomy lead system and replacement with a conventional lead system via thoracotomy. All remaining primary implanted patients experienced successful conversion of induced ventricular fibrillation prior to hospital discharge. Continued follow-up and greater experience to confirm the durability and efficacy of the nonthoracotomy AICD lead system are needed.

Aged

Retrospective analysis of patients undergoing one- or two-stage strategies for myocardial revascularization and implantable cardioverter defibrillator implantation.

Internal defibrillation leads were placed at time of coronary revascularization in 79 patients. In 34, an implantable cardioverter defibrillator (ICD) was placed simultaneously (group I). A two-stage strategy (selective implantation of the ICD in patients with postoperative spontaneous or inducible ventricular tachycardia [VT]) was followed in 45 patients (group II). Group I patients had failed more antiarrhythmic drug trials (2.9 +/- 1.6 vs 1.5 +/- 1.6; P = 0.02), including amiodarone (62% vs 20%; P less than 0.001). There were four operative deaths in each group. Postoperatively, VT was present in 27 group II patients (60%), 25 of whom received an ICD (two refused device implantation). Patients with postoperative VT had a lower left ventricular ejection fraction than those without VT (33 +/- 9 vs 47 +/- 16; P = 0.01). Actuarial survival at 1, 2, and 3 years was 88 +/- 6, 88 +/- 7, and 88 +/- 10 in group I; and 83 +/- 6, 76 +/- 7, and 76 +/- 11 in group II (NS). No patient without an ICD (based on the postoperative electrophysiological study [EPS]) died suddenly. Five patients (6%) had ICD system infection. Sudden death was largely prevented by either strategy, but relatively high rates of operative mortality and ICD system infection were observed. Prospective studies should identify patients more likely to benefit from one or another strategy.

Aged

Chronic transvenous pacemaker lead removal using a unique, sequential transvenous system.

Transvenous removal of 43 consecutive chronic pacemaker leads was successful in 28 patients. For leads not removed by traction at the pacemaker connection terminal, a unique locking stylet was advanced through the inner coil lumen and engaged at the tip to allow traction without lead elongation. Leads not extracted with the locking stylet alone had traction maintained on the stylet as sheaths were advanced over the lead to dilate and detach any fibrous tissue adherent to the lead. By applying traction at the pacemaker connection terminal, 2 leads were removed. The locking stylet alone extracted 9 leads. Both the locking stylet and sheaths were necessary to explant 32 leads. There were 15 right atrial and 22 right ventricular leads completely removed. Additionally, 6 right ventricular leads were subtotally removed leaving only the tip in the right ventricular apex. Avulsed myocardium was removed with the lead in 1 patient without sequelae. A subacute hemothorax developed in 1 patient 18 days after discharge requiring drainage, and subclavian vein thrombosis developed in another, which was successfully treated with anticoagulation. Hypotension occurred in 1 patient during final positioning of new leads, which responded to conservative treatment. Chronic pacemaker leads can be reliably removed without thoracotomy. Both a unique locking stylet to allow traction without lead elongation and a sheath to dilate and detach adherent fibrous tissue are needed for consistent success. Recognized complications included myocardial avulsion without sequelae, subacute hemothorax, subclavian vein thrombosis and transient hypotension.

Adult

Potassium loading as adjunct treatment of repetitive ventricular arrhythmias.

To evaluate potassium supplementation as adjunct therapy for ventricular arrhythmias, consecutive normokalemic patients undergoing in-hospital antiarrhythmic therapy for ventricular tachycardia were randomly assigned to one of four groups: intravenous potassium chloride (Group I, 44 patients) v intravenous saline (Group II, 48 patients); and oral potassium chloride capsules (Group III 50 patients) v no additional treatment (Group IV, 47 patients). All groups underwent serial serum potassium determinations and 24-hour electrocardiographic monitoring. Analysis revealed no significant differences in ventricular ectopic activity among groups, and there was no significant association between serum potassium level and incidence of ventricular arrhythmias. We conclude that normokalemic patients undergoing antiarrhythmic therapy for ventricular tachycardia benefit little from concomitant short-term potassium supplementation.

Female

Pacemaker and defibrillator combination therapy for recurrent ventricular tachycardia.

The judicious use of antitachycardia pacemakers can enhance the benefits of automatic implantable cardioverter defibrillators in certain patients. Both devices were implanted in 10 highly selected patients with drug-refractory pace-terminable sustained ventricular tachycardia. During the observation period of 8 +/- 4.8 months, the automatic pacemakers detected 1,542 episodes of ventricular tachycardia and appropriately managed 1,373. The automatic implantable defibrillator was activated at least once in every patient; on two documented occasions, the defibrillator discharged because the automatic pacemaker accelerated the tachycardia. Concomitant antiarrhythmic drugs could be reduced but not withdrawn. With meticulous device programming and testing, the two systems in combination can work synergistically to manage malignant ventricular arrhythmias in carefully selected patients.

Aged

The use of beep-o-grams in the assessment of automatic implantable cardioverter defibrillator sensing function.

Noninvasive assessment of sensing performance in the automatic implantable cardioverter defibrillator is limited by the absence of telemetry or memory functions. The adaptation of the electrophysiological test mode into a "beep-o-gram" recording, with simultaneous audible tones and a surface electrocardiogram, was used in the confirmation of sensing malfunction. Eleven of 13 recordings in patients with documented or clinically suspected inappropriate defibrillator discharges (group 1) demonstrated evidence of definite oversensing. Nonspecific oversensing or undersensing was present in 77% of 27 randomly selected asymptomatic patients without known sensing malfunction (group 2). The sensitivity and specificity for identifying definite oversensing was 85% and 60%, respectively. The beep-o-gram system is a reliable, noninvasive means of confirming sensing malfunction in the automatic implantable cardioverter defibrillator. Its specificity is limited by the detection of subclinical sensing aberrations, to some degree related to the device's automatic gain control sensing algorithm.

Electric Countershock

The usefulness of head-up tilt testing and hemodynamic investigations in the workup of syncope of unknown origin.

To enhance the clinical evaluation of patients suffering from recurrent syncope of unknown origin, the integrity of mechanisms controlling blood pressure was examined in 151 patients utilizing a screening tilt test. Ninety-eight patients had an abnormal blood pressure and/or heart rate response to tilt testing, including provoked syncopal attacks in 63 patients. Whenever indicated, the screening tilt test was followed by blood volume and hemodynamic determinations, as well as autonomic nervous system testing to identify contributing pathophysiological abnormalities (hypovolemia, venous pooling, autonomic dysfunction). Detailed analysis of this battery of tests allowed us to conclude that: (1) The tilt test is commonly a provocative tool in the workup of patients with recurrent syncope due to vasovagal - vasodepressor reactions and other abnormalities of blood pressure regulation; (2) Its usefulness is augmented by associated hemodynamic and blood volume evaluations; (3) The identification of contributory pathophysiological mechanisms of blood pressure control facilitates specific therapeutic interventions.

Autonomic Nervous System Diseases

Design-dependent cross-talk in a second generation DDD pacemaker.

A unique mechanism of "cross-talk" has recently been described in the Gemini 415A DDD pacemaker in which cross-inhibition of the ventricular output stimulus may occur in the early Gemini 415A models which were manufactured with dual anodal rings interconnected by a wire. The Gemini 415A units with dual anodal rings were implanted under investigational protocol in 53 patients from September 1982 to August 1984. To date, cross-talk has been discovered in six patients during clinical follow-up, manifesting as inappropriate ventricular inhibition. Syncope was documented in one patient. Non-Cordis atrial and ventricular leads were present in all six patients and five patients had at least one chronic lead. Cross-talk was neither evident nor provokable in Gemini 415A units which had compatible Cordis lead systems. Reduction of the atrial output and/or the ventricular sensitivity prevented cross-inhibition in three patients. Cross-talk persisted in three patients despite programming to the lowest atrial output and/or ventricular sensitivity parameters. Cross-talk, spontaneous or provoked, has not occurred in 36 patients having currently designed 415A pulse generators manufactured with a single anodal ring in the ventricular connector channel. We conclude that: this unique form of cross-talk is "design-dependent" and occurs only in Gemini 415As with dual interconnected anodal rings and cannot occur in 415As manufactured with a single anodal ring; this form of cross-talk has occurred only in 415As with non-Cordis leads and appears to be a time-dependent development; reduction of the atrial output or use of pacing modes without atrial pacing or ventricular sensing can prevent cross-talk.(ABSTRACT TRUNCATED AT 250 WORDS)

Bradycardia

Noninvasive assessment of ventriculo-atrial conduction and early experience with the tachycardia termination algorithm in pacemaker-mediated tachycardia.

Since the advent of physiologic dual chamber pacing systems, pacemaker-mediated tachycardia (PMT) has occurred and the need for invasive measurement of ventriculo-atrial conduction (VAC) has arisen. The variability in VAC and the potential for PMT often make it necessary to assess for the presence or absence of VAC at different points in time. We noninvasively evaluated 20 pacemaker patients for the presence or absence of VAC. We compared ventriculo-atrial conduction time (VACT) obtained with the atrial sense event maker with that obtained from Holter monitoring and invasive methods. The incidence of spontaneous (S) and induced (I) PMT and the efficacy of the tachycardia termination algorithm (TTA) was assessed. Fourteen of 20 had VAC with invasive or noninvasive methods. Twelve of 19 had PMT (63%); three were sustained (greater than 15 beats). We conclude that VACT assessed with the atrial sense event marker (ASEM) yielded a high correlation when compared to the Holter monitor data obtained utilizing our methodology. PMT is commonly a nonsustained (less than 15 beats) event, and the TTA is effective in sustained PMT. Myopotential sensing, atrial premature contractions and loss of atrial capture are common mechanisms in the initiation of PMT.