Search PubMed⌕ Search

Biomedical subjects

L Verhey

Publications and source records attributed to L Verhey.

At least 19 recordsLinked to original sources

Registration of magnetic resonance spectroscopic imaging to computed tomography for radiotherapy treatment planning.

The incorporation of multiple imaging modalities into radiotherapy treatment planning offers the potential to improve identification of regions of pathology. This work outlines and evaluates a methodology for registration of magnetic resonance images (MRI) and spectroscopic images (MRSI) to computed tomography (CT) images, and visualization of the multimodality data on the treatment planning workstation. Volumetric magnetic resonance images were acquired during an examination prior to the initiation of radiotherapy. Registration between these images and the treatment planning computed tomography images was performed using an automated alignment routine, and was improved manually using an interactive registration tool. The parameters of the alignment were then used to transform the spectroscopic images into the same reference frame. The spectroscopy data were represented in terms of a statistical measure of abnormality, and embedded within the MRI data as overlaid contours. These images were sent via DICOM transfer to the treatment planning workstation. An analysis of the reproducibility of the

Brain Neoplasms↗

Serial proton MR spectroscopic imaging of recurrent malignant gliomas after gamma knife radiosurgery.

BACKGROUND AND PURPOSE: The diagnosis of brain tumors after high-dose radiation therapy is frequently limited by the lack of metabolic discrimination available with conventional imaging methods. The purpose of this study was to use proton MR spectroscopy to investigate serial changes in recurrent malignant gliomas after gamma knife radiosurgery to characterize tissue response to high-dose radiation. METHODS: Eighteen patients with recurrent gliomas were studied with MR imaging and 3D proton MR spectroscopic imaging at the time of radiosurgery and at regular time points thereafter. Choline (Cho) and N-acetyl aspartate levels were calculated on a voxel-by-voxel basis and compared with levels found in normal tissue and with levels observed at previous time points. The results of the spectral analysis were then compared with the radiologic findings. Statistical comparisons were precluded by the small sample sizes involved. RESULTS: Response within the gamma knife target was observed as a reduction of Cho levels and an increase in lactate/lipid levels, typically within 6 months of treatment. Increases in Cho correlated with poor radiologic response and suggested tumor recurrence, confirmed histologically in six cases. The development of a spectral abnormality preceded a coincident increase in contrast enhancement by 1 to 2 months in nine cases. CONCLUSION: Proton MR spectroscopic imaging provided diagnostic and monitoring information before and after radiosurgery. Evaluation of metabolic changes with proton MR spectroscopy and structural changes with MR imaging improved tissue discrimination and provided correlation with histologic findings.

Adult↗

A preliminary study of the prognostic value of proton magnetic resonance spectroscopic imaging in gamma knife radiosurgery of recurrent malignant gliomas.

OBJECTIVE: The goal of this study was to investigate the use of proton magnetic resonance spectroscopic imaging as a prognostic indicator in gamma knife radiosurgery of recurrent gliomas. METHODS: Thirty-six patients with recurrent gliomas were studied with proton magnetic resonance spectroscopic imaging at the time of radiosurgery, and with conventional magnetic resonance imaging examinations at regular time intervals until the initiation of a new treatment strategy. Patients were categorized on the basis of their initial spectroscopic results, and their performance was assessed in terms of change in contrast-enhancing volume, time to further treatment, and survival. RESULTS: The trends in the overall population were toward more extensive increase in the percent contrast-enhancing volume, a decreased time to further treatment, and a reduced survival time for patients with more extensive initial metabolic abnormalities. Statistical analysis of the subpopulation of patients with glioblastoma multiforme found a significant increase in relative contrast-enhancing volume (P < 0.01, Wilcoxon signed-rank test), a decrease in time to further treatment (P < 0.01, log-rank test), and a reduction in survival time (P < 0.01, log-rank test) for patients with regions containing tumor-suggestive spectra outside the gamma knife target, compared with patients exhibiting spectral abnormalities restricted to the gamma knife target. Further studies are needed to establish statistical significance for patients with lower-grade lesions and to confirm the results observed in this study. CONCLUSION: The pretreatment spectroscopic results provided information that was predictive of outcome for this patient pool, both in local control (change in contrast-enhancing volume) and global outcome (time to further treatment and survival). This modality may have an important role in improving the selection, planning, and treatment process for glioma patients.

Adult↗

Gamma knife radiosurgery as a primary treatment for prolactinomas.

OBJECT: The purpose of this study was to estimate the efficacy of gamma knife radiosurgery (GKS) in controlling tumor growth and endocrinopathy associated with prolactinomas. METHODS: Between 1993 and 1997, 164 of 469 patients with pituitary adenomas treated by GKS harbored prolactinomas. The dose to the tumor margin ranged from 9 to 35 Gy (mean 31.2 Gy), and the visual pathways were exposed to a dose of less than 10 Gy. The mean tumor diameter was 13.4 mm. The mean follow-up time for 128 cases was 33.2 months (range 6-72 months). Tumor control was observed in all but two patients who underwent surgery 18 and 36 months, respectively, after GKS. Clinical cure was achieved in 67 cases. Clinical improvement was noted with a decrease in the hyperprolactinemia after GKS. Nonetheless, in 31 (29%) of 108 patients who were followed for more than 2 years no improvement in serum prolactin levels was demonstrated, although this could be normalized by bromocriptine administration after treatment. Nine infertile women became pregnant 2 to 13 months after GKS and all gave birth to normal children. There was no visual deterioration related to GKS. Five women experienced premature menopause. In these patients there was subtotal disappearance of the tumor and an empty sella developed. CONCLUSIONS: Gamma knife radiosurgery as a primary treatment for prolactinomas can be safe and effective both for controlling tumor growth and for normalization of prolactin hypersecretion. A higher margin dose (> or = 30 Gy) seemed to be associated with a better clinical outcome. Gamma knife radiosurgery may make prolactinomas more sensitive to the bromocriptine.

Humans↗

Static field intensity modulation to treat a dominant intra-prostatic lesion to 90 Gy compared to seven field 3-dimensional radiotherapy.

PURPOSE/OBJECTIVE: Recent studies supported by histopathological correlation suggest that the combined use of endorectal magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS) allows differentiation of normal and carcinomatous prostate. The goal of this study was to use static field intensity modulated three-dimensional conformal radiotherapy (SF-IMRT) to treat the entire prostate to a total dose of >70 Gy, while concurrently treating a dominant intraprostatic lesion (DIL) defined by MRI+MRS to 90 Gy while not exceeding normal tissue tolerances. MATERIALS AND METHODS: For the example chosen, the DIL consisted of a large portion of the peripheral zone of the left lobe of the prostate. University of Michigan (UM-PLAN) three-dimensional treatment planning software was used to design a partially shielded 7 field conformal isodose plan that would treat the entire prostate to >70 Gy at 1.8 Gy per day (80% isodose line), while concurrently treating the DIL to 2.25 Gy per day for a total dose of 90 Gy. Dose volume histograms (DVH) were used to compare the rectal doses to rectum and other adjacent normal tissues using these two techniques. RESULTS: SF-IMRT as described, allowed a total dose of 90 Gy to encompass the DIL, while the rectal dose was slightly lower than that using the standard 7 field technique to the prostate alone. For example, the dose to 30 cm3 of the rectum was 40 Gy using SF-IMRT and 48 Gy for the standard 7 field technique. Because of differences in the dose per fraction the biologic advantages of the SF-IMRT technique are likely to be even greater. CONCLUSIONS: This study demonstrates the feasibility of using SF-IMRT to treat a DIL involving a single lobe of the prostate, as defined by MRI/MRS, to 90 Gy, while simultaneously treating the prostate to >70 Gy without increasing the dose to surrounding normal tissues. A similar approach could be used to treat multifocal disease. This method of treatment is an alternative to dynamic intensity modulation. It is less expensive, and can be adapted to any radiation therapy department without the use of an inverse treatment planning programs.

Humans↗

Proton dosimetry intercomparison based on the ICRU report 59 protocol.

BACKGROUND AND PURPOSE: A new protocol for calibration of proton beams was established by the ICRU in report 59 on proton dosimetry. In this paper we report the results of an international proton dosimetry intercomparison, which was held at Loma Linda University Medical Center. The goals of the intercomparison were, first, to estimate the level of consistency in absorbed dose delivered to patients if proton beams at various clinics were calibrated with the new ICRU protocol, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration factors. MATERIALS AND METHODS: Eleven institutions participated in the intercomparison. Measurements were performed in a polystyrene phantom at a depth of 10.27 cm water equivalent thickness in a 6-cm modulated proton beam with an accelerator energy of 155 MeV and an incident energy of approximately 135 MeV. Most participants used ionization chambers calibrated in terms of exposure or air kerma. Four ionization chambers had 60Co-based calibration in terms of absorbed dose-to-water. Two chambers were calibrated in a 60Co beam at the NIST both in terms of air kerma and absorbed dose-to-water to provide a comparison of ionization chambers with different calibrations. RESULTS: The intercomparison showed that use of the ICRU report 59 protocol would result in absorbed doses being delivered to patients at their participating institutions to within +/-0.9% (one standard deviation). The maximum difference between doses determined by the participants was found to be 2.9%. Differences between proton doses derived from the measurements with ionization chambers with N(K)-, or N(W) - calibration type depended on chamber type. CONCLUSIONS: Using ionization chambers with 60Co calibration factors traceable to standard laboratories and the ICRU report 59 protocol, a distribution of stated proton absorbed dose is achieved with a difference less than 3%. The ICRU protocol should be adopted for clinical proton beam calibration. A comparison of proton doses derived from measurements with different chambers indicates that the difference in results cannot be explained only by differences in 60Co calibration factors.

Algorithms↗

Comparison of radiosurgery treatment modalities based on complication and control probabilities.

PURPOSE: The relative efficacy of Gamma Knife, Linac, and Proton treatment modalities for stereotactic radiosurgery (SRS) was investigated on the basis of normal tissue complication probability (NTCP) and tumor control probability (TCP), calculated for representative test cases. METHODS AND MATERIALS: Five radiosurgery patient cases were selected to cover a range of treatment-planning situations from small spherical volumes to large irregular volumes. A target volume consisting of contours drawn on CT transverse slices was prepared for each case. Plans were developed using the three treatment modalities for each case, with the objective of encompassing the target as closely as possible with a prescription isodose line and minimizing dose to normal tissue, within the constraints of current clinical practice. Dose-volume histograms (DVH) were calculated for the target and for normal tissue, and these histograms were used to calculate NTCP and TCP values for each plan. RESULTS AND CONCLUSIONS: Differences in NTCP and TCP values were found to depend on treatment modality, size, shape, and location of the target, the amount of effort devoted to treatment planning, and the complexity of the plan.

Algorithms↗

The "critical volume tolerance method" for estimating the limits of dose escalation during three-dimensional conformal radiotherapy for prostate cancer.

PURPOSE: To describe the "Critical Volume Tolerance" (CVT) method for defining normal tissue tolerance during 3D-based dose escalation studies for prostate cancer. METHODS AND MATERIALS: The CVT method predicts the tolerance to radiation for "in series"-type functional units based on the assumption that tolerance depends on a critical threshold "low-volume high-dose region." The data used for describing this model were generated from 3D analysis of randomly selected patients with prostate cancer. Commonly used coplanar four-and six-field conformal (SFC) techniques were chosen as the comparison techniques. For purposes of comparison, rectal tolerance was assumed to be reached following whole pelvic irradiation using a four-field box technique to 50 Gy, followed by a conedown boost to 70 Gy using bilateral 9 x 9 cm 120 degree arcs as popularized by investigators from Stanford University (SUH). RESULTS: Based on the average dose volume histograms for the patients studied, the maximum safe increase in dose for the SFC technique compared to the SUH technique, would be 10% if 30% of the rectal volume was the critical dose limiting volume (CVT = 30%), 5% if the CVT = 10%, or greater than 20% if the CVT = 40%. Commonly used four-field conformal techniques would not be expected to allow significant escalation of the dose without increasing the risk of complications. CONCLUSIONS: The CVT method is relatively simple, and data generated based on it can be used to support normal tissue complication probability equations. The CVT method can be verified or modified as partial tolerance data become available. Based on the CVT model, sophisticated treatment techniques should allow a modest increase in the total dose of radiation delivered to the prostate without an increase in late complications.

Dose-Response Relationship, Radiation↗

Proton dosimetry intercomparison.

BACKGROUND AND PURPOSE: Methods for determining absorbed dose in clinical proton beams are based on dosimetry protocols provided by the AAPM and the ECHED. Both groups recommend the use of air-filled ionization chambers calibrated in terms of exposure or air kerma in a 60Co beam when a calorimeter or Faraday cup dosimeter is not available. The set of input data used in the AAPM and the ECHED protocols, especially proton stopping powers and w-value is different. In order to verify inter-institutional uniformity of proton beam calibration, the AAPM and the ECHED recommend periodic dosimetry intercomparisons. In this paper we report the results of an international proton dosimetry intercomparison which was held at Loma Linda University Medical Center. The goal of the intercomparison was two-fold: first, to estimate the consistency of absorbed dose delivered to patients among the participating facilities, and second, to evaluate the differences in absorbed dose determination due to differences in 60Co-based ionization chamber calibration protocols. MATERIALS AND METHODS: Thirteen institutions participated in an international proton dosimetry intercomparison. The measurements were performed in a 15-cm square field at a depth of 10 cm in both an unmodulated beam (nominal accelerator energy of 250 MeV) and a 6-cm modulated beam (nominal accelerator energy of 155 MeV), and also in a circular field of diameter 2.6 cm at a depth of 1.14 cm in a beam with 2.4 cm modulation (nominal accelerator energy of 100 MeV). RESULTS: The results of the intercomparison have shown that using ionization chambers with 60Co calibration factors traceable to standard laboratories, and institution-specific conversion factors and dose protocols, the absorbed dose specified to the patient would fall within 3% of the mean value. A single measurement using an ionization chamber with a proton chamber factor determined with a Faraday cup calibration differed from the mean by 8%. CONCLUSION: The adoption of a single ionization chamber dosimetry protocol and uniform conversion factors will establish agreement on proton absorbed dose to approximately 1.5%, consistent with that which has been observed in high-energy photon and electron dosimetry.

Calibration↗

The value of nonuniform margins for six-field conformal irradiation of localized prostate cancer.

PURPOSE: Evaluate the hypothesis that by combining nonuniform margins with a technique for limiting the possible extent of posterior motion of the prostate during the delivery of six-field conformal radiotherapy (SFCRT) of the prostate, it is possible to adequately treat the clinical target volume (CTV) and minimize dose to normal structures. METHODS AND MATERIALS: Serial computed tomography (CT) scans of prostate patients were taken at 0.5 cm intervals for treatment planning purposes. The initial treatment planning scans were performed with the rectum empty and the bladder full. Subsequent scans were taken at the end of the first week of treatment with the bladder full, but with no attempt to empty the rectum, to mimic the typical treatment situation. The gross tumor volume (GTV), consisting of the prostate and seminal vesicles, as well as the CTV, were defined on the CT images with the aid of a urethrogram to define the inferior border (apex) of the prostate. Variable blocking margins were designed around the CTV using the University of Michigan three dimensional (3D) treatment planning system (UM-PLAN). Isodose distributions displayed on axial, sagittal, coronal, and oblique slices were used to evaluate the adequacy of the various margins applied. Nonuniform margins varying from 0.75 cm posteriorly to 2.0 cm anteriorly and inferiorly were compared to uniform margins of 1.0, 1.5, and 2.0 cm for each patient. Dose volume histograms (DVH) were used to compare doses to the GTV, CTV, rectum, and bladder. RESULTS: In a series of 10 patients scanned with the above protocol, treatment plans with nonuniform margins were compared with uniform margins of 1.0, 1.5, and 2.0 cm. Dose-volume histograms showed that nonuniform and 1.0 cm uniform margins deliver the lowest doses to the rectum and bladder, but the use of 1.0 cm uniform margins resulted in inadequate coverage of the CTV in 40% of the cases. The 1.5 and 2.0 cm uniform margins adequately covered the CTV but resulted in significantly higher doses to the bladder and rectum. CONCLUSIONS: The use of nonuniform margins, when combined with CT scans performed with the rectum empty and bladder full, can improve tumor control probability while minimizing the risk of morbidity to adjacent critical structures.

Humans↗

Comparison of proton and x-ray conformal dose distributions for radiosurgery applications.

Highly focused dose distributions for radiosurgery applications are successfully achieved using either multiple static high-energy particle beams or multiple-arc circular x-ray beams from a linac. It has been suggested that conformal x-ray techniques using dynamically shaped beams with a moving radiation source would offer advantages compared to the use of only circular beams. It is also thought that, generally, charged particle beams such as protons offer dose deposition advantages compared to x-ray beams. A comparison of dose distributions was made between a small number of discrete proton beams, multiple-arc circular x-ray beams, and conformal x-ray techniques. Treatment planning of a selection of radiosurgery cases was done for these three techniques. Target volumes ranged from 1.0-25.0 cm3. Dose distributions and dose volume histograms of the target and surrounding normal brain were calculated. The advantages and limitations of each technique were primarily dependent upon the shape and size of the target volume. In general, proton dose distributions were superior to x-ray distributions; both shaped proton and shaped x-ray beams delivered dose distributions which were more conformal than x-ray techniques using circular beams; and the differences between all proton and x-ray distributions were negligible for the smallest target volumes, and greatest for the larger target volumes.

Biophysical Phenomena↗

Stereotactic radiosurgery in children.

The role of stereotactic radiosurgery in the treatment of pediatric patients is still being explored. We report the Gamma Knife treatment of 33 patients under the age of 21, at the University of California, San Francisco, between the years 1991 and 1993. Treatment-related toxicity has been low. 10/14 patients treated for arteriovenous malformation (AVM) with follow-up > 1 month have shown partial or complete AVM obliteration. No patient has had a new hemorrhage after AVM treatment. In children with malignant tumors, treatment was well tolerated, although most patients, ultimately, had progressive disease. Stereotactic radiosurgery is logistically possible in the pediatric population. Its use in selected patients with AVMs seems appropriate, although its role in the treatment of malignant brain tumors remains to be defined.

Adolescent↗

Defining treatment margins for six field conformal irradiation of localized prostate cancer.

PURPOSE: To define the "ideal margins" to be used for the delivery of six-field conformal radiotherapy for localized prostate cancer. METHODS AND MATERIALS: For a typical patient, 3-D based 6-field conformal treatment plans were generated using uniform margins ranging from 0.5-2.5 cm (in 0.25 cm increments). In a step-wise fashion the minimum margins required to encompass the gross tumor volume within the 90% isodose shell were identified. Additional margins were then added to account for extracapsular penetration, setup and patients movement error as well as for organ movement. Assumptions about the relative tolerance of surrounding normal tissues were also incorporated into the final decisions regarding margins. RESULTS: For the various areas of interface, between the prostate and surrounding normal tissues "ideal margins" varied from 0.75-2.25 cm. CONCLUSION: The use of nonuniform "ideal margins" appears to insure adequate coverage of the tumor, while minimizing the volume of surrounding dose limiting normal tissues irradiated. This approach should in theory improve the tumor control and complication probabilities compared to using conventional treatment techniques and to using a 6-field conformal technique with uniform margins.

Humans↗

Optimization of the oblique angles in the treatment of prostate cancer during six-field conformal radiotherapy.

Historically, four perpendicular treatment fields or bilateral arcs have been used in the treatment of prostate cancer. As new techniques challenge the four-field box technique for their superiority of tumor coverage and adjacent critical structure sparing, oblique beam angles (in addition to right and left laterals) have been introduced as an alternative to anterior (AP) and posterior (PA) beams. Among the most popular of these alternative approaches is a six-field technique. Traditionally 45 degrees angles have been used with this technique. In this study, opposed coplanar oblique beams angled 20, 25, 30, 35, 40, and 45 degrees off the lateral beam position, were compared for their ability to minimize adjacent critical structure doses, while maintaining maximum clinical target volume (CTV) coverage. This analysis compared rectum, bladder, and femoral head dose volume histograms (DVH) for each of these varying oblique gantry angles. As the angle of the posterior oblique beams became more horizontal, it is more difficult to encompass the apex of the prostate in the 95% isodose value. On inferior CT slices near the apex of the prostate, the density of the pelvic bones in the path of the posterior oblique fields causes the beam to be slightly attenuated, thereby underdosing the CTV. The oblique angles most affected by this bone heterogeneity are beams angled from 20 to 30 degrees off the lateral beam position. As the angles approach the vertical direction, rectal and bladder doses increase, while femoral head doses decrease. Oblique gantry angles approaching the horizontal direction result in a decrease in rectal and bladder doses, while femoral head doses increase. Of the oblique angles studied, 35 degrees off the lateral position provides lower rectum and bladder doses than 30, 40, and 45 degrees; lower femoral head doses than 20, 25, and 30 degrees, and the maximum CTV coverage on all CT slices studied.

Adenocarcinoma↗

Beta test site report: gamma plan.

We describe our preliminary experience with a beta-test version of the Leksell Gamma Plan (LGP) treatment planning system. During this testing phase we used the LGP system to find an acceptable treatment plan and then transferred coordinates to the KULA system for final calculation. We find that the LGP system offers a fast way of optimizing shot placement and weighting, especially for complex treatments. The ability to display many MR and CT images on screen and to superimpose isodose lines on these images, as soon as the dose distribution has been calculated, allows adjustments to be made more rapidly than with the plotting approach used by the KULA system. This software is in beta-test, and is undergoing modification. Problems relating to our hardware configuration have been addressed with a newer workstation specified for the production system.

Computer Graphics↗

Consequences to the patient in the event of hydraulic unit failure.

An anomalous hot spot, which occurs when the motion of the Leksell Gamma Unit is halted, was investigated. A series of measurements indicated that the source of this hot spot is the focusing property of the primary collimator. It was determined that this effect is unlikely to result in serious consequences to the patient, even in the event of failure of the hydraulic unit.

Equipment Failure↗

Considerations in fractionated proton radiation therapy: clinical potential and results.

Protons have a finite range in tissue and can provide a better concentration of radiation dose in the tumor than conventional X-rays in certain situations. The development of optimized treatment plans for X-rays and protons followed by a comparative evaluation is one method of selecting tumor sites best suited for proton treatment. The preliminary results of comparative treatment planning for base of skull tumors and carcinoma of the prostate are discussed. These comparisons suggest a clinical gain for proton treatment of tumors in these locations. The clinical experience with fractionated proton treatment of several tumor sites is also discussed. The results of high dose proton treatment of chordomas and low grade chondrosarcomas of the base of skull is particularly promising: an actuarial 5-year local control of 78% has been obtained in 50 patients followed for a minimum of 22 months.

Carcinoma↗

Fractionated proton radiation therapy of cranial and intracranial tumors.

Since 1973 fractionated proton radiation therapy has been used in the treatment of malignant disease. Protons have favorable physical characteristics that yield dose distributions superior to those of photons in certain clinical situations. As of December 31, 1987, 1,678 patients had been treated. Of these, 110 had chordomas or low-grade chondrosarcomas of the base of skull. The first 68 patients have a minimum follow-up of 17 months. The median dose was 69 Cobalt Gray Equivalent (CGE). (CGE is the dose in proton Gray multiplied by 1.1, which is the relative biological effectiveness for protons relative to 60Cobalt.) The actuarial 5-year local control rate is 82%, and the disease-free survival rate is 76%. Thirteen patients with meningiomas have been treated, following subtotal resection. The median dose was 59.4 CGE. With a median follow-up of 26 months, no patient has had tumor progression. In addition, nine patients with gliomas and 12 with craniopharyngiomas have been treated.

Adolescent↗