Search PubMed⌕ Search

Biomedical subjects

L Toivonen

Publications and source records attributed to L Toivonen.

At least 91 records · Page 5Linked to original sources

Itraconazole prevents terfenadine metabolism and increases risk of torsades de pointes ventricular tachycardia.

Terfenadine, a nonsedating H1-selective antihistamine, is widely used in many countries. We report pharmacokinetic results in a patient who developed a prolonged QT-interval in ECG and symptomatic torsades de pointes ventricular tachycardia as a consequence of the interaction of itraconazole and terfenadine. Both drugs were taken in the recommended doses: terfenadine 60 mg b.d. and itraconazole 100 mg b.d. Terfenadine metabolism was delayed by itraconazole, leading to an increased level of unmetabolised terfenadine. Seven weeks after the cessation of itraconazole treatment, terfenadine was rapidly metabolized to its active metabolite and did not prolong the QT-interval when given as a single provocation dose (120 mg). The findings suggest that intraconazole in therapeutic doses inhibits terfenadine metabolism. It is also possible that unmetabolised terfenadine alone, without an increased level of its active metabolite, may cause torsades de pointes. The concomitant use of terfenadine and itraconazole (and ketoconazole) should be avoided.

Adult↗

Identification of patients with ventricular tachycardia after myocardial infarction by high-resolution magnetocardiography and electrocardiography.

The value of time domain analysis of late fields in the high-resolution magnetocardiogram in the identification of myocardial infarction patients with ventricular tachycardia was investigated in 30 subjects: 10 patients with documented sustained ventricular tachycardia and old myocardial infarction, 10 patients with old myocardial infarction without complex ventricular arrhythmias, and 10 normal volunteers. The duration of the QRS complex in the magnetocardiogram was significantly longer in ventricular tachycardia patients compared to myocardial infarction patients (144 (SD, 33) vs 109 (SD, 8) ms; p = 0.004). The root-mean-square field of the last 60 ms of the QRS complex was smaller in ventricular tachycardia patients than in myocardial infarction patients (830 (SD, 650) vs 1,480 (SD, 730) fT, respectively; p = 0.047). Also, the duration of the low-amplitude signal less than 700 fT was longer in ventricular tachycardia patients than in myocardial infarction patients (47 (SD, 28) vs 28 (SD, 8) ms, respectively; p = 0.048). The sensitivity and specificity in identifying ventricular tachycardia patients were both 80%, and the positive and negative predictive values were 78% and 86%, respectively. High-resolution electrocardiography recorded during the same session performed slightly better: sensitivity 90%, specificity 90%, and positive and negative predictive values 90%. The signal-to-noise ratio of electrocardiogram was higher (approximately 2 x) than that of magnetocardiogram. It is concluded that the new magnetocardiographic technique seems helpful in screening patients at risk of ventricular arrhythmias after myocardial infarction. The results encourage further refinement of the technique and application in prospective studies.

Adult↗

Non-invasive magnetocardiographic localization of ventricular pre-excitation in the Wolff-Parkinson-White syndrome using a realistic torso model.

This study was performed to evaluate the accuracy of magnetocardiography in non-invasive localization of the ventricular pre-excitation site in patients suffering from the Wolff-Parkinson-White (WPW) syndrome. Twelve WPW patients were studied, in whom the pre-excitation caused serious supraventricular arrhythmias refractory to drug therapy. Magnetocardiographic measurements were performed in a magnetically shielded room, and non-invasive localization was computed from preprocessed magnetic signals using a current dipole source in a realistically shaped digital torso. All patients underwent intra-operative multicatheter mapping and subsequent dissection of the accessory atrioventricular connection. The intra-operative localization results were marked on magnetic resonance images of the heart, where magnetocardiographic results were also superimposed to allow comparison. The average of the three-dimensional differences between the magnetocardiographic and the invasive results was 2.1 +/- 0.9 cm. In all cases, the computed localization result was in the same or adjacent anatomical region as the intra-operative result. The present results show that the magnetocardiographic method using a realistic torso model is capable of localizing pre-excitation sites with sufficient accuracy to provide extra information so that non-pharmacological therapeutic interventions can be applied.

Adult↗

The influence of intravenous magnesium sulphate on the occurrence of atrial fibrillation after coronary artery by-pass operation.

To examine the influence of magnesium (Mg) on hypomagnesaemia and atrial fibrillation (AF) following coronary artery by-pass surgery, 140 consecutive patients were randomized to receive 70 mmol of magnesium sulphate intravenously (n = 69) or placebo (n = 71). Serum magnesium concentrations fell to 0.77 +/- 0.10 mmol.l-1 in the control group but rose to 1.09 +/- 0.17 mmol.l-1 in the Mg group (P < 0.001). The incidence of AF was 29% in the Mg group and 26% in the placebo group (NS). The AF patients were older, more of them had had prior AF episodes, their sinus rates (SR) were slower (78 +/- 10 vs 86 +/- 12 beats.min-1; P < 0.01) and serum Mg concentrations higher (0.89 +/- 0.21 vs 0.80 +/- 0.11 mmol.l-1; P < 0.05). The incidence of AF was 43% in the highest quartile of serum Mg and 23% among the rest (P = 0.056). In patients experiencing AF during the first three post-operative days, serum Mg concentrations were higher and SR slower on each day compared with non-AF patients. SR increased post-operatively less with high Mg levels (P = 0.044). In the Mg group, serum Mg and SR were the only independent predictors of AF. In conclusion, the incidence of post-operative AF is not decreased with magnesium. High Mg levels are likely to provoke AF probably by mechanisms that modify SR.

Aged↗

Magnetocardiography: supraventricular arrhythmias and preexcitation syndromes.

Magnetocardiography is an elegant non-invasive method with which to study the electrical activity of the heart. The localization of cardiac electric sources, such as arrhythmia foci, would, in particular, be an interesting clinical application. In addition the detection of different abnormalities that could lead to cardiac depolarization and repolarization gives insight into how cardiac arrhythmias and arrhythmia mechanisms are generated. We have studied patients with supraventricular arrhythmias, especially those suffering from the Wolff-Parkinson-White (WPW) syndrome. Magnetocardiographic localization of the preexcitation site was performed in 26 WPW patients, with an average accuracy of 2 +/- 1 cm in comparison to the results obtained by invasive catheter mapping. By inspection of spatial isofield maps during atrial depolarization, the risk of atrial fibrillation was classified correctly in 11/20 (55%) patients with documented atrial fibrillation, and in 4/6 (67%) patients without atrial fibrillation. In a case of focal atrial tachycardia, magnetocardiographic localization of the origin of the arrhythmia was performed during tachycardia. In addition, the level of conduction block was successfully determined in six patients with third-degree congenital atrioventricular block.

Adult↗

Localization of accessory pathways in Wolff-Parkinson-White syndrome by high-resolution magnetocardiographic mapping.

Fifteen patients with Wolff-Parkinson-White syndrome were studied with standard 12-lead electrocardiogram, invasive electrophysiologic study, and high-resolution magnetocardiographic (MCG) mapping. In addition, intraoperative epicardial mapping was performed in seven surgically treated patients. The MCG characteristics of ventricular preexcitation for different locations of the atrioventricular accessory pathways were described in terms of morphology and field patterns. Three mathematical source models in semi-infinite conducting space were used for localization computations: the current dipole model, the truncated current multipole model and the magnetic dipole model. Finally, the localization results of MCG and invasive mappings and electrocardiograms were compared. The mean three-dimensional distance between the localization results obtained from MCG maps and electrophysiologic study was 3.9 cm for the magnetic dipole model, 4.8 cm for the truncated current multipole model, and 7.3 cm for the current dipole model. The corresponding distances in the seven intraoperatively mapped cases were 2.3 cm for the magnetic dipole model, 5.2 cm for the truncated current multipole model, and 6.3 cm for the current dipole model. In conclusion, noninvasive MCG mapping may significantly contribute to the invasive catheter mapping for optimal preoperative localization of preexcitation site and atrioventricular accessory pathways in Wolff-Parkinson-White syndrome.

Adult↗

Alcohol and sauna bathing: effects on cardiac rhythm, blood pressure, and serum electrolyte and cortisol concentrations.

The effect of heavy drinking and sauna bathing on cardiac rhythm, blood pressure, and serum electrolyte and cortisol concentrations was studied in 10 healthy male volunteers. Sauna bathing induced a comparable, significant increase in heart rate with and without alcohol consumption. During sauna bathing without alcohol, systolic blood pressure remained at the baseline level, whereas sauna and alcohol together decreased systolic blood pressure markedly from 136 +/- 4 to 113 +/- 3 mmHg (P less than 0.01). Neither sauna alone, nor sauna combined with alcohol intake, increased the frequency of premature ventricular complexes. Serum potassium, calcium and cortisol concentrations changed slightly during sauna, but alcohol consumption did not contribute further to this. In conclusion, sauna bathing, even in combination with heavy drinking, does not appear to provoke cardiac arrhythmias in healthy young men. However, the risk of hypotension is increased when sauna bathing is combined with alcohol consumption.

Adult↗

The performance of the probability density function in differentiating supraventricular from ventricular rhythms.

The ability of the probability density function (PDF) of an automatic implantable cardioverter defibrillator (AICD) to reject supraventricular arrhythmias being recognized as ventricular was evaluated in 12 patients who were treated with an AICD (Ventak P 1600). The PDF criterion was monitored via telemetry with the sinus rate during exercise test. PDF was satisfied in seven patients at a rate of 75-144/min (mean 109/min), and not in the remaining five patients (mean rate 141/min). PDF was fulfilled in five of ten patients at a lower heart rate than predicted by the duty cycle index, derived from the ventricular patch lead electrogram at the implantation. Thus PDF is often fulfilled already at a moderately elevated sinus rate. If used to prevent inadvertent AICD discharges during rapid supraventricular rhythms, its performance should be tested in the individual patient.

Electric Countershock↗

Coronary collateral circulation.

The occurrence and influence of coronary collateral circulation and obstruction of the supplying coronary arteries on left ventricular contractility, prevalence of myocardial infarction, and bicycle exercise ergometer test were studied in a random sample of 286 patients with angiographically documented coronary artery disease. Collaterals appeared increasingly in all three main coronary arteries with grade of obstruction. The highest prevalence of collaterals occurred in stenosis of the right coronary artery (60%), followed by the left descending artery (45%); they occurred least in the left circumflex artery (21%) (p less than 0.001). The frequency of intra-arterial collateral circulation was 42%, 11%, and 12%, respectively (p less than 0.001). With total occlusion of the left anterior descending coronary artery, 22% of the patients had normokinetic anterior and apical left ventricular wall when collaterals were present. More often, the inferior wall showed normal contraction with total occlusion of the right coronary artery and collaterals [52%, p less than 0.001 compared with left anterior descending artery (LAD)]. The prevalence of inferior myocardial infarction was 39%, with collateral circulation to the totally occluded right coronary artery. The respective prevalence of anterior infarction and total occlusion in the left coronary artery was 58% (p less than 0.02). The presence or absence of collaterals had no obvious influence on ST-segment response during bicycle ergometer test. In triple-vessel disease, peak work capacity was better when collaterals to LAD were not jeopardized (427 kpm) than when jeopardized (321 kpm) (p less than 0.02).

Analysis of Variance↗

The influence of elevated 50 Hz electric and magnetic fields on implanted cardiac pacemakers: the role of the lead configuration and programming of the sensitivity.

The influence of the electromagnetic interference (EMI) on performance of 15 implanted cardiac pacemakers (12 generator models) was tested during exposure at a high voltage substation. All patients had an adequate spontaneous heart rate during the study. Tests were performed in the ventricular inhibited mode with unipolar sensing in all pacemakers and repeated with bipolar sensing in four pacemakers. The sensitivity was set to a regular, functionally proper level and then to the highest available level. Exposure was done to moderate (1.2-1.7 kV/m) and strong (7.0-8.0 kV/m) electric fields, which correspond to the immediate vicinity of 110 and 400 kV power lines, respectively. In moderate electric fields the output was inhibited in one pacemaker at regular sensitivity (1.7-3.0 mV) and in five pacemakers at the highest sensitivity (0.5-1.25 mV). In strong electric fields the output was inhibited in five pacemakers at regular sensitivity and several pacemakers converted to noise reversion mode at the highest sensitivity. In bipolar mode only one of four pacemakers at high sensitivity (0.5-1.0 mV) was inhibited in the strongest electric field, whereas all four did so in the unipolar mode. One pacemaker with unipolar sensitivity at 0.5 mV was interfered by 63 microT magnetic field. The results confirm that the programmed sensitivity level and the lead configuration markedly influence pacemakers' vulnerability to EMI. Bipolar sensing mode is rather safe in the presence of EMI, which is encountered in public environments. The programmable features of today's pacemakers permit individualized, less stringent safety measures to avoid electromagnetic hazards.

Adult↗

A prospective comparison of class IA, B, and C antiarrhythmic agents in combination with amiodarone in patients with inducible, sustained ventricular tachycardia.

BACKGROUND: Clinical experience suggests that combinations of antiarrhythmic agents provide more effective control of ventricular tachyarrhythmias than does therapy with single agents. METHODS AND RESULTS: Antiarrhythmic and electrophysiological effects of three class I antiarrhythmic agents, one from each subclass A, B, and C, were assessed in single use and in combination with amiodarone in patients with inducible, sustained ventricular tachycardia that was not suppressed by monotherapy with these agents. Thirty-one patients underwent an electrophysiology test on four occasions: at baseline; after 2-4 days of treatment with quinidine, mexiletine, or encainide; after 2 weeks of treatment with 1,200 mg/day amiodarone; and last, after 2-4 days of treatment with both amiodarone and the previously tested class I agent. The combination of a class I agent and amiodarone prevented the induction of sustained ventricular tachycardia in only one of 31 (3%) patients. Ventricular tachycardia became hemodynamically stable in 11 of 31 (34%) patients because of a marked prolongation in the tachycardia cycle length. It increased from 323 +/- 39 to 423 +/- 84 msec (n = 11, p less than 0.01) by adding encainide to amiodarone therapy, and it showed a tendency to lengthen when quinidine was added to amiodarone (from 373 +/- 77 to 425 +/- 58 msec; n = 10, NS). Each class I agent increased amiodarone-induced depression in myocardial conduction, but the extent of the additional depression seemed to differ among the three subclasses. Ventricular refractoriness was increased by all class I agents when used in combination with amiodarone, although not by mexiletine or encainide when used alone. CONCLUSIONS: Class I antiarrhythmic agents slow ventricular conduction and increase ventricular refractoriness when used in combination with amiodarone. When amiodarone and class I drugs by themselves do not suppress the induction of ventricular tachycardia, the combination of amiodarone and a class I agent seldom results in noninducibility; however, it often lengthens the ventricular tachycardia cycle length and may render the ventricular tachycardia hemodynamically stable.

Amiodarone↗