Relationship between contact time measurements and PTV values when using the Periotest to measure implant stability.

PURPOSE: The Periotest is an electronic instrument that has been advocated for the measurement of implant stability and osseointegration. The aims of this investigation were to establish the relationship between contact time and PTV values when the Periotest was used to assess implants in vivo and in vitro, and to investigate the influence of the striking height of the Periotest handpiece and the length of implant abutment. MATERIALS AND METHODS: The accelerometer signal from a Periotest was captured and compared with the resulting PTV value. In vitro measurements of PTV and contract time were performed on a 3-mm abutment that had been attached to a 15-mm implant luted into an aluminium block, and were repeated on a patient in vivo. further measurements were made of the abutments of six implants in turn in the maxilla of the same patient. The standard abutment lengths on the implants were 3, 4 (x 2), 5.5 (x 2), and 7 mm. RESULTS: The results indicated that there was a linear relationship between contact time and PTV value for implants measured in vitro and in vivo. Greater scatter of the in vivo data was attributed to test and patient variables including striking position, distance, and damping as a result of the presence of soft tissue. There was a linear relationship between the PTV value and the striking height for implant measurements in vivo and in vitro. CONCLUSION: It can be concluded that the sensitivity of the Periotest to clinical variables including striking heights and handpiece angulation limit the application of the instrument as a clinical diagnostic aid to measure implant stability.

Dental Abutments↗

Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature.

PURPOSE: This article reviews the current knowledge about the influence of surgical factors on implant failure in routine cases and in those where implants have been used in conjunction with bone augmentation procedures. MATERIALS AND METHODS: Clinical reports published in major scientific journals served as the basis for this review. RESULTS: With few exceptions, most clinical reports were on screw-shaped titanium implants. High failure rates are associated with poor bone quality and the use of short implants in the athrophic maxilla, irradiation, and bone-grafting procedures of the athrophic maxilla. Evidence for high long-term failure rates of press-fit cylinders was found. Moreover, limited clinical experience, lack of preoperative antibiotics, and smoking may lead to higher failure rates. CONCLUSION: There is a need for further research to increase the success rates in the severely resorbed maxilla. Because of a lack of proper documentation with respect to the great majority of currently used oral implant designs, the influence of different factors and their long-term results remain unknown.

Alveolar Bone Loss↗