Serial VCG/ECG analysis using neural networks.

Serial ECG analysis is an important diagnostic tool in which two or more successive ECG recordings from the same patient are compared in order to find changes due to, e.g. myocardial infarction. The present study investigates a new approach to serial analysis which is based on artificial neural networks. Interrecording changes are sometimes falsely detected due to electrode misplacement or positional changes of the heart. In order to compensate for such problems, a new technique for VCG loop alignment was employed. A study population of 1000 patients with two recordings was used and manually scrutinized by three experienced ECG interpreters. Pathological changes indicating newly developed infarcts were found in 256 patients. Different combinations of VCG/ECG measurements served as input data to the neural network. The best performance of the neural network was obtained when ECG and VCG measurements were combined and the resulting sensitivity was 69% at a specificity of 90%. The use of only ECG or VCG measurements reduced the sensitivity to 63% and 60%, respectively. The results indicated that serial analysis based on neural networks did not improve significantly when VCG loop alignment was included.

Case-Control Studies↗

Comparative study of local and Karhunen-Loève-based ST-T indexes in recordings from human subjects with induced myocardial ischemia.

In this work we studied ST-T complex changes in the ECG as result of induced ischemia. The principal aim was to determine whether global changes in the ST-T complex were more sensitive markers of ischemic alterations than those based on measurements of changes at specific locations on ST segment or T wave. High-resolution ECGs from patients undergoing percutaneous transluminal coronary angioplasty in one of the major coronary arteries were analyzed to give a description of the period from the end of active depolarization (QRS complex) to the end of active repolarization (T wave). During artery occlusion traditional local measurements of the ST-T complex were compared to global measurements based on the Karhunen-Loève transform. An ischemic change sensor parameter was estimated for each of the studied indexes showing that global measurements detected changes better in the repolarization period in a larger number of leads and with higher sensitivity (more than 85%) than was done using local measurements (sensitivity of 64% with ST level, 33% with T-wave maximum position, and 37% with T-wave maximum amplitude). Using these global indexes it was found that most cases of ST-segment changes were accompanied by T-wave changes (72% of patients). With the use of traditional indexes 23% of patients showed no changes in the repolarization period, whereas with global indexes this percentage decreased to 8%. Thus a global representation of the entire ST-T complex appears to be more suitable than local measurements when studying the initial stages of myocardial ischemia.

Algorithms↗

Non-invasive assessment of the atrial cycle length during atrial fibrillation in man: introducing, validating and illustrating a new ECG method.

OBJECTIVES: Atrial fibrillation (AF) in man has previously been shown to include a wide variety of atrial activity. Assessment of the characteristics of this arrhythmia with a commonly applicable tool may therefore be important in the choice and evaluation of different therapeutic strategies. As the AF cycle length has been shown to correlate locally with atrial refractoriness and globally with the degree of atrial organization, with, in general, shorter cycle length during apparently random AF compared to more organized AF, we have developed a new method for non-invasive assessment of the AF cycle length using the surface and the esophagus (ESO) ECG. METHODS AND RESULTS: From the frequency spectrum of the residual ECG, created by suppression of the QRST complexes, the dominant atrial cycle length (DACL) was derived. By comparison with multiple intracardiac simultaneously acquired right and left AF cycle lengths in patients with paroxysmal AF, we found that the DACL in lead V1, ranging from 130 to 185 ms, well represented a spatial average of the right AF cycle lengths, whereas the DACL in the ESO ECG, ranging from 140 to 185 ms, reflected both the right and the left AF cycle length, where the influence from each structure depended on the atrial anatomy of the individual, as determined by MRI. In patients with chronic AF, the method was capable of following changes in the AF cycle length due to administration of D,L-sotalol and 5 min of ECG recording was sufficient for the DACL to be reproducible. CONCLUSIONS: We conclude that this new non-invasive method, named 'Frequency Analysis of Fibrillatory ECG' (FAF-ECG), is capable of assessing both the magnitude and the dynamics of the atrial fibrillation cycle length in man.

Adult↗

Beat-to-beat QRS variability in the 12-lead ECG and the detection of coronary artery disease.

The aim of this article was to study beat-to-beat QRS variability in patients with ischemia and old myocardial infarction using the 12-lead resting electrocardiogram (ECG). The variability analysis was based on beats that have been synchronized in time with an iterative alignment technique. The QRS variability was measured in patients submitted for myocardial scintigraphy. Those with a normal myocardial scintigraphy (called NO, n = 34, mean age 57 years, 23 women) were compared with a group with both myocardial infarction and exercise-induced ischemia (called ISCINF, n = 27, mean age 57 years, 5 women). The mean QRS variability was somewhat smaller in lead I in ISCINF than in NO, and there was no statistically significant difference in QRS variability among the groups in leads II, III, and V1-V6. Using a multivariate approach, the joint variability in leads I, II, II, and V1-V6 was used for calculating receiver operating characteristics based on a leave-one-out procedure. The sensitivity for detecting coronary artery disease was 75% at a specificity of 50%. It is concluded that beat-to-beat QRS variability in the 12-lead ECG does not discriminate between the presence and absence of coronary artery disease sufficiently well for clinical purposes.

Coronary Disease↗

Electrocardiographic changes during prolonged coronary artery occlusion in man: comparison of standard and high-frequency recordings.

Detection of acute myocardial ischaemia using electrocardiographic methods is generally based on assessment of the ST segments in the standard 12-lead electrocardiogram (ECG). Several studies have also shown changes in high-frequency QRS components during acute ischaemia. The purpose of the present study was to determine the changes in high-frequency QRS components during prolonged percutaneous transluminal coronary angioplasty (PTCA) and to compare these changes with ST-segment deviations in the standard 12-lead ECG. The study population consisted of 19 patients receiving prolonged PTCA. Standard and high-resolution signal-averaged ECGs were recorded before and during balloon inflation. The high-resolution recordings were performed using bipolar X, Y and Z leads. The QRS complexes in the high-resolution signal-averaged ECGs were analysed within a bandwidth of 150-250 Hz. During inflation, significant reductions in high-frequency QRS components were observed (12-72%). Changes in the high-frequency QRS components were seen in four of the patients without ST-segments deviation in the standard ECG. The correlation between the ST-segment deviation and the reduction in high-frequency QRS components was weak (r = 0.27). Acute coronary artery occlusion produces changes in high-frequency QRS components, even in the absence of ST-segment deviation in the standard ECG. Further studies need to be carried out to evaluate whether analysis of high-frequency QRS components could provide a method for detecting myocardial ischaemia and give additional information to that available in the ST segment in the standard ECG.

Adult↗

Non-invasive assessment of magnitude and dispersion of atrial cycle length during chronic atrial fibrillation in man.

AIMS: Atrial fibrillation cycle lengths can be assessed from right precordial ECG leads and the unipolar oesophageal ECG using a non-invasive method called Frequency Analysis of Fibrillatory ECG. The purpose of this report is to present the results from application of this method in a large group of patients with long-term atrial fibrillation and to examine the differences between patients with 'coarse' and 'fine' atrial fibrillation. METHODS AND RESULTS: Simultaneous 15 min recordings from V1, V2 and an oesophageal lead at a position behind the posterior atrium were obtained in 28 patients, aged 41 to 78 years, with long-term (> 1 month) atrial fibrillation. In each lead, using the time averaging technique, the QRST complexes were suppressed. Thereafter, the frequency distribution of the residual ECG was estimated by means of Fast Fourier Transform. In the 3-12 Hz range of each lead, the dominant atrial cycle length, the power maximum and the spectral width were calculated. In 26 patients (93%), frequency spectra in the 3-12 Hz range could be obtained. The dominant atrial cycle length ranged from 120 to 175 ms, mean 150+/-16 (SD) ms in V1, and from 120 to 190 ms, mean 150+/-16 in an oesophageal lead (ns). The absolute difference in the dominant atrial cycle length between V1 and the oesophageal lead was 10.4+/-7.7 ms. There was no significant difference in the dominant atrial cycle length in V1 between patients with coarse and fine atrial fibrillation. The power maximum in V1 was significantly greater in patients with coarse compared to fine atrial fibrillation (P=0.01). The spectral widths ranged from 10 to 55 ms and demonstrated significantly higher mean values in lead V2 compared to V1 (P=0.001). Compared to V1, the mean values tended to be smaller in the oesophageal lead (P=0.05). CONCLUSIONS: Using the Frequency Analysis of Fibrillatory ECG method, the dominant atrial cycle length, power maximum and spectral width can be estimated from the frequency spectra in the majority of patients with atrial fibrillation. Spatial dispersion of the dominant atrial cycle length occurs in some patients and may be an important proarrhythmic marker. The distinction between coarse and fine atrial fibrillation cannot be used as a marker of the atrial cycle length.

Aged↗

Vectorcardiographic loop alignment and morphologic beat-to-beat variability.

The measurement of subtle morphologic beat-to-beat variations in the electrocardiogram is complicated by the presence of respiration-induced movements of the heart. A statistical signal model is developed which accounts for such movements by means of scaling, rotation, and time synchronization of vectorcardiographic loops. The maximum-likelihood estimator of the parameters describing these three transformations is presented and is extended to the case of multiple loop alignment. The performance of the method is assessed by measuring morphologic variability before and after loop alignment. It is shown that the effects of respiration on morphologic variability can be considerably reduced by the new method. Measurements on morphologic variability were typically reduced by a factor of 0.53 after loop alignment. The results show also that beat-to-beat measurements are strongly dependent on the selected sampling rate and that a rate of 1 kHz is too low.

Electrocardiography↗

Detection of cardiac late potentials in nonstationary noise.

An 'instantaneous' optimal filter is presented for improving the signal-to-noise ratio in averaged electrocardiograms (ECGs). The filter design is based on a simple model that accounts for correlation across the ensemble of beats but ignores correlation in time. Another property of the model is that the noise level is allowed to change from beat to beat. Simulation results indicate that an improved performance is achieved by the new filter when compared to a filter with a similar structure but designed for processing beats with a constant noise level. Several ECG examples are included to demonstrate the performance of the filter for detecting late potentials.

Algorithms↗

Maximum likelihood analysis of cardiac late potentials.

This study presents a new time-domain method for the detection of late potentials in individual leads. Basic statistical properties of the ECG samples are modeled in order to estimate the amplitude and duration of late potentials. The signal model accounts for correlation in both time and across the ensemble of beats. Late potentials are modeled as a colored process with unknown amplitude which is disturbed by white, Gaussian noise. Maximum likelihood estimation is applied to the model for estimating the amplitude of the late potentials. The resulting estimator consists of an eigenvector-based filter followed by a nonlinear operation. The performance of the maximum likelihood procedure was compared to that obtained by traditional time-domain analysis based on the vector magnitude. It was found that the new technique yielded a substantial improvement of the signal-to-noise ratio in the function used for endpoint determination. This improvement leads to a prolongation of the filtered QRS duration in cases with late potentials.

Action Potentials↗

Increased sensitivity for the diagnosis of healed myocardial infarction using vectorial information in the 12-lead ECG.

The aim of this study was to use the vectorial information in the conventional 12-lead electrocardiographic (ECG) recording and to investigate whether this information, in combination with well-known ECG criteria, could increase the diagnostic performance for healed anterior or inferior myocardial infarction. A total of 1,458 subjects were included in the study; 272 patients with anterior myocardial infarction, 356 patients with inferior myocardial infarction, and 830 subjects classified as normal. New 12-lead vectorcardiographic criteria for anterior and inferior myocardial infarction were developed and used in combination with well-known ECG criteria. The combined criteria showed a sensitivity of 80.0% and 72.4% for the diagnosis of anterior and inferior myocardial infarction, respectively. The corresponding sensitivities for the conventional ECG criteria were significantly lower. In conclusion, the addition of vectorial parameters into ECG interpretation programs could be of value.

Diagnosis, Computer-Assisted↗

Reproducibility of the signal-averaged electrocardiogram using individual lead analysis.

The aim of the study was to evaluate the immediate reproducibility of time domain parameters in the signal averaged electrocardiogram using a new method for endpoint determination in individual Frank leads. The method is based on a statistical model of the electrocardiogram (ECG) in which maximum likelihood (ML) estimation is employed. The reproducibility of the ML method was compared to that of conventional time domain analysis using the vector magnitude (VM) of Frank leads. Fifty-nine patients were included in the study and two consecutive ECGs were recorded for signal averaging. The results showed that the mean of the absolute difference of the filtered QRS duration (QRSD) between two consecutive recordings was significantly lower for the ML method than the conventional method when employing 60 Hz highpass filtering (2.1 +/- 2.2 ms vs 5.9 +/- 10.2 ms, P < 0.05). Moreover, the ML method resulted in a significantly longer QRSD compared to the VM-based method (P < 0.05). The terminal amplitude of the QRS complex (RMS40) showed a greater variability than the QRSD for both methods, although the ML method was associated with a higher reproducibility than the VM method for the 60 Hz filter. These findings may contribute to a better identification of patients at high risk of ventricular arrhythmias. A reduction in the number of measurement errors has important implications when QRS changes are analysed over time.

Adult↗

Signal-to-noise ratio enhancement of cardiac late potentials using ensemble correlation.

An optimal one-weight "filter" is presented for the purpose of improving the signal-to-noise ratio of averaged ECG recordings in the analysis of late potentials. Based on a simple statistical model, the filter is estimated from the ensemble correlation of available beats. The correlation estimator is found by a maximum likelihood procedure in which the observed signal is assumed to have a Gaussian distribution. The performance of the optimal filter is studied in relation to an ensemble with individual or subaveraged beats.

Action Potentials↗

Effects of digital resolution on characterisation of cardiac late potentials.

The effects of amplitude resolution in the signal-averaged ECG are studied in relation to the analysis of cardiac late potentials. The statistical properties of ECG signals from 22 patients after myocardial infarction were investigated in terms of amplitude distribution and noise level for the material. It was found that unbiased averaging could be achieved using a resolution greater than 10 microV. The noise levels of the bandpass-filtered individual X, Y and Z leads (range of 1-10 microV) and the vector magnitude were also investigated. Marked intra-lead differences in noise level were found, indicating that analysis based on individual leads is preferable. The effects of quantisation noise on the vector magnitude were negligible for amplitude resolutions below 5 microV. However, the additional noise contribution at 5 microV could be compensated by a moderate increase in acquisition time. The sensitivity to noise was considered when determining the endpoint of the filtered QRS complex using the vector magnitude.

Electricity↗

Biexponential pulmonary clearance of 99mTc-DTPA induced by detergent aerosol.

We measured the pulmonary clearance of technetium-99m-labeled diethylenetriamine pentaacetatic acid (99mTc-DTPA) for 3 h after perturbation of the surfactant system by administration of the detergent dioctyl sodium sulfosuccinate in aerosol. Forty-two rabbits were anesthetized with pentobarbital sodium. Tracheostomies were performed, and the rabbits were mechanically ventilated. Increasing concentrations of detergent (0.125-2%) or vehicle were given for 5 min, and clearance measurements were performed immediately or 60 min after detergent administration. No animals developed respiratory distress. After vehicle, the clearance was monoexponential with a half-life of 153 min. Detergent induced a biexponential clearance with a rapidly clearing additional pool of radioactivity with a half-life of 5-15 min. The relative amount of radioactivity clearing rapidly increased with detergent concentration. The detergent effect was partly reversible. We conclude that detergent induces a biexponential clearance of 99mTc-DTPA by accelerating the transfer of tracer across the alveolocapillary barrier in a proportion of lung units in a dose-related manner.

Aerosols↗

Time-varying digital filtering of ECG baseline wander.

Time-varying filtering techniques are applied to the problem of baseline correction by letting the cut-off frequency of a linear filter be controlled by the low-frequency properties of the ECG signal. The time-varying filter is implemented as a bank of linear low-pass filters, in which each filter has a slightly differing cut-off frequency. Sampling rate decimation and interpolation are employed because the design of a filter for baseline reduction can be treated as a narrowband filtering problem. All filters have a linear phase response to reduce, for example, ST-segment distortion. The performance of the technique presented is studied on ECG signals with different types of simulated baseline wander. The results are compared with the performance of time-invariant linear filtering and cubic spline interpolation. The results show that an improvement in performance can be achieved when using time-varying filtering, especially at low heart rates or during episodes with excessive base-line wander.

Electrocardiography↗

Reconstruction of the electrocardiogram during heart surgery.

Electrocardiograms (ECG) recorded during arrhythmia surgery are used for identification of arrhythmias of different morphology. However, the interpretation of an intraoperative ECG is difficult because some leads cannot be recorded and the signals of the remaining leads often differ from those of a preoperative recording because of the sternotomy. Therefore, a method for reconstruction of a complete intraoperative ECG, which resembles a preoperatively recorded ECG, was studied in 24 patients undergoing heart surgery. The reconstruction method involves calculating coefficients for a transformation matrix, using a preoperative ECG recording and a first intraoperative ECG recording. Once this matrix has been established, further intraoperative recordings can be transformed into an ECG which strongly resembles a preoperative ECG. The correlation between reconstructed intraoperative leads and the corresponding preoperative leads was high in the leads Vx and Vy (median correlation coefficient 0.98 and 0.97) and slightly smaller in lead Vz (0.94). Further studies will prove if the method can be useful in arrhythmia surgery.