Search PubMed⌕ Search

Biomedical subjects

L S Czer

Publications and source records attributed to L S Czer.

At least 55 records · Page 3Linked to original sources

Results of early repair of ventricular septal defect after an acute myocardial infarction.

A 10-year experience with early operation for postinfarction ventricular septal defect is reviewed. Twenty-two patients underwent surgical repair; operative mortality was 36% (< 30 days). The actuarial survival was 64% at 1 month, 59% at 1 year, and 47% at 5 years. Risk factors predictive of operative mortality were diabetes (p = 0.001), elevated preoperative right atrial pressure (p = 0.02), the absence of a preoperative intraaortic balloon pump (p = 0.006), and a short time interval between infarct and operation (p = 0.018). Long-term survival was adversely related to diabetes (p = 0.030), elevated preoperative right atrial pressure (p = 0.005), and, surprisingly, survival was better in patients with a greater extent of coronary artery disease (p = 0.023). There were 14 operative survivors (64%) and 11 long-term survivors (3 months to 10 years, mean 6.0 +/- 3.5 years). Six of eleven survivors were in functional New York Heart Association class I, one was in class II, and four were in class III.

Aged↗

Comparative efficacy of ring and suture annuloplasty for ischemic mitral regurgitation.

BACKGROUND: Patients with ischemic mitral regurgitation (MR) represent a therapeutic challenge, and results after combined valve replacement and revascularization have been poor. Valve repair is a promising approach, but the optimal method of repair is not known. METHODS AND RESULTS: In 60 patients with coronary artery disease and 3+ or 4+ MR, we used intraoperative Doppler echocardiography to study the efficacy of Carpentier-Edwards ring (n = 27) and commissural suture (n = 33) annuloplasty. Patients with ruptured papillary muscles, torn chordae, and ballooning or scalloping of the leaflets were excluded. Ring and suture groups were similar in preoperative ejection fraction (35 +/- 14% and 34 +/- 17%), MR grade (3.5 +/- 0.5 and 3.4 +/- 0.6), and acuity of MR (41% and 33% acute) (p = NS). Postoperatively, the ring group achieved a lower residual MR grade than the suture group (0.5 +/- 0.5 versus 1.5 +/- 1.1; p < 0.001), and the mitral annular diameter was reduced to a greater extent in the ring group (by 1.5 +/- 0.5 cm versus 0.5 +/- 0.4 cm; p < 0.001). Success (> or = 2 grade MR reduction) was more frequent in the ring than in the suture group (96% versus 67%, p < 0.01). One-year survival was similar (74 +/- 9% ring, 71 +/- 8% suture). Follow-up Doppler studies showed a higher mean gradient (4.0 +/- 1.2 mm Hg) and smaller valve area (2.1 +/- 0.5 cm2) in the ring group, but the postoperative New York Heart Association class was similar in both groups (83% versus 74% class I-II). CONCLUSIONS: Ring annuloplasty provides a more effective reduction of ischemic MR and a higher success rate than the suture technique. This may be related to uniform rather than localized shortening of the annulus and a greater reduction in annulus diameter.

Aged↗

Excimer laser angioplasty during aortocoronary bypass grafting.

Laser coronary angioplasty using the 308-nm Excimer laser was successfully performed intraoperatively during coronary artery bypass grafting. It achieved a reduction of the left anterior descending artery stenosis from 99% to 25% as seen on angioscopy, without evidence of vascular perforation or intimal disruption. The Excimer laser offers the opportunity for intraoperative endovascular remodeling and recanalization and has a potential role as an adjunct to existing standard coronary artery bypass grafting protocol.

Angioplasty, Laser↗

Intraoperative color Doppler assessment in valve repair surgery.

Intraoperative color Doppler recordings, obtained either from the epicardial or transesophageal approach, offer real-time information about the presence and severity of mitral regurgitation at the time of surgery. The technique allows instantaneous evaluation of mitral and tricuspid repair and may offer important information about the postoperative outcome.

Echocardiography, Doppler↗

The use of color flow mapping for intraoperative assessment of valve repair.

Repair procedures that preserve a patient's native valve are associated with a lower perioperative and late mortality, a lower incidence of thromboembolic events, and better preservation of left ventricular function than prosthetic replacement. Traditionally employed procedures for intraoperative assessment of the adequacy of repair, such as fluid injection into the arrested ventricle for assessment of valve leakage, measurement of atrial pressure and height of V-waves, and palpation of the atria for the presence of systolic thrills, have not proved to be reliable approaches in the intraoperative evaluation of mitral and tricuspid regurgitation and in the assessment of the adequacy of repair procedures. Intraoperative color Doppler, using either the epicardial or the transesophageal approach, offers rapid and accurate information about the presence and severity of mitral regurgitation at the time of surgery. This technique provides instantaneous evaluation of the adequacy of mitral and tricuspid valvuloplasty and appears capable of predicting postoperative outcome. Intraoperative color Doppler is useful for evaluation of the adequacy of repair before chest closure and may thus help to avoid the need for reoperation. This approach may ultimately allow valve repair procedures to be performed in greater numbers of patients with better control over outcome and with lower reoperation rates.

Echocardiography, Doppler↗

Increased mortality of women in coronary artery bypass surgery: evidence for referral bias.

STUDY OBJECTIVE: To determine whether differences in referral reasons explain the higher operative mortality of women in coronary artery bypass surgery. DESIGN: Case series. SETTING: A tertiary care, private teaching hospital. PATIENTS: Consecutive patients who had isolated coronary artery bypass surgery between 1982 and 1987 (total, 2297; 79% male and 21% female). MEASUREMENTS AND MAIN RESULTS: The inhospital mortality rate was significantly higher for women than for men (4.6% compared with 2.6%; P = 0.036; 95% CI for difference in mortality, 0% to 4.0%). Women were older than men (mean, 68.2 and 64.0 years, respectively; P less than 0.001), and a higher percentage of women were referred with unstable angina (P = 0.007), postmyocardial infarction angina (P = 0.029), congestive heart failure (P less than 0.001), and New York Heart Association class IV symptoms (66% compared with 45%, P less than 0.001). More men were referred with a history of an abnormal exercise test (P less than 0.001), and patients referred because of a positive exercise test had a lower mortality (P less than 0.001). Using multivariate analysis, adjustment for the higher preoperative functional class of women and for age accounted for all of the difference in mortality between men and women (odds ratio, 1.04; CI, 0.60 to 1.79; P = 0.89). After correction for functional class alone, there continued to be no significant difference in mortality between men and women (P = 0.40). CONCLUSIONS: Differences in functional class and age account for the higher operative mortality of women in coronary bypass surgery. Women are referred for coronary bypass surgery later in the course of their disease than men, and later referral may increase their changes of operative death.

Adult↗

Intraoperative echocardiography in mitral and tricuspid valve repair.

Echocardiography with Doppler color flow mapping is a very useful intraoperative technique in patients undergoing mitral or tricuspid valve repair. In the patient who is a repair candidate, this technique can be used intraoperatively to answer important clinical questions: the severity of the regurgitation; the morphological basis of the regurgitant lesion; and the feasibility of repair. Other important issues such as the impact of physiological interventions on regurgitation severity, the presence of associated lesions, and the state of ventricular function can also be addressed. In the patient who has undergone a valve repair, this technique can be used intraoperatively prior to chest closure to assess the adequacy of the repair procedure and to detect associated complications such as outflow tract obstruction.

Echocardiography, Doppler↗

Ten-year experience with the St. Jude Medical valve for primary valve replacement.

The St. Jude Medical valve is a bileaflet prosthesis with excellent hemodynamic characteristics, but the long-term surgical experience with this valve, its durability, and its biocompatibility are unknown. During a 10-year period from March 1978 to 1988, 690 prostheses (290 aortic, 252 mitral, and 74 double aortic-mitral) were inserted as the initial valve replacement substitute in 616 patients (mean age 63 years). Coronary atherosclerosis was present in 58%. Follow-up totaled 2031 patient-years (mean 3.3 years) and was 95% complete (32 lost). Early (30-day) mortality rates were 5.2%, 11.9%, and 8.1% after aortic, mitral, and double valve replacement; 5- and 9-year actuarial survival rates were 71% +/- 3% and 51% +/- 8%, 59% +/- 4% and 41% +/- 6%, and 69% +/- 6% and 47% +/- 15%, respectively. Deaths were associated with extensive coronary atherosclerosis (p less than 0.001), older age (p less than 0.001), advanced preoperative New York Heart Association functional class (p less than 0.05), and malignant ventricular arrhythmias (p less than 0.05). No structural failures have been observed. Embolism (40 events) occurred at a rate of 2.0%/pt-yr (2.3% aortic, 1.6% mitral, 2.0% double). There were six cases of valve thrombosis (0.3%/pt-yr; one fatal). Hemorrhage was the most frequent complication (2.6%/pt-yr); 13 (25%) of 52 events were fatal, accounting for 62% of all valve-related deaths. After the target prothrombin time ratio was lowered, the rate of hemorrhage decreased by 44% (2.7% to 1.5%/pt-yr), while the combined rate of embolism and valve thrombosis increased slightly (2.2% to 2.5%/pt-yr, a 14% change). In summary, the St. Jude Medical valve remains a durable valve substitute. Survival was strongly related to the presence of associated coronary atherosclerosis. The most common complication has been hemorrhage; a less intensive warfarin regimen may reduce hemorrhagic risk while maintaining thromboembolic protection.

Adolescent↗

A quantitative comparison of transesophageal and epicardial color Doppler echocardiography in the intraoperative assessment of mitral regurgitation.

Epicardial and transesophageal color Doppler echocardiography are both widely used for the intraoperative assessment of mitral regurgitation (MR); however, it has not been established whether grading of regurgitation is comparable when evaluated by these 2 techniques. MR jet size was quantitatively compared in 29 hemodynamically and temporally matched open-chest epicardial and transesophageal color Doppler echocardiography studies from 22 patients (18 with native and 4 with porcine mitral valves) scheduled to undergo mitral valve repair or replacement. Jet area, jet length and left atrial area were analyzed. Comparison of jet area measurements as assessed by epicardial and transesophageal color flow mapping revealed an excellent correlation between the techniques (r = 0.95, p less than 0.001). Epicardial and transesophageal jet length measurements were also similar (r = 0.77, p less than 0.001). Left atrial area could not be measured in 18 transesophageal studies (62%) due to foreshortening, and in 5 epicardial studies (17%) due to poor image resolution. Acoustic interference with left atrial and color flow mapping signals was noted in all patients with mitral valve prostheses when imaged by epicardial echocardiography, but this did not occur with transesophageal imaging. Thus, in patients undergoing valve repair or replacement, transesophageal and epicardial color flow mapping provide similar quantitative assessment of MR jet size. Jet area to left atrial area ratios have limited applicability in transesophageal color flow mapping, due to foreshortening of the left atrial borders in transesophageal views. Transesophageal color flow mapping may be especially useful in assessing dysfunctional mitral prostheses due to the lack of left atrial acoustic interference.

Adult↗

Doppler assessment of prosthetic valves.

Doppler evaluation of prosthetic valves is a complex process involving assessment of both forward and regurgitant flow. It is important to consider the type of prosthesis, its size, its position, its relationship to the ultrasound beam, and the patient's cardiac output and afterload condition in any evaluation of prosthetic valve function.

Bioprosthesis↗

Tricuspid valve repair. Operative and follow-up evaluation by Doppler color flow mapping.

Severe tricuspid regurgitation may produce significant morbidity and mortality if not corrected, but commonly used methods of intraoperative assessment may be unreliable. Tricuspid regurgitation was evaluated by a new intraoperative technique, Doppler color flow mapping, in 85 patients before and after cardiopulmonary bypass. Regurgitation grade by intraoperative color Doppler mapping correlated well with right ventricular angiography (kappa value = 0.92, p less than 0.01; n = 8) and with preoperative color Doppler studies (kappa = 0.71, p less than 0.05; n = 51). The right atrial V wave correlated poorly with the severity of tricuspid regurgitation intraoperatively, both before (r = 0.30) and after (r = -0.05, p = no significant difference) cardiopulmonary bypass. Advanced (3+ or 4+) tricuspid regurgitation was found in 40% (21) of 52 patients requiring mitral valve repair or replacement. Tricuspid annuloplasty with a prosthetic ring provided a significant (greater than or equal to 2 grade) reduction in regurgitation severity in 94% (17/18; p less than 0.05). Without repair, tricuspid regurgitation decreased to a similar degree after mitral valve operations in 14% (5/36); only one of the five patients had advanced tricuspid regurgitation prepump. Fluid filling of the arrested right ventricle after the surgical procedure did not predict regurgitation severity (false negative rate 50%, 2/4; false positive rate 22%, 2/9). Regurgitation grade remained unchanged after the initial postpump study, up to 60 weeks postoperatively. In conclusion, color Doppler flow mapping provides more accurate intraoperative assessment of tricuspid regurgitation than the right atrial V wave or fluid filling of the right ventricle. This semiquantitative technique aids in the selection of patients appropriate for surgical repair of the tricuspid valve and is useful in judging the adequacy of tricuspid valve repair before chest closure. Advanced (3+ or 4+) tricuspid regurgitation is a common occurrence in patients undergoing mitral valve repair or replacement and rarely responds to conservative (nonoperative) management. Ring annuloplasty provides a highly effective and durable reduction in tricuspid regurgitation.

Adult↗

Use of the valvular resistance in the separation of normal and stenotic Hancock mitral valves.

Recent data suggests that the pressure-flow relationship for normal bioprosthetic mitral valves is linear. If this is correct, the valve resistance may provide a better indicator of normal mitral function than the Gorlin valve area. We compared the Gorlin valve area to the valve resistance (calculated as flow/pressure) in order to determine which better separated normal and stenotic Hancock mitral valves. Measurements were made using left atrial and left ventricular catheters in 42 patients undergoing Hancock mitral valve replacement. Patients were studied during pacing and isoproterenol infusion for a total of 141 measurements. Stenotic Hancock mitral valve hemodynamics were obtained at cardiac catheterization from eight patients who were studied at rest and during atrial pacing and from an additional eight patients culled from the literature (a total of 23 stenotic measurements). The Gorlin valve area ranged from 1.1 to 4.4 cm2 for the normally functioning Hancock valves and from 0.4 to 1.54 cm2 for the stenotic valves. Six measurements in patients with confirmed stenotic valves yielded Gorlin areas larger than the lowest area found in the normal valves and no value of the Gorlin valve area correctly classified all of the normal and the stenotic valves.(ABSTRACT TRUNCATED AT 250 WORDS)

Cardiac Catheterization↗

Reduction in sudden late death by concomitant revascularization with aortic valve replacement.

To determine the impact of coronary atherosclerosis and myocardial revascularization on survival after aortic valve replacement, we reviewed our experience with single aortic valve replacement between 1969 and 1984. Of 474 patients (mean age 62 +/- 13 years), 185 (39%) had no associated coronary artery disease, 233 (49%) had coronary artery bypass grafting, and 56 (12%) had unbypassed coronary artery disease. Early (30-day) mortality rates were 2.2%, 8.2%, and 7.1%, respectively (p less than 0.01, coronary disease absent versus present). Actuarial survival rates at 10 years were 77% +/- 4%, 41% +/- 6%, and 26% +/- 11% (p less than 0.001, coronary disease absent versus present), with 1 to 177 months of follow-up (mean 56 +/- 40). Preoperative angina (39%) did not predict the presence of coronary artery disease (61%). Multivariate logistic regression analysis showed that early deaths were associated with advanced preoperative New York Heart Association functional class (p less than 0.001), advanced age (p less than 0.05), more extensive coronary artery disease (p less than 0.05), and lack of cardioplegic myocardial protection (p less than 0.05). Complete revascularization did not increase operative risk when coronary artery disease was present (early mortality 6.8%, p = not significant). Late deaths were strongly associated with the presence of coronary artery disease (p less than 0.001) and reduced left ventricular ejection fraction (less than or equal to 55%, p less than 0.01). Late cardiac mortality was most commonly attributable to sudden death (30/71, 42%), especially in the unbypassed coronary disease cohort (9/14, 64%). The actuarial rate of freedom from sudden death at 10 years was 52% +/- 17% in the unbypassed coronary artery disease group (p = 0.009), compared with 90% +/- 3% and 91% +/- 3% in the revascularized and no coronary disease patients, respectively. Thus, coexistent coronary atherosclerosis has a detrimental impact on early and late survival after aortic valve replacement. Revascularization does not increase operative risk when associated coronary artery disease is present and significantly reduces the occurrence of late sudden death. Strategies that minimize operative risk when associated coronary artery disease is present include use of cardioplegia and complete revascularization.

Adolescent↗

Intraoperative Doppler color flow mapping for assessment of valve repair for mitral regurgitation.

The ability of color Doppler flow mapping to provide intraoperative information about mitral regurgitation (MR) severity and to evaluate adequacy of mitral valve repair was assessed by performing color Doppler echocardiography immediately before and after cardiopulmonary bypass, with the transducer placed directly on the epicardium. In 56 patients, the degree of MR by intraoperative color Doppler correlated well with left ventricular angiography (kappa = 0.80) and with closed-chest preoperative color Doppler (kappa = 0.84) and had good interobserver reproducibility (kappa = 0.88). Good correlation was also seen between closed-chest color Doppler and angiography (kappa = 0.75). After mitral valve repair in 18 patients (15 ischemic MR, 3 cleft valves), color Doppler was used to assess severity of residual MR intraoperatively and postoperatively. Intraoperative color Doppler identified satisfactory repair (MR less than or equal to 2+) in 15 patients and failure (MR greater than or equal to 3+) in 3, whereas conventional surgical assessment of MR by fluid filling of the arrested ventricle failed to provide reliable differentiation. MR severity on subsequent closed-chest color Doppler follow-up did not change significantly compared with intraoperative evaluation after repair. Intraoperative color Doppler provides accurate grading of MR severity, offers instantaneous evaluation of the adequacy of mitral valve repair before chest closure, and appears to predict the degree of postoperative MR seen on subsequent closed-chest follow-up studies.

Blood Flow Velocity↗

Comparison of esmolol and nitroprusside for acute post-cardiac surgical hypertension.

Because acute systemic hypertension early after cardiac surgery has been linked to catecholamine elevation, an open-label, randomized, crossover study was performed to compare the efficacy of esmolol, a new ultra-short-acting intravenous beta-blocking agent, to nitroprusside, the standard therapy. Controlled drug infusions to maximal dosage (esmolol, 300 micrograms/kg/min, and nitroprusside, 10 micrograms/kg/min) were titrated to achieve at least a 15% reduction in systolic pressure. The blood pressure (BP) endpoint was achieved with esmolol (within 29 +/- 14 minutes) in 18 of 20 patients (90%), compared with 19 of 20 (95%) with nitroprusside infusion (within 21 +/- 15 minutes, difference not significant [NS]). Systolic BP decreased from 170 +/- 13 to 136 +/- 12 mm Hg (mean +/- standard deviation) with esmolol and from 170 +/- 13 to 141 +/- 13 mm Hg with nitroprusside infusion (both p less than 0.05). Diastolic BP was reduced from 71 +/- 12 to 64 +/- 11 mm Hg with esmolol and from 71 +/- 12 to 52 +/- 13 mm Hg with nitroprusside infusion (both p less than 0.05). Esmolol infusion resulted in decreased heart rate, cardiac index and stroke volume index and increased right atrial pressure (all p less than 0.05), whereas nitroprusside infusion resulted in increased heart rate and cardiac index and decreased right atrial pressure, pulmonary arterial wedge pressure and systemic vascular resistance (p less than 0.05).(ABSTRACT TRUNCATED AT 250 WORDS)

Adrenergic beta-Antagonists↗