Search PubMed⌕ Search

Biomedical subjects

L R Snyder

Publications and source records attributed to L R Snyder.

At least 37 records · Page 2Linked to original sources

Computer simulation for the convenient optimization of isocratic reversed-phase liquid chromatographic separations by varying temperature and mobile phase strength.

Software is described which allows the rapid development of separations by means of isocratic reversed-phase liquid chromatography (RP-LC), based on the optimization of column temperature (T) and mobile phase strength (%B). For a given sample, four initial experiments are carried out at two different temperatures, using either isocratic or (better) gradient elution. If isocratic experiments are chosen for computer simulation, it is necessary to select appropriate values of %B for these initial runs. Literature data for solute retention as a function of T are reviewed, as a basis for estimating suitable values of %B at the two values of T selected. The use of optimized values of T and %B led to acceptable separations for three representative samples. The prediction of isocratic separation on the basis of initial gradient experiments is more convenient than the use of initial isocratic experiments, but less reliable. When gradient experiments are used, one additional isocratic experiment can improve the accuracy of such predictions by a "reflection" procedure. The latter approach was confirmed for predictions of both isocratic and gradient separation from initial gradient experiments.

Chromatography, Liquid↗

Control of column temperature in reversed-phase liquid chromatography.

When separations by reversed-phase liquid chromatography (RP-LC) are carried out at temperatures other than ambient, resulting retention times and bandwidths can depend on the equipment used. As a result, an RP-LC separation that is adequate when carried out on one LC system may prove inadequate when the separation is repeated on a second system. In the present study, various temperature-related problems which can result in a failure of method transfer for non-ambient RP-LC methods were examined. Means for correcting for such effects and thereby ensuring method transferability are described.

Chromatography, Liquid↗

Computer simulation for the simultaneous optimization of any two variables and any chromatographic procedure.

Computer software that allows the simulation of any chromatographic separation as a function of simultaneous changes in any one or two variables that can affect sample separation order (selectivity) is described. For one example, an application is described for the simultaneous variation of the mobile phase pH and gradient time in reversed-phase liquid chromatography. The accuracy of such predictions is examined for a sample mixture of 17 substituted benzoic acids and anilines, and requirements for an acceptable predictive accuracy are summarized. In a second example, the separation of three peptides by capillary electrophoresis is optimized.

Benzoates↗

Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time I. Peak capacity limitations.

The separation of samples that contain more than 15 to 20 analytes (n > 15-20) is typically difficult and usually requires gradient elution. We have examined the reversed-phase liquid chromatographic separation of 24 samples with 8 < or = n < or = 48 as a function of temperature T and gradient time tG. The required peak capacity was determined for each sample, after selecting T and tG for optimum selectivity and maximum sample resolution. Comparison of these results with estimates of the maximum possible peak capacity in reversed-phase gradient elution was used to quantify the maximum value of n for some required sample resolution (when T and tG have been optimized). These results were also compared with literature studies of similar isocratic separations as a function of ternary-solvent mobile phase composition, where the proportions of methanol (MeOH), tetrahydrofuran (THF) and water were varied simultaneously. This in turn provides information on the relative effectiveness of these two different method development procedures (optimization of T and tG vs. % MeOH and % THF) for changing selectivity and achieving maximum resolution.

Chromatography, Liquid↗

Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time III. Improving the accuracy of computer simulation.

Previous studies have shown that four experimental runs, where both temperature T and gradient time tG are varied, can be used for the reliable prediction of separation as a function of these two variables (two-dimensional optimization). Computer simulation (e.g., DryLab) can then be used to predict "optimized" conditions for maximum sample resolution using either isocratic or gradient elution. Samples that contain a large number of components (e.g., n>15-20) present a greater challenge. Resolution for these more complex samples is often quite sensitive to small changes in T or tG in turn requiring greater accuracy in predictions that result from computer simulation. In the present study of several samples, we have examined computer simulation errors that can arise from inexact expressions for retention time as a function of T, tG or isocratic %B. Resulting conclusions are applicable to both complex and simpler samples, in either one- or two-dimensional optimization. Means to anticipate and minimize the impact of these predictive errors are examined.

Chromatography, Liquid↗

Reversed-phase liquid chromatographic separation of complex samples by optimizing temperature and gradient time II. Two-run assay procedures.

By optimizing column temperature T and gradient time tG, complex samples can often be separated by means of reversed-phase high-performance liquid chromatography (RP-LC). Conclusions reached in Part I suggest that the complete separation of such samples will be difficult, however, when more than 15-20 components are present in the sample. An alternative approach is to carry out two separations with different conditions (T, tG) in each run. The combination of results from these two runs then allows the total analysis of the sample, providing that every sample component is adequately resolved in one run or the other. Examples of this approach, carried out by means of computer simulation, are shown here for several samples of varying complexity. Also considered is the ability of a single separation where T and tG are optimized to enable the separation and analysis of one or more individual sample components from complex mixtures (e.g., drugs in animal plasma), including the resolution of isomeric compounds from each other.

Chromatography, Liquid↗

Simultaneous variation of temperature and gradient steepness for reversed-phase high-performance liquid chromatography method development. I. Application to 14 different samples using computer simulation.

The optimized reversed-phase HPLC separation of 14 different samples is reported, based on simultaneous changes in temperature and gradient steepness. Four experimental runs are required for each sample, following which preferred conditions can be predicted using computer simulation software (DryLab). The overall accuracy and effectiveness of this method development approach is discussed, with particular attention to the use of resolution maps provided by the software. These maps are useful for maximizing resolution for the total sample, for optimizing the separation of a smaller number of selected sample compounds, and as an initial step in the separation of more demanding samples.

Adrenal Cortex Hormones↗

Simultaneous variation of temperature and gradient steepness for reversed-phase high-performance liquid chromatography method development. II. The use of further changes in conditions.

The preceding paper (Part I) suggests that simply optimizing temperature and gradient steepness will often provide an adequate reversed-phase HPLC separation. In some cases, however, this procedure will prove unsuccessful, and then further method-development experiments (involving change in other separation conditions) will be required. One strategy is to change a variable other than temperature or gradient steepness, followed by re-optimization of the latter two variables. The present paper examines the application of this approach with the aid of computer simulation to several samples.

Acetonitriles↗

Maintaining fixed band spacing when changing column dimensions in gradient elution.

In gradient elution separations, it may be required to change either column length (to increase resolution or shorten run time) or column diameter (for an increase in sensitivity or for preparative separations). In either of these changes of column dimensions, it is usually desired to maintain the same relative band spacing (selectivity), so as to increase resolution in proportion to (column plate number)1/2 when increasing column length, or to maintain constant resolution when changing column diameter. A general rule for avoiding changes in band spacing in these situations is to maintain the quantity [(gradient time) x (flow-rate)/(column volume)] constant, while holding the initial and final gradient mobile phase compositions (%B) fixed. This rule is only valid as long as the equipment hold-up volume (dwell volume) is negligible, or if all sample components are strongly retained at the start of the gradient. When neither of the latter conditions apply, then significant changes in band spacing may result when changing column size. Rules are presented for recognizing this potential problem for a given sample/HPLC-equipment combination, and adjustments in separation conditions that can avoid this problem are discussed. Changes in band spacing as a result of change in column size are of special concern when developing procedures for preparative chromatography under gradient conditions.

Chromatography, High Pressure Liquid↗

Changing reversed-phase high performance liquid chromatography selectivity. Which variables should be tried first?

When carrying out HPLC method development, it is often necessary to vary the relative retention of the sample (values of alpha) by changing some experimental variable, e.g., solvent type, pH, etc. The choice of which variable will be most suitable for a change in selectivity depends on two conflicting goals: (a) the attainment of maximum changes in alpha for the better control of resolution and (b) the avoidance of practical problems associated with the use of a given variable to optimize selectivity. This study provides a quantitative evaluation of different variables for their effect on selectivity (alpha). Various practical problems which must be balanced against this ability of a variable to change value of alpha are also discussed. The selection of any two variables for their simultaneous use in controlling alpha is also examined.

Chromatography, High Pressure Liquid↗

Combined use of temperature and solvent strength in reversed-phase gradient elution. I. Predicting separation as a function of temperature and gradient conditions.

It has been shown previously that computer simulation based on two initial experiments can predict separation in reversed-phase gradient elution as a function of gradient conditions (gradient steepness, gradient range and gradient shape) and column conditions (column length, flow-rate and particle size). The present study extends this capability for changes in temperature. Four initial experiments (two different gradient times, two different temperatures) provide input data that allow predictions of separation as a function of temperature as well as gradient and column conditions. A semi-empirical relationship, tR = a + bT, is able to relate gradient retention time tR to column temperature T (other conditions constant). The accuracy of this approach has been evaluated for 102 solutes and a variety of experimental conditions, including the use of five different HPLC instruments (four different models).

Chromatography, High Pressure Liquid↗

Temperature as a variable in reversed-phase high-performance liquid chromatographic separations of peptide and protein samples. I. Optimizing the separation of a growth hormone tryptic digest.

Peptide and protein samples are often complex mixtures that contain a number of individual compounds. The initial HPLC separation of such samples typically results in the poor resolution of one or more band pairs. Various means have been suggested for varying separation selectivity so as to minimize this problem. In this study of a tryptic digest of recombinant human growth hormone, the simultaneous variation of temperature and gradient steepness was found to be a convenient and effective means of varying selectivity and optimizing the separation. The use of computer simulation greatly facilitated this investigation.

Chromatography, High Pressure Liquid↗

Temperature as a variable in reversed-phase high-performance liquid chromatographic separations of peptide and protein samples. II. Selectivity effects observed in the separation of several peptide and protein mixtures.

Changes in band spacing as a function of temperature and/or gradient steepness were investigated for four peptide or protein samples. Reversed-phase HPLC in a gradient mode was used to separate tryptic digests of tissue plasminogen activator and calmodulin. Additionally, a synthetic peptide mixture and a storage protein sample from wheat were studied. Simultaneous changes in gradient steepness and temperature were found to provide considerable control over band spacing and sample resolution. The effects of temperature and gradient steepness on selectivity in these systems appear to be complementary. Simultaneous optimization of both temperature and gradient steepness thus represents a powerful and convenient means of controlling band spacing and separation. Because of the complexity of these sample chromatograms, computer simulation proved to be a useful tool in both interpreting these experiments and in optimizing final separations.

Calmodulin↗

Computer simulation as a tool for the rapid optimization of the high-performance liquid chromatographic separation of a tryptic digest of human growth hormone.

Computer simulation was used to optimize the separation of a tryptic digest of recombinant human growth hormone using reversed-phase high-performance liquid chromatography in a gradient mode. DryLab G/plus software modelled the retention behavior of the complex tryptic digest mixture as a function of gradient conditions, based on data from two experimental gradient runs. The theoretical optimum separation conditions were rapidly obtained and reproduced experimentally. Resolution did not simply increase as gradient steepness was decreased, rather, an intermediate gradient time provided maximum sample resolution. The simulation results also indicate that the method is reasonably rugged, with little change in the separation expected for different high-performance liquid chromatography systems, and changes in the separation can be compensated by a change in the gradient steepness. Computer simulation can also be useful to quickly reoptimize conditions for a new column, if it fails to provide the same separation.

Chromatography, High Pressure Liquid↗

Computer simulation for the prediction of separation as a function of pH for reversed-phase high-performance liquid chromatography. I. Accuracy of a theory-based model.

Computer simulation software (DryLab I/mp) is described for predicting high-performance liquid chromatographic separation as a function of changes in mobile phase pH. Three experimental runs with pH (only) varied are used to derive values of pKa plus capacity factors (k') for the ionized and non-ionized form of each ionizable solute. Various tests of the experimental data then allow classification of each solute as acidic, basic, neutral (including strong or weak acids or bases) and amphoteric. Experimental data are reported for the separation of several substituted anilines as a function of pH and solvent composition (%B). Experimental requirements for the accurate prediction of separation (ca. +/- 2-4% in alpha) as a function of pH are discussed. The reliability of the software is demonstrated for three different samples: mixtures of (a) substituted benzoic acids, (b) substituted anilines and (c) catecholamine-related compounds.

Aniline Compounds↗

Computer simulation for the prediction of separation as a function of pH for reversed-phase high-performance liquid chromatography. II. Resolution as a function of simultaneous change in pH and solvent strength.

The optimization of reversed-phase high-performance liquid chromatographic separation by the simultaneous variation of pH and solvent strength (%B) was studied for acidic (substituted benzoic acids) and basic samples (substituted anilines). The combination of these two variables was expected to be more useful than either variable alone. This proved to be the case for the benzoic acid sample, but not for the aniline sample. Column plate numbers were also studied for each sample and as a function of pH. With the exception of one compound (3,5-dimethylaniline) in one particular pH range (3.0-4.5), plate numbers of 12,000-20,000 were observed for each sample.

Aniline Compounds↗

The use of a computer to select optimized conditions for high-performance liquid chromatography separation.

Computer simulation allows the convenient prediction and optimization of HPLC separation as a function of various separation conditions. The use of retention and bandwidth relationships that have been validated for a broad range of chromatographic systems minimizes the number of experimental runs needed, especially for the new technique of restricted multi-parameter optimization. The chromatographer is free to use these procedures in a trial-and-error mode, or alternatively use can be made of resolution maps and other data summaries. "Gridding" experiments, based on the automated collection of chromatographic data, can be used to supplement predictions obtained from computer simulation.

Chemistry Techniques, Analytical↗