Search PubMed⌕ Search

Biomedical subjects

L R Guterman

Publications and source records attributed to L R Guterman.

At least 55 records · Page 3Linked to original sources

Efficacy and current limitations of intravascular stents for intracranial internal carotid, vertebral, and basilar artery aneurysms.

OBJECT: Results of previous in vitro and in vivo experimental studies have suggested that placement of a porous stent within the parent artery across the aneurysm neck may hemodynamically uncouple the aneurysm from the parent vessel, leading to thrombosis of the aneurysm. For complex wide-necked aneurysms, a stent may also aid packing of the aneurysm with Guglielmi detachable coils (GDCs) by acting as a rigid scaffold that prevents coil herniation into the parent vessel. Recently, improved stent system delivery technology has allowed access to the tortuous vascular segments of the intracranial system. The authors report here on the use of intracranial stents to treat aneurysms involving different segments of the internal carotid artery (ICA), the vertebral artery (VA), and the basilar artery (BA). METHODS: Ten patients with intracranial aneurysms located at ICA segments (one petrous, two cavernous, and three paraclinoid aneurysms), the VA proximal to the posterior inferior cerebellar artery origin (one aneurysm), or the BA trunk (three aneurysms) were treated since January 1998. In eight patients, stent placement across the aneurysm neck was followed (immediately in four patients and at a separate procedure in the remaining four) by coil placement in the aneurysm, accomplished via a microcatheter through the stent mesh. In two patients, wide-necked aneurysms (one partially thrombosed BA trunk aneurysm and one paraclinoid segment aneurysm) were treated solely by stent placement; coil placement may follow later if necessary. No permanent periprocedural complications occurred and, at follow-up examination, no patient was found to have suffered symptoms referable to aneurysm growth or thromboembolic complications. Greater than 90% aneurysm occlusion was achieved in the eight patients treated by stent and coil placement as demonstrated on immediate postprocedural angiograms. Follow-up angiographic studies performed in six patients at least 3 months later (range 3-14 months) revealed only one incident of in-stent stenosis. In the four patients originally treated solely by stent placement, no evidence of aneurysm thrombosis was observed either immediately postprocedure or on follow-up angiographic studies performed 24 hours (two patients), 48 hours, and 3 months later, respectively. CONCLUSIONS: A new generation of flexible stents can be used to treat complex aneurysms in difficult-to-access areas such as the proximal intracranial segments of the ICA, the VA, or the BA trunk. The stent allows tight coil packing even in the presence of a wide-necked, irregularly shaped aneurysm and may provide an endoluminal matrix for endothelial growth. Although convincing experimental evidence suggests that stent placement across the aneurysm neck may by itself promote intraluminal thrombosis, the role of this phenomenon in clinical practice may be limited at present by the high porosity of currently available stents.

Adult↗

Successful intracranial thrombolysis for cerebral thromboembolic complications resulting from cardiovascular diagnostic and interventional procedures.

We report successful local thrombolysis to treat intracranial ischemic complications of angioplasty with stenting of a high-grade carotid artery stenosis, angioplasty with thrombolysis of an occluded venous graft, and routine coronary angiography. Intracranial complications occurring during cardiovascular diagnostic or interventional procedures can be reversed with prompt management via rescue thrombolysis. These events should not be viewed as irreversible complications, and the opportunity for intracranial thrombolysis should be available wherever cardiovascular interventional procedures are performed. The ability to quickly recognize and remedy complications occurring during these procedures is another step in the continued advancement of neuroendovascular therapy.

Aged↗

Angioplasty and stenting for carotid artery stenosis: indications, techniques, results, and complications.

Following the favorable results obtained in the treatment of coronary artery disease, combined angioplasty and stenting has been advocated for the treatment of carotid artery stenosis as well. Although widespread application of angioplasty and stenting for carotid artery disease is neither indicated nor recommended, it may be a viable alternative therapy for select patients who are high-risk patients for surgery. The results of early series have suggested that endoluminal revascularization in these high-risk patients can be performed with an acceptable degree of safety. Although the incidence of death and major stroke rates following angioplasty and stenting procedures compares favorably with surgery, results of more recent clinical series have suggested that the incidence of perioperative transient neurological events and minor strokes may be higher than suggested by earlier reports, especially in patients with recent neurological symptoms and "unstable" plaques. In this article, the authors review the current potential indications for and preliminary results of angioplasty and stenting and describe their procedural technique. In addition, potential applications of stenting to intracranial thromboocclusive carotid artery disease are reviewed.

Journal Article↗

Stent placement for vertebral artery occlusive disease: preliminary clinical experience.

Symptoms of vertebrobasilar insufficiency may precede neurological sequelae in up to 50% of patients. Although select patients may benefit from microsurgical revascularization, combined perioperative morbidity and mortality rates can be as high as 20%. The authors present their preliminary clinical experience using stent placement for symptomatic vertebral artery (VA) occlusive disease. Six patients with clinical symptoms of vertebrobasilar insufficiency in whom VA stents were placed from 1995 to 1998 were identified. Diagnostic four-vessel cerebral angiography identified causative stenotic, atherosclerotic lesions in all cases. A transfemoral or transradial artery approach after the patient had undergone full heparinization was chosen for endovascular stenting. Guidewire placement across the lesion followed by urokinase infusion preceded stenting. Prestent angioplasty was performed in two patients. Following the procedure, all patients were maintained on daily antiplatelet therapy. Patient age ranged from 45 to 76 years (average 63 years). Four patients were men and two were women. Angiography revealed greater than 95% stenosis in five patients and greater than 70% stenosis in one. Three patients had complete occlusion of the contralateral VA; in one other, the VA supplied only the posterior inferior cerebellar artery; and the remaining two patients had VAs with greater than 70% stenosis. Ten stents were placed in six patients for five VA origin lesions and one distal VA stenosis. A VA dissection occurring poststenting was treated by placement of three additional stents. One patient had transient double vision. All had resolution of their presenting symptoms. Follow up ranged from 1 to 24 months (average 8.4 months). Angiograms obtained in four patients at least 3 months postprocedure have revealed stent patency in all cases without evidence of restenosis. Vertebral artery stent placement can be safely performed and is a viable treatment option for carefully selected patients with vertebrobasilar insufficiency.

Journal Article↗

Saccular aneurysm induction by elastase digestion of the arterial wall: a new animal model.

OBJECTIVE: To develop a rabbit aneurysm model that is more realistic in gross appearance and histological features than previous models and to enable the development of a larger animal model. METHODS: Ten rabbits received porcine pancreatic elastase, five at the right common carotid artery bifurcation and five others at the right superior thyroid artery origin. One control animal received collagenase and another received papaverine, each at the right superior thyroid artery origin. The agents were topically delivered to the arterial adventitia with a microsyringe after surgical exposure of the targeted arteries. The arteries were monitored for aneurysm growth with a video camera for up to 3 hours and were then removed and processed for histology. RESULTS: Saccular aneurysms developed in one of five animals after elastase application at the carotid bifurcation and in all five animals receiving elastase at the superior thyroid artery origin. Among the six aneurysms, recurrent minor hemorrhages occurred in four, thrombosis of the aneurysm sac in three, and rupture causing severe bleeding in one. Histological sections revealed thin-walled aneurysms composed only of collagen fibers and some cellular elements. No saccular dilation resulted from papaverine application. Collagenase application resulted in a hemorrhagic-thrombotic lesion in the arterial wall but no aneurysm formation. CONCLUSION: Arterial saccular aneurysms were induced in rabbits by topical application of elastase with an easy and efficient method. These aneurysms are histologically similar to natural aneurysms, and their arterial nature renders them more authentic than those of surgical models. This aneurysm model may serve as a foundation for further aneurysm research.

Animals↗

Stenting and secondary coiling of intracranial internal carotid artery aneurysm: technical case report.

OBJECTIVE AND IMPORTANCE: Endovascular stents have been successfully used in the treatment of fusiform and dissecting aneurysms of the peripheral circulation and extracranial carotid and vertebral arteries. Technical limitations related to the inability to navigate the stent and the delivery system through tortuous vascular segments has limited their application with intracranial lesions. Availability of new flexible and pliable stent systems might overcome these difficulties. CLINICAL PRESENTATION: A 49-year-old woman presented with a dissecting pseudoaneurysm of the horizontal portion of the petrous internal carotid artery that increased in size, as revealed by serial angiographic studies. INTERVENTION: The aneurysm was treated by deploying a new flexible stent across the aneurysm neck and by then packing the aneurysm sac with Guglielmi detachable coils that were delivered by a microcatheter positioned through the stent struts into the aneurysm lumen. CONCLUSION: New flexible stents can be used to treat intracranial internal carotid artery aneurysms in difficult-to-access areas, such as the horizontal petrous segment. The stent may disrupt the aneurysm inflow tract, thereby inducing stasis and facilitating intra-aneurysmal thrombosis. In addition, the stent acts as an endoluminal scaffold to prevent coil herniation into the parent artery, which allows tight packing of even wide-necked and irregularly shaped aneurysms. The stent may also serve as a matrix for endothelial growth. We think this new generation of flexible stents and the use of this described technique will usher in the next era of endovascular management of intracranial aneurysms.

Aortic Dissection↗

Delayed aneurysm regrowth and recanalization after Guglielmi detachable coil treatment. Case report.

Guglielmi detachable coil (GDC) treatment for complicated cerebral aneurysms is an attractive option that has become widely accepted in recent years. This technique is usually considered only if the patient harbors an aneurysm that is not a good candidate for surgical clipping. However, the definition of "surgical candidate" varies among institutions, and many patients worldwide are being treated with GDCs as primary therapy. Although most centers currently perform follow-up angiography at 6 months to 1 year, others do not routinely perform it after an initially good result. The authors present a case that indicates longer follow up may be necessary and illustrates some of the pitfalls of GDC treatment. This 56-year-old man presented to the emergency room with a Hunt and Hess Grade II subarachnoid hemorrhage and was found to have a wide-necked basilar apex aneurysm. Because of associated medical comorbidities, it was decided to treat the aneurysm with endovascular techniques. The patient did well on follow-up angiography at 1 year postprocedure. However, at approximately 2 years follow up, the aneurysm was demonstrated to have dramatically recanalized and regrown, requiring open surgical intervention. Endovascular coiling was insufficient to treat this aneurysm and complicated definitive surgical management because a large coil mass had been placed in the operative field. It can be inferred from this case that angiographic follow up of these types of lesions may be beneficial up to 2 years after GDC treatment.

Basilar Artery↗

Cavernous sinus syndrome during balloon test occlusion of the cervical internal carotid artery. Report of two cases.

The authors report the occurrence of ipsilateral transient cavernous sinus syndrome during balloon test occlusion (BTO) of the cervical internal carotid artery (ICA) and discuss the involved pathomechanisms. The authors reviewed their series of 129 BTOs of the ICA performed between 1989 and 1996. Two patients developed facial paresthesias and transient palsies of the third through sixth cranial nerves during test occlusion of the cervical ICA. The tests were performed prior to planned permanent carotid artery occlusion for the treatment of a neck sarcoma in one patient and a giant cavernous carotid artery aneurysm in the other. The patients' symptoms resolved with deflation of the balloon. When the balloon was subsequently inflated above the inferior cavernous sinus artery (ICSA), one of the patients complained of mild facial discomfort. There was no contralateral weakness or mental status change during test occlusion in either patient. Angiography demonstrated good filling of the ipsilateral intracranial circulation via collateral vessels of the circle of Willis. In these two cases, the cranial nerves in the cavernous sinus were likely supplied by the ICA via the meningohypophyseal trunk and the ICSA. In each case, there was excellent blood supply to the ipsilateral cerebral hemisphere; however, there was probably inadequate retrograde filling of the cranial nerve collateral vessels located where the meningohypophyseal trunk and ICSA originated. These cases emphasize the importance of a patent external carotid artery-ICA connection for successful cervical carotid artery occlusion. Neurological examination during BTO was critical to interpret the clinical manifestations caused by the hemodynamic changes.

Abducens Nerve↗

Rapid saccular aneurysm induction by elastase application in vitro.

OBJECTIVE: To develop a new saccular aneurysm model in vitro using elastase to study aneurysm initiation, growth, and rupture and to create a new in vivo aneurysm model to test endovascular therapies. METHODS: Seventeen common carotid arteries excised from freshly killed pigs and sheep were treated with seven different methods of elastase delivery. The arteries were mounted in a saline-filled flow chamber. They received pulsatile flow for 48 hours, or until the resulting aneurysms ruptured. Changes were continuously monitored with video camera recordings and validated with histological sections. RESULTS: All eight arteries treated topically, either on the intimal or on the adventitial surface, with elastase concentrations greater than 1 U/mm2, developed saccular aneurysms; five of them ruptured within 48 hours. All four arteries treated with surface concentrations of 0.1 U/mm2 via microcatheter infusion into the lumen developed fusiform aneurysms. None of the arteries that received surface concentrations less than 0.1 U/mm2 developed aneurysms. Histological sections revealed a reduced number of cellular element in a stretched collagen matrix at the dome of the saccular aneurysms. CONCLUSION: After empirically testing several methods of elastase delivery, we were able to induce saccular, bifurcation-type aneurysms in animal arterial specimens. These aneurysms are histologically similar and more authentic than surgical models. The procedure is easy and reproducible. Our results suggest a possible enzymatic role in aneurysm formation and highlight the dramatic effects of selective arterial elastic damage. Also, the rapid growth of our experimental aneurysms may reflect the speed of the natural process.

Aneurysm, Ruptured↗

Temporary balloon protection as an adjunct to endosaccular coiling of wide-necked cerebral aneurysms: technical note.

OBJECTIVE: We present an endovascular technique for treating wide-necked cerebral aneurysms using Guglielmi detachable coils (Target Therapeutics, Fremont, CA) and simultaneous temporary balloon protection. The temporary balloon serves as a mechanical external force to mold the microcoils away from the parent artery. METHODS: Two illustrative cases of wide-necked cerebral aneurysms treated with Guglielmi detachable coils and a temporary balloon are presented. Emphasis is placed on the technical aspects of the approach, with several variations. The first case involves a left posterior cerebral artery aneurysm at the P1/P2 segment, and the second case involves a left paraclinoid internal carotid artery aneurysm. Both patients suffered from subarachnoid hemorrhage, but neither was a candidate for craniotomy. In each case, the coils, when used alone, protruded into the parent artery and were therefore removed. Then a temporary balloon was inflated for mechanical protection during coil deployment. RESULTS: The use of simultaneous temporary balloon protection allowed more dense intra-aneurysmal coil packing, especially in the neck, without parent artery compromise, than did the use of Guglielmi detachable coils alone. CONCLUSION: Endovascular treatment of wide-necked cerebral aneurysms can be facilitated by simultaneous temporary balloon protection.

Aneurysm, Ruptured↗

Initial experience with collagen-filled Guglielmi detachable coils for endovascular treatment of experimental aneurysms.

PURPOSE: To evaluate the effectiveness of Guglielmi detachable coils (GDCs) filled with collagen threads in the permanent treatment of experimental aneurysms. METHODS: Seventeen side-wall aneurysms were surgically constructed in the canine common carotid artery; six were treated with conventional GDCs and 11 with collagen-filled GDCs. One aneurysms was removed at 1 week, the others were studied by digital subtraction angiography for a period of 8 to 12 weeks. Longitudinal sections of all aneurysms were examined by light microscopy. RESULTS: Angiograms obtained throughout the follow-up period showed no significant difference between aneurysms treated with conventional GDCs and those treated with collagen-filled GDCs. Light microscopy revealed a dense meshwork of newly formed collagen and fibroblasts near the collagen-filled GDCs, whereas a loose cellular meshwork surrounded the conventional GDCs at 8 and 12 weeks after treatment. CONCLUSION: Collagen threads within GDCs do not noticeably improve angiographic treatment of experimental aneurysms; however, these threads did induce local proliferation of fibroblasts and production of collagen within the aneurysmal cavities.

Aneurysm↗

Endovascular treatment of experimental aneurysms with liquid polymers: the protective potential of stents.

Liquid polymers have previously been used to treat experimental and human aneurysms. However, the delivery of a liquid embolic material into the cerebral circulation involves a high risk of irreversible vessel occlusion and stroke. To evaluate methods for the safe and effective treatment of experimental aneurysms with liquid polymer injection, we tested four different techniques to deliver cellulose acetate polymer (CAP) or N-hexyl-cyanoacrylate into canine side-wall carotid artery aneurysms. The animals were observed for 1 to 10 weeks after treatment. Two aneurysms were treated without protection of the distal circulation, one with CAP and another with N-hexyl-cyanoacrylate. In four cases, an angioplasty balloon was inflated within the parent artery during endosaccular injection of CAP. In two of these cases, the balloon was placed adjacent to the aneurysm orifice, resulting in simultaneous occlusion of both the aneurysm and the parent artery, and in the other two cases, the balloon was positioned proximal to the aneurysm, resulting in temporary flow arrest. Three aneurysms were treated with either CAP or N-hexyl-cyanoacrylate after implantation of a balloon-expandable tantalum stent within the parent artery across the aneurysm orifice. Complete angiographic obliteration was achieved in all but one case. One aneurysm ruptured. Another partially occluded aneurysm reopened 10 weeks after treatment. In all cases treated without stents, distal migration of the polymer resulted in either stenosis or occlusion of the parent arteries. The combination of stent implantation and polymer injection resulted in permanent aneurysm occlusion without detectable polymer migration. An intravascular stent deployed within the parent artery across the aneurysm orifice acted as a safety net during endosaccular polymer injection by allowing blood to flow from the aneurysm cavity while preventing distal migration of liquid polymer.

Aneurysm↗

Clinical application of region-of-interest techniques to radiologic imaging.

In region-of-interest (ROI) imaging, a filter with a central aperture is used to substantially reduce patient dose outside of an ROI while maintaining or improving image quality within the ROI. The benefits of ROI imaging can be realized by using standard imaging equipment. ROI imaging has been clinically applied to gastrointestinal radiology and interventional procedures. In gastrointestinal procedures, ROI fluoroscopy without image processing can be used without adversely affecting the procedure or interfering with spot radiography. ROI fluoroscopy can reduce the dose-area product by a factor of 1.7 for gastrointestinal procedures. In interventional neuroradiologic procedures, equalized display brightness is achieved with road mapping during fluoroscopy and with standard digital subtraction techniques during angiography. In interventional radiology, ROI filters can generally reduce the patient skin dose to levels below the threshold for skin effects, thus eliminating these effects across more than 85% of the field of view.

Central Nervous System↗

Application of region-of-interest imaging techniques to neurointerventional radiology.

To reduce radiation exposure to patients and staff during neurointerventional procedures, region-of-interest (ROI) techniques were used with fluoroscopy, road mapping, and digital subtraction angiography in 19 patients. ROI filters, made of multiple layers of gadolinium, were attached to the collimators. Patient skin exposure was reduced by a factor of 3.3-10.0 across 85% of the field of view, and exposures were reduced to below thresholds for skin effects.

Angiography, Digital Subtraction↗

Vascular neurosurgery: aneurysms, arteriovenous malformations, subarachnoid hemorrhage, and intracranial hemorrhage.

Cerebrovascular disease continues to be a major source of morbidity and mortality in our aging population. Endovascular therapy for the treatment of cerebral aneurysms and associated vasospasm is gaining credibility. Some arteriovenous malformations considered inoperable in the past can now be successfully treated using multimodality therapy. Quantitative measurement of cerebral blood flow is helping to identify patients at risk of ischemic events and defining new guidelines for intervention. New noninvasive imaging modalities may replace conventional angiography for surgical disease. Advances in technology continue to improve our ability to treat cerebrovascular disease prior to irreversible ischemic events.

Cerebral Hemorrhage↗

Thrombolysis of the cervical internal carotid artery before balloon angioplasty and stent placement: report of two cases.

The application of endovascular techniques to the treatment of cervical carotid artery bifurcation atherosclerosis has been delayed because of the fear of causing embolic events while traversing the diseased portion of the artery with an angioplasty balloon catheter. Symptomatic carotid arteries often contain fresh or partially digested intraluminal thrombus. Before we cross certain carotid bifurcation lesions with angioplasty catheters, we deliver 100,000 to 200,000 units of urokinase in an attempt to digest loose thrombus. We have witnessed changes in the angiographic appearance of the diseased portion of the vessel after urokinase treatment, such as widening of the lumen, that suggest clot lysis. We present two patients who had symptomatic internal carotid artery stenosis. Angiography showed irregular narrowing of the internal carotid artery origin. One patient was selected for angioplasty instead of carotid endarterectomy because of severe cardiac risk factors. The other patient had major angiographic risk factors manifested by poor collateral circulation. The angiographic findings and history of transient ischemic attacks led us to suspect the presence of soft, loose plaque debris or thrombus in both cases. Therefore, we performed thrombolysis with urokinase before angioplasty. Repeat angiography showed widening of the arterial lumen and smoothing of the plaque profile. Subsequent angioplasty and stent placement were uneventful. Intraarterial thrombolysis can produce a change in the angiographic appearance of symptomatic atherosclerotic lesions of the cervical carotid artery bifurcation. Digestion of intralesional thrombus may provide a safer environment for deployment of endovascular remodeling devices by decreasing the likelihood of embolic phenomena. We believe thrombolysis should be done before angioplasty in select patients.

Aged↗

Delayed recanalization of a cerebral arteriovenous malformation following angiographic obliteration with polyvinyl alcohol embolization.

BACKGROUND: The efficacy of embolization of cerebral arteriovenous malformations (AVMs) is presently being evaluated. Embolization of single pedicle AVMs may produce complete angiographic obliteration and has been suggested as the sole therapy for treating these lesions. METHODS: A 17-year-old female presented with a left intraventricular and intraparenchymal cerebral hemorrhage resulting from a 1 cm left posterior choroidal AVM. She subsequently underwent polyvinyl alcohol (PVA) embolization of the AVM with complete angiographic obliteration. RESULTS: At 9 months follow-up, no evidence of recanalization of the AVM nidus was seen. Two years later, recanalization of the nidus was seen; and the patient received radiosurgical treatment. The natural history of previously embolized AVMs is reviewed and the mechanisms for recanalization are discussed. CONCLUSION: We recommend that patients with angiographic obliteration of AVMs receive further treatment, preferably resection, or be followed with serial angiography.

Adolescent↗