[Hodgkin's disease with hepatic manifestation].
Explore the source record for details and available documents.
Biomedical subjects
Publications and source records attributed to L Pinchuk.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Work reported here shows that, contrary to reports in the literature, hydrogels made from pure poly(2-hydroxyethyl methacrylate), pHEMA, at crosslinker content greater than 0.15 mol % do not swell above the usual equilibrium values of 39-42% water content in aqueous urea solution. However, hydrogels containing small (impurity) amounts of methacrylic acid (MAA) do swell dramatically (approximately 90%) in dilute urea solution, but not directly due to the urea. The urea decomposes to produce ammonium ions, thus raising the pH of the solution. Ionization of MAA occurs above pH 6, causing electrostatic interactions within the gel. The grossly swollen state of these gels represents an internal equilibrium among forces due to rubber elasticity, polymer-polymer/solvent affinity, and electrostatic interactions.
Approximately 50,000 abdominal aortic aneurysms (AAAs) are surgically repaired annually in the United States. Endovascular grafts (EVGs) combine a stent and a vascular graft offering great potential for reduced morbidity, mortality, and hospital stay because of minimally invasive endoluminal placement through catheters. Because most AAAs extend into one or both iliac arteries, a bifurcated EVG (bEVG) was developed, consisting of a proximal aortic trunk divided into two distinct lumens or sockets to receive two smaller diameter leg (iliac) components. All components were composed of Didcott self-expanding braided wire stents integrally attached to porous spun polycarbonate urethane liners. Successful placement of the bEVGs (trunks 10-12 mm and legs 5-6 mm diameter) by a 10 Fr introducer through the femoral arteries into the infrarenal aorta and external iliac arteries of 9 of 11 dogs was achieved. Subsequently, 11 of 12 bEVGs were successfully placed to exclude a saccular aneurysm exceeding three aortic diameters created by a fascia lata pouch extending from the aorta into the left external iliac artery, of which 7 were patent at 1 to 4 months. These findings establish design feasibility of the bEVG as well as the utility of the canine experimental model.
Polyurethane vascular prostheses offer the potential of superior thromboresistance and reduced anastomotic hyperplasia compared to existing Dacron and ePTFE alternatives, but have suffered from susceptibility to biodegradation, with resulting mechanical failure. To address this problem, the authors have developed and evaluated a composite prosthesis comprised of: 1) an inner blood interfacing elastomeric porous membrane made from Corethane, a proprietary Shore 80A polyurethane like material substantially devoid of ether/ester linkages, with superior biostability over conventional polyether urethanes, spun into a nonwoven structure with fiber diameters 10-15 microns and pore sizes 30-60 microns filled with gelatin +/- heparin; and 2) an outer soft, tissue interfacing, warp knitted Dacron mesh bonded to the inner layer to assure long-term dimensional stability. Twenty 4 mm ID x 5 cm L composite prostheses, half with heparinized gelatin (the remainder nonheparinized) were implanted as femoral interposition grafts in 10 dogs. Four of the 10 nonheparinized grafts occluded. All 10 with heparin remained widely patent, with two explanted at 6 months showing vascularized connective tissue growth through the graft, in contrast to the giant cell inflammatory response to the Dacron mesh, with a substantially endothelialized neointima and no Corethane biodegradation. Of the 10 patent grafts at 1 year follow-up, none showed aneurysm formation. This vascular prosthesis provides compliance superior to ePTFE and Dacron alternatives, with excellent suture retention and good kink resistance, while combining the superior thromboresistance and tissue ingrowth properties of polyurethanes with the proven biostability of Dacron.
We have developed a composite vascular prosthesis with the inner blood interfacing layer made of a porous elastomeric membrane of spun Corethane fibers (10-15 microns in diameter, pore size 30-60 microns) impregnated with a gelatin-heparin complex and an outer soft tissue interfacing warp knitted Dacron sheath. Forty-eight Corethane/Dacron composite (CDC) vascular grafts, 4 mm in diameter and 5 cm in length, and 48 expanded polytetrafluoroethylene (ePTFE) vascular grafts of similar size were implanted bilaterally as end to end interposition grafts on opposite sides in the carotid and femoral arteries in dogs on low dose (162 mg/day) aspirin. Patency at 3 months was 37/48 (77%) for the ePTFE grafts and 44/48 (91.7%) for the CDC grafts. Fisher's exact test (two-tailed comparison) indicates the probability of superior CDC graft patency to be 95.5%. In the seven pairs of grafts in which one graft was occluded and the contralateral graft of another type was patent, the CDC graft was patent and the ePTFE graft was occluded in every instance. Explant histology and scanning electron microscopy showed greater collagenization, less residual platelet-fibrin and red blood cell deposits, and more frequent mid-graft endothelialization in the CDC grafts than in the ePTFE grafts.
An important need in hemodialysis is a self-sealing prosthesis for vascular access with at least equivalent patency and biostability to expanded polytetrafluoroethylene (ePTFE) alternatives. The authors have developed a Corethane/polyester composite (CPC) graft with an inner blood interfacing layer of spun Corethane fibers (10-15 microns diameter; pore size 30-60 microns) impregnated with a gelatin-heparin complex and an outer soft tissue interfacing warp-knitted polyester sheath. Twenty-six CPC grafts (6 mm internal diameter; 25-30 cm length) and eight Gore-Tex ePTFE grafts (same dimensions) were implanted as femoral artery-to-vein shunts in dogs on low dose (162 mg/day) aspirin, and subjected to weekly dialysis needle punctures for up to 52 weeks. Patency was 73% (19/26 with 15 at 52 weeks) for the CPC grafts and 63% (5/8 at 52 weeks) for the ePTFE controls, with more favorable healing (e.g., less extensive mural thrombi) of the CPC grafts. The hemostasis time per needle pair after removal (3.1 min mean for CPC versus 21.2 min mean for ePTFE) and the blood loss in achieving hemostasis (5.7 g mean for CPC versus 47.9 g for ePTFE) documented the significant (p < 0.0001) performance advantages of the CPC prosthesis.